• Title/Summary/Keyword: 3D cases

Search Result 2,013, Processing Time 0.037 seconds

An algorithm to simulate the nonlinear behavior of RC 1D structural members under monotonic or cyclic combined loading

  • Nouban, Fatemeh;Sadeghi, Kabir
    • Structural Engineering and Mechanics
    • /
    • v.66 no.3
    • /
    • pp.305-315
    • /
    • 2018
  • Interaction of lateral loading, combined with axial force needs to be determined with care in reinforced concrete (RC) one-dimensional structural members (1D SMs) such as beam-columns (BCs) and columns. RC 1D SMs under heavy axial loading are known to fail by brittle mode and small lateral displacements. In this paper, a macro element-based algorithm is proposed to analyze the RC 1D SMs under monotonic or cyclic combined loading. The 1D SMs are discretized into macro-elements (MEs) located between the critical sections and the inflection points. The critical sections are discretized into fixed rectangular finite elements (FRFE). The nonlinear behavior of confined and unconfined concretes and steel elements are considered in the proposed algorithm. The proposed algorithm has been validated by the results of experimental tests carried out on full-scale RC structural members. The evolution of ultimate strain at extreme compression fiber of a rectangular RC section for different orientations of lateral loading shows that the ultimate strain decreases with increasing the axial force. In the examined cases, this ultimate strain ranges from 0.0024 to 0.0038. Therefore, the 0.003 value given by ACI-318 code for ultimate strain, is not conservative and valid for the combined load cases with significant values of axial force (i.e. for the axial forces heavier than 70% of the ultimate axial force).

3D-printed Face Shields for Healthcare Professionals Battling COVID-19 Pandemic

  • Kim, Gyeong-Man;Assefa, Dawit;Kang, Joon Wun;Gebreyouhannes, Esayas
    • Journal of Appropriate Technology
    • /
    • v.6 no.2
    • /
    • pp.226-237
    • /
    • 2020
  • As the number of reported COVID-19 cases rises around the world, regions affected by the virus are taking serious measures to contain its spread. Face shields are one of the highest-need personal protective equipment (PPE) during COVID-19 pandemic. Beyond traditional face masks, as known cases of the coronavirus soar, currently there is a significant shortage of face shields around the world. In response, the protective face shields were designed and fabricated with open-source 3D modelling software and 3D printing technology, respectively. Our face shield consisted of two parts only; a reusable 3D printed headband and a visor made of transparent plastic sheet, as barrier. The resulting 3D printed face shields are affordable, lightweight, one-size-fits-most and ready-to-wear with minimal assemblies, and go on easily over glass, goggle and face mask. To ensure being donated to the healthcare professionals without risk infected by any pathogens, the 3D printed face shields were successfully be disinfected with ultraviolet germicidal irradiation (UVGI dosage of 1000 mJ/cm2) and 70% alcohol. For routine disinfection a UVGI chamber was designed and optimized to provide uniform UV-C illumination with an appreciated fluence for complete decontamination. More than 1,000 face shields were produced already and donated to the special hospitals for COVID-19 patients, quarantines, government and medical agencies in Ethiopia as well as in East-African countries. With certainty, our intention goes beyond the hospitals and other first responders, but not limited for all those who have to stay in the service or be in contact with many other people in the time of COVID-19 pandemic.

A Study on the Customization of Shoes Design Characteristics with 3D Printing Technology (3D 프린팅 기술을 적용한 맞춤형 슈즈디자인 특성에 관한 연구)

  • Park, Junhong;Lee, Junsang
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.516-517
    • /
    • 2019
  • 3D printing technology has been receiving attention as a key technology in that it can output 3D printed designs that are either virtual or flat. This study analyzed the general manufacturing process by first compiling the concept of shoes, presented the 3D printed shoe manufacturing process, and studied custom manufacturing techniques by dividing the produced shoe cases by brand (sports brand, designer brand). Through case analysis, 4 design manufacturing techniques of 3D printed shoes were derived. Therefore, this study is expected to provide a basis for more advanced creative ideas in the shoe design area using 3D printing.

  • PDF

Application of 3D Simulation Surgery to Orthognathic Surgery of Hemimandibular Hypoplasia

  • Park, Jin Hoo;Jung, Young-Soo;Kwon, Sun-Mo;Lim, Jae-Seok;Jung, Hwi-Dong
    • Journal of International Society for Simulation Surgery
    • /
    • v.3 no.2
    • /
    • pp.69-73
    • /
    • 2016
  • Traditionally 2D cephalometric analysis has been used for diagnosis and treatment of maxillofacial deformities. However, 2D has some limitations in diagnosis and treatment planning especially facial asymmetry cases. The most weakness of 2D is overlapping and unpredictability. Today 3D treatment tools are used by many maxillofacial surgeons. 3D treatment tools can show ungarbled facial anatomy and do virtual surgery. The aim of this report is to present usefulness of using 3D analysis and virtual orthognathic surgery for severe facial asymmetry patients.

