• Title/Summary/Keyword: 3D ultrasound

Search Result 159, Processing Time 0.03 seconds

Smart Glasses Cannula Guide System Development for Interventional Cardiology Procedures (중재적 심장 질환 시술을 위한 스마트 글래스 삽입관 가이드 시스템 개발)

  • Jang, Ik Gyu;Heo, Yeong Jun;Jeon, Geum Sang;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.173-178
    • /
    • 2020
  • Remote control intervention surgery robotic system improves treatment effect on cardiovascular patients and reduces X-ray exposure. However, at the time of the first procedure, CT (computerized tomography) and other ultrasound diagnostic equipment should be used because the operator must insert the cannula directly into the patient's leg. Improvements to this have been un-met-needs of hospitals. In this paper, we developed a system that can insert the cannula intuitively and quickly by displaying blood vessels at a glance through the system using smart wearable glasses. The core development method is as follows. In order to project augmented reality onto the surgical image, CT scan angiography image is extracted and processed. In the process, three CT-Markers are used to create a coordinate system of blood vessel images. Additionally, a reference marker is photographed on a single camera to obtain a camera coordinate system. Since the CT marker and the reference marker are in the same position, 3D registration is performed. In the text, a detailed explanation will be given.

Effect of Low Intensity Sound Wave on UC-MSC(Umbilical Cord Mesenchymal Stem Cell Growth (저강도 음파 조사가 중간엽 줄기세포 증식에 미치는 영향)

  • Kim, Sung-Min;Kang, Seung-Ho;Jeong, Jae-Hoon;Park, Jung-Keug;Kim, Soo-Chan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.4
    • /
    • pp.521-525
    • /
    • 2011
  • It is known that the low-intensity sound stimulation really affect to grow the cell. The cellular growth mechanism, however, does not been clearly identified even the effect on the low-intensity sound stimulation. The purpose of this study is to investigate the effect of low-intensity sound stimulation on the alveolar UC-MSC proliferation. Before the low-intensity sound stimulation is applied, the UC-MSC are cultured for 24 hours to facilitate their attachments. The cells are divided into two groups. And each was exposed to a medium with or without the low-intensity ultrasound stimulation at 71dB intensity level. The UC-MSC are again divided into three treatment groups of group 1, 2, and 3 and exposed to a frequency at 50Hz, 100Hz, and 1000Hz, respectively. In the results, it is investigated that the growth rates of UC-MSC for the stimulated groups were higher than those of control groups. In 1000Hz frequency, the number of UC-MSC cell is significantly higher than control groups (p>0.05). We would put the hypothesis that the cell growth could be enhanced by an appropriate low-intensity sound stimulation.

A Study on Control of Drone Swarms Using Depth Camera (Depth 카메라를 사용한 군집 드론의 제어에 대한 연구)

  • Lee, Seong-Ho;Kim, Dong-Han;Han, Kyong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1080-1088
    • /
    • 2018
  • General methods of controlling a drone are divided into manual control and automatic control, which means a drone moves along the route. In case of manual control, a man should be able to figure out the location and status of a drone and have a controller to control it remotely. When people control a drone, they collect information about the location and position of a drone with the eyes and have its internal information such as the battery voltage and atmospheric pressure delivered through telemetry. They make a decision about the movement of a drone based on the gathered information and control it with a radio device. The automatic control method of a drone finding its route itself is not much different from manual control by man. The information about the position of a drone is collected with the gyro and accelerator sensor, and the internal information is delivered to the CPU digitally. The location information of a drone is collected with GPS, atmospheric pressure sensors, camera sensors, and ultrasound sensors. This paper presents an investigation into drone control by a remote computer. Instead of using the automatic control function of a drone, this approach involves a computer observing a drone, determining its movement based on the observation results, and controlling it with a radio device. The computer with a Depth camera collects information, makes a decision, and controls a drone in a similar way to human beings, which makes it applicable to various fields. Its usability is enhanced further since it can control common commercial drones instead of specially manufactured drones for swarm flight. It can also be used to prevent drones clashing each other, control access to a drone, and control drones with no permit.

