• Title/Summary/Keyword: 3D micro metal

Search Result 61, Processing Time 0.028 seconds

Development of µ-PIM standard mold with exchangable insert core in order to manufacture micro pattern (마이크로 패턴 성형을 위한 인서트 코어 적용 µ-PIM 표준금형 개발에 관한 연구)

  • Park, Chi Yoel;Seo, Chan-Yoel;Kim, Yongdae
    • Design & Manufacturing
    • /
    • v.11 no.3
    • /
    • pp.29-34
    • /
    • 2017
  • Increased demand for parts with micro-pattern structure made of metals, ceramics, and composites in various fields such as medical ultrasonic sensors, CT collimators, and ultra-small actuator parts. Micro powder injection molding (PIM) is a technology for manufacturing micro size, high volume, complex, precision, net-shape components from either metal or ceramic powder. In the present study, a standard mold with a variable insert core capable of producing various micro patterns was investigated. An injection molding test was performed on a standard mold using a line type micro-pattern core having an aspect ratio of 2, a slenderness ratio of 70, a pattern size of $200{\mu}m$, and a pattern spacing of $150{\mu}m$. During the filling process, the deformation of the mold with large aspect ratio and slenderness ratio was analyzed by the experiment and the numerical simulation according to the position of the gate. We proposed a mold structure that minimizes mold deformation by gate modification and enables uniform pattern filling behavior.

Carbon Nanotube Growth for Field Emission Display Application

  • Choi, G.S.;Park, J.B.;Hong, S.Y.;Cho, Y.S.;Son, K.H.;Kim, D-J;Song, Y.H.;Lee, J.H.;Cho, K.I.;Kim, D.J.
    • Journal of Information Display
    • /
    • v.2 no.3
    • /
    • pp.54-59
    • /
    • 2001
  • The role of $NH_3$ for vertical alignment of CNTs was investigated. The direct cause of the alignment was a dense distribution of catalytic metal particles, but which was kept catalytically active during the growth process by $NH_3$. This allows a dense nucleation of the CNTs, and consequently, assists vertical alignment through entanglement and mechanical leaning among the tubes. The CNTs grow in a base growth mode. Several evidences were presented including a direct cross-sectional TEM observation. Since Ni is consumed both by silicide reaction and by capture in the growing tube, the growth stops when Ni is completely depleted. This occurs faster for smaller particles, and thus a longer growth results in thin bottom with poor adhesion.

  • PDF

Fabrication and Electrochemical Characterization of All Solid State Thin Film Micro-Battery by in-situ sputtering (In-situ 스퍼터링을 이용한 마이크로 박막 전지의 제작 및 전지 특성 평가)

  • 전은정;신영화;남상철;조원일;손봉희;윤영수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.159-162
    • /
    • 1999
  • All solid state thin film micro-batteries consisting of lithium metal anode, an amorphous LiPON electrolyte and cathode of vanadium oxide have been fabricated and characterized, which were fabricated with cell structure of Li/LiPON/V$_2$O$\sub$5/Pt. The vanadium oxide thin films were formed by d.c. reactive sputtering on Pt current collector. After deposition of vanadium oxide films, in-situ growths of lithium phosphorus oxynitride film were conducted by r.f. sputtering of Li$_3$PO$_4$ target in mixture gas of N$_2$ and O$_2$. The pure metal lithium film was deposited by thermal evaporation on thin film LiPON electrolyte. The cell capacity was about 45${\mu}$Ah/$\textrm{cm}^2$ $\mu\textrm{m}$ after 200 cycle. No appreciable degradation of the cell capacity could be observed after 50 cycles .

  • PDF

Lour Voltage Operated RFMEMS Switch for Advanced Mobile System Applications (차세대 이동통신시스템에 적용을 위한 저전압구동의 RFMEMS 스위치)

  • Seo, Hye-K.;Park, Jae-Y.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2395-2397
    • /
    • 2005
  • A low voltage operated piezoelectric RF MEMS in-line switch has been realized by using silicon bulk micromachining technologies for advanced mobile/wireless applications. The developed RF MEMS in-line switches were comprised of four piezoelectric cantilever actuators with an Au contact metal electrode and a suspended Au signal transmission line above the silicon substrate. The measured operation dc bias voltages were ranged from 2.5 to 4 volts by varying the thickness and the length of the piezoelectric cantilever actuators, which are well agreed with the simulation results. The measured isolation and insertion loss of the switch with series configuration were -43dB and -0.21dB (including parasitic effects of the silicon substrate) at a frequency of 2GHz and an actuation voltage of 3 volts.

