• Title/Summary/Keyword: 3D-CT

Search Result 1,110, Processing Time 0.027 seconds

Pressure Analysis of Plantar Musculoskeletal Fascia while Walking using Finite Element Analyses (상세유한요소 모델링을 통한 보행중인 인체족부의 족저압 해석)

  • Jeon, Seong-Mo;Kim, Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.8
    • /
    • pp.913-920
    • /
    • 2012
  • An efficient 3D finite element walking model that considers the detailed shapes of muscles, ligaments, bones, skin, and soles was developed based on a real computed tomography (CT) scan image of a foot, and nonlinear contact analyses were performed to investigate pressure changes. The highest pressure occurs at the rear bottom of the foot when standing and walking. The pressure on the outsole with a curved foot bottom surface is lessened and distributed over a wider area than in the case of a flat outsole. The result shows that a shoe sole shape optimized for diabetes patients can relieve the foot pressure concentration and prevent further worsening of symptoms.

Familial Case of Visceral Larval Migrans of Toxocara Canis after Ingestion of Raw Chicken Liver (닭 간 생식 후 가족에서 집단으로 발생한 개회충에 의한 내장 유충 이행증 1예)

  • Park, Min-Su;Ahn, Young-Joon;Moon, Kyung-Rye
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.13 no.1
    • /
    • pp.70-74
    • /
    • 2010
  • We report a familial case of visceral larva migrans of Toxocara canis after eating raw chicken liver. A 9-year-old female ate raw chicken liver with her father and older brother and was admitted to the hospital with periumbilical pain, a mild fever, and headache. The total peripheral eosinophil count was 9,884/$mm^3$ and the total lgE concentration was 2,317 IU/dL. Chest and abdominal computed tomography (CT) scans demonstrated multiple, poorly-defined, small, nodular lesions scattered in the liver and lung parenchyma. Toxocara ELISA and Western blot tests were positive in the patient, and her father and brother. A liver biopsy revealed extensive eosinophilic infiltrations in the portal and lobular areas. She took albendazole for 5 days and was discharged in good condition. These results suggest that clinicians should consider foodborne toxocariasis in patients with multiple, small nodules in the liver and lung parenchyma with eosinophilia and a history of raw meat ingestion.

The Comparison of Effective between Acupuncture and Bee Venom Acupuncture on the Treatment of Acute Lumbar Herniation of Intervertebral Disc (급성기 요추간판탈출증에 있어 봉약침 치료의 효과에 대한 비교 연구)

  • Cha, Jung-Ho;Chang, So-Young;Lee, Tae-Ho;Owi, Jong-Song;Lee, Eun-Yong
    • Journal of Pharmacopuncture
    • /
    • v.9 no.2
    • /
    • pp.67-71
    • /
    • 2006
  • Objective : Herniation of Intervertebral Disc(HIVD) is the most common disease causing low back pain. Acupuncture and Bee Venom Acupuncture has been us ε d for treatment of HIVD. This study is to investigate the effective of Bee Venom Acupuncture for HIVD. Methods : We researched 18 patients who were diagnosed by CT and MRI as having HIVD, and treated them Acupuncture only or Acupuncture and Bee Venom Acupuncture. We compared the VAS and ROM angle of two groups. Results & Conclusions : 1. In admission date, no significant improvement between Acupuncture group and Bee Venom Acupuncture group 2. In variation of flexion and extension, Bee Venom Acupuncture group shows statistically significant improvement 3. In VAS, Bee Venom Acupuncture group shows statistically significant improvement for 1 week and discharge day

Development of µ-PIM standard mold with exchangable insert core in order to manufacture micro pattern (마이크로 패턴 성형을 위한 인서트 코어 적용 µ-PIM 표준금형 개발에 관한 연구)

  • Park, Chi Yoel;Seo, Chan-Yoel;Kim, Yongdae
    • Design & Manufacturing
    • /
    • v.11 no.3
    • /
    • pp.29-34
    • /
    • 2017
  • Increased demand for parts with micro-pattern structure made of metals, ceramics, and composites in various fields such as medical ultrasonic sensors, CT collimators, and ultra-small actuator parts. Micro powder injection molding (PIM) is a technology for manufacturing micro size, high volume, complex, precision, net-shape components from either metal or ceramic powder. In the present study, a standard mold with a variable insert core capable of producing various micro patterns was investigated. An injection molding test was performed on a standard mold using a line type micro-pattern core having an aspect ratio of 2, a slenderness ratio of 70, a pattern size of $200{\mu}m$, and a pattern spacing of $150{\mu}m$. During the filling process, the deformation of the mold with large aspect ratio and slenderness ratio was analyzed by the experiment and the numerical simulation according to the position of the gate. We proposed a mold structure that minimizes mold deformation by gate modification and enables uniform pattern filling behavior.