The change of pupil size after viewing three dimensional TV (2안식 입체TV 주시전후의 동공면적의 변화)

  • Cho, Am
    • Journal of the Ergonomics Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.25-32
    • /
    • 1995
  • The physiological change of eyes while viewing 3D TV was investigated. The change of pupil size was used as the measure of evaluation. The results are as follows : (1) The pupil size decreases after viewing 2D and 3D image and the the tendency is more critical with 3D images. (2) The indoor illumination has a significant effect on the pupil size in both 2D and 3D cases. (3) Less chage of pupil size were observed under the indoor illumination. Thus, if we only focus on the visual load on the eye, for viewing 3D image, it will be better to use indoor illumination.

  • PDF

Four Human Cases of Diphyllobothrium nihonkaiense (Eucestoda: Diphyllobothriidae) in China with a Brief Review of Chinese Cases

  • Cai, Yu-Chun;Chen, Shao-Hong;Yamasaki, Hiroshi;Chen, Jia-Xu;Lu, Yan;Zhang, Yong-Nian;Li, Hao;Ai, Lin;Chen, Hai-Ning
    • Parasites, Hosts and Diseases
    • /
    • v.55 no.3
    • /
    • pp.319-325
    • /
    • 2017
  • We described 4 human infection cases of zoonotic fish-tapeworm, Diphyllobothrium nihonkaiense, identified with morphological and molecular characters and briefly reviewed Chinese cases in consideration of it as an emerging parasitic disease in China. The scolex and mature and gravid proglottids of some cases were seen, a rosette-shaped uterus was observed in the middle of the mature and gravid proglottids, and the diphyllobothriid eggs were yellowish-brown in color and displayed a small knob or abopercular protuberance on the opposite end of a lid-like opening. The average size of the eggs was recorded as $62-67{\times}42-45{\mu}m$. The parasitic materials gathered from 4 human cases were morphologically identified as belonging to the genera Diphyllobothrium and Adenocephalus. The phylogenetic analysis based on the nucleotide sequences of cytochrome c oxidase subunit 1 gene of the etiologic agents confirmed that the 4 cases were D. nihonkaiense infection. The finding of 4 additional D. nihonkaiense cases suggests that D. nihonkaiense might be a major causative species of human diphyllobothriasis in China. A combined morphological and molecular analysis is the main method to confirm D. nihonkaiense infection.

Automation measurement of a 3D scanner using a robot simulator (로봇시뮬레이터를 이용한 3 차원 스캐너의 측정 자동화)

  • 유희욱;장평수;장민호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.836-839
    • /
    • 2004
  • Qualitative elevation of products is very important Part. A business racking us brains to find for qualitative elevation of products. Recently, measurement accuracy of a non-contact 3D scanner has been rapidly improving. As a result, the number application cases of non-contact 3D scanners are increasing. A non-contact 3D scanner is capable of measuring a curved surface rapidly and has high resolution. It is more affordable and potable than the CMMs, It is therefore expected to be applied more frequently in more diverse industries. Automating the measuring process using a non-contact 3D scanner and developing a technology, which allows a user to measure easily, will eventually improve the quality of products. As their inspection and analysis processes improve.

  • PDF

THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE BONE ANCHORED FIXED PROSTHESIS ACCORDING TO THE LOAD CONDITION (골유착 고정성 보철물 하에서 하중조건에 따른 삼차원 유한요소법적 분석)

