• 제목/요약/키워드: 3D placement

검색결과 153건 처리시간 0.027초

Comparison of Power Loss and Magnetic Flux Distribution in Octagonal Wound Transformer Core Configurations

  • Cinar, Mehmet Aytac;Alboyaci, Bora;Sengul, Mehlika
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1290-1295
    • /
    • 2014
  • In this paper, various configurations of octagonal wound transformer core topology, which has previously proved advantages on conventional wound cores, are studied. Each configuration has different joint types and different placement of joint zones on the core. Magnetic flux distributions and power losses of each configuration are analyzed and compared. Comparisons are based on both 2D&3D finite element simulations and experimental studies. The results show that, joint types and their placements on the core cause local flux accumulations and dramatically affect power loss of the core.

사용자 인지 실험 기반 쉐이딩 알고리즘 평가 (Shading Algorithm Evaluation based on User Perception)

  • 변혜원;박윤영
    • 한국콘텐츠학회논문지
    • /
    • 제11권6호
    • /
    • pp.106-115
    • /
    • 2011
  • 본 논문에서는 기존에 제시된 쉐이딩 알고리즘들이 음영 표현을 통해 3차원 물체의 형태를 효과적으로 전달하는지 평가하고 검증한다. 8가지 스타일로 쉐이딩된 10개의 3차원 물체 중의 한 개의 이미지를 사람들에게 보여주고 물체 표면의 여러 곳의 위치에서 곡면의 법선 벡터와 일치하도록 측정기(gauge)의 방향을 조정하도록 요청하는 스터디를 수행한다. 이 실험에서 수집한 법선 벡터 추정치가 사람들 간에 서로 일치하는지 비교하고 또한 실제 3차원 곡면 모델의 법선 벡터와 일치하는지도 비교한다. 본 논문의 실험을 통하여 물체의 음영을 표현하는 방법에 따라서 사람들이 물체의 형태를 다르게 해석한다는 사실을 보인다. 또한, 기존의 쉐이딩 알고리즘들 중에서 음영 톤의 단계수가 많고 톤 단계가 전반적으로 균일하게 분포되어 있는 특성을 가지는 알고리즘이 물체의 형태를 보다 효과적으로 표현하는 것으로 나타났다. 본 논문에서 수집한 실험 데이터 및 분석 결과는 물체의 형태를 효과적으로 전달하는 것을 목적으로 하는 새로운 CG 쉐이딩 알고리즘을 설계하는데 활용 가능할 것으로 기대된다.

자동착유시스템 설치농가의 설치 후 만족도에 관한 실태조사 (A Suvey on Satisfaction Measurement of Automatic Milking System in Domestic Dairy Farm)

  • 기광석;김종형;정영훈;김윤호;박성재;김상범;이왕식;이현준;조원모;백광수;김현섭;권응기;김완영;여준모
    • 한국축산시설환경학회지
    • /
    • 제17권1호
    • /
    • pp.39-48
    • /
    • 2011
  • 본 시험은 국내에 도입되기 시작한 AMS에 대하여 설치 동기, 설치 후 우유생산량과우유품질, AMS 설치계기 및 설치 후 만족도, AMS 운영상 애로점 및 건의사항 등을 조사 분석하였다. 설치 계기가 무엇인가에 대한 응답비율은 노동력 부족 44%, 체험목장으로 전환 25%, 소들의 고능력화에 대응 19% 순이었으며 기타 6%였다. AMS 설치농가의 사육경력은 평균 24.9년, 평균 연령은 53.2세로 나타났으며 가족노동력만으로 경영하는 목장이 조사농가의 38%, 고용+자가노동력 형태의 목장이 63%로 나타났다. 목장의 산유능력은 두당 평균 유량은 1일 $30.9{\ell}$, 평균 유지율 3.9%, 세균수는 9.1천개/$m{\ell}$ 수준이었다. 후계자 육성에 대한 질문에 매우 그렇다라고 응답한 비율은 68%였으며, 보통 18%, 아니다와 매우 아니다라고 응답한 비율은 18%로 나타났다. 시스템 운영현황 및 애로사항을 파악하기 위하여 AMS의 프로그램 주운영자에 대한 질문에 본인 44%, 부인 6%, 자녀 또는 후계자사람이 44%, 기타 6%나 되었다. AMS 운영상 가장 어려운 점에 대한 조사결과, 기기 작동 및 복잡한 프로그램 운영이 각각 31%로 가장 많았다. 그 외 기계 에러 및 고장에 대한 애로사항이 25%이였다. 도태원인에 대하여 유방염 28%, 번식장애 20%, 발굽질환 19%, AMS에 부적합한 유두 배열 12%, 분만 후 대사성질병 7%, 노산 등 기타 14%였다. 시스템 설치 후 유지보수 계약 체결유무 및 비용에 대하여 유지보수 계약 56%, 유지 보수 계약 미체결 44%이었다. 유지보수 계약 평균 계약비용은 연간 658만원 정도였다. 시스템 설치 후 항목별 만족도에 대하여 5점 만점에 3.9점이었으며, 노동력 절감 3.7점, 업체의 A/S 3.6점, 산유량 증가 3.2점, 원유의 체세포 수 저감 2.8점이었다. 시스템 설치 시 고려사항 및 건의사항에 대하여 고가의 장비를 효율적으로 사용하기 위하여 젖소의 유방과 유두 배열이 적합하도록 젖소를 선발하는 것, 시스템을 운용할 수 있는 능력, 적합한 환경, 재정적 능력과 부지 확보, 지속적인 관찰 등이 권장되어야 할 것으로 나타났으며, 설치 업체에 대해서는 컨설팅이 체계화될 필요가 가장 높게 나타났으며 이어서 보다 저렴한 설치와 서비스의 체계화를 요구하는 결과를 보였다.

