Composition and magnetic ProPerties of CoFecu alloys according to electrolysis conditions (전해조건에 따른 CoFeCu 함금박막의 조성, 우선방위 및 자기적 특성)

  • 예길촌
    • Journal of the Korean institute of surface engineering
    • /
    • v.30 no.1
    • /
    • pp.3-12
    • /
    • 1997
  • The composition, the preferred orientation and the magnetic properties of the CoFeCu alloys electrodepositen under various electrolysis conditions in sulfate baths ware investigated. As the D.C. current density increased, the Co content in alloy electrodeposits increased, while the Cu content decreased and Fe content remained content. The effect of magnetic field up to 300 Oe on the composition of alloys was negligible. The Cu content of the alloys deposited in pulse current increased noticeably with increasing off-time, while the Co and Fe content decreased. The coercivity of the alloys with 3.5 to 7.0wt.% Cu was 1.0 to 2.0 Oe, but increased noticeably above and below that composition. The application of magnetic field during deposition decreased the coercivity of alloys. The saturation flux density of the alloys with 3.5 to 5.0wt.% Cu was relatively high in the range from 16 to 20.7Gauss. The anisotropy field(HK) of the alloys deposited under the magnetic field(50∼300 Oe) ranged from 18 to 22 Oe. The alloys had fcc structure with (111) preferred orientation, whose distribution increased a little with increasing magnetic field.

  • PDF

Manufacturing Prototype and Characteristics Analysis of Disk type Single Phase SRM by 3D Finite Element Method (3차원 FEM 해석에 의한 디스크형 단산 SRM의 시작기 제작과 특성 해석)

  • Lee, Jong-Han;O, Yeong-Ung;Im, Su-Saeng;Lee, Eun-Ung
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.6
    • /
    • pp.316-321
    • /
    • 1999
  • Disk type single phase switched reluctance motor which is a simple robust construction, simple control circuit and low manufacturing cost, has a characteristics of axial and radial flux machines. However, because this DSPSRM has a complicated magnetic circuit, it is difficult to analyze the design characteristics.. In this study, the calculation of design parameter based on the conventional design theory of electric machine and the characteristics analysis by computer simulation was performed. As the DSPSRM has the characteristics of both AFM and RFM, it is difficult to analyze its characteristics by the 2D FEM. 3D FEM was applied in the analysis of energy distribution and approximated calculation of torque characteristics with rotor positions. With analysis results, prototype of DSPSRM is manufactured.

  • PDF

Electromagnetic distribution looped Electrodeless Fluorescent Lamps (환형 무전극 램프의 전자계 분포특성)

  • Jo, Ju-Ung;Lee, Seong-Jin;Choi, Yong-Sung;Kim, Yong-Kab;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.312-315
    • /
    • 2003
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. Above all, the advantage of ring-shaped electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. The ring-shaped electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. Therefore, the life time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours. In this paper, maxwell 3D finite element analysis program (Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250[kHz] and some specific conditions.

  • PDF

The Optimal Design and Leakage Flux Analysis of the Induction Heating Cooker (유도가열조리기의 최적설계 및 누설자속 해석)

  • Byun, Jin-Kyu;Park, Il-Han;Choi, Kyung;Jung, Hyun-Kyo;Hahn, Song-Yop;Roh, Hee-Succ;Kwon, Kyoung-An;Yang, Woo-Jong
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.157-159
    • /
    • 1996
  • For the optimal design of the induction heating cooker, precise and accurate analysis of the magnetic field inside the jar must be achieved first. Until now, design methods based on experience has been used in industry field. But this takes a lot of trial and error, high cost and also long development time. So the analysis of the magnetic field distribution is very important. In this paper the magnetic field inside the induction heating cooker is analyzed by using axisymmetrical FEM(finite element method). And the method of the coil location design for the optimal heat source distribution using sensitivity analysis is developed. In addition, the shielding effect of the non-axisymmetrical 3-D ferrite structure used in induction heating cooker is also analyzed by the integral method.

  • PDF

An MHD Simulation of the X2.2 Solar Flare on 2011 February 15

  • Inoue, Satoshi;Choe, Gwangson
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.69.1-69.1
    • /
    • 2014
  • We perform an MHD simulation combined with observed vector field data to clarify an eruptive dynamics in the solar flare. We first extrapolate a 3D coronal magnetic field under a Nonlinear Force-Free Field (NLFFF) approximation based on the vector field, and then we perform an MHD simulation where the NLFFF prior to the flare is set as an initial condition. Vector field was obtained by the Soar Dynamics Observatory (SDO) at 00:00 UT on February 15, which is about 90 minutes before the X2.2-class flare. As a result, the MHD simulation successfully shows an eruption of strongly twisted lines whose values are over one-turn twist, which are produced through the tether-cut magnetic reconnection in strongly twisted lines of the NLFFF. Eventually, we found that they exceed a critical height at which the flux tube becomes unstable to the torus instability determining the condition that whether a flux tube might escape from the overlying field lines or not. In addition to these, we found that the distribution of the observed two-ribbon flares is similar to the spatial variance of the footpoints caused by the reconnection of the twisted lines being resided above the polarity inversion line. Furthermore, because the post flare loops obtained from MHD simulation well capture that in EUV image taken by SDO, these results support the reliability of our simulation.

