• Title/Summary/Keyword: 3D imaging technique

Search Result 263, Processing Time 0.03 seconds

High-speed Three-dimensional Surface Profile Measurement with the HiLo Optical Imaging Technique

  • Kang, Sewon;Ryu, Inkeon;Kim, Daekeun;Kauh, Sang Ken
    • Current Optics and Photonics
    • /
    • v.2 no.6
    • /
    • pp.568-575
    • /
    • 2018
  • Various techniques to measure the three-dimensional (3D) surface profile of a 3D micro- or nanostructure have been proposed. However, it is difficult to apply such techniques directly to industrial uses because most of them are relatively slow, unreliable, and expensive. The HiLo optical imaging technique, which was recently introduced in the field of fluorescence imaging, is a promising wide-field imaging technique capable of high-speed imaging with a simple optical configuration. It has not been used in measuring a 3D surface profile although confocal microscopy originally developed for fluorescence imaging has been adapted to the field of 3D optical measurement for a long time. In this paper, to the best of our knowledge, the HiLo optical imaging technique for measuring a 3D surface profile is proposed for the first time. Its optical configuration and algorithm for a precisely detecting surface position are designed, optimized, and implemented. Optical performance for several 3D microscale structures is evaluated, and it is confirmed that the capability of measuring a 3D surface profile with HiLo optical imaging technique is comparable to that with confocal microscopy.

3D Interaction Technique on Stereo Display System

  • Kwon, Yong-Moo;Ki, Jeong-Seok;Jeon, Kyeong-Won;Kim, Sung-Kyu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1235-1238
    • /
    • 2007
  • There are several researches on 2D gaze tracking techniques to the 2D screen for the Human-Computer Interaction. However, the researches for the gaze-based interaction to the stereo images or 3D contents are not reported. This paper presents a gaze-based 3D interaction technique on autostereoscopic display system.

  • PDF

Three-Dimensional Imaging and Display through Integral Photography

  • Navarro, Hector;Dorado, Adrian;Saavedra, Genaro;Corral, Manuel Martinez
    • Journal of information and communication convergence engineering
    • /
    • v.12 no.2
    • /
    • pp.89-96
    • /
    • 2014
  • Here, we present a review of the proposals and advances in the field of three-dimensional (3D) imaging acquisition and display made in the last century. The most popular techniques are based on the concept of stereoscopy. However, stereoscopy does not provide real 3D experience, and produces discomfort due to the conflict between convergence and accommodation. For this reason, we focus this paper on integral imaging, which is a technique that permits the codification of 3D information in an array of 2D images obtained from different perspectives. When this array of elemental images is placed in front of an array of microlenses, the perspectives are integrated producing 3D images with full parallax and free of the convergence-accommodation conflict. In the paper we describe the principles of this technique, together with some new applications of integral imaging.

Resolution improvement of 3D images in plane-based computational integral imaging reconstruction technique (평면기반 컴퓨터 집적 영상 재생 방법에서 3차원 영상의 해상도 개선)

  • Shin, Dong-Hak
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.10
    • /
    • pp.1944-1949
    • /
    • 2007
  • In this paper, a new plane-based computational reconstruction technique for three-dimensional (3D) objects in 3D internal imaging based on a lens model is proposed. For the proposed technique, computational experiments have been carried out for various test images. Resolution of the reconstructed images is analyzed and compared with that obtained by the conventional technique. From experiments, it is shown that the resolution of a 3-D reconstructed image was improved by using the proposed technique.

A Novel 3-D Imaging Configuration Exploiting Synthetic Aperture Ladar

  • Guo, Liang;Huang, Yinli;Li, Xiaozhen;Zeng, Xiaodong;Tang, Yu;Xing, Mengdao
    • Current Optics and Photonics
    • /
    • v.1 no.6
    • /
    • pp.598-603
    • /
    • 2017
  • Traditional three-dimensional (3-D) laser imaging systems are based on real aperture imaging technology, whose resolution decreases as the range increases. In this paper, we develop a novel 3-D imaging technique based on the synthetic aperture technology in which the imaging resolution is significantly improved and does not degrade with the increase of the range. We consider an imaging laser radar (ladar) system using the floodlight transmitting mode and multi-beam receiving mode. High 3-D imaging resolutions are achieved by matched filtering the linear frequency modulated (LFM) signals respectively in range, synthetic aperture along-track, and the real aperture across-track. In this paper, a novel 3-D imaging signal model is given first. Because of the motion during the transmission of a sweep, the Doppler shift induced by the continuous motion is taken into account. And then, a proper algorithm for the 3-D imaging geometry is given. Finally, simulation results validate the effectiveness of the proposed technique.

Improved Viewing Quality of 3-D Images in Computational Integral Imaging Reconstruction Based on Lenslet Array Model

  • Shin, Dong-Hak;Lee, Byoung-Ho;Kim, Eun-Soo
    • ETRI Journal
    • /
    • v.28 no.4
    • /
    • pp.521-524
    • /
    • 2006
  • In this letter, we propose a novel computational integral imaging reconstruction technique based on a lenslet array model. The proposed technique provides improvement of viewing images by extracting multiple pixels from elemental images according to ray tracing based on the lenslet array model. To show the feasibility of the proposed technique, we analyze it according to ray optics and present the experimental results.

