• Title/Summary/Keyword: 3D solid model

Search Result 295, Processing Time 0.035 seconds

Effect of thread design on the marginal bone stresses around dental implant (임플란트 나사산 디자인이 변연골 응력에 미치는 영향)

  • Lee, Sang-Hyun;Jo, Kwang-Heon;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.316-323
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the effect of different thread designs on the marginal bone stresses around dental implant. Materials and methods: Standard ITI implant(ITI Dental Implant System; Straumann AG, Waldenburg, Switzerland), 4.1 mm in diameter and 10 mm in length, was selected as control. Test implants of four different thread patterns were created based on control implant, i.e. maintaining all geometrical design of control implant except thread pattern. Four thread designs used in test implants include (1) small V-shape screw (model A), (2) large V-shape screw (model B), (3) buttress screw (model C), and (4) trapezoid screw (model D). Surface area for unit length of implant was 14.4 $mm^2$ (control), 21.7 (small V-shape screw), 20.6 (large V-shape screw), 17.0 (buttress screw) and 28.7 $mm^2$ (trapezoid screw). Finite element models of implant/bone complex were created using an axisymmetric scheme with the use of NISA II/DISPLAY III (Engineering Mechanics Research Corporation, Troy, MI, USA). A load of 100 N applied to the central node on the crown top either in parallel direction or at 30 degree to the implant axis (in order to apply non-axial load to the implant NKTP type 34 element was employed). Quantification and comparison of the peak stress in the marginal bone of each implant model was made using a series of regression analyses based on the stress data calculated at the 5 reference points which were set at 0.2, 0.4, 0.6, 0.8 and 1.0 mm from implant wall on the marginal bone surface. Results: Results showed that although severe stress concentration on the marginal bone cannot be avoided a substantial reduction in the peak stress is achievable using different thread design. The peak marginal bone stresses under vertical loading condition were 7.84, 6.45, 5.96, 6.85, 5.39 MPa for control and model A, B, C and D, respectively. And 29.18, 26.45, 25.12, 27.37, 23.58 MPa when subject to inclined loading. Conclusion: It was concluded that the thread design is an important influential factor to the marginal bone stresses.

Numerical modelling of Fault Reactivation Experiment at Mont Terri Underground Research Laboratory in Switzerland: DECOVALEX-2019 TASK B (Step 2) (스위스 Mont Terri 지하연구시설 단층 내 유체 주입시험 모델링: 국제공동연구 DECOVALEX-2019 Task B(Step 2))

  • Park, Jung-Wook;Guglielmi, Yves;Graupner, Bastian;Rutqvist, Jonny;Park, Eui-Seob
    • Tunnel and Underground Space
    • /
    • v.29 no.3
    • /
    • pp.197-213
    • /
    • 2019
  • We simulated the fault reactivation experiment conducted at 'Main Fault' intersecting the low permeability clay formations of Mont Terri Underground Research Laboratory in Switzerland using TOUGH-FLAC simulator. The fluid flow along a fault was modelled with solid elements and governed by Darcy's law with the cubic law in TOUGH2, whereas the mechanical behavior of a single fault was represented by creating interface elements between two separating rock blocks in FLAC3D. We formulate the hydro-mechanical coupling relation of hydraulic aperture to consider the elastic fracture opening and failure-induced dilation for reproducing the abrupt changes in injection flow rate and monitoring pressure at fracture opening pressure. A parametric study was conducted to examine the effects of in-situ stress condition and fault deformation and strength parameters and to find the optimal parameter set to reproduce the field observations. In the best matching simulation, the fracture opening pressure and variations of injection flow rate and monitoring pressure showed good agreement with field experiment results, which suggests the capability of the numerical model to reasonably capture the fracture opening and propagation process. The model overestimated the fault displacement in shear direction and the range of reactivated zone, which was attributed to the progressive shear failures along the fault at high injection pressure. In the field experiment results, however, fracture tensile opening seems the dominant mechanism affecting the hydraulic aperture increase.

