• Title/Summary/Keyword: 3D gait analysis

Search Result 116, Processing Time 0.029 seconds

Reliability of 3D-Inertia Measurement Unit Based Shoes in Gait Analysis (관성센서 기반 신발형 보행 분석기의 신뢰성 연구)

  • Joo, Ji-Yong;Kim, Young-Kwan;Park, Jae-Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.1
    • /
    • pp.123-130
    • /
    • 2015
  • Purpose : The purpose of this study was to investigate the reliability of 3D-inertia measurement unit (IMU) based shoes in gait analysis. This was done with respect to the results of the optical motion capturing system and to collect reference gait data of healthy subjects with this device. Methods : The Smart Balance$^{(R)}$ system of 3D-IMU based shoes and Osprey$^{(R)}$ motion capturing cameras were used to collect motion data simultaneously. Forty four healthy subjects consisting of individuals in 20s (N=20), 40s (N=13), and 60s (N=11) participated in this study voluntarily. They performed natural walking on a treadmill for one minute at 4 different target speeds (3, 4, 5, 6 km/h), respectively. Results : Cadence (ICC=.998), step length (ICC=.970), stance phase (ICC=.845), and double-support phase (ICC=.684) from 3D-IMU based shoes were in agreement with results of optical motion system. Gait data of healthy subjects according to different treadmill speeds and ages were matched to previous literature showing increased cadence and reduced step length for elderly subjects. Conclusion : Conclusively, 3D-IMU based shoes in gait analysis were a satisfactory alternative option in measuring linear gait parameters.

Study on Gait Analysis of Elders and Hemiplegia Patients using 3D Motion Analysis (고령자 및 편마비 환자의 3 차원 동작분석을 통한 보행 특성에 관한 연구)

  • Jang, Hye-Youn;Han, Jung-Soo;Han, Chang-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.7
    • /
    • pp.730-736
    • /
    • 2012
  • Latest, many researchers do research on wearable robot. The purpose of the researches is very diverse, it will improve efficiency in the industry, taken to replace the many workers in the military field and taken to assist bodily functions run out by aging. However, there is no clear Differentiated strategy depending on the purpose for design and control of the wearable robot. Although a common purpose is to drive the robot by the sensor signal (intent signals), the optimization about the mechanism and control studies must be done according to the user's physical ability and purpose. In this study, the study's first phase for the development of wearable robotic gait rehabilitation, gait characteristics were analyzed elders and hemiplegia patients using a 3D gait analysis system (VICON512). As a result, asymmetric gait characteristics of the hemiplegia patients were found compared with the normal elderly.

Evaluation of Ergonomic Performance of Medical Smart Insoles

  • Yi, Jae-Hoon;Lee, Jin-Wook;Seo, Dong-Kwon
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.2
    • /
    • pp.215-223
    • /
    • 2022
  • Objective: This study was to resolve the limitations of the experimental environment and to solve the shortcomings of the method of measuring human gait characteristics using optical measuring instruments. Design: A cross-sectional study. Methods: Fifteen healthy adults without a history of orthopedic surgery on the lower extremities for the past 6 months were participated. They were analyzed gait variables using the smart guide and the 3D image analysis at the same time, and their results were compared. Visual-3D was used to calculate the analysis variables. Results: The reliability and validity of the data according to the two measuring instruments were found to be very high; gait speed(0.85), cycle time(0.99), stride time of both feet(0.98, 0.97) stride legnth of both feet(0.86, 0.88) stride per minute of both feet(0.99, 0.96), foot speed of both feet(0.90, 0.91), step time of both feet(0.77, 0.71), step per minute(0.72, 0.74), stance time of both feet(0.96, 0.97), swing time of both feet(0.93, 0.79), double step time(0.81), initial double step time(0.84) and terminal step time(0.76). Conclusions: In the case of the smart insole, which measures human gait variables using the pressure sensor and inertial sensor inserted in the insole, the reliability and validity of the measured data were found to be very high. It can be used as a device to replace 3D image analysis when measuring pathological gait.