Review Study on the Measurement Tools of Scoliosis: Mainly on Non-radiological Methods (척추측만증 평가 척도에 관한 문헌 고찰: 비방사선 방법을 중심으로)

  • Kim, Dong-Joo;Choi, Seong-Kyeong;Jo, Hyo-Rim;Ha, Yu-bin;Choi, Sung-Hwan;Park, Seo-Hyun;Lee, Seung Deok;Keum, Dong-Ho;Sung, Won-Suk;Kim, Eun-Jung
    • The Journal of Korean Medicine
    • /
    • v.42 no.1
    • /
    • pp.75-98
    • /
    • 2021
  • Objectives: The purpose of this study is to investigate the characteristics, validity, and reliability of non-radiological assessment tools of scoliosis that have been studied so far. Methods: Electronic databases including Pubmed, Cochrane Library, CNKI, Science On, RISS, OASIS were searched by keywords including 'scoliosis assessment', 'scoliosis screening', 'physical examination', 'functional measurement', 'photography', and 'smartphone'. Results: 32 articles using radiation-free assessments were identified from 1,011 records. The mostly used non-radiological methods were Surface topography, Scoliometer, Ultrasound, Digital Infrared Thermal Imaging, and Photography. The other methods were Gait analysis, 3D depth sensor imaging, and Low intensity electromagnetic scan. Conclusions: It was found that non-radiological assessment tools might reduce the number of radiographs taken in scoliosis patients. To increase the reliability and validity, further research on the measurement tools of scoliosis will be needed.

A Study on a Mask R-CNN-Based Diagnostic System Measuring DDH Angles on Ultrasound Scans (다중 트레이닝 기법을 이용한 MASK R-CNN의 초음파 DDH 각도 측정 진단 시스템 연구)

  • Hwang, Seok-Min;Lee, Si-Wook;Lee, Jong-Ha
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.4
    • /
    • pp.183-194
    • /
    • 2020
  • Recently, the number of hip dysplasia (DDH) that occurs during infant and child growth has been increasing. DDH should be detected and treated as early as possible because it hinders infant growth and causes many other side effects In this study, two modelling techniques were used for multiple training techniques. Based on the results after the first transformation, the training was designed to be possible even with a small amount of data. The vertical flip, rotation, width and height shift functions were used to improve the efficiency of the model. Adam optimization was applied for parameter learning with the learning parameter initially set at 2.0 x 10e-4. Training was stopped when the validation loss was at the minimum. respectively A novel image overlay system using 3D laser scanner and a non-rigid registration method is implemented and its accuracy is evaluated. By using the proposed system, we successfully related the preoperative images with an open organ in the operating room

Clinical Utility of Chest Sonography in Chronic Obstructive Pulmonary Disease Patients Focusing on Diaphragmatic Measurements

  • Hend M. Esmaeel;Kamal A. Atta;Safiya Khalaf;Doaa Gadallah
    • Tuberculosis and Respiratory Diseases
    • /
    • v.87 no.1
    • /
    • pp.80-90
    • /
    • 2024
  • Background: There are many methods of evaluating diaphragmatic function, including trans-diaphragmatic pressure measurements, which are considered the key rule of diagnosis. We studied the clinical usefulness of chest ultrasonography in evaluating stable chronic obstructive pulmonary disease (COPD) patients and those in exacerbation, focusing on diaphragmatic measurements and their correlation with spirometry and other clinical parameters. Methods: In a prospective case-control study, we enrolled 100 COPD patients divided into 40 stable COPD patients and 60 patients with exacerbation. The analysis included 20 age-matched controls. In addition to the clinical assessment of the study population, radiological evaluation included chest radiographs and chest computed tomography. Transthoracic ultrasonography (TUS) was performed for all included subjects. Results: Multiple A lines (more than 3) were more frequent in COPD exacerbation than in stable patients, as was the case for B-lines. TUS significantly showed high specificity, negative predictive value, positive predictive value, and accuracy in detecting pleural effusion, consolidation, pneumothorax, and lung mass. Diaphragmatic measurements were significantly lower among stable COPD subjects than healthy controls. Diaphragmatic thickness and excursion displayed a significant negative correlation with body mass index and the dyspnea scale, and a positive correlation with spirometry measures. Patients in Global Initiative for Chronic Obstructive Lung Disease (GOLD) group D showed lower diaphragmatic measurements (thickness and excursion). Conclusion: The TUS of COPD patients both in stable and exacerbated conditions and the assessment of diaphragm excursion and thickness by TUS in COPD patients and their correlations to disease-related factors proved informative and paved the way for the better management of COPD patients.