Does cone-beam CT alter treatment plans? Comparison of preoperative implant planning using panoramic versus cone-beam CT images

  • Guerrero, Maria Eugenia;Noriega, Jorge;Castro, Carmen;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • 제44권2호
    • /
    • pp.121-128
    • /
    • 2014
  • Purpose: The present study was performed to compare the planning of implant placement based on panoramic radiography (PAN) and cone-beam computed tomography (CBCT) images, and to study the impact of the image dataset on the treatment planning. Materials and Methods: One hundred five partially edentulous patients (77 males, 28 females, mean age: 46 years, range: 26-67 years) seeking oral implant rehabilitation were referred for presurgical imaging. Imaging consisted of PAN and CBCT imaging. Four observers planned implant treatment based on the two-dimensional (2D) image data-sets and at least one month later on the three-dimensional (3D) image dataset. Apart from presurgical diagnostic and dimensional measurement tasks, the observers needed to indicate the surgical confidence levels and assess the image quality in relation to the presurgical needs. Results: All observers confirmed that both imaging modalities (PAN and CBCT) gave similar values when planning implant diameter. Also, the results showed no differences between both imaging modalities for the length of implants with an anterior location. However, significant differences were found in the length of implants with a posterior location. For implant dimensions, longer lengths of the implants were planned with PAN, as confirmed by two observers. CBCT provided images with improved scores for subjective image quality and surgical confidence levels. Conclusion: Within the limitations of this study, there was a trend toward PAN-based preoperative planning of implant placement leading towards the use of longer implants within the posterior jaw bone.

완전무치악 환자에서 디지털 가이드 수술 방식을 이용한 무피판절개 임플란트 식립증례: 증례보고 및 5년 추적관찰 (Flapless implant placement with digital 3D imaging and planning system in fully edentulous patient: A case report and 5-year follow-up)

  • 신미선;백장현
    • 대한치과보철학회지
    • /
    • 제57권3호
    • /
    • pp.312-320
    • /
    • 2019
  • 디지털 방식을 이용한 치과 임플란트 진료에서 가장 주목받는 분야 중 하나가 디지털 소프트웨어와 컴퓨터 단층촬영을 이용하여 수술용 스텐트를 제작, 임플란트를 식립하는 분야이다. 컴퓨터를 이용한 디지털 임플란트 치료계획 시스템과 이를 이용한 수술용 가이드는 예지성과 심미성, 기능성을 갖춘 임플란트의 식립과 수복을 가능하게 한다. 특히 이러한 가이드 수술은 임플란트 수복물의 형태와 기능을 고려한 임플란트의 식립 시 더욱 유리하다. 최근 여러 제조사에서 보철물 제작을 위해 치과용 스캔부터 제작방법까지 다양한 디지털 방식의 제작과정을 제시하고 있다. 이러한 방법들은 정확하고 예지성 있는 예후를 위해 여러 연구자들에 의해 연구되어지고 있으며, 점차 발전하고 있다. 이번 증례는 완전무치악의 여성 환자에서 임플란트 고정성 보철물을 이용한 수복증례이다. 하악은 all-on-four 방식을 적용하여 4개의 임플란트를 식립하였으며, 상악은 이에 기초하여 6개의 임플란트를 식립하였다. 최종보철물에 기초한 임플란트의 식립을 위해 임플란트 수술용 스텐트를 이용하였으며, 환자는 치료 결과에 만족하였으며, 5년 추적관찰 결과, 임플란트와 보철물 모두 안정적으로 유지되고 있다.