Validation on the Application of Bluetooth-based Inertial Measurement Unit for Wireless Gait Analysis (무선 보행 분석을 위한 블루투스 기반 관성 측정 장치의 활용 타당성 분석)

  • Hwang, Soree;Sung, Joohwan;Park, Heesu;Han, Sungmin;Yoon, Inchan
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.3
    • /
    • pp.121-127
    • /
    • 2020
  • The purpose of this paper is to review the validation on the application of low frequency IMU(Inertial Measurement Unit) sensors by replacing high frequency motion analysis systems. Using an infrared-based 3D motion analysis system and IMU sensors (22 Hz) simultaneously, the gait cycle and knee flexion angle were measured. And the accuracy of each gait parameter was compared according to the statistical analysis method. The Bland-Altman plot analysis method was used to verify whether proper accuracy can be obtained when extracting gait parameters with low frequency sensors. As a result of the study, the use of the new gait assessment system was able to identify adequate accuracy in the measurement of cadence and stance phase. In addition, if the number of gait cycles is increased and the results of body anthropometric measurements are reflected in the gait analysis algorithm, is expected to improve accuracy in step length, walking speed, and range of motion measurements. The suggested gait assessment system is expected to make gait analysis more convenient. Furthermore, it will provide patients more accurate assessment and customized rehabilitation program through the quantitative data driven results.

User Experience Analysis of a Shoe-mounted Gait Analysis Tracker (신발장착형 보행분석 트래커의 사용자경험 분석)

  • Kim, Siyeon;Jung, Dahee;Lee, Joo-Young;Kwon, Jihyun;Lim, Daeyoung;Jeong, Wonyoung
    • Fashion & Textile Research Journal
    • /
    • v.23 no.3
    • /
    • pp.390-405
    • /
    • 2021
  • Gait analysis trackers have been developed to monitor daily gait patterns to improve users' running performance and reduce the risk of injuries. A variety of gait analysis trackers are available on the market(e.g., foot pods, insoles). Depending on the type of gait analysis tracker, users' discomfort or satisfaction as well as required properties may differ. Hence, the purpose of this study was to compare and analyze user experience of three different types of commercial shoe-mounted gait analysis trackers and their mobile applications in a laboratory environment using questionnaires based on actual experiences of each product. Ten males and ten females who regularly enjoy walking and running exercises participated in the experiment. After the participants set up the tracker and application themselves without support from researchers, ten to thirty minutes' exercise was permitted on each product. Following this, the participants answered questionnaires containing evaluation variables on the device and mobile application, as well as satisfaction, intention to use, recommendation, and purchase. In addition, they were asked questions about the attractive features and shortcomings of each device and application. The results showed that the PRO-SPECS® smart insole was preferred over the others for ease of use, perceived durability, psychological burden of the design, and usefulness of the information provided by the application. Along with the results of questionnaire, this study also discussed strategies and recommendations for future product design and development.

A Study of Gait and Gait Analysis Techniques (보행과 보행분석법에 관한 연구)

  • Bae Sung-Soo;Lee Jin-Hee;Yoon Chang-Goo
    • The Journal of Korean Physical Therapy
    • /
    • v.8 no.1
    • /
    • pp.49-64
    • /
    • 1996
  • The technology of gait analysis is moving rapidly. Human gait is very complex, and a through understanding of it demands with the basic principles of biomechanics and the technology used to measure gait. Some professionals reluctance to use gait analysis may be due to the amount of time and effort necessary to accomplish this and the necessity for teamwork among the disciplines involved. Any form of observational gait analysis has limited precision and is more descriptive than quantative. The techniques of 3-D kinetic and kinematic analysis can provide a detailed biomechanical description of normal and pathological gait. This article review gait characteristics and procedures that are available for gait analysis. We are certain that, given the steady advance of technology and our continued efforts to document the benefits of that technology. gait analysis will soon be a routine part of the evaluation of both the elite athlete and the physically impaired adult or child.