Investigation of symmetric dimethylarginine as a serologic marker for kidney function in striped skunks (Mephitis mephitis)

  • Eun Jung;Soong-Hee Youn;Ki-Yong Shin;Hyeon-Joo Shin;Joon-Young Yang;Yeseul Yang;Jae-Ha Jung;Yongbaek Kim
    • Journal of Veterinary Science
    • /
    • v.25 no.4
    • /
    • pp.52.1-52.10
    • /
    • 2024
  • Importance: Kidney disease is prevalent among veterinary species, including zoo animals; however, investigations into this condition in striped skunks (Mephitis mephitis) are scarce. Diagnostic tools for kidney diseases in this species also remain limited. Objective: This study aimed to assess the utility of symmetric dimethylarginine as a biomarker for kidney disease in captive striped skunks in Korea. Methods: This retrospective study analysed 11 striped skunks housed at the Everland Zoo between 2017 and 2021. Blood samples were collected during health checks. Kidney function was assessed through blood analysis and diagnostic ultrasound, with necropsies conducted on deceased animals. Symmetric dimethylarginine levels were measured in 27 plasma samples collected from 11 skunks. Results: Over the study period, seven skunks were diagnosed with kidney disease. Analysis of 27 blood samples revealed a concurrent increase in SDMA levels with concentrations of blood urea nitrogen and blood creatinine. In 3 of the 7 skunks with kidney disease, symmetric dimethylarginine exceeded 14 ㎍/dL prior to the elevation of blood urea nitrogen and blood creatinine above the upper reference limit. Conclusions and Relevance: To our knowledge, this is the first study investigating symmetric dimethylarginine in captive striped skunks in Korea. Our findings suggest that symmetric dimethylarginine may serve as an early and consistent biomarker for renal dysfunction in striped skunks. Further studies with larger clinical sample size from striped skunks are needed to validate the clinical utility of blood symmetric dimethylarginine concentration.

Puerarin pretreatment attenuates cardiomyocyte apoptosis induced by coronary microembolization in rats by activating the PI3K/Akt/GSK-3β signaling pathway

  • Chen, Zhi-Qing;Zhou, You;Huang, Jun-Wen;Chen, Feng;Zheng, Jing;Li, Hao-Liang;Li, Tao;Li, Lang
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.25 no.2
    • /
    • pp.147-157
    • /
    • 2021
  • Coronary microembolization (CME) is associated with cardiomyocyte apoptosis and cardiac dysfunction. Puerarin confers protection against multiple cardiovascular diseases, but its effects and specific mechanisms on CME are not fully known. Hence, our study investigated whether puerarin pretreatment could alleviate cardiomyocyte apoptosis and improve cardiac function following CME. The molecular mechanism associated was also explored. A total of 48 Sprague-Dawley rats were randomly divided into CME, CME + Puerarin (CME + Pue), sham, and sham + Puerarin (sham + Pue) groups (with 12 rats per group). A CME model was established in CME and CME + Pue groups by injecting 42 ㎛ microspheres into the left ventricle of rats. Rats in the CME + Pue and sham + Pue groups were intraperitoneally injected with puerarin at 120 mg/kg daily for 7 days before operation. Cardiac function, myocardial histopathology, and cardiomyocyte apoptosis index were determined via cardiac ultrasound, hematoxylin-eosin (H&E) and hematoxylin-basic fuchsin-picric acid (HBFP) stainings, and TdT-mediated dUTP nick-end labeling (TUNEL) staining, respectively. Western blotting was used to measure protein expression related to the phosphoinositide 3-kinase (PI3K)/protein kinase B (Akt)/glycogen synthase kinase-3β (GSK-3β) pathway. We found that, puerarin significantly ameliorated cardiac dysfunction after CME, attenuated myocardial infarct size, and reduced myocardial apoptotic index. Besides, puerarin inhibited cardiomyocyte apoptosis, as revealed by decreased Bax and cleaved caspase-3, and up-regulated Bcl-2 and PI3K/Akt/GSK-3β pathway related proteins. Collectively, puerarin can inhibit cardiomyocyte apoptosis and thus attenuate myocardial injury caused by CME. Mechanistically, these effects may be achieved through activation of the PI3K/Akt/GSK-3β pathway.

