• Title/Summary/Keyword: 3D placement

Search Result 153, Processing Time 0.029 seconds

Comparison of Power Loss and Magnetic Flux Distribution in Octagonal Wound Transformer Core Configurations

  • Cinar, Mehmet Aytac;Alboyaci, Bora;Sengul, Mehlika
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1290-1295
    • /
    • 2014
  • In this paper, various configurations of octagonal wound transformer core topology, which has previously proved advantages on conventional wound cores, are studied. Each configuration has different joint types and different placement of joint zones on the core. Magnetic flux distributions and power losses of each configuration are analyzed and compared. Comparisons are based on both 2D&3D finite element simulations and experimental studies. The results show that, joint types and their placements on the core cause local flux accumulations and dramatically affect power loss of the core.

Shading Algorithm Evaluation based on User Perception (사용자 인지 실험 기반 쉐이딩 알고리즘 평가)

  • Byun, Hae-Won;Park, Yun-Young
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.6
    • /
    • pp.106-115
    • /
    • 2011
  • In this paper, we evaluate the effectiveness of previous shading algorithms in depicting shape of 3d objects. We perform a study in which people are shown an image of one of ten 3D objects shaded with one of eight styles and asked to orient a gauge to coincide with the surface normal at many positions on the object's surface. The normal estimates are compared with each other and with ground truth data provided by a registered 3D surface model to analyze accuracy and precision. Our experiments suggest that people interpret certain shape differently depending on shading of 3d object. This paper offers substantial evidence that current computer graphics shading algorithms can effectively depict shape of 3d objects where the algorithms have the properties of lots of tone steps and uniformly distributed tone steps. This type of analysis can guide the future development of new CG shading algorithms in computer graphics for the purpose of shape perception.

A Suvey on Satisfaction Measurement of Automatic Milking System in Domestic Dairy Farm (자동착유시스템 설치농가의 설치 후 만족도에 관한 실태조사)

  • Ki, Kwang-Seok;Kim, Jong-Hyeong;Jeong, Young-Hun;Kim, Yun-Ho;Park, Sung-Jai;Kim, Sang-Bum;Lee, Wang-Shik;Lee, Hyun-June;Cho, Won-Mo;Baek, Kwang-Soo;Kim, Hyeon-Shup;Kwon, Eung-Gi;Kim, Wan-Young;Jeo, Joon-Mo
    • Journal of Animal Environmental Science
    • /
    • v.17 no.1
    • /
    • pp.39-48
    • /
    • 2011
  • The present survey was conducted to provide basic information on automatic milking system (AMS) in relation to purchase motive, milk yield and quality, customer satisfaction, difficulties of operation and customer suggestions, etc. Purchase motives of AMS were insufficient labor (44%), planning of dairy experience farm (25%), better performance of high yield cows (19%) and others (6%), respectively. Average cow performance after using AMS was 30.9l/d for milk yield, 3.9% for milk fat, 9,100/ml for bacterial counts. Sixty-eight percentage of respondents were very positive in response to AMS use for their successors but 18% were negative. The AMS operators were owner (44%), successor (44%), wife (6%) and company worker (6%), respectively. The most difficulty (31%) in using AMS was operating the system and complicated program manual. The rate of response to system error and breakdown was 25%. The reasons for culling cow after using AMS were mastitis (28%), reproduction failure (19%), incorrect teat placement (12%), metabolic disease (7%) and others (14%), respectively. Fifty-six percentages of the respondents made AMS maintenance contract and 44% did not. Average annual cost of the maintenance contract was 6,580,000 won. Average score for AMS satisfaction measurement (1 to 5 range) was 3.2 with decrease of labor cost 3.7, company A/S 3.6, increase of milk yield 3.2 and decrease of somatic cell count 2.8, respectively. Suggestions for the higher efficiency in using AMS were selecting cows with correct udder shape and teat placement, proper environment, capital and land, and attitude for continuous observation. Systematic consulting was highly required for AMS companies followed by low cost for AMS setup and systematization of A/S.