  • PDF

Microstrip Patch Antenna with a Metal Cavity Using Conducting Vias (다수의 도체 비어로 형성된 캐비티가 있는 마이크로스트립 패치 안테나)

  • Byun, Woo-Jin;Kim, Bong-Soo;Eun, Ki-Chan;Kim, Kwang-Sun;Song, Myung-Sun
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.371-374
    • /
    • 2005
  • This paper presents the design and fabrication of a cost effective and broad band 8$\times$8 stacked patch array antenna which are backed by a metal cavity operating at 400Hz based on 4 layers LTCC technology. Gain of antenna can be enhanced by using a metal cavity, which can be easily implemented by using LTCC substrates and vias. The broadband performance can be obtained by varying the dimension of patch and the number of layers. Furthermore, to keep the feeding network as smal1 as possible and reduce radiation from feeding network a mirrored patch orientation and embedded micro strip line are adopted, The fabricated antenna is $40\times45\times0.4$ $mm^3$in size. It shows gain 20.4dBi, beam width 10.7deg and impedance bandwidth of l0dE return loss 3.35GHz (40.9$\sim$44.25 GHz), which is about 8% of a center frequency.

  • PDF

Fatigue Behavior of Friction Welded Material of Domestic Dissimilar Steels - In Case of SM 45C to SUS304 Friction Welded Steel - (國산 異種鋼을 摩擦壓接한 경우의 疲勞擧動)

  • 송삼홍;박명과
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.6
    • /
    • pp.953-962
    • /
    • 1987
  • Domestic dissimilar structural steels, SM 45 C and SUS304 were friction welded under optimal welding condition and the micro-artificial holes were drilled at SM 45 C base metal, SM 45 C HAZ, welded zone, SUS 304 HAZ, and SUS 304 base metal for fatigue behavior tests. In this study, the fatigue limit and the behavior of micro-crack propagation, crack propagation rate, and its dependency on stress intensity factor under the low stress level and high stress level of bending stress have been investigated. The results obtained are as follows. (1) The fatgiue strength of the portion of SM45C B.M., SM45C HAZ, welded zune, SUS304 HAZ and SUS304 B.M. on notched friction welded specimens are 20 kgf/mm$^{2}$, 32 kgf/mm$^{2}$, 27kgf/mm$^{2}$, 29kgf/mm$^{2}$, and 29kgf/mm$^{2}$, respectively. (2) The fatigue strength of welded zone of unnotched and notched specimens are 32.5kgf/mm$^{2}$, and 27kgf/mm$^{2}$, respectively. (3) Micro-crack initiation in the welded zone, HAZ, and each base metals occurrs simultaneously in front and rear of micro-hole tips in the view of the rotational directions. (4) Fatigue crack propagates more slowly in the welded zone than in another protions of specimen, regardless of the magnitude of the stress level. (5) Fatigue crack propagation rates were plotted as a function of stress intensity range. The value of m in the equation da/dN=C(.DELTA.K)$^{m}$ was found to range from 2.09-2.55 in this study.

Effect of dilution on micro hardness of Ni-Cr-B-Si alloy hardfaced on austenitic stainless steel plate for sodium-cooled fast reactor applications

  • Balaguru, S.;Murali, Vela;Chellapandi, P.;Gupta, Manoj
    • Nuclear Engineering and Technology
    • /
    • v.52 no.3
    • /
    • pp.589-596
    • /
    • 2020
  • Many components in the assembly section of Sodium-cooled Fast Reactor are made of good corrosionresistant 316 LN Stainless Steel material. To avoid self-welding of the components with the coolant sodium at elevated temperature, hardfacing is inevitable. Ni-based colmonoy-5 is used for hardfacing due to its lower dose rate by Plasma Transferred Arc process due to its low dilution. Since Ni-Cr-B-Si alloy becomes very fluidic while depositing, the major height of the weld overlay rests inside the groove. Hardfacing is also done over the plain surface where grooving is not possible. Therefore, grooved and ungrooved hardfaced specimens were prepared at different travel speeds. Fe content at every 100 ㎛ of the weld overlay was studied by Energy Dispersive Spectroscopy and also the micro hardness was determined at those locations. A correlation between iron dilution from the base metal and the micro hardness was established. Therefore, if the Fe content of the weld overlay is known, the hardness at that location can be obtained using the correlation and vice-versa. A new correlation between micro hardness and dilution coefficient is obtained at different locations. A comparative study between those specimens is carried out to recommend the optimum travel speed for lower dilution.

