• 제목/요약/키워드: 3D-Scanning

검색결과 1,477건 처리시간 0.033초

Injection-Locking Coupled Oscillators를 이용한 빔 주사 용 능동 위상배열안테나의 설계 및 제작 (A design and fabrication of active phased array antenna for beam scanning using injection-locking coupled oscillators)

  • 이두한;김교헌;홍의석
    • 한국통신학회논문지
    • /
    • 제22권8호
    • /
    • pp.1622-1631
    • /
    • 1997
  • A 3-stages Active Microstrip Phased Array Antenn(AMPAA) is implemented using Injection-Locking Coupled Oscillators(ILCO). The AMPAA is a beam scanning active antenna with capability of electrical scanning by frequency varation of ILCO. The synchronization of resonance frequencies in array elements is occured by ILCO, and the ILCO amplifies the injection signal and functions as a phase shifter. The microstrip ptch is operated as a radiation element. The unilateral amplifier is a mutual coupling element of AMPAA, eliminates the reverse locking signal and controls the locking bandwidth of ILCO. The possibility of Monolithic Microwave Integrated Circuits(MMIC) of T/R module is proposed by simplified and integrated fabrication process of AMPAA. The 0.75.$lambda_{0}$ is fixed for a mutual coupling space to wide the scanning angle and minimize the multi-mode. The AMPAA has beam scanning angle of 31.4.deg., HPBW(Half Power Beam Widths) of 26.deg., directive gain of 13.64dB and side lobe of -16.5dB were measured, respectively.

  • PDF

Spectrum-Based Color Reproduction Algorithm for Makeup Simulation of 3D Facial Avatar

  • Jang, In-Su;Kim, Jae Woo;You, Ju-Yeon;Kim, Jin Seo
    • ETRI Journal
    • /
    • 제35권6호
    • /
    • pp.969-979
    • /
    • 2013
  • Various simulation applications for hair, clothing, and makeup of a 3D avatar can provide more useful information to users before they select a hairstyle, clothes, or cosmetics. To enhance their reality, the shapes, textures, and colors of the avatars should be similar to those found in the real world. For a more realistic 3D avatar color reproduction, this paper proposes a spectrum-based color reproduction algorithm and color management process with respect to the implementation of the algorithm. First, a makeup color reproduction model is estimated by analyzing the measured spectral reflectance of the skin samples before and after applying the makeup. To implement the model for a makeup simulation system, the color management process controls all color information of the 3D facial avatar during the 3D scanning, modeling, and rendering stages. During 3D scanning with a multi-camera system, spectrum-based camera calibration and characterization are performed to estimate the spectrum data. During the virtual makeup process, the spectrum data of the 3D facial avatar is modified based on the makeup color reproduction model. Finally, during 3D rendering, the estimated spectrum is converted into RGB data through gamut mapping and display characterization.

3차원 스캔 기술과 니트 소재의 신축성을 적용한 밀착형 스포츠웨어 상의 설계 (Technical Design of Tight Upper Sportswear based on 3D Scanning Technology and Stretch Property of Knitted Fabric)

  • 김태규;박순지;박정환;서추연;최신애
    • 한국의류산업학회지
    • /
    • 제14권2호
    • /
    • pp.277-285
    • /
    • 2012
  • This research studied how to develop tight upper sportswear from 3D scan data considering fabric stretch property. Subjects were five Korean men of average figure in their 20's. Scanning was done for ten postures via vitus smart/pro(Techmath LTD). Analyzing from 3D scan data, more than 70% of the upper body surface showed surface change rate under 20%. It was shoulder and under arm side part that showed most noticeable body surface change when moving. A parametric model with convex surface was generated and flattened onto the plane, resulting 2D pattern. The error rate occurring in the process of 3D to 2D conversion was 0.2% for outline and 0.13% for area, respectively. Thirteen kinds of stretchable fabrics in the market were collected for this study. Stretch property was in the range of 16.0~58.2% for wale direction; 23.1~78.4% for course. Based on wear trial test, four fabrics were chosen for making the 1st experimental garment and finally one fabric was chosen for the 2nd one, which was developed applying 4 kinds of crosswise reduction rate on 2D pattern: 0, 5, 10, and 15%. Through wear trial test and garment pressure measurement, experimental garment applied with 10% pattern reduction rate was evaluated as most comfortable and considerable.

