• Title/Summary/Keyword: 3D foot scan

Search Result 27, Processing Time 0.038 seconds

A Study on Foot Shape by 3D Data of Female High School Students (3차원 데이터에 의한 여고생의 발 형태에 관한 연구)

  • Lee, Jeong-Eun;Do, Wol-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.4
    • /
    • pp.572-583
    • /
    • 2014
  • This study analyzes the foot shape of female high school students using 3D foot scan data based on a comparison with adult women (20s'-30s'). Data were collected from the foot anthropometry of 199 female high school students in Gwangju and Jeollanam-do. The right foot was measured indirectly by 3D laser scanner. There are 16 items in the foot anthropometric measurements. The $6^{th}$ Size Korea (measured by 3D scan data) is used for women's foot data. The results of the 3D measurements data investigation show that the foot length and foot width became longer and wider as the age increased. It is classified by three types after analyzing foot shape. Type 1 (28.1%) represented the shortest foot length, the narrowest foot width as well as the thick foot and long ankle shape. Type 2 (4.3%) represented the wide foot width such as the wide lateral ball width and semi-thickness shape. Type 3 (67.7%) referred to the widest foot width, flat foot and short ankle shape.

The Height and Volume of Medial Longitudinal Arch in Normal and Painful Feet (정상인과 통증이 있는 족부의 내측 종아치의 높이와 부피)

  • Lee, Woo-Chun;Moon, Jeong-Seok
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.1
    • /
    • pp.8-12
    • /
    • 2007
  • Purpose: The purpose of this study was to investigate the differences in simple radiographic parameters and results of 3-D scan among normal and patient groups. Materials and Methods: Seventy subjects in each group were studied. Control group consisted of subjects without plantar foot pain (normal group), and two patient groups were one with plantar forefoot pain (metatarsalgia group), the other with plantar heel pain (heel pain group). Simple radiographic parameters were obtained and 3-D scan was done with foot scanner (Nexscan, K&I, Korea) and The height and volumn of the space under the medial longitudinal arch was analyzed (Enfoot, K&I, Korea). These parameters were compared and correlation between radiological parameters and results of the 3-D scan were studied. Results: The results of all parameters istributed normally. There was no signigicant differences among the groups in radiological parameters (talo-first metatarsal angle, calcaneal pitch angle and height of the talar head in standing lateral radiograph) and arch height and arch volumn on 3-D scan. There were statistically significant correlations between radiological and 3-D scan results. Conclusion: This study revealed that there is no significant differences in medial longitudinal arch height and volumn among normal and different patient groups and there are variety of arch height in patients with similar symptoms.

  • PDF

A 3D Foot Scanner Using Mirrors and Single Camera (거울 및 단일 카메라를 이용한 3차원 발 스캐너)

  • Chung, Seong-Youb;Park, Sang-Kun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.1
    • /
    • pp.11-20
    • /
    • 2011
  • A structured beam laser is often used to scan object and make 3D model. Multiple cameras are inevitable to see occluded areas, which is the main reason of the high price of the scanner. In this paper, a low cost 3D foot scanner is developed using one camera and two mirrors. The camera and two mirrors are located below and above the foot, respectively. Occluded area, which is the top of the foot, is reflected by the mirrors. Then the camera measures 3D point data of the bottom and top of the foot at the same time. Then, the whole foot model is reconstructed after symmetrical transformation of the data reflected by mirrors. The reliability of the scan data depends on the accuracy of the parameters between the camera and the laser. A calibration method is also proposed and verified by experiments. The results of the experiments show that the worst errors of the system are 2 mm along x, y, and z directions.

Analysis of Foot Shape and Size System of Male High School Students Using 3D Scan Data (3D 스캔 데이터를 활용한 남자 고등학생의 발 형태 및 치수체계 분석)

  • Shin, Yu Jin;Park, Soonjee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.1
    • /
    • pp.53-67
    • /
    • 2020
  • The purpose of this study is to analyze the foot shape and size specification of male high school students. 3D modeling programs such as 'Artec Studio', 'CATIA', and 'Auto CAD' measured the 3D scan data of 361 male high school students provided by KATS. Through principal factor analysis, 10 factors were extracted, including foot length, medial-lateral ratio, and foot length ratio. As the result of the cluster and ANOVA with post-hoc test (Duncan method), the differences among types were clarified. Type 1 (24.7%) represented outward medial-lateral ratio (M-L ratio) with the lowest instep, ankle and little deformed first toe. Type 2 (41.8%) was characterized by the shortest, even M-L ratio, thin ankle and heel, the highest instep and ankle. Type 3 (33.5%) showed the longest, inward M-L ratio, thick ankle and heel, and deformed first toe. As the cross-tabulation of foot length and ball circumference, 17.2 percent was not covered by KS standard; in addition, the foot length was longer than the KS standard. The correlation analysis of key dimensions showed that foot length and ball circumference were highly correlated with other items; therefore, regression equations were derived to estimate other foot measurements using these two items as independent variables.