Does cone-beam CT alter treatment plans? Comparison of preoperative implant planning using panoramic versus cone-beam CT images

  • Guerrero, Maria Eugenia;Noriega, Jorge;Castro, Carmen;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.44 no.2
    • /
    • pp.121-128
    • /
    • 2014
  • Purpose: The present study was performed to compare the planning of implant placement based on panoramic radiography (PAN) and cone-beam computed tomography (CBCT) images, and to study the impact of the image dataset on the treatment planning. Materials and Methods: One hundred five partially edentulous patients (77 males, 28 females, mean age: 46 years, range: 26-67 years) seeking oral implant rehabilitation were referred for presurgical imaging. Imaging consisted of PAN and CBCT imaging. Four observers planned implant treatment based on the two-dimensional (2D) image data-sets and at least one month later on the three-dimensional (3D) image dataset. Apart from presurgical diagnostic and dimensional measurement tasks, the observers needed to indicate the surgical confidence levels and assess the image quality in relation to the presurgical needs. Results: All observers confirmed that both imaging modalities (PAN and CBCT) gave similar values when planning implant diameter. Also, the results showed no differences between both imaging modalities for the length of implants with an anterior location. However, significant differences were found in the length of implants with a posterior location. For implant dimensions, longer lengths of the implants were planned with PAN, as confirmed by two observers. CBCT provided images with improved scores for subjective image quality and surgical confidence levels. Conclusion: Within the limitations of this study, there was a trend toward PAN-based preoperative planning of implant placement leading towards the use of longer implants within the posterior jaw bone.

Flapless implant placement with digital 3D imaging and planning system in fully edentulous patient: A case report and 5-year follow-up (완전무치악 환자에서 디지털 가이드 수술 방식을 이용한 무피판절개 임플란트 식립증례: 증례보고 및 5년 추적관찰)

  • Shin, Mi-sun;Paek, Janghyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.312-320
    • /
    • 2019
  • One of the fastest growing segments of implant dentistry is the utilization of computed tomography (CT) scan data and treatment planning software in conjunction with guided surgery for implant reconstruction cases. Computer assisted planning systems and associated surgical templates have established a predictable, esthetic, functional technique for placing and restoring implants. Especially, a philosophy of restoratively driven implant placement has been generally adopted. Recently, a variety of commercial dental fields have released their scanning and fabricating protocols and methods for restorations. This process is still being investigated and developed for the most precise and predictable outcome. This case report describes a female patient who wanted dental implants in fully edentulous areas. Restoratively driven implant placements were performed with surgical guide and the patient was fully satisfied with the clinical results, and at 5-year post restorative follow-up assessment, both implant and prosthesis were proved clinical success.

New virtual orthodontic treatment system for indirect bonding using the stereolithographic technique

  • Son, Kyoung-Hoi;Park, Jae-Woo;Lee, Dong-Keun;Kim, Ki-Dal;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.138-146
    • /
    • 2011
  • The purpose of this article is to introduce a new virtual orthodontic treatment (VOT) system, which can be used to construct three-dimensional (3D) virtual models, establish a 3D virtual setup, enable the placement of the virtual brackets at the predetermined position, and fabricate the transfer jig with a customized bracket base for indirect bonding (IDB) using the stereolithographic technique. A 26-year-old woman presented with anterior openbite, crowding in the upper and lower arches, and narrow and tapered upper arch, despite having an acceptable profile and balanced facial proportion. The treatment plan was rapid palatal expansion (RPE) without extraction. After 10 days of RPE, sufficient space was obtained for decrowding. After a 10-week retention period, accurate pretreatment plaster models were obtained using silicone rubber impression. IDB was performed according to the protocol of the VOT system. Crowding of the upper and lower arches was effectively resolved, and anterior openbite was corrected to normal overbite. Superimposition of the 3D virtual setup models (3D-VSM) and post-treatment 3D virtual models showed that the latter deviated only slightly from the former. Thus, the use of the VOT system helped obtain an acceptable outcome in this case of mild crowding treated without extraction. More cases should be treated using this system, and the pre- and post-treatment virtual models should be compared to obtain feedback regarding the procedure; this will support doctors and dental laboratory technicians during the learning curve.

Finite element analysis of cortical bone strain induced by self-drilling placement of orthodontic microimplant (Self-drilling 방식의 마이크로임플란트 식립에 의해 발생하는 피질골 스트레인의 유한요소해석)

  • Park, Jin-Seo;Yu, Won-Jae;Kyung, Hee-Moon;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.39 no.4
    • /
    • pp.203-212
    • /
    • 2009
  • Objective: The aim of this study was to evaluate the strain induced in the cortical bone surrounding an orthodontic microimplant during insertion in a self-drilling manner. Methods: A 3D finite element method was used to simulate the insertion of a microimplant (AbsoAnchor SH1312-7, Dentos Co., Daegu, Korea) into 1 mm thick cortical bone. The shape and dimension of thread groove in the center of the cortical bone produced by the cutting flute at the apical of the microimplant was obtained from animal test using rabbit tibias. A total of 3,600 analysis steps was used to calculate the 10 turns and 5 mm advancement of the microimplant. A series of remesh in the cortical bone was allowed to accommodate the change in the geometry accompanied by the implant insertion. Results: Bone strains of well higher than 4,000 microstrain, the reported upper limit for normal bone remodeling, were observed in the peri-implant bone along the whole length of the microimplant. Level of strains in the vicinity of either the screw tip or the valley part were similar. Conclusions: Bone strains from a microimplant insertion in a self-drilling manner might have a negative impact on the physiological remodeling of cortical bone.