Relationship between Carotid Intima Media Thickness and Appendicular Skeletal Muscle Index according to Gender (성별에 따른 경동맥 내중막두께와 사지근육량지수와의 관련성)

  • Yang, Sung-Hee;Lee, Hee-Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.309-317
    • /
    • 2022
  • It is reported that social distancing caused by the corona pandemic has resulted in a decrease in physical activity, and a decrease in muscle mass due to this increases the risk of vascular disease. Therefore, in this study, the risk of carotid intima media thickness was evaluated by measuring the thickness of CIMT, and the differences in variables according to gender were analyzed. From January 2022 to May 2022, a total of 220 people (121 males, 99 females) who performed blood tests, carotid ultrasound, and body composition analysis among those who visited the health check-up center of Busan H Hospital were included in this study. Significant differences in risk factors according to gender were analyzed using the chi-square test. The cut-off values of variables that can predict the risk of carotid intima media thickness were calculated, and the accuracy was evaluated by calculating the area under the curve, sensitivity, and specificity. As a result of the difference analysis, the higher the total cholesterol in men and the appendicular skeletal muscle index in women, the higher the risk of carotid intima media thickness. The cut-off value for predicting the risk of carotid intima media thickness was calculated to be greater than 199 mg/dL of total cholesterol in the male group and less than 5.9 kg/m2 of the appendicular skeletal muscle index in the female group. As a result of this study, the higher the total cholesterol in men and the lower the appendicular skeletal muscle index in women, the higher the risk of increased CIMT. Therefore, in women, the appendicular skeletal muscle index is expected to serve as an indicator to predict and prevent vascular changes at an early stage.

Monte Carlo Simulations of Selection Responses for Improving High Meat Qualities Using Real Time Ultrasound in Korean Cattle (초음파측정 활용 고급육형 한우개량을 위한 선발반응 Monte Carlo 모의실험)

  • Lee, D. H.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.3
    • /
    • pp.343-354
    • /
    • 2003
  • Simulation studies were carried out to investigate the responses of selection for three carcass traits (longissimus muscle area: EMA, fat thickness: BF, and marbling score: MS) based on either adjusted phenotypes (APH) or estimated breeding values (EBV) in multivariate animal model with different breeding schemes. Selection responses were estimated and compared on six different models with respect to breeding schemes using either carcass measurements or real time ultrasonic (RTU) scans generated by Monte Carlo computer simulation supporting closed breeding population. From the base population with 100 sires and 2000 dams, 20 sires and 1000 dams by each generation were selected by either APH or EBV for 10 generations. Relative economic weights were equal of three traits as EMA(1): BF(-1) : MS(1) for standardized either APH or EBV. For first two models which were similarly designed with current progeny-test program in Korean cattle, three carcass traits with records either only on male progenies (Model 1) or on male and female progenies (Model 2) were used for selecting breeding stocks. Subsequently, generation intervals on males were assumed as 6${\sim}$10 years in these two models. The other two models were designed with tools of selection by RTU rather than carcass measurements with genetic correlations of 0.81${\sim}$0.97 between RTU and corresponding carcass traits in addition to whether with records (Model 4) or without records (Model 3) on female. In these cases, generation intervals on males were assumed as 2${\sim}$4 years. The remaining last two models were designed as similar with Models 3 and 4 except genetic correlations of 0.63${\sim}$0.68 between RTU and corresponding carcass traits with records (Model 6) and without records (Model 5) on females. The results from 10 replicates on each model and selecting methods suggested that responses indirect selection for carcass traits in Model 4 were 1.66${\sim}$2.44 times efficient rather than those in Model 1. Otherwise, in Model 6 with assuming moderate genetic correlations, those efficiencies were 1.18${\sim}$2.08 times with comparing to responses in Model 1. However, selection response for marbling score was the smallest among three carcass traits because of small variation of measurements. From these results, this study suggested that indirect selection using RTU technology for improving high meat qualities in Korean cattle would be valuable with modifying measuring rules of marbling score forward to large variation or modifying relative economic weight for selection.