  • PDF

Simulation study of magnetorheological testing cell design by incorporating all basic operating modes

  • Mughni, Mohd J.;Mazlan, Saiful A.;Zamzuri, Hairi;Yazid, Izyan I.M.;Rahman, Mohd A.A.
    • Smart Structures and Systems
    • /
    • v.14 no.5
    • /
    • pp.901-916
    • /
    • 2014
  • Magnetorheological (MR) fluid is one of the field-responsive fluids that is of interest to many researchers due to its high yield stress value, which depends on the magnetic field strength. Similar to electrorheological (ER) fluid, the combination of working modes is one of the techniques to increase the performance of the fluids with limited focus on MR fluids. In this paper, a novel MR testing cell incorporated with valve, shear and squeeze operational modes is designed and constructed in order to investigate the behaviour of MR fluid in combined mode. The magnetic field distribution in the design concept was analyzed using finite element method in order to verify the effective areas of each mode have the acceptable range of flux density. The annular gap of valve and shear were fixed at 1 mm, while the squeeze gap between the parallel circular surfaces was varied up to 20 mm. Three different coil configurations, which were made up from 23 SWG copper wires were set up in the MR cell. The simulation results indicated that the magnetic field distributed in the squeeze gap was the highest among the other gaps with all coils were subjected to a constant applied current of 1 A. Moreover, the magnetic flux densities in all gaps were in a good range of magnitude based on the simulations that validated the proposed design concept. Hence, the 3D model of the MR testing cell was designed using Solidworks for manufacturing processes.

Characteristic Analysis of Double-side Linear Pulst Motor (양측식 리니어 펄스 모터의 특성 해석)

  • Kim, Sung-Jong;Lee, Eun-Woong;Kim, Sung-Hun;Lee, Dong-Joo;Woo, Sung-Bong;Kim, Jun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.232-234
    • /
    • 2000
  • Double-side LPM may be replaced the solenoid as the valve driving device with out difficulty and give full play to control the valve accurately. Double-side LPM's magnetic structure is so complex by the cubic effect configuration that finite element analysis is required. Thus, in this paper, by 2D and 3D finite element analysis, we get the flux distribution and static thrust force curves of designed double side LPM.

  • PDF

Step-Up Asymmetrical Nine Phase Delta-Connected Transformer for HVDC Transmission

  • Ammar, Arafet Ben;Ammar, Faouzi Ben
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1920-1929
    • /
    • 2018
  • In order to provide a source for nine phases suitable for 18-pulse ac to dc power, this paper proposes a new structure for a step-up asymmetrical delta-connected transformer for converting three-phase ac power to nine-phase ac power. The design allows for symmetry between the nine output voltages to improve the power quality of the supply current and to minimize the THD. The results show that this new structure proves the equality between the output voltages with $40^{\circ}-{\alpha}$ and $40^{\circ}+{\alpha}$ phase shifting and produces symmetrical output currents. This result in the elimination of harmonics in the network current and provides a simulated THD that is equal to 5.12 %. An experimental prototype of the step-up asymmetrical delta-autotransformer is developed in the laboratory and the obtained results give a network current with a THD that is equal to 5.35%. Furthermore, a finite element analysis with a 3D magnetic field model is made based on the dimensions of the 4kVA, 400 V laboratory prototype three-phase with three-limb delta-autotransformer with a six-stacked-core in each limb. The magnetic distribution flux, field intensity and magnetic energy are carried out under open-circuit operation or load-loss.

HTS Josephson Junctions with Deionized Water Treated Interface (증류수 계면처리를 이용한 고온초전도체 죠셉슨 접합 제작)

  • Moon, S.H.;Park, W.K.;Kye, J.I.;Park, J.D.;Oh, B.
    • Progress in Superconductivity
    • /
    • v.2 no.2
    • /
    • pp.76-80
    • /
    • 2001
  • We have fabricated YBa$_2$Cu$_3$$O_{7-x}$ (YBCO) ramp-edge Josephson junctions by modifying ramp edges of the base electrodes without depositing any artificial barrier layer. YBa$_2$Cu$_3$O/7-x//SrTiO$_3$ (YBCO/STO) films were deposited on SrTiO$_3$(100) by on-axis KrF laser deposition. After patterning the bottom YBCO/STO layer, the ramp edge was cleaned by ion-beam and then reacted with deionized water under various conditions prior to the deposition of counter-electrode layers. The top YBCO/STO layer was deposited and patterned by photolithography and ion milling. We measured current-voltage (I-V) characteristics, magnetic field modulation of the critical current at 77 K. Some showed resistively shunted junction (RSJ)-type I-V characteristics, while others exhibited flux-flow behaviors, depending on the dipping time of the ramp edge in deionized water. Junctions fabricated using optimized conditions showed fairly uniform distribution of junction parameters such as I$_{c}$R$_{n}$ values, which were about 0.16 mV at 77 K with 1$\sigma$~ 24%. We made a dc SQUID with the same deionized water treated junctions, and it showed the sinusoidal modulation under applied magnetic field at 77 K. 77 K.

  • PDF

Development of 460V/225A/50㎄ Contact System in Current Limiting Molded Case Circuit Breakers

  • Park, Young-Kil;Park, Chan-Kyo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.4
    • /
    • pp.165-172
    • /
    • 2003
  • Low voltage circuit breakers are widely used in power distribution systems to interrupt fault current rapidly and to assure the reliability of the power supply. This paper is focused on understanding the interrupting capability, more specifically of the contacts and the arc runner, based on the shape of the contact system in the current molded case circuit breaker (hereafter MCCB). Moreover, in order to improve the interrupting capability of the circuit breaker, the estimation and analysis of the interrupting capability, based on the 3-D magnetic flux analysis, were developed. Furthermore, this paper also presents results of the estimation and analysis of the interrupting capability when applied to different model breakers. In addition, this paper analyzes the efficiency of the interrupting tests by forming false current paths consisting of a three-division cascade arc runner in the contact system. With regards to the interrupting test, there is a need to assure that the optimum design required to analyze the electromagnetic forces of the contact system generated by the current and flux density be present. Based on the results of this study, this paper presents both computational analysis and test results for the newly developed MCCB 460V/225A/50㎄ contact system.