Effects of Internal Oriented Policy, Social Support, and Job Embeddedness by Turnover Intention of Nurses (간호사의 내부지향적 정책, 사회적지지 및 직무배태성이 이직의도에 미치는 영향)

  • Kim, Jung Kyung;Lee, Sun Ju;Kim, Won Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.89-95
    • /
    • 2020
  • This study is a descriptive research to investigate the effects of nurses' internal orientation, social support and job orientation on turnover intention. The subjects were two university hospital nurses in D metropolitan city who agreed to participate in the study. Data collection was conducted from October 2, 2018 to March 20, 2019. The data were analyzed using SPSS 22.0 program, frequency and percentage, mean and standard deviation, correlation analysis, t-test, ANOVA, Pearson's correlation, and multiple regression. The study results were 3.04 ± .62 points for internal orientation policy, 3.08 ± .55 points for social support, 3.81 ± .59 points for peers, 3.67 ± .60 points for family members, and 2.98 ± 0.43 points for job placement and intention to turnover. The degree of turnover decreased with higher internal orientation, social support and job orientation. An examination of the general characteristics of the factors affecting turnover intention showed significant results with clinical experience and working department. The higher the clinical experience, the higher the turnover intention, and the department of work showed the higher turnover intention in the order of surgical ward, medical ward, ICU, and OR. These results show the need to actively develop and educate programs to improve nurses' intention to turnover, as well as internal hospital-oriented policies, social support, and job placement.

A Retrospective clinical study of survival rate of single implant in maxillary anterior teeth (상악 전치부 단일 임플란트의 생존율에 대한 후향적 연구)

  • Im, Ji-Soon;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Choi, Seong-Ho;Chai, Jung-Kyu;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.3
    • /
    • pp.639-651
    • /
    • 2006
  • This study was performed to investigate the survival rate of single implant used in maxillary anterior region during follow up periods. 231 patients whose single missing tooth in maxillary region had been replaced with 237 implant at the periodontal dept. of Yonsei University Hospital between February 1993 and December 2004. The following results are compiled from 231 patients who received single implant surgery. 1. The major cause of single tooth loss in maxillary anterior region is trauma, followed by periodontal disease and congenital missing. 2. The total survival rate of single implant placed in maxillary anterior region is 94.5%. 3. The survival rate of single implant placed in type II and type IV was 100% and in type III was 92.7%. As for the bone quantity, the survival rate in type A(100%) was most, followed by type B(97.3%) and type C, D (93.5%). 4. The survival rate of implant placement combined with advanced surgery was 94.4%. The results showed that the placement of single implant is considered as a reliable treatment option for a single missing tooth in maxillary anterior region except in certain extreme conditions especially with poor bone quality and quantity.

AN IN-VITRO EVALUATION OF SEALER PLACEMENT METHODS IN SIMULATED ROOT CANAL EXTENSIONS (근관 내 불규칙 확장부에서 sealer 적용방법에 따른 충전 효과 평가)

  • Kim, Sung-Young;Lee, Mi-Jeong;Moon, Jang-Won;Lee, Se-Joon;Yu, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.1
    • /
    • pp.31-37
    • /
    • 2005
  • The aim of this study was to evaluate the effectiveness of sealer placement in simulated root canal extensions. Forty resin blocks were attained from the Endo-training Bloc. In each block. The simulated root canal was made with $\#20$, 80taper GT file. After each block was longitudinally split into two halves, a standardized groove was prepared on one canal wall of two halves to simulate the canal extensions with various irregularities. The two halves of each block were assembled and all simulated root canals were obturated by single cone method with AH26 sealer. Four different methods of sealer placement were used: group A, $\#20$ K-file; group B, ultrasonic file; group C, lentulo spiral; group D, EZ-Fill bi-directional spiral. All obturated blocks were stored in $100\%$ humidity at $37^{\circ}C$ for 1 week, Using a low speed saw, each block was sectioned horizontally. Images of the sections were taken using a stereomicroscope at $\times$ 30 magnification and a digital camera. The amount of the sealer in the groove was evaluated using a scoring system, a higher score indicated better sealing effectiveness. The data was statistically analysed by Fisher's Exact Test. The sealing score was the lowest, specially at the middle area of canal extensions in group A, and that was statistically significant difference from other groups. In conclusion, the ultrasonic file, lentulo spiral and EZ-Fill bi-directional spiral were effective methods of sealer placement in simulated canal extensions. The K file was the least effective method, specially at the middle area of canal extensions.