  • PDF

Gait analysis methods and walking pattern of hemiplegic patients after stroke (뇌졸중환자의 보행분석방법과 보행특성)

  • Han, Jin-Tae;Bae, Sung-Soo
    • PNF and Movement
    • /
    • v.5 no.1
    • /
    • pp.37-47
    • /
    • 2007
  • Objective : A large proportion of stroke survivors have to deal with problems in gait. Proper evaluation of gait must be undertaken to understand the sensorimotor impairment underlying locomotor disorders post stroke. Methods : The characteristics of gait pattern with post stroke are reviewed in this paper. In particular, temporal distance parameters, kimematics, kinetics, as well as energy cost, EMG are focused. Results : The technology for gait analysis is moving rapidly. The techniques of 3D kinematic and kinetic analysis can provide a detailed biomechanical description of normal and pathological gait. This article reviews gait analysis method and characteristics of post stroke. Finally current method of gait analysis can provide further insight to understand paretic gait and therapeutic direction.

  • PDF

Feasibility Study of Gait Recognition Using Points in Three-Dimensional Space

  • Kim, Minsung;Kim, Mingon;Park, Sumin;Kwon, Junghoon;Park, Jaeheung
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.13 no.2
    • /
    • pp.124-132
    • /
    • 2013
  • This study investigated the feasibility of gait recognition using points on the body in three-dimensional (3D) space based on comparisons of four different feature vectors. To obtain the point trajectories on the body in 3D, gait motion data were captured from 10 participants using a 3D motion capture system, and four shoes with different heel heights were used to study the effects of heel height on gait recognition. Finally, the recognition rates were compared using four methods and different heel heights.

3D Gait Analysis of Limb Salvage Patients with Osteoarticular Knee Allograft Reconstruction (슬관절 동종골을 이용한 사지 구제수술 환자의 3차원 보행분석)

  • Jang, Ik-Gyu;Park, Hong-Seong;Nam, Kyoung-Won;Hong, Man-Bok;Kim, Soo-Hyun;Kim, Han-Soo;Kang, Hyun-Guy;Kim, Kwang-Gi
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.1
    • /
    • pp.74-80
    • /
    • 2010
  • This paper presents the three dimensional gait analysis of the patients with osteoarticular knee allograft reconstruction. The gait analysis has been performed in some medical fields such as orthopedics and neurosurgery for the purpose of the rehabilitation of patients. However, to the author's knowledge, the analysis of gait for the patients with osteoarticular knee allograft reconstruction caused by tumor has not been reported. In this work, In this work, we confirmed the validity of this method by analyzing 50 samples per one gait cycle obtained from each of 3 patients and 3 normal persons. The motion capture was performed using six infrared cameras. The symmetry and stability of the gait patterns are investigated (patients' r=0.39, p<0.05, normal persons' r=0.65, p<0.05) respectively using the correlation coefficients and the standard deviations of the joint angles of the left and right legs. It also would be applied to the comparison analysis where artificial knee joint is transplanted.

Relationship between 3D Ground Reaction Force and Leg Length Discrepancy during Gait among Standing Workers

  • Kim, Yong-Wook
    • PNF and Movement
    • /
    • v.20 no.1
    • /
    • pp.59-66
    • /
    • 2022
  • Purpose: The aim of this research was to verify the relationship between three-dimensional (3D) ground reaction force (GRF) and severity of leg length discrepancy (LLD) while walking at a normal speed. It used a 3D motion analysis system with force platforms in standing workers with LLD. Methods: Subjects comprising 45 standing workers with LLD were selected. Two force platforms were used to acquire 3D GRF data based on a motion analysis system during gait. Vicon Nexus and Visual3D v6 Professional software were used to analyze kinetic GRF data. The subjects were asked to walk on a walkway with 40 infrared reflective markers attached to their lower extremities to collect 3D GRF data. Results: The results indicated the maximal force in the posterior and lateral direction of the long limb occurring in the early stance phase during gait had significant positive correlation with LLD severity (r = 0.664~0.738, p <0.01). In addition, the maximal force medial direction of the long limb occurring in the late stance phase showed a highly positive correlation with the LLD measurement (r = 0.527, p <0.01). Conclusion: Our results indicate that greater measured LLD severity results in more plantar pressure occurring in the foot area during heel contact to loading response of the stance phase and the stance push-off period during gait.