  • PDF

Three-Dimensional Photon Counting Imaging with Enhanced Visual Quality

  • Lee, Jaehoon;Lee, Min-Chul;Cho, Myungjin
    • Journal of information and communication convergence engineering
    • /
    • v.19 no.3
    • /
    • pp.180-187
    • /
    • 2021
  • In this paper, we present a computational volumetric reconstruction method for three-dimensional (3D) photon counting imaging with enhanced visual quality when low-resolution elemental images are used under photon-starved conditions. In conventional photon counting imaging with low-resolution elemental images, it may be difficult to estimate the 3D scene correctly because of a lack of scene information. In addition, the reconstructed 3D images may be blurred because volumetric computational reconstruction has an averaging effect. In contrast, with our method, the pixels of the elemental image rearrangement technique and a Bayesian approach are used as the reconstruction and estimation methods, respectively. Therefore, our method can enhance the visual quality and estimation accuracy of the reconstructed 3D images because it does not have an averaging effect and uses prior information about the 3D scene. To validate our technique, we performed optical experiments and demonstrated the reconstruction results.

Three-Dimensional Surface Imaging is an Effective Tool for Measuring Breast Volume: A Validation Study

  • Lee, Woo Yeon;Kim, Min Jung;Lew, Dae Hyun;Song, Seung Yong;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • v.43 no.5
    • /
    • pp.430-437
    • /
    • 2016
  • Background Accurate breast volume assessment is a prerequisite to preoperative planning, as well as intraoperative decision making in breast reconstruction surgery. The use of three-dimensional surface imaging (3D scanning) to assess breast volume has many advantages. However, before employing 3D scanning in the field, the tool's validity should be demonstrated. The purpose of this study was to confirm the validity of 3D-scanning technology for evaluating breast volume. Methods We reviewed the charts of 25 patients who underwent breast reconstruction surgery immediately after total mastectomy. Breast volumes using the Axis Three 3D scanner, water-displacement technique, and magnetic resonance imaging (MRI) were obtained bilaterally in the preoperative period. During the operation, the tissue removed during total mastectomy was weighed and the specimen volume was calculated from the weight. Then, we compared the volume obtained from 3D scanning with those obtained using the water-displacement technique, MRI, and the calculated volume of the tissue removed. Results The intraclass correlation coefficient (ICC) of breast volumes obtained from 3D scanning, as compared to the volumes obtained using the water-displacement technique and specimen weight, demonstrated excellent reliability. The ICC of breast volumes obtained using 3D scanning, as compared to those obtained by MRI, demonstrated substantial reliability. Passing-Bablok regression showed agreement between 3D scanning and the water-displacement technique, and showed a linear association of 3D scanning with MRI and specimen volume, respectively. Conclusions When compared with the classical water-displacement technique and MRI-based volumetry, 3D scanning showed significant reliability and a linear association with the other two methods.

Three-Dimensional Map System Using Integral Imaging Technique (집적 영상 기술을 이용한 3차원 지도 시스템)

  • Cho, Myungjin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.11
    • /
    • pp.2799-2804
    • /
    • 2014
  • In this paper, we suggest three-dimensional information extraction map system using integral imaging technique. Integral imaging can record multiple elemental images with different perspectives using a 2D image acquisition device with lenslet array. Using these images, integral imaging can obtain 3D information and display 3D image. In this paper, the position difference between elemental images can be obtained using summation of absolute difference (SAD), and then 3D information can be extracted. Therefore, this technique can find the height information of 3D objects.

3D Microwave Imaging Technology for Damage Detection of Concrete Structures (콘크리트 구조물의 결함발견을 위한 3차원 초단파 영상처리기법의 개발)

  • Kim, Yoo-Jin;Kim, Yong-Gon
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.4
    • /
    • pp.98-104
    • /
    • 2003
  • Various nondestructive evaluation (NDE) techniques have been studied to locate steel rebars of dowel, and to detect invisible damage such as voids and cracks inside concrete and debonding between rebars and concrete caused by corrosions and earthquakes. In this study, the aurhors developed 3-dimensional (3D) electromagnetic (EM) imaging technology to detect such damage and to identify exact location of steel rebars of dowel. The authors have developed sub-surface two-dimensional (2D) imaging technique using tomographic antenna array in previous works. In this study, extending the earlier analytical and experimental works on 2D image reconstruction, a 3D microwave imaging system using tomographic antenna array was developed, and multi-frequency technique was applied to improve quality of the reconstructed image and to reduce background noises. This paper presents the analytical expressions of numerical focusing procedures for 3D image reconstruction and numerical simulation to study the resolution of the system and the effectiveness of multi-frequency technique. Also, the design of 4?4 antenna array with switching devices is introduced as a preliminary study for the final design of whole array.