Significant Proteinuria Caused by Posterior Nutcracker Phenomenon (호두까기 증후군으로 인해 발생한 다량의 단백뇨)

  • Lee, Jun-Ho;Kim, Geun-Jung
    • Childhood Kidney Diseases
    • /
    • v.14 no.1
    • /
    • pp.84-88
    • /
    • 2010
  • Posterior nutcracker phenomenon (PNP) was found to be the cause of significant proteinuria in a 10-year-old female. PNP was documented by Doppler ultrasonography and abdominal 3D CT as a cause of her proteinuria. Despite treatment with ACE inhibitor for several months, her persistent and progressive proteinuria lead us to perform a left renal biopsy, which revealed no significant finding except for focal effacement of foot processes. We speculate that nutcracker phenomenon can induce not only orthostatic proteinuria but also significant proteinuria by focal effacement of foot processes.

Femoral Fracture load and damage localization pattern prediction based on a quasi-brittle law

  • Nakhli, Zahira;Ben Hatira, Fafa;Pithioux, Martine;Chabrand, Patrick;Saanouni, Khemais
    • Structural Engineering and Mechanics
    • /
    • v.72 no.2
    • /
    • pp.191-201
    • /
    • 2019
  • Finite element analysis is one of the most used tools for studying femoral neck fracture. Nerveless, consensus concerning either the choice of material characteristics, damage law and /or geometric models (linear on nonlinear) remains unreached. In this work, we propose a numerical quasi-brittle damage model to describe the behavior of the proximal femur associated with two methods to evaluate the Young modulus. Eight proximal femur finite elements models were constructed from CT scan data (4 donors: 3 women; 1 man). The numerical computations showed a good agreement between the numerical curves (load - displacement) and the experimental ones. A very encouraging result is obtained when a comparison is made between the computed fracture loads and the experimental ones ($R^2=0.825$, Relative error =6.49%). All specific numerical computation provided very fair qualitative matches with the fracture patterns for the sideway fall simulation. Finally, the comparative study based on 32 simulations adopting linear and nonlinear meshing led to the conclusion that the quantitatively results are improved when a nonlinear mesh is used.

The Use of Artificial Intelligence in Healthcare in Medical Image Processing

  • Elkhatim Abuelysar Elmobarak
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.1
    • /
    • pp.9-16
    • /
    • 2024
  • AI or Artificial Intelligence has been a significant tool used in the organisational backgrounds for an effective improvement in the management methods. The processing of the information and the analysis of the data for the further achievement of heightened efficiency can be performed by AI through its data analytics measures. In the medical field, AI has been integrated for an improvement within the management of the medical services and to note a rise in the levels of customer satisfaction. With the benefits of reasoning and problem solving, AI has been able to initiate a range of benefits for both the consumers and the medical personnel. The main benefits which have been noted in the integration of AI would be integrated into the study. The issues which are noted with the integrated AI usage for the medical sector would also be identified in the study. Medical Image Processing has been seen to integrate 3D image datasets with the medical industry, in terms of Computed Tomography (CT) or Magnetic Resonance Imaging (MRI). The usage of such medical devices have occurred in the diagnosis of the patients, the development of guidance towards medical intervention and an overall increase in the medical efficiency. The study would focus on such different tools, adhered with AI for increased medical improvement.

The Analysis of Blood Glucose Level Difference According to the Exact Use of Blood Glucose Measurement Test Strips in $^{18}F$-FDG Wholebody PET ($^{18}F$-FDG를 이용한 전신 PET 검사에서 혈당 측정 검사지의 정확한 사용에 따른 혈당 수치의 차이 분석)