Validation and Calibration of 2D Numerical Model for Analysis of Turbidity Current Regimes in Soyang Reservoir (소양호 탁수거동 해석을 위한 2차원 수치 모형의 보정 및 검증)

  • Ryu, In-Gu;Chung, Se-Woong;Yoon, Sung-Wan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.253-257
    • /
    • 2010
  • 최근 들어 이상 강우 현상으로 인한 기록적인 집중 강우와 더불어 토지 이용 변화로 인해 탁수의 발생 빈도가 증가하고 있다. 강우 유출로 유입한 탁수는 저수지 내 장기간 체류하면서 하류 하천의 수질 및 수생태계 뿐만 아니라 저수지 내부의 영양단계에도 많은 영향을 준다. 특히, 성층화된 저수지의 경우 높은 영양염류 농도를 포함한 탁수는 밀도류 거동 특성을 보이면서 수평 및 수직 혼합 과정을 거치면서 국부적인 부영양화 현상과 조류의 수화 현상의 원인이 되고 있다. 따라서 대형 저수지의 수질관리에 있어 하천 유입 탁수의 밀도류 해석, 저수지의 수온 성층 구조 변화, 부유입자의 동력학적 해석이 중요한 요소로 부각되어 왔다. 본 연구에서는 소양호를 연구 대상 지역으로 선정하여 2005년과 2007년 수문 사상을 바탕으로 2차원 횡방향 수치 모형을 구축하였다. 수치모형을 통해 수온 성층 구조의 재현성을 확인하였으며, 다양한 탁수 거동 모형을 구축하여 적용성을 평가하였다. 유입수의 SS(Suspended Solid)를 단일 입경으로 가정한 TM-1 모형, SS의 입경분포에 따라 3개의 그룹(SSi)으로 구분한 TM-2 모형, 3개 그룹을 포함하면서 저수지내 탁수 장기화로 인한 탁수 저감 효과를 1차 반응상수로 매개 변수화(유기물 함량($a_0$) ${\times}$ 분해속도(${\lambda}_a$))하여 수정된 지배방정식을 적용한 TM-3 모형을 사용하였다. 각각의 탁수 거동 모형은 2005년과 2007년 수문 조건에서 수온 성층 구조를 잘 재현하였다. TM-1 모형과 TM-2 모형을 비교해보면, 탁수 중심축의 최고 탁도에 대한 예측 성능은 TM-2 모형이 우수한 결과를 나타냈었다. 하지만, 장기 탁수 모의 시 저수지 수중 잔류 SS가 지속적으로 높게 나타나 중층 탁도를 과대평가하는 경향을 보였다. TM-3 모형이 TM-2 모형에 비해 수심별 탁도 분포에 대한 중심축 탁도가 저평가되는 경향을 보였지만 저수지 내 잔류 탁도에 대한 영향 부분에서는 개선된 결과를 나타내었다. 본 연구 결과는 저수지 탁수 밀도류 해석 및 운영 시스템에 활용 될 수 있으며, 선택 취수 설비 등의 수리 구조물의 영향 평가에 활용할 수 있다.

  • PDF

Finite Element Stress Analysis of Implant Prosthesis of Internal Connection System According to Position and Direction of Load (임플랜트-지대주의 내측연결 시스템에서 하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소 응력분석)

  • Jang, Jong-Seok;Jeong, Yong-Tae;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.1
    • /
    • pp.1-14
    • /
    • 2005
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis of internal connection system(ITI system) according to position and direction of load, under vertical and inclined loading using finite element analysis (FEA). The finite element model of a synOcta implant and a solid abutment with $8^{\circ}$ internal conical joint used by the ITI implant was constructed. The gold crown for mandibular first molar was made on solid abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric cusp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant under both vertical and oblique loading but stresses in the cancellous bone were low under both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. So, the relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 4. In this internal conical joint, vertical and oblique loads were resisted mainly by the implant-abutment joint at the screw level and by the implant collar. Conclusively, It seems to be more important that how long the distance is from center of rotation of the implant itself to the resultant line of force from occlusal contact (leverage). In a morse taper implant, vertical and oblique loads are resisted mainly by the implant-abutment joint at the screw level and by the implant collar. This type of implant-abutment connection can also distribute forces deeper within the implant and shield the retention screw from excessive loading. Lateral forces are transmitted directly to the walls of the implant and the implant abutment mating bevels, providing greater resistance to interface opening.