New virtual orthodontic treatment system for indirect bonding using the stereolithographic technique

  • Son, Kyoung-Hoi;Park, Jae-Woo;Lee, Dong-Keun;Kim, Ki-Dal;Baek, Seung-Hak
    • 대한치과교정학회지
    • /
    • 제41권2호
    • /
    • pp.138-146
    • /
    • 2011
  • The purpose of this article is to introduce a new virtual orthodontic treatment (VOT) system, which can be used to construct three-dimensional (3D) virtual models, establish a 3D virtual setup, enable the placement of the virtual brackets at the predetermined position, and fabricate the transfer jig with a customized bracket base for indirect bonding (IDB) using the stereolithographic technique. A 26-year-old woman presented with anterior openbite, crowding in the upper and lower arches, and narrow and tapered upper arch, despite having an acceptable profile and balanced facial proportion. The treatment plan was rapid palatal expansion (RPE) without extraction. After 10 days of RPE, sufficient space was obtained for decrowding. After a 10-week retention period, accurate pretreatment plaster models were obtained using silicone rubber impression. IDB was performed according to the protocol of the VOT system. Crowding of the upper and lower arches was effectively resolved, and anterior openbite was corrected to normal overbite. Superimposition of the 3D virtual setup models (3D-VSM) and post-treatment 3D virtual models showed that the latter deviated only slightly from the former. Thus, the use of the VOT system helped obtain an acceptable outcome in this case of mild crowding treated without extraction. More cases should be treated using this system, and the pre- and post-treatment virtual models should be compared to obtain feedback regarding the procedure; this will support doctors and dental laboratory technicians during the learning curve.

Self-drilling 방식의 마이크로임플란트 식립에 의해 발생하는 피질골 스트레인의 유한요소해석 (Finite element analysis of cortical bone strain induced by self-drilling placement of orthodontic microimplant)

  • 박진서;유원재;경희문;권오원
    • 대한치과교정학회지
    • /
    • 제39권4호
    • /
    • pp.203-212
    • /
    • 2009
  • 골밀도가 높고 두꺼운 피질골에 마이크로임플란트를 self-drilling 방식으로 식립하는 경우 과도한 수준의 골부하 (bone loading)가 발생할 위험이 있으며 이는 인접골의 정상적인 골개형(bone remodeling)에 장애를 초래할 수 있다. 이에, 본 연구에서는 유한요소해석으로 두께 1.0 mm의 피질골에 Absoanchor SH1312-7 마이크로임플란트((주)덴토스, 대구, 대한민국)가 self-drilling 방식으로 식립되는 과정(10회전, 식립깊이 5 mm)을 모사(simulation)하였으며 식립 단계별로 피질골에 발생되는 스트레인을 조사하였다. 식립중 마이크로임플란트 첨부의 절삭연(cutting flute)에 의한 골삭제로 생기는 나사길(threaded groove)의 치수를 얻기 위하여 가토 경골에 마이크로임플란트를 식립/제거한 후 Micro CT (Explore Locus RS, GE Healthcare, Ontario, Canada)를 이용하여 기하형상을 측정하였으며 이를 치밀골의 유한요소모델에 반영하였다. 해석결과, 치밀골에 발생되는 스트레인은 임플란트 식립깊이에 따라 증가하였고, 초기단계에서 나사산에 인접한 골에 국한되던 과부하 부위(스트레인이 4,000${\mu}$-strain을 상회하는 영역)가 식립깊이 증가에 따라 인접골 전체, 즉 나사산 인접부는 물론 골(valley) 부위에 접하는 모든 영역으로 확장되었다. 본 연구를 통해, self-drilling 방식으로 마이크로임플란트를 식립할 때 치밀골에 발생하는 스트레인 크기는 생리적인 골개형을 저해할 수 있는 수준임을 확인할 수 있었다.