  • Park, Soon-Ki;Lee, Nam-Ki;NamGung, Chang-Kyung;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.100-103
    • /
    • 2010
  • Purpose: $^{18}F$-FDG wholebody PET is to evaluate the tumor using glucose metabolism. The blood glucose level is important factor that affects on a result of examination. High glucose levels may interfere with tumor targeting due to competitive inhibition of FDG uptake by D-glucose. The blood glucose level measurement test strips used in the blood glucose measurement are classified into the capillary blood measurement test strips and general purpose measurement test strips that can measure the venous blood and capillary blood altogether depends on cases. The purpose of the study was to compare the blood glucose measurements between simultaneously obtained capillary and venous blood samples using the capillary blood measurement test strips, general purpose measurement test strips. Materials and Methods: A total of 46 subjects (32 males, 14 females) with a mean age of $57.3{\pm}12.3$ years were enrolled. The blood glucose estimation was performed with a Optium Xceed Glucometer (Abbott). Simultaneous capillary and venous blood samples were obtained from each subject. The blood glucose levels were measured using the capillary blood measurement test strips and general purpose measurement test strips. The capillary and venous measurements were compared using a pared t-test. Results: The mean capillary and venous glucose values using the general purpose measurement test strips were $95.2{\pm}12.4$ mg/dL and $104.1{\pm}14.4$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (9.0 mg/dL; 95% confidence interval (CI) -11.2 to -6.7). The mean capillary and venous glucose values using the capillary blood measurement test strips were $91.5{\pm}13.6$ mg/dL and $108.6{\pm}16.2$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (16.6 mg/dL; 95% CI -20.2 to -13.0). Conclusion: When measuring the blood glucose level before $^{18}F$-FDG PET examination, since the incorrect blood glucose level can be measured, it should note to measure the blood glucose level of the venous blood by the capillary blood measurement test strips. Therefore the measurement variation can be reduced to fulfill the standardized measurement procedure with the suitable measurement test strips, the preparation of the PET examination will be able to be clearly confirmed. In addition, the standardized procedure of the following measurement on the area which is same at all times the blood area in the blood glucose measurement among a capillary or a vein will be needed.

  • PDF

Treatment of Quadriceps Contracture with Femoral Shortening Ostectomy, Rectus Femoris Muscle Transposition and Dynamic Stifle Flexion Apparatus in a Dog

  • Roh, Yoon-Ho;Choi, Min-Ho;Lee, Je-Hun;Mok Jeong, Seong;Lee, HaeBeom
    • Journal of Veterinary Clinics
    • /
    • v.37 no.3
    • /
    • pp.163-167
    • /
    • 2020
  • A 13-month-old, 3.3 kg castrated male Shih-tzu presented with right hindlimb lameness. The physical examination revealed atrophy of the right thigh muscles, hyperextension of the stifle joint and external torsion of the tibia. On the radiographic examination, patella alta and genu recurvatum were observed. A biapical deformity of the tibia and external torsion of the distal tibia were detected by computed tomography (CT). A three-dimensional (3D) printed bone model was designed and constructed for the preoperative plan prior to surgery. Rectus femoris muscle transposition, femoral shortening ostectomy and open wedge osteotomy of the distal tibia were performed using hybrid external skele/t0al fixation (hybrid-ESF). A dynamic stifle flexion apparatus was used to prevent recurrence of a quadriceps contracture (QC). Intense physiotherapy was administered postoperatively. The dog began to use the affected limb one week after surgery. Functional improvement in the affected limb was observed, and full weight-bearing was possible at 3 months after surgery. Union of the osteotomy lines was observed at 3 months, and the stifle joint was fully movable at 7 months after surgery. Regarding the treatments for QC, these methods may be excellent candidates, as they do not lead to severe damage to the limb or amputation.

The Micro-Current Stimulation Inhibits Adipogenesis by Activating Wnt/β-Catenin Signaling (Wnt/β-catenin 신호 활성화를 통한 미세전류 자극의 지방생성 억제 효과)

  • Hwang, Donghyun;Lee, Hana;Lee, Minjoo;Cho, Seungkwan;Kim, Han Sung
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.235-246
    • /
    • 2020
  • This study aimed to evaluate the inhibitory effect of micro-current stimulation(MCS) on adipogenesis regarding with Wnt/β-catenin pathway using the ob/ob mouse and 3T3-L1 cell line. 6-week old ob/ob male mice were equally assigned to four groups: obese group(ob), obese with MCS groups(50 μA, 200 μA, and 400 μA). 6-week old C57BL/6J male mice were assigned to the control group(CON). We analyzed abdominal adipose tissue volume by using in vivo micro-CT and measured the body weight, feed intake, liver weight and triglycerides in serum. All the MCS groups showed that significantly reduced body weight and triglycerides in serum. In the case of liver weight and abdominal adipose tissue volume, the inhibitory effect of adipogenesis was shown in the 200 μA and 400 μA groups. To elucidate the anti-obesity effect of MCS, β-catenin, C/EBPα and FAS protein expressions were analyzed by western blotting. β-catenin expression was upregulated, C/EBPα and FAS expression were down-regulated in the relatively high-intensity groups(200 μA and 400 μA). Thus, the 200 μA and 400 μA for the intensity of MCS were chosen for cell experiments. In the 3T3-L1 cell line, Wnt/β-catenin pathway including Wnt10b, Wnt3a, β-catenin and Cyclin D1 was activated in all MCS groups. Accordingly, the expression level of C/EBPα was decreased during the differentiation and lipid droplet was significantly reduced in Oil red O staining results. These results suggest that the Wnt/β-catenin signaling might be activated by MCS with current intensities between 200-400 μA and it may lead to anti-obesity effects.