• Title/Summary/Keyword: 3D micro-channel

Search Result 45, Processing Time 0.024 seconds

An ERD-TOF System for the Depth Profiling of Light Elements (경원소 적층 분석을 위한 탄성되튐-비행시간 측정시스템)

  • Kim, Y. S.;Woo, H. J.;Kim, J. K.;Kim, D. K.;Choi, H. W.;Hong, W.
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.1
    • /
    • pp.25-32
    • /
    • 1996
  • An ERD-TOF system is constructed for the nondestructive depth profiling of light elements in thin films in the range of several thousand angstroms. The particles, recoiled by 10 $MeV^{35}Cl$ projectiles, were detected by a Time-Of-Flight spectrometer composed of a MCP (Micro Channel Plate) and a SSB (Silicon Surface Barrier) detector. A two parameter data acquisition system composed of two PC's was constructed for registering simultaneous time and energy signals. A $Si_3N_4$/poly-Si/$SiO_2$/Si sample was anlayzed and the result is compared with RBS. The detection limit, maximum probable depth and depth resolution for light elements in silicon are about $4\times10^{14}atoms/\textrm{cm}^2$, 5, 000$\AA$ and 100$\AA$, respectively.

  • PDF

Development of liquid target for beam-target neutron source & two-channel prototype ITER vacuum ultraviolet spectrometer

  • Ahn, B.N.;Lee, Y.M.;Dang, J.J.;Hwang, Y.S.;Seon, C.R.;Lee, H.G.;Biel, W.;Barnsley, R.;Kim, D.E.;Kim, J.G.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.421-422
    • /
    • 2011
  • The first part is about development of a liquid target for a neutron source, which is designed to overcome many of the limitations of traditional beam-target neutron generators by utilizing a liquid target neutron source. One of the most critical aspects of the beam-target neutron generator is the target integrity under the beam exposure. A liquid target can be a good solution to overcome damage to the target such as target erosion and depletion of hydrogen isotopes in the active layer, especially for the one operating at high neutron fluxes with no need for water cooling. There is no inherent target lifetime for the liquid target neutron generator when used with continuous refreshment of the target surface exposed to the energetic beam. In this work, liquid target containing hydrogen has been developed and tested in vacuum environment. Potentially, liquid targets could allow a point neutron source whose spatial extension is on the order of 1 to $10{\mu}m$. And the second is about the vacuum ultraviolet (VUV) spectrometer which is designed as a five-channel spectral system for ITER main plasma measurement. To develop and verify the design, a two-channel prototype system was fabricated with No. 3 (14.4 nm~31.8 nm) and No. 4 (29.0 nm~60.0 nm) among the five channels. For test of the prototype system, a hollow cathode lamp is used as a light source. The system is composed of a collimating mirror to collect the light from source to slit, and two holographic diffraction gratings with toroidal geometry to diffract and also to collimate the light from the common slit to detectors. The two gratings are positioned at different optical distances and heights as designed. To study the appropriate detector for ITER VUV system, two different electronic detectors of the back-illuminated charge coupled device and the micro-channel plate electron multiplier were installed and the performance has been investigated and compared in the same experimental conditions. The overall system performance was verified by measuring the spectrums.

  • PDF

Feasibility of On-chip Detection of Endotoxin by LAL Test

  • Lee, Eun-Kyu;Suh, Chang-Woo;Hwang, Sang-Youn;Park, Hyo-Jin;Seong, Gi-Hoon;Ahn, Yoo-Min;Kim, Yang-Sun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.2
    • /
    • pp.132-136
    • /
    • 2004
  • The LAL (Limulus amebocyte lysate) test for the detection and quantification of endotoxin is based on the gelation reaction between endotoxin and LAL from a blood extract of Limulus polyphemus. The test is labor intensive, requiring dedicated personnel, a relatively long reaction time (approximately 1 h), relatively large volumes of samples and reagents and the detection of the end-point is rather subjective. To solve these problems, a miniaturized LOC (lab-on-a-chip) prototype, 62mm (L) ${\times}$ 18 mm (W), was fabricated using PDMS (polydimethylsiloxane) bonded to glass. Using this prototype, in which 2mm (W) ${\times}$ 44.3mm (L) ${\times}$ 100 $\mu\textrm{m}$ (D) microfluidic channel was constructed, turbidometric and chromogenic assay detection methods were compared, and the chromogenic method was found the most suitable for a small volume assay. In this assay, the kinetic-point method was more accurate than the end-point method. The PDMS chip thickness was found to be minimized to around 2 mm to allow sufficient light transmittance, which necessitated the use of a glass slide bonding for chip rigidity. Due to this miniaturization, the test time was reduced from 1 h to less than 10 min, and the sample volume could be reduced from 100 to ca. 4.4 ${\mu}$L. In summation, this study suggested that the LOC using the LAL test principle could be an alternative as a semi-automated and reliable method for the detection of endotoxin.