간호사의 내부지향적 정책, 사회적지지 및 직무배태성이 이직의도에 미치는 영향 (Effects of Internal Oriented Policy, Social Support, and Job Embeddedness by Turnover Intention of Nurses)

  • 김중경;이선주;김원종
    • 한국산학기술학회논문지
    • /
    • 제21권3호
    • /
    • pp.89-95
    • /
    • 2020
  • 본 연구는 간호사의 내부지향적 정책, 사회적지지 및 직무배태성이 이직의도에 미치는 영향에 대해 알아보기 위한 서술적 조사연구이다. 연구대상자는 연구 참여에 동의한 D광역시에 위치한 2개 대학병원 간호사들이며, 자료 수집은2018년 10월 2일부터 2019년 3월 20일 까지 실시되었다. 자료 분석은 SPSS 22.0 프로그램을 이용하였으며, 빈도와 백분율, 평균과 표준편차, 상관분석, t-test, ANOVA, Pearson's correlation, Multiple regression을 이용하였다. 연구결과 내부지향적 정책은 3.04점, 사회적지지는 상사 3.08점, 동료 3.81점, 가족 3.67점이었고, 직무배태성은 2.98점, 이직의도는 3.55점이었으며, 내부지향적 정책, 사회적지지 및 직무배태성이 높을수록 이직의도는 감소하는 것으로 나타났다. 일반적 특성에서 이직의도에 미치는 요인을 파악한 결과 임상경력과 근무부서가 유의미한 결과를 보였다. 임상경력은 높을수록 이직의도가 높았고, 근무부서는 외과병동, 내과병동, ICU, OR순으로 이직의도가 높았다. 이상의 결과를 바탕으로 간호사의 이직의도를 낮추기 위한 중재방안으로 병원 내부지향적 정책, 사회적지지 및 간호사의 직무배태성을 높이기 위한 프로그램 개발 및 교육이 적극적 이루어져야 할 것이다.

상악 전치부 단일 임플란트의 생존율에 대한 후향적 연구 (A Retrospective clinical study of survival rate of single implant in maxillary anterior teeth)

  • 임지순;채경준;정의원;김창성;조규성;최성호;채중규;김종관
    • Journal of Periodontal and Implant Science
    • /
    • 제36권3호
    • /
    • pp.639-651
    • /
    • 2006
  • This study was performed to investigate the survival rate of single implant used in maxillary anterior region during follow up periods. 231 patients whose single missing tooth in maxillary region had been replaced with 237 implant at the periodontal dept. of Yonsei University Hospital between February 1993 and December 2004. The following results are compiled from 231 patients who received single implant surgery. 1. The major cause of single tooth loss in maxillary anterior region is trauma, followed by periodontal disease and congenital missing. 2. The total survival rate of single implant placed in maxillary anterior region is 94.5%. 3. The survival rate of single implant placed in type II and type IV was 100% and in type III was 92.7%. As for the bone quantity, the survival rate in type A(100%) was most, followed by type B(97.3%) and type C, D (93.5%). 4. The survival rate of implant placement combined with advanced surgery was 94.4%. The results showed that the placement of single implant is considered as a reliable treatment option for a single missing tooth in maxillary anterior region except in certain extreme conditions especially with poor bone quality and quantity.

근관 내 불규칙 확장부에서 sealer 적용방법에 따른 충전 효과 평가 (AN IN-VITRO EVALUATION OF SEALER PLACEMENT METHODS IN SIMULATED ROOT CANAL EXTENSIONS)

  • 김성용;이미정;문장원;이세준;유미경
    • Restorative Dentistry and Endodontics
    • /
    • 제30권1호
    • /
    • pp.31-37
    • /
    • 2005
  • 본 실험은 resin 시편을 이용하여 미리 제작한 근관 내 불규칙 확장부에서 근관 충전용 sealer의 적용 방법에 따른 충전 효과를 평가해 보았다. Endo-training Bloc을 절단하여 사십 개의 규격화된 resin 블록 시편을 획득하였다. 각각의 시편에 $\#20$, 08taper GT 파일을 사용하여 근관을 형성하였고 근관에 손상이 가지 않도록 시편을 양분한 후 양분된 시편의 한 쪽 근관 벽에 다양한 근관 내 확장부를 표현하는 구를 형성하였다. 양분된 시편을 결찰하고 절단 부위를 밀봉하였으며 AH26 sealer를 사용하여 단일 cone 충전법으로 근관을 충전하였다. 네 가지의 근관 충전용 sealer의 적용방법을 이용하였다: A군, $\#20$ K-file : B군, ultrasonic file : C군, lentulo spiral: D군. EZ-Fill bi-directioanl spiral. 모든 시편은 $37^{\circ}\;100\%$ 상대습도에서 1주일간 보관한 후 각 시편을 근단에서 3mm, 4mm, 5mm 부위에서 수평으로 절단하고 각각의 절단면을 위상차현미경과 디지털 카메라를 이용하여 30배율로 관찰하고 촬영하였다. 관찰된 절단면은 scoring system을 이용하여 점수를 산정하였고 각 군 간의 통계적인 유의성 유무는 Fisher's Exact Test를 이용하여 시행하였다.