A comparison of the precision of three-dimensional images acquired by 2 digital intraoral scanners: effects of tooth irregularity and scanning direction

  • Anh, Ji-won;Park, Ji-Man;Chun, Youn-Sic;Kim, Miae;Kim, Minji
    • 대한치과교정학회지
    • /
    • 제46권1호
    • /
    • pp.3-12
    • /
    • 2016
  • Objective: The purpose of this study was to compare the precision of three-dimensional (3D) images acquired using iTero$^{(R)}$(Align Technology Inc., San Jose, CA, USA) and Trios$^{(R)}$(3Shape Dental Systems, Copenhagen, Denmark) digital intraoral scanners, and to evaluate the effects of the severity of tooth irregularities and scanning sequence on precision. Methods: Dental arch models were fabricated with differing degrees of tooth irregularity and divided into 2 groups based on scanning sequence. To assess their precision, images were superimposed and an optimized superimposition algorithm was employed to measure any 3D deviation. The t-test, paired t-test, and one-way ANOVA were performed (p < 0.05) for statistical analysis. Results: The iTero$^{(R)}$ and Trios$^{(R)}$ systems showed no statistically significant difference in precision among models with differing degrees of tooth irregularity. However, there were statistically significant differences in the precision of the 2 scanners when the starting points of scanning were different. The iTero$^{(R)}$ scanner (mean deviation, $29.84{\pm}12.08{\mu}m$) proved to be less precise than the Trios$^{(R)}$ scanner ($22.17{\pm}4.47{\mu}m$). Conclusions: The precision of 3D images differed according to the degree of tooth irregularity, scanning sequence, and scanner type. However, from a clinical standpoint, both scanners were highly accurate regardless of the degree of tooth irregularity.

Comparison of 2 root surface area measurement methods: 3-dimensional laser scanning and cone-beam computed tomography

  • Tasanapanont, Jintana;Apisariyakul, Janya;Wattanachai, Tanapan;Sriwilas, Patiyut;Midtbo, Marit;Jotikasthira, Dhirawat
    • Imaging Science in Dentistry
    • /
    • 제47권2호
    • /
    • pp.117-122
    • /
    • 2017
  • Purpose: The aim of this study was to compare the use of 3-dimensional (3D) laser scanning and cone-beam computed tomography (CBCT) as methods of root surface measurement. Materials and Methods: Thirty teeth (15 maxillary first premolars and 15 mandibular first premolars) from 8 patients who required extractions for orthodontic treatment were selected. Before extraction, pre-treatment CBCT images of all the patients were recorded. First, a CBCT image was imported into simulation software (Mimics version 15.01; Materialise, Leuven, Belgium) and the root surface area of each tooth was calculated using 3-Matic (version 7.01, Materialise, Leuven, Belgium). After extraction, all the teeth were scanned and the root surface area of each extracted tooth was calculated. The root surface areas calculated using these 2 measurement methods were analyzed using the paired t-test (P<.05). Correlations between the 2 methods were determined by calculating the Pearson correlation coefficient. The intraclass correlation coefficient(ICC) was used to assess intraobserver reliability. Results: The root surface area measurements ($230.11{\pm}41.97mm^2$) obtained using CBCT were slightly greater than those ($229.31{\pm}42.46mm^2$) obtained using 3D laser scanning, but not significantly (P=.425). A high Pearson correlation coefficient was found between the CBCT and the 3D laser scanner measurements. The intraobserver ICC was 1.000 for 3D laser scanning and 0.990 for CBCT. Conclusion: This study presents a novel CBCT approach for measuring the root surface area; this technique can be used for estimating the root surface area of non-extracted teeth.

한대의 LSV 를 이용한 3 차원 진동측정방법 (Three-dimensional vibration measurement algorithm using one laser scanning vibrometer)

  • 김동규;송하준;박기환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.935-939
    • /
    • 2012
  • 3D vibration measurement is achieved using one laser scanning vibrometer(LSV) and Laser scanner(LS) by moving the LSV to three arbitrarily locations from the principle that vibration analysis based on the frequency domain is independent of the vibration signal based on time domain. The proposed system has the same effect as using three sets of LSVs. It has an advantage of reducing equipment costs. Analytical approach of obtaining in-plane and out-of-plane vibration of surface is introduced using geometrical relations between three LSV coordinates and vibration measured at three different locations.