Interleukin-7 Enhances the in Vivo Anti-tumor Activity of Tumor-reactive CD8+ T cells with Induction of IFN-gamma in a Murine Breast Cancer Model

  • Yuan, Chun-Hui;Yang, Xue-Qin;Zhu, Cheng-Liang;Liu, Shao-Ping;Wang, Bi-Cheng;Wang, Fu-Bing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.1
    • /
    • pp.265-271
    • /
    • 2014
  • Interleukin-7 (IL-7) is a potent anti-apoptotic cytokine that enhances immune effector cell functions and is essential for lymphocyte survival. While it known to induce differentiation and proliferation in some haematological malignancies, including certain types of leukaemias and lymphomas, little is known about its role in solid tumours, including breast cancer. In the current study, we investigated whether IL-7 could enhance the in vivo antitumor activity of tumor-reactive $CD8^+$ T cells with induction of IFN-${\gamma}$ in a murine breast cancer model. Human IL-7 cDNA was constructed into the eukaryotic expression plasmid pcDNA3.1, and then the recombinational pcDNA3.1-IL-7 was intratumorally injected in the TM40D BALB/C mouse graft model. Serum and intracellular IFN-${\gamma}$ levels were measured by ELISA and flow cytometry, respectively. $CD8^+$ T cell-mediated cytotoxicity was analyzed using the MTT method. Our results showed that IL-7 administration significantly inhibited tumor growth from day 15 after direct intratumoral injection of pcDNA3.1-IL-7. The anti-tumor effect correlated with a marked increase in the level of IFN-${\gamma}$ and breast cancer cells-specific CTL cytotoxicity. In vitro cytotoxicity assays showed that IL-7-treatment could augment cytolytic activity of $CD8^+$ T cells from tumor bearing mice, while anti-IFN-${\gamma}$ blocked the function of $CD8^+$ T cells, suggesting that IFN-${\gamma}$ mediated the cytolytic activity of $CD8^+$ T cells. Furthermore, in vivo neutralization of $CD8^+$ T lymphocytes by CD8 antibodies reversed the antitumor benefit of IL-7. Thus, we demonstrated that IL-7 exerts anti-tumor activity mainly through activating $CD8^+$ T cells and stimulating them to secrete IFN-${\gamma}$ in a murine breast tumor model. Based on these results, our study points to a potential novel way to treat breast cancer and may have important implications for clinical immunotherapy.

Hydro-Mechanical Modelling of Fault Slip Induced by Water Injection: DECOVALEX-2019 TASK B (Step 1) (유체 주입에 의한 단층의 수리역학적 거동 해석: 국제공동연구 DECOVALEX-2019 Task B 연구 현황(Step 1))

  • Park, Jung-Wook;Park, Eui-Seob;Kim, Taehyun;Lee, Changsoo;Lee, Jaewon
    • Tunnel and Underground Space
    • /
    • v.28 no.5
    • /
    • pp.400-425
    • /
    • 2018
  • This study presents the research results and current status of the DECOVALEX-2019 project Task B. Task B named 'Fault slip modelling' is aiming at developing a numerical method to simulate the coupled hydro-mechanical behavior of fault, including slip or reactivation, induced by water injection. The first research step of Task B is a benchmark simulation which is designed for the modelling teams to familiarize themselves with the problem and to set up their own codes to reproduce the hydro-mechanical coupling between the fault hydraulic transmissivity and the mechanically-induced displacement. We reproduced the coupled hydro-mechanical process of fault slip using TOUGH-FLAC simulator. The fluid flow along a fault was modelled with solid elements and governed by Darcy's law with the cubic law in TOUGH2, whereas the mechanical behavior of a single fault was represented by creating interface elements between two separating rock blocks in FLAC3D. A methodology to formulate the hydro-mechanical coupling relations of two different hydraulic aperture models and link the solid element of TOUGH2 and the interface element of FLAC3D was suggested. In addition, we developed a coupling module to update the changes in geometric features (mesh) and hydrological properties of fault caused by water injection at every calculation step for TOUGH-FLAC simulator. Then, the transient responses of the fault, including elastic deformation, reactivation, progressive evolutions of pathway, pressure distribution and water injection rate, to stepwise pressurization were examined during the simulations. The results of the simulations suggest that the developed model can provide a reasonable prediction of the hydro-mechanical behavior related to fault reactivation. The numerical model will be enhanced by continuing collaboration and interaction with other research teams of DECOLVAEX-2019 Task B and validated using the field data from fault activation experiments in a further study.

A Study on the Thermal Environment Evaluation of 'Hanok' considering Solid Model of Building Elements (한옥의 건축요소 솔리드 모델링을 통한 열환경 평가에 관한 연구)

  • Park, Tong-So;Sheen, Dong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.955-961
    • /
    • 2013
  • This study aimed for the scientific approach of Korean traditional house, so called Hanok, by analyses of structural elements and thermal environmental performance. Hanok is a very unique vernacular architectural style of the Middle East Asia that fits with climate conditions of the Korean Peninsular, designed to withstand high temperature and humidity in summer and cold and dry in winter seasons. In order to evaluate thermal environment of Hanok, its sectional structure such as floor, wall, roof structure and Ondol which is Korean traditional floor heating system, was built in 3D, as well as heat transfer mechanism of its composing elements was analyzed through 3 dimensional steady state analysis. The results of the thermal environmental performance of Hanok will be used as a basic datum of design guidelines for accomplishing ecologic housing fitted with local climate.

