Browse > Article
http://dx.doi.org/10.5762/KAIS.2013.14.2.955

A Study on the Thermal Environment Evaluation of 'Hanok' considering Solid Model of Building Elements  

Park, Tong-So (Dept. of Architecture, Hanseo University)
Sheen, Dong-Jin (Dept. of Aero-Dynamic Engineering, Hanseo University)
Publication Information
Journal of the Korea Academia-Industrial cooperation Society / v.14, no.2, 2013 , pp. 955-961 More about this Journal
Abstract
This study aimed for the scientific approach of Korean traditional house, so called Hanok, by analyses of structural elements and thermal environmental performance. Hanok is a very unique vernacular architectural style of the Middle East Asia that fits with climate conditions of the Korean Peninsular, designed to withstand high temperature and humidity in summer and cold and dry in winter seasons. In order to evaluate thermal environment of Hanok, its sectional structure such as floor, wall, roof structure and Ondol which is Korean traditional floor heating system, was built in 3D, as well as heat transfer mechanism of its composing elements was analyzed through 3 dimensional steady state analysis. The results of the thermal environmental performance of Hanok will be used as a basic datum of design guidelines for accomplishing ecologic housing fitted with local climate.
Keywords
Building Elements; Hanok(Korean Tranditional House); 3-Dimensional Steady State Analysis; Thermal Environment Evaluation;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Chun, Chungyoon, Research Trend of Building Science and Korean Traditional Construction Technology -Research on Environmental Characteristics and Component Performance of Korean Traditional Building, Review of Architecture and Building Science, AIK, March. Vol 53. No 3. pp17-20. Korea, 2008.
2 Jeong, Jae-Weon, Verification of Thermal Performance of Korean Traditional Residence through Field Measurement at Nakseonjae in Changdeokgung, AIK. Vol 52. No 28. pp687-690, Korea, 2008.
3 Yeo, Myoung Seuk, Development of Partial Radiant Heating System Considering Ondol, Review of Architecture and Building Science, AIK, March. Vol 53. No 3. pp59-64. Korea, 2008.
4 Park, Tong So, Passive Control of Architectural environment Base in the Design Method of Korean Traditional Architecture with reference to "Young-am House", Environmentally Friendly Cities, Proceedings of PLEA 98, June. pp257-260. Lisbon, Portugal, 1998.
5 Park, Tong-So, Field Survey on the Thermal Environment of Folk House in Middle Region, Proceedings of the Spring Conference of AIK, April. Vol 15. No 1. pp.259-262. Korea, 1995.
6 Park, Tong-So, The Thermal Environmental of Traditional House, Ullung Island. Proceedings of the Spring Conference of AIK, April. Vol 13. No 1. pp217-220. Korea, 1993.
7 KS L ISO 6946: Building Components and Building elements - Thermal resistance and thermal transmittance- Calculation Method, KSSN pp3-22. Korea, 2008.
8 ISO 7730: Ergonomics of the thermal environment - Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria, 2005.