  • PDF

DEM generation of rock slope using laser scanning and digital stereo photogrammetry

  • Jeong Changyub;Park Hyong-Dong
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.526-528
    • /
    • 2003
  • There are some reports which are about measuring the discontinuity from 3D model of rock surface. To generate 3D model is mainly based on remote sensing technique like laser scanning and digital stereo photogrammetry. It is obtained the DEM of the rock slope using above techniques in this study, and examined a suitability and improvement of the photogrammetry for the rock slope by overlap the DEM. It seems that accuracy of DEM generated by photogrammetry technique is influenced by the geometry of rock and type of joint.

  • PDF

Optical Scanning Holographic Approach to Three-Dimensional Television

  • Poon, Ting-Chung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.281-284
    • /
    • 2002
  • We first review a real-time holographic recording technique called optical scanning holography (OSH) and discuss holographic reconstruction using spatial light modulators (SLMs). We then present how the overall system can be used for three-dimensional (3-D) holographic television (TV) system and address some of the issues encountered. Finally, we suggest some techniques to alleviate the issues encountered in such a 3-D holographic TV.

  • PDF

3D 프린터를 이용한 여성용 인대 제작 연구 (A study of making a dress form for women using a 3D printer)

  • 오설영
    • 복식문화연구
    • /
    • 제24권6호
    • /
    • pp.725-742
    • /
    • 2016
  • In the Korean fashion industry, 3D printing systems are considered as new technology and a new opportunity. With 3D printers, consumers can be manufacturers and individuals can develop businesses with little upfront capital. In this study, a dress form for the typical Korean women's body shape was developed using 3D technology (3D scanning, 3D modeling, and 3D printing). Ten women with apparel sizes 85-91-160 were selected from 3D body-scan data collected by SizeKorea of 201 women aged 25 to 34 (2010). First, 15 horizontal cross-sections were collected from the 3D scan data of the 10 subjects. Then, inside lines of those cross-sections were drawn at 15-degree intervals, and the lengths were measured. The average of the inside lines was connected to the internal spline curve, and the curves were used as the average cross-sections. The average torso body and the dress form of Korean women were developed into a 3D solid model using a 3D CAD program (Solidworks 2012). An output mockup was printed by the FDM type's 3D printing system (Bonbot 1200, Bonbot 3-H4) using PLA material. The dimensions comparing the 3D solid modeling to the 3D printed mockup of the dress form were measured, and minor differences were between 0.00cm and 0.40cm. In the future, 3D printing systems are expected to be in use for various personalized dress forms.

인체모델과 3차원 일러스트레이션을 이용한 의복패턴개발 (Direct Clothing Pattern Development from the 3D Illustration on the Personal Human Body Model)

  • 박혜준;홍경희
    • 한국의류학회지
    • /
    • 제32권2호
    • /
    • pp.340-347
    • /
    • 2008
  • A prototype of 3D clothing design system with a direct pattern development function was suggested, reflecting intuitive design functions and design modifications while considering the fit of clothing patterns with the 3D human body in the virtual 3D space. The research method was as follows. Clothing models were created using a 3D design tool, 3ds max on the surface of 3D human body model made by scanning an actual human body. 3D illustrations were completed by revising the fit and sizing of the human body and clothing models. 2D T-shirt pattern was produced 3D illustrations using from a 3D scanning data modeling solution RapidForm 2004, a 2D conversion program for 3D data called 2C-AN, and Yuka CAD. As a result, the following conclusions were made. The fit of the clothing and human body can be adjusted by reflecting individual body figure characteristics and 3D illustrations over the actual 3D body model. Furthermore, intuitive design support functions were intensified overcoming the weak point of existing 3D clothing design system by developing the direct clothing design in the virtual 3D space. 3D illustration design modifications can be directly reflected on clothing patterns from 3D illustrations by 3D clothing design system developed in this study.