  • Yang, Soon-Ik;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.4
    • /
    • pp.780-806
    • /
    • 1995
  • The purpose of this study was to describe the application of 3D finite element analysis to determine resultant stresses on the bone anchored fixed prosthesis, implants and supporting bone of the mandible according to fixture numbers and load conditions. 4 or 6 fixtures and the bone anchored fixed prosthesis were placed in 3D finite element mandibular arch model which represents an actual mandibular skull. A $45^{\circ}$ diagonal load of 10㎏ was labiolingually applied in the center of the prosthesis(P1). A $45^{\circ}$ diagonal load of 20㎏ was buccolingually applied at the location of the 10mm or 20mm cantilever posterior to the most distal implant(P2 or P3). The vertical distribution loads were applied to the superior surfaces of both the right and the left 20mm cantilevers(P4). In order that the boundary conditions of the structure were located to the mandibular ramus and angle, the distal bone plane was to totally fixed to prevent rigid body motion of the entire model. 3D finite element analysis was perfomed for stress distribution and deflection on implants and supporting bone using commercial software(ABAQUS program. for Sun-SPARC Workstation. The results were as follows : 1. In all conditions of load, the hightest tensile stresses were observed at the metal lates of prostheses. 2. The higher tensile stresses were observed at the diagonal loads rather than the vertical loads 3. 6-implants cases were more stable than 4-implants cases for decreasing bending and torque under diagonal load on the anterior of prosthesis. 4. From a biomechanical perspective, high stress developed at the metal plate of cantilever-to-the most distal implant junctions as a consequence of loads applied to the cantilever extension. 5. Under diagonal load on cantilever extension, the 6-implants cases had a tendency to reduce displacement and to increase the reaction force of supporting point due to increasing the bendign stiffness of the prosthesis than 4-implants cases. 6. Under diagonal load on cantilever extension, the case of 10mm long cantilever was more stable than that of 20mm long cnatilever in respect of stress distribution and displacement. 7. When the ends of 10mm or 20mm long cantilever were loaded, the higher tensile stress was observed at the second most distal implant rather than the first most distal implant. 8. The 6-implants cases were more favorable about prevention of screw loosening under repeated loadings because 6-implants cases had smaller deformation and 4-implants cases had larger deformation.

  • PDF

Comparison of 3D Reconstruction Image and Medical Photograph of Neck Tumors (경부 종물에서 3차원 재건 영상과 적출 조직 사진의 비교)

  • Yoo, Young-Sam
    • Korean Journal of Head & Neck Oncology
    • /
    • v.26 no.2
    • /
    • pp.198-203
    • /
    • 2010
  • Objectives : Getting full information from axial CT images needs experiences and knowledge. Sagittal and coronal images could give more information but we have to draw 3-dimensional images in mind with above informations. With aid of 3D reconstruction softwares, CT data are converted to visible 3D images. We tried to compare medical photographs of 15 surgical specimens from neck tumors with 3D reconstructed images of same patients. Material and Methods : Fifteen patients with neck tumors treated surgically were recruited. Medical photograph of the surgical specimens were collected for comparison. 3D reconstruction of neck CT from same patients with aid of 3D-doctor software gave 3D images of neck masses. Width and height of tumors of each photos and images from the same cases were calculated and compared statistically. Visual similarities were rated between photos and 3D images. Results : No statatistical difference were found in size between medical photos and 3D images. Visual similarity score were higher between 2 groups of images. Conclusion : 3D reconstructed images of neck mass looked alike the real photographs of excised neck mass with similar calculated sizes. It could give us reliable visual information about the mass.

Clinical validation of the 3-dimensional double-echo steady-state with water excitation sequence of MR neurography for preoperative facial and lingual nerve identification

  • Kwon, Dohyun;Lee, Chena;Chae, YeonSu;Kwon, Ik Jae;Kim, Soung Min;Lee, Jong-Ho
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.259-266
    • /
    • 2022
  • Purpose: This study aimed to evaluate the clinical usefulness of magnetic resonance (MR) neurography using the 3-dimensional double-echo steady-state with water excitation (3D-DESS-WE) sequence for the preoperative delineation of the facial and lingual nerves. Materials and Methods: Patients underwent MR neurography for a tumor in the parotid gland area or lingual neuropathy from January 2020 to December 2021 were reviewed. Preoperative MR neurography using the 3D-DESS-WE sequence was evaluated. The visibility of the facial nerve and lingual nerve was scored on a 5-point scale, with poor visibility as 1 point and excellent as 5 points. The facial nerve course relative to the tumor was identified as superficial, deep, or encased. This was compared to the actual nerve course identified during surgery. The operative findings in lingual nerve surgery were also described. Results: Ten patients with parotid tumors and 3 patients with lingual neuropathy were included. Among 10 parotid tumor patients, 8 were diagnosed with benign tumors and 2 with malignant tumors. The median facial nerve visibility score was 4.5 points. The distribution of scores was as follows: 5 points in 5 cases, 4 points in 1 case, 3 points in 2 cases, and 2 points in 2 cases. The lingual nerve continuity score in the affected area was lower than in the unaffected area in all 3 patients. The average visibility score of the lingual nerve was 2.67 on the affected side and 4 on the unaffected side. Conclusion: This study confirmed that the preoperative localization of the facial and lingual nerves using MR neurography with the 3D-DESS-WE sequence was feasible and contributed to surgical planning for the parotid area and lingual nerve.