• Title/Summary/Keyword: 3D electric survey

Search Result 25, Processing Time 0.022 seconds

A Study on the Deep Structure of Yangsan Fault by Electric and Electromagnetic Surveys in Unyang and Bong-gye Areas, Kyeongnam Province, Korea (경상남도 언양 및 봉계리 지역에서의 전기, 전자탐사에 의한 양산단층의 심부구조 연구)

  • 손호웅;윤혜수;오진용
    • Economic and Environmental Geology
    • /
    • v.33 no.6
    • /
    • pp.525-536
    • /
    • 2000
  • Electromagnetic and electric surveys were performed to reveal the deep structure of the Yangsan fault in the Bong-gye and Unyang areas, Kyeongnam Province, Korea. Especially, high-frequency magnetotelluric (HFMT) method of EM survey was mainly employed to study the deep subsurface configuration of Yangsan fault. HFMT survey was performed at 25 points of spacing 50 m, making 1.3 km survey line in Unyang area and 13 points of spacing 50 m, making 0.6 km survey line in Bong-gye area. Two 2-D cross-sections (Unyang and Bong-gye areas) were achieved as results. Electric survey by dipole-dipole array was performed to study the structure of shallow subsurface and compare the results with HFMT surveys. The results of HFMT and electric surveys show that Yangsan fault is a geologic boundary. It is very narrow and steep (about $80^{\circ}C$), and extends to 1~1.5 km depth.

  • PDF

Deep structure of Ulsan fault by electric and EM surveys in ipsil area, South of Kyeongju (전기, 전자탐사에 의한 경주남부 (입실지역)의 울산 단층 심부구조)

  • 손호응
    • Economic and Environmental Geology
    • /
    • v.32 no.2
    • /
    • pp.161-167
    • /
    • 1999
  • Electric and electromagnetic surveys were conducted to investigate the deep structure of the Ulsan fault in Ipsil area, south of Kyeongju. On this study, especially high-frequency magnetotelluric method of electromagnetic survey in the frequency range of 10~100,000 Hz was mainly employed to study the deep subsurface configuration. High-frequency MT survey was performed at 70 points of spacing 30~50 m, making 3.8 km survey line. As a survey result, a 2-km-depth 2-D cross-section was achieved. It shows vertical and horizontal subsurface variations of resistivity values. Near-surface layer having low resistivity value becomes thicker eastward up to 800m. There is a steep low resistivity zone in the west side of survey line, and there exists two low resistivity zones dipping west in the east side of survey line. Two low resistivity zones are interpreted to be related to major movement pattern of the Ulsan fault. This suggests that major fault lines are developed on both peripheral sides of the broad fault zone.

  • PDF

An analysis of the measured electric and magnetic fields of transmission lines in Korea (전국의 송전선로 전자계 측정치와 계산치와의 비교 분석)

  • Kim, S.B.;Cho, S.B.;Shin, K.Y.;Lee, D.I.;Kim, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2368-2370
    • /
    • 1999
  • A nationwide survey for electric and magnetic fields(EMFs) near overhead transmission lines has been conducted. The median values of the electric and magnetic fields of 208 transmission lines were 0.50 kV/m and 12.6 mG, respectively. The maximum values were 3.16 kV/m and 125 mG. The measured EMFs were compared with the calculated ones. The causes of the discrepancy between measured and calculated EMFs are also discussed.

  • PDF

Creation of 3D Maps for Satellite Communications to Support Ambulatory Rescue Operations

  • Nakajima, Isao;Nawaz, Muhammad Naeem;Juzoji, Hiroshi;Ta, Masuhisa
    • Journal of Multimedia Information System
    • /
    • v.6 no.1
    • /
    • pp.23-30
    • /
    • 2019
  • A communications profile is a system that acquires information from communication links to an ambulance or other vehicle moving on a road and compiles a database based on this information. The equipment (six sets of HDTVs, fish-eye camera, satellite antenna with tracking system, and receiving power from the satellite beacon of the N-star) mounted on the roof of the vehicle, image data were obtained at Yokohama Japan. From these data, the polygon of the building was actually produced and has arranged on the map of the Geographical Survey Institute of a 50 m-mesh. The optical study (relationship between visibility rate and elevation angle) were performed on actual data taken by fish-eye lens, and simulated data by 3D-Map with polygons. There was no big difference. This 3D map system then predicts the communication links that will be available at a given location. For line-of-sight communication, optical analysis allows approximation if the frequency is sufficiently high. For non-line-of-sight communication, previously obtained electric power data can be used as reference information for approximation in certain cases when combined with predicted values calculated based on a 3D map. 3D maps are more effective than 2D maps for landing emergency medical helicopters on public roadways in the event of a disaster. Using advanced imaging technologies, we have produced a semi-automatic creation of a high-precision 3D map at Yokohama Yamashita Park and vicinity and assessed its effectiveness on telecommunications and ambulatory merits.