Fibula Free Flap for Mandibular Reconstruction using Simulation Surgery in Bisphosphonate related Osteonecrosis of the Jaw

  • Kim, Hong-Joon;Hwang, Jong-Hyun;Ahn, Kang-Min
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Purpose Bisphophonate-related osteonecrosis of the jaw (BRONJ) is an emerging problem. Extensive osteonecrosis of the jaw needs free flap reconstruction. Free fibular flap is the most useful flap for maxilla-mandibular hard and soft tissue reconstruction. The advantages of fibular free flap are simultaneous soft and hard tissue reconstruction and placing implant in reconstructed mandible and maxilla. In this study, four consecutive BRONJ patients who underwent fibula free flap reconstruction using simulation surgery were reviewed. Materials and Methods Four BRONJ patients who underwent free fibula reconstruction between May 2006 and September 2014 were included in this study. Male to female ratio was 1:3 and average age was 67.3 years old (62-70). All patients need mandibular bone reconstruction. Three patients suffered from osteoporosis and one male patient had multiple myeloma. Postoperative flap survival, functional reconstruction, esthetic results, food taking were evaluated. Results Three osseous flaps and one osteocutaneous flap were used. All the fibular flaps were survived and patients were recovered without complications. Oro-cutaneous fistula was resolved after operation. All patients were satisfied with the esthetic results. Patients reported improved solid food intake after operation with partial denture. One fully edentulous patient had semi-fluid diet after operation. Conclusion Treatment of the BRONJ is difficult due to lack of standard protocol. Fibular free flap using simulation surgery is the workhorse flap for mandibular hard and soft tissue reconstruction, especially in stage III BRONJ patient. In this study, functional and esthetic results were successful in all patients. Normal diet was possible with partial dentures.

Modeling of Elastodynamic Problems in Finite Solid Media (유한 고체내 탄성동역학 문제의 모델링)

  • Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.2
    • /
    • pp.138-149
    • /
    • 2000
  • Various modeling techniques for ultrasonic wave propagation and scattering problems in finite solid media are presented. Elastodynamic boundary value problems in inhomogeneous multi-layered plate-like structures are set up for modal analysis of guided wave propagation and numerically solved to obtain dispersion curves which show propagation characteristics of guided waves. As a powerful modeling tool to overcome such numerical difficulties in wave scattering problems as the geometrical complexity and mode conversion, the Boundary Element Method(BEM) is introduced and is combined with the normal mode expansion technique to develop the hybrid BEM, an efficient technique for modeling multi mode conversion of guided wave scattering problems. Time dependent wave forms are obtained through the inverse Fourier transformation of the numerical solutions in the frequency domain. 3D BEM program development is underway to model more practical ultrasonic wave signals. Some encouraging numerical results have recently been obtained in comparison with the analytical solutions for wave propagation in a bar subjected to time harmonic longitudinal excitation. It is expected that the presented modeling techniques for elastic wave propagation and scattering can be applied to establish quantitative nondestructive evaluation techniques in various ways.

  • PDF

Train-Structure Dynamic Interaction Analysis of The Bridge Transition Considering Track Irregularity (궤도틀림을 고려한 교대접속부의 열차상호동적거동해석)

  • Choi, Chan-Yong;Kim, Hun-Ki;Chung, Keun-Young;Yang, Sang-Beom
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.9
    • /
    • pp.29-38
    • /
    • 2015
  • In this study, track dynamic interaction characteristics caused by the vehicle running through transitional section such as bridge abutments were studied using the finite element analysis program. The geometric condition of track was generated by trigonometric function and allowable maximum track irregularity is determined by KORAIL track maintenance criteria. The sub-infrastructure under rail fastener system was modelled by 3D solid elements. To reduce computational cost only half track line is numerically considered and the roller boundary condition was applied to each side of model. In this study, the vehicle-track dynamic interaction analysis was carried out for standard Korean transition section of concrete track and the dynamic behaviors were investigated. The dynamic characteristics considered are wheel load variation, vertical acceleration at body, and maximum Mises stress at each part of transitional section.