Development of Micro-chip Removal Equipment Using Bubble (버블을 이용한 미세칩 제거장치의 개발)

  • Choi, Sung-Yun;Kwon, Dae-Gyu;Lee, Sea-Han;Park, Tae-hyun;Wang, Duck Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.10
    • /
    • pp.88-94
    • /
    • 2021
  • Machining operations require the removal of chips to keep the water-soluble cutting oil clean and fresh throughout the operation time. Water-soluble cutting oil for metal processing is diluted using a 3-8% solution in water which is generally replaced every three to six months. This study aims to develop multiple purification devices to efficiently remove fine contaminating particles from water-soluble cutting oil. The 2D concept designs were created using AutoCAD. The designs were drawn using the 3D modelling feature of CATIA. Flow analysis was performed in a bubble purifier using Ansys computational fluid dynamics (CFD). This analysis has aided in improving the design and structure of the device to create the final prototype. Experiments were conducted to check the prototype's performance. Comparisons of the effects of each process variable on the experiment was carried out using ANOVA.

Ex vivo Morphometric Analysis of Coronary Stent using Micro-Computed Tomography (미세단층촬영기법을 이용한 관상동맥 스텐트의 동물 모델 분석)

  • Bae, In-Ho;Koh, Jeong-Tae;Lim, Kyung-Seob;Park, Dae-Sung;Kim, Jong-Min;Jeong, Myung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.93-98
    • /
    • 2012
  • Micro-computed tomography (microCT) is an important tool for preclinical vascular imaging, with micron-level resolution. This non-destructive means of imaging allows for rapid collection of 2D and 3D reconstructions to visualize specimens prior to destructive analysis such as pathological analysis. Objectives. The aim of this study was to suggest a method for ex vivo, postmortem examination of stented arterial segments with microCT. And ex vivo evaluation of stents such as bare metal or drug eluting stents on in-stent restenosis (ISR) in rabbit model was performed. The bare metal stent (BMS) and drug eluting stent (DES, paclitaxel) were implanted in the left or right iliac arteries alternatively in eight New Zealand white rabbits. After 4 weeks of post-implantation, the part of iliac arteries surrounding the stent were removed carefully and processed for microCT. Prior to microCT analysis, a contrast medium was loaded to lumen of stents. All samples were subjected to an X-ray source operating at 50 kV and 200 ${\mu}A$ by using a 3D isotropic resolution. The region of interest was traced and measured by CTAN analytical software. Objects being exposed to radiation had different Hounsfield unit each other with values of approximately 1.2 at stent area, 0.12 ~ 0.17 at a contrast medium and 0 ~ 0.06 at outer area of stent. Based on above, further analyses were performed. As a result, the difference of lengths and volumes between expanded stents, which may relate to injury score in pathological analysis, was not different significantly. Moreover, ISR area of BMS was 1.6 times higher than that of DES, indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. And ISR area of BMS was higher ($1.52{\pm}0.48mm^2$) than that of DES ($0.94{\pm}0.42mm^2$), indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. Though it was not statistically significant, it showed that the extent of neointema of mid-region of stents was relatively higher than that of anterior and posterior region in parts of BMS as showing cross-sectional 2-D image. suggest that microCT can be utilized as an accessorial tool for pathological analysis.

Development of Microchip Removal Equipment Using Neodymium Permanent Magnets (네오디뮴 영구자석을 이용한 미세칩 제거장치의 개발)

  • Choi, Sung-Yun;Wang, Jun-hyeong;Wang, Duck Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.3
    • /
    • pp.122-128
    • /
    • 2021
  • Machining operations require removal of chips to keep the coolant clean and fresh throughout the operation time. In this study, microchip removal equipment was developed using AutoCAD and CATIA programs for 3D modeling and 2D draft. In addition, the flow analysis and electromagnetic field analysis of the equipment were performed using the COMSOL Multiphysics program. The flow design of the coolant oil tank was realized on the basis of fluid analysis results. Further, on the basis of magnetic density analysis, a conveyer was designed for effectively removing metal microchips in the tank by using arrays of neodymium permanent magnets.