The Effect of Electromagnetic Fields Shielding on Electromagnetic Fields Decrease in P. T Room (차폐천이 물리치료실 환경내 전자기장 감소에 미치는 효과)

  • Lim Chang-Hun;Kim Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.12 no.2
    • /
    • pp.69-82
    • /
    • 2000
  • Physical therapists are exposured to radio-and microwave-frequency electromagnetic radiation by operating electrotherapy units. So there is few protection system in physical therapy room. Clinical pathology room and so on where various kins of electromagnetic instruments is used in hospital while protection failities like protection wall or protection glass is being used only in radiological room to reduce the damage of radiation. Acoording to Larsen's survey on female physical therapist in denmark. it was said that the percentage of congenital malfornation was $3.6\%$ and cadiac malformation made up $0.7\%$. It is likely that effect of electromagnetic fields on the result cannot be ruled out. Rita ouellet-Hellstron and Walter F. Steward insisted that the danger of abortion increase in the case of pregnant femeal physical therapist exposured to microwave diathermy. The intention of our study is arousing the necessity of microwave protection in P.T room and finding the proper method for physical therapist safe. The results of this study were as follows: 1. Each electrotherapy units are occurrenced the electromagnetic fields, and specially amply occurrenced in H.P,I.C.T 2 unit operating, M.W.D unit head on parallel, S.W.D unit head on parallel. all electrotherapy units are operating. 2. There were electric fields mount are consideration to species of electrotherapy units(p<.05). 3. There were magnetic fields mount are consideration to species of electrotherapy units(p<.05). 4. There were electric fields mount are consideration to distance of electrotherapy units(p<.05). 7. There were magnetic fields mount are consideration nut to distance of electrotherapy units(p>.05). 8. Before and after protection on magnetic fields mount are consideration to all distance(0m, 0.3m, 1m, 3m, 5m)(p<.05) 9. Before and after protection on electric fields mount are consideration to 0m, 1m, 3m distance(p<.05), and consideration not to 0.3m, 5m distance(p>.05) 10. After protection fellow the each electrotherapy units. distance, intencity to electromagnetic fields are reduced(p<.05).

  • PDF

A Study on Enhancing Managerial Performance of Business Incubators and Developing Differentiation Strategy (비즈니스 인큐베이터의 경영 성과 향상 및 차별화 전략 수립에 대한 연구)

  • SEO, Dayoon;Bae, SungUk;BAE, SungMin
    • Journal of Korean Society for Quality Management
    • /
    • v.45 no.3
    • /
    • pp.463-481
    • /
    • 2017
  • Purpose: This study provide the matching mechanism between startup and business incubator to enhance managerial performance of business incubator. In addition, we propose the differentiation strategy for business incubator based on the needs of startups. Methods: In order to carry out the research, we surveyed 216 startups who already have invested in venture capitals and angel investors and currently residing in business incubator and 30 venture capitals and angel investors. Based on survey results, we develop a business incubator capability table matching startup with business incubator. Results: Satisfaction and importance of the supporting programs varied depending on the startup experience and startup lifecycle. As a result, we recommended a R&D center for machinery/material, bio/medical and electric/electronics startups and individual office for ICT and knowledge service startups. In addition, we suggested a differentiation strategy to BI in university specialized for machinery/material, privately operated BI for electric/electronic, (local)government, R&D center and individual office for knowledge service respectively. Conclusion: In this study, business incubator capability table is applied to match startup with business incubator and it could be applied to evaluate the current status of business incubator. Furthermore, it will help to establish a future strategic direction for business incubator.