Studies on the Improvement of the Fishing Efficiency of Purse Seine in the Sea Area of Cheju Island -The Changes of Seine Volume and Tension in the Purseline During Pursing- (제주도 주변해역 선망의 어획성능 향상에 관한 연구 -짐줄 체결 중 선망의 용적과 짐줄의 장력 변화 -)

  • 김석종
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.2
    • /
    • pp.93-101
    • /
    • 1999
  • A simple experimental method was used in an attempt to realize the elevation of the fishing ability of purse seine in the sea area of Cheju Island, the changes of seine volume and tension in the purseline during pursing. Experiments carried out on the six types simplified reduced model seines which were made of knotless nettings. The nettings were woven in different leg length 4.3, 5.0, 5.5, 6.0, 6.6 and 7.7mm of polyester 28 tex two threads two-ply twine, and each of the seines were named I, II, III, IV, V and Ⅵ seine. Dimension of seine models were 450cm for corkline and 85cmfor seine depth, each seines rigged up 160g of float for a floatline and 50g (underwater weight) of lead for a leadline. These model purse seines were made of the scale of 1/200 of its full scale, a 120 ton in the near sea of Cheju Island. Designing and testing for the model purse seines were based on the Tauti's law. Experiments were measured in the observation channel of a flume tank at the static conditions set up shooting and pursing equipments. Motion of purse seine during purse line was recorded by the two sets video camera for VTR which were placed in top and front of the model seine. The reading coordinate of seine volume carried out by the video digitization system, disk data for the purseline tension. An analysis were performed on the changes seine volume and tension in the purseline during pursing. The results obtained were as follows: 1. The seine volume during pursing was largest for Ⅵ seine with smallest d/l followed by V, IV, III, II and I seines, and tension in the purseline was small. 2. Seine volume during pursing can be expressed by the following equation; CVt=l-EXP[{2.79 (d/l)+0.35}t-33.37 (d/l) + 0.57] Where CVt is volume ratio, d is twine diameter, l is leg length and t is pursing time (sec). 3. Tension in the purse line during pursing can be expressed by the following equation; T= 1- EXP {0.57t + 13.36 (d/l)+2.97} Where T is tension (kg) in the purseline during pursing.

  • PDF

Quality Characteristics of Korean Chive (Allium tuberosum Rotter) as affected by Inner Film Packaging Methods in Paper Box (부추의 종이박스 내 속포장에 따른 품질 특성)

  • Jang, Min Sun;Lee, Jung-Soo;Chandra, Dulal;Choi, Jee Won;Lee, Jin-Su;Park, Me Hea;Choi, Hyun Jinn;Hong, Yuun Pyo;Kim, Ji Gang
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.23 no.3
    • /
    • pp.143-150
    • /
    • 2017
  • Effects of packaging methods for maintaining the shelf-life and postharvest quality of Korean chive (Allium tuberosum Rotter) usually called buchu in Korea was studied during fall season. Buchu, which has high moisture content and active metabolism after harvest, is characterized by the greater changes in quality during storage and distribution. It is usually packaged in paper box during distribution in domestic channel in Korea where the marketability ends within few days of harvest. In order to maintain the commercial quality of buchu, we tried to use inner film with or without absorbent paper in commercial paper box packaging. The 'Greenbelt' cultivar of buchu was harvested in october and packaged in corrugated paper box (A), in corrugated paper box with micro-perforated high density polyethylene (HDPE) film as inner material (B), a layer of absorbent paper both at the bottom and top of buchu in corrugated paper box (C) and a combination of HDPE film as inner material along with a layer of absorbent paper both at the bottom and top of buchu in corrugated paper box (D), and stored at $5^{\circ}C$ for up to 21 days. Several quality parameters such as fresh weight loss, respiration rate, color, chlorophyll content and sensory qualities were monitored during storage. When buchu was packaged only in paper box, the appearance and quality deteriorated rapidly through decay development thereby sample became unmarketable within 12 days. On the other hand, buchu packaged with inner HDPE film maintained its quality, good visual appearance and exhibited a longer period of marketable life compared to the samples stored in other treatments. However, the use of absorbent paper did not have any significant effect in maintaining quality of buchu. The uses of inner HDPE film was effective in reducing weight loss that resulted better visual appearance of buchu. Results suggest that the use of inner HDPE film in bulk type corrugated paper box packaging and storing at $5^{\circ}C$ could be the optimum condition for commercial storage of buchu. Further investigation on other quality parameters and packaging methods would be useful in maintaining the quality aspects of buchu at postharvest stages.