Classification of Sole Types for Female High School Students by 2D scan data (2D 데이터에 의한 여고생의 발바닥 유형 분석)

  • Lee, Jeong-Eun;Do, Wol-Hee
    • Fashion & Textile Research Journal
    • /
    • v.15 no.6
    • /
    • pp.977-984
    • /
    • 2013
  • This study classified the type of sole for female high school students and analyzed the characteristics of each type by the shape of the sole (plantar view) using 2D scan data. The data were collected from a foot anthropometry of 310 female high school students in Gwangju and Jeollanam-do. Left feet and right feet were measured indirectly by using flatbed scanner. The sole anthropometric measurements consisted of 24 items. The results of the investigation into the differences between left and right feet soles by the 2D measurements data indicated that there was no significant statistical differences in the length of items. The left sole had higher values than right sole in the width items and angle items; however, the lateral side of the right feet projected to the outside more often than left feet. In analyzing foot sole of female high school students, the shapes of sole were classified into three types. Type 1(41.94%), Type 2(36.77%), Type 3(21.29%). The most characteristic sole type for female high school students was Type 1. Type 1 referred to a narrow foot width with little or no curvature of the toe. Type 2 represented the longest foot, with foot width shown as a spacious and distinctive feature in width at the medial area of the foot. Type 3 represented the shortest and widest of ball width, gathered inside toe 5, and lateral side as the most projected among the three types.

Classification of Elderly Men's Foot Side Type from 3D Scan Data (3차원 스캔 데이터에 의한 노년 남성의 발 측면유형 분류)

  • Kim, Nam-Soon;Do, Wol-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.4
    • /
    • pp.427-439
    • /
    • 2014
  • This study identifies the foot side shapes of elderly men by classifying foot types according to 3D foot shapes and analyzing individual characteristics. The subjects were 284 elderly men over 60 years of age who lived in Gwangju and did not have foot related diseases. They were measured with a scanner (Nexcan$^{(R)}$ of K&I Technology) to obtain three dimensional feet shapes. Anthropometric measuring items consisted of 28 items estimated on the right foot of each subject. 3D scan data were analyzed by various statistical methods such as factor analysis, ANOVA and cluster analysis using the statistical program SPSS 19.0. A total of 7 factors were extracted through a factor analysis and these factors represent 77.56% of total variance. The 8 factors were: inside height and side gradient, ankle thickness, size from foot center to ankle, lateral malleolus height, forefoot height, instep and heel height and gradient. A total of 3 clusters (as foot type) were categorized using 7 factor scores by cluster analysis. Type 1 was classified as high forefoot and low midfoot compared to the length. Type 2 was classified as low forefoot and high midfoot, and type 3 was classified as low forefoot and low midfoot.

Foot Type Classification of Korean Male Farmers for Ergonomic Work Shoes Design

  • Kim, Dohee;Hwang, Kyoung Suk;Lee, Kyung Suk
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.6
    • /
    • pp.773-783
    • /
    • 2012
  • Objective: The aim of this study is to identify foot shapes of Korean male farmers by classifying their foot types using 3D scan data and analyzing the characteristics of each type. Background: The increasing demands for anthropometric information for the design of machinery and personal protective equipment to prevent occupational injuries has necessitated an understanding of the anthropometric differences to be found among occupations. Static stooped posture and squatting posture are so common in Korean farmers that anthropometric deformation in foot especially seems to occur easily. Method: 366 Korean male farmers volunteered for this study from 16 different farming villages nationwide from 2009 to 2011. Subjects were categorized into 4 age groups from 40s to 70s. Their right feet were measured by using 3D foot scanner, the anthropometric dimensions were composed of 40 items. Results: The 8 major factors affecting the foot shapes were extracted. From these factors the foot shape of Korean male farmers was classified into 3 Foot types. Foot type 1 showed severe deformation in toe 1, type 2 had a narrow shape and type 3 had a wider width for its length. Conclusion: There were some differences in foot shape and types between farmers and the public. The most characteristic foot type in Korean male farmers was type 3. Application: The results of identifying foot shapes of Korean male farmers might provide the useful information for designing ergonomic farm work shoes.

Pressure Analysis of the Plantar Musculoskeletal Fascia Using a Fine Finite-Element Model (인체 족부 근골격계 상세 유한요소모델링을 통한 족저압 해석)

  • Jeon, Seong-Mo;Kim, Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.10
    • /
    • pp.1237-1242
    • /
    • 2011
  • The A detailed 3D finite-element analysis model of a human foot has been developed by converting CT scan images to 3D CAD models in order to analyze the distribution of plantar pressure. The 3D foot model includes all muscles, bones, and skin. On the basis of this model and the pressure distribution results, shoes for diabetes patients, which can make the plantar pressure distribution uniform, may be designed through finite-element contact analysis.

3D printed midsole design according to the sole types of elementary school students

  • Lim, Ho Sun
    • The Research Journal of the Costume Culture
    • /
    • v.24 no.3
    • /
    • pp.315-323
    • /
    • 2016
  • The present study is intended to study sole types necessary for shoe designs for elementary school students that are in age groups in growth periods, and 3D midsole design utilizing 3D printing technology. This study analyzed data from the 3D measurement of the feet of 1,227 elementary school students aged 7-13 years residing in the capital region conducted as part of the 6th Anthropometry of Size Korea. In addition, 3D midsoles by sole type were designed utilizing a Rhino CAD, and midsole prototypes were output utilizing a Zortrax-M200 3D Printer. Through a cluster analysis of sole shapes by type, sole shapes were classified into three types. Type 1 has small values of foot lengths and foot breadths, with large toe 1 angles and high arch heights. Type 2 has intermediate values of foot lengths and foot breadths, with small toe 1 angles and high arch heights. Type 3 has large values of foot lengths and foot breadths with small toe 1 angles and low arch heights. On reviewing the results of design of 3D midsoles by sole type, it can be seen that the midsoles were designed according to characteristics by sole type. The results of the sole type analysis in the present study are expected to be meaningful as basic data for the development of shoe insoles for elementary school students.