Studies on the characteristics of stone structures by shape reversal, geotechnical and dynamic structural engineerings (석조구조물의 효율적 유지관리를 위한 형상역공학적, 지반공학적 및 구조동역학적 특성연구 - 첨성대를 중심으로 -)

  • Shon, Bo-Woong;Kim, Seong-Beom
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.25-48
    • /
    • 2004
  • Structures show the phehomena of deformation and lowering of function with time-lapse by artificial environments and changes of geotechnical conditions or accumulation of initial deformation elements. This study aims the structural assessment of cultural property, Chum-Sung-Dae, located in Kyeongju city, Korea. It was built about 1,300 years ago, and has undergone deformation and ground-subsidence with time-lapse. Non-destructive evaluation techniques were applied to the Chum-Sung-Dae, to protect it from survey Because of this reason, 3D precise laser scanning surveying system was applied to measure the exact size of Chum-Sung-Dae, displacement and declining angles. Geophysical exploration also was applied to study the subsurface distribution of geotechnical parameters or physical properties. Natural frequencies were measured from real and model of Chum-Sung-Dae to study the dynamic characteristics of vibration and/or earthquake load and stiffness of structures.

  • PDF

Application Techniques of 2D-Resistivity Structure for Estimation of Inferred Fracture Zone in Weathered Slope (풍화사면에서의 추정파쇄대 평가를 위한 2차원 전기비저항 구조도 적용 기법)

  • Kim, Jae-Hong;Park, Chal-Sook;Lee, Hyun-Jae;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.19 no.3
    • /
    • pp.323-330
    • /
    • 2009
  • Electrical resistivity survey is applied for estimation of inferred fault and fractured zone in civil engineering and environment field. While 15 m diameter and 3 lines tunnels are excavated. It is recognized that core stone and fractured zone is existed in the weathered slope of the entrance to a tunnel. To make confirmation geological characteristics, dipole-dipole electric resistivity survey was carried out in weathered slope of the entrance to a tunnel. Core stone distribution and fracture zone characteristics are estimated by reverse analysis and 2D-resistivity structure using FDM.

Three-dimensional Electromagnetic Modeling in Frequency Domain (주파수영역 전자법의 3차원 모델링)

  • Jang, Hannuree;Kim, Hee Joon
    • Geophysics and Geophysical Exploration
    • /
    • v.17 no.3
    • /
    • pp.163-170
    • /
    • 2014
  • Development of a modeling technique for accurately interpreting electromagnetic (EM) data is increasingly required. We introduce finite difference (FD) and finite-element (FE) methods for three-dimensional (3D) frequency-domain EM modeling. In the controlled-source EM methods, formulating the governing equations into a secondary electric field enables us to avoid a singularity problem at the source point. The secondary electric field is discretized using the FD or FE methods for the model region. We represent iterative and direct methods to solve the system of equations resulting from the FD or FE schemes. By applying the static divergence correction in the iterative method, the rate of convergence is dramatically improved, and it is particularly useful to compute a model including surface topography in the FD method. Finally, as an example of an airborne EM survey, we present 3D modeling using the FD method.

Indirect Inspection Signal Diagnosis of Buried Pipe Coating Flaws Using Deep Learning Algorithm (딥러닝 알고리즘을 이용한 매설 배관 피복 결함의 간접 검사 신호 진단에 관한 연구)

  • Sang Jin Cho;Young-Jin Oh;Soo Young Shin
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.19 no.2
    • /
    • pp.93-101
    • /
    • 2023
  • In this study, a deep learning algorithm was used to diagnose electric potential signals obtained through CIPS and DCVG, used indirect inspection methods to confirm the soundness of buried pipes. The deep learning algorithm consisted of CNN(Convolutional Neural Network) model for diagnosing the electric potential signal and Grad CAM(Gradient-weighted Class Activation Mapping) for showing the flaw prediction point. The CNN model for diagnosing electric potential signals classifies input data as normal/abnormal according to the presence or absence of flaw in the buried pipe, and for abnormal data, Grad CAM generates a heat map that visualizes the flaw prediction part of the buried pipe. The CIPS/DCVG signal and piping layout obtained from the 3D finite element model were used as input data for learning the CNN. The trained CNN classified the normal/abnormal data with 93% accuracy, and the Grad-CAM predicted flaws point with an average error of 2m. As a result, it confirmed that the electric potential signal of buried pipe can be diagnosed using a CNN-based deep learning algorithm.