• Title/Summary/Keyword: 3D body scan measurements

Search Result 47, Processing Time 0.022 seconds

Comparison of Virtual Avatars by Using Automatic and Manual Method

  • Lim, Ho-Sun;Istook, Cynthia L.
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.12
    • /
    • pp.1968-1979
    • /
    • 2010
  • New technology that includes 3D body scanning, digital virtual human, and digital virtual garments has had a significant impact on the current apparel industry. Virtual simulation technology enables the visualization of a 3D virtual garment on a virtual avatar so that consumers can try on garments with their virtual avatars before purchasing. However, the manual virtual avatar provided for online apparel shopping currently has revealed limitations on the different body sizes and shapes of customers. This study analyzes the process of designing the automatic virtual avatar and the manual virtual avatar using OptiTex software; in addition, the study compares the practicality of the automatic virtual avatar with that of the manual virtual avatar. Data was examined by evaluating how much each virtual avatar is similar to the real body and how well it matched the needs of the current apparel industry. In the study, Avatar 1 was automatically created from three-dimensional body scan data and Avatar 2 was manually created from body measurements. The virtual avatar images laid over a real body image and the results were evaluated by comparing the simulated sizes of virtual avatars with those of a real body. Consequently, Avatar 1 was evaluated as more similar to the real body than Avatar 2 in all five body shapes. This study illustrates that an automatic virtual avatar might solve the fit problem that is the most common reason for a high return rate for online shopping. The results show that future virtual simulation technology needs to be improved for the practicality of the virtual avatars.

A Study on the Breast Shape Analysis of Big-breasted Women (볼륨 유방 여성의 흉부체형 분석에 관한 연구)

  • Han, ChoHee;Yi, Kyong-Hwa
    • Journal of Fashion Business
    • /
    • v.22 no.5
    • /
    • pp.32-40
    • /
    • 2018
  • Big breasted women often experience dissatisfaction with ready-made brassieres, that do not account for individual breast types nor provide adequate cup sizes. This study was conducted to provide basic information on common breast shape and measurements of Korean big-breasted women, and to facilitate development of big-breasted women's bras with excellent fit and comfort. The study analyzed direct upper body measurements of 178 women in their 20's whith cup size C or bigger in the 5th, 6th and 7th Size Korea. In addition, 3D body scan data of women with bra size 75 and cup size C were re-collected and their breast types were examined. Average under-bust circumference of big-breasted women was 75 size in brassiere size. The average stature was 159.78 cm and the body weight was 60.33kg, indicating "overweight". Also, it was revealed that common breast types of big-breasted women, were hemispheric and cone types. The study can facilitate better understanding of breast shapes and sizes of standard big-breasted women, and will be useful as reference in selection of subjects in future studies.

A Study on the Comparison of 3D Virtual Clothing and Real Clothing by Neckline Type (네크라인 종류에 따른 3D 가상착의와 실제착의 비교 연구)

  • Nam, Young-Ran;Kim, Dong-Eun
    • Fashion & Textile Research Journal
    • /
    • v.23 no.2
    • /
    • pp.247-260
    • /
    • 2021
  • While it is an important element of clothing construction, research has so far been very limited on the similarities between virtual and real clothing in terms of the type of neckline. The purpose of this study is to verify the similarity, accuracy of virtualization, and actuality of neckline, which all play an important role in individual impressions and image formation, and require considerable modification when fitting real samples. A total of 5 neckline models were selected through the analysis of dress composition textbooks. The selected designs were then planned and manufactured in muslin. The specimen clothes were then tested on a female model in her 20s. 2 kinds of virtual bodies were created in order to compare the real and the virtual dressing. The first virtual body was made through an Artec 3D Eva scan of the model, and the other was made by entering the model's measurements in a CLO 3D program. A visual image of the front, side, and back image of both the real and virtual dressing were subsequently collected. The collected images were then evaluated by 20 professional fashion workers who checked the similarity between the real and the virtual versions. The current study found that the similarity between the actual and virtual wearing of the five neckline designs with reality appeared higher with the virtual wearing image using the 3D-scanned body. The results of this study could provide further information on the selection of appropriate avatars to clothing companies that check the fit of clothing by utilizing 3D virtualized programs.

A Study of In-sole Plantar Pressure Distribution in Functional Tennis Shoes (기능성 전문테니스화의 족저압력분포 분석)

  • Lee, J.S.;Kim, Y.J.;Park, S.B.
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.99-118
    • /
    • 2004
  • The aim of this study is to evaluate tennis shoes's plantar pressure distribution in tennis prayers and to determine the influence of the shoe on various tennis movements. When investigating the biomechanics of movement in tennis, one of the first things to do is to understand the movement patterns of the sport, specifically how these patterns relate to different tennis shoes. Once these patterns are understood, footwear company can design tennis shoes that match the individual needs of tennis players. Plantar pressure measurement is widely employed to study foot function, the mechanical pathogenesis for foot disease and as a diagnostic and outcome measurement tool for many performance. Measurements were taken of plantar pressure distribution across the foot and using F-Scan(Tekscan Inc.) systems respectively. The F-Scan system for dynamic in-shoe foot pressure measurements has enabled us to assess quantitatively the efficacy of different types of footwear in reducing foot pressures. The Tekscan F-Scan system consists of a flexible, 0.18mm thick sole-shape having 1260 pressure sensors, the sensor insole was trimmed to fit the subjects' right, left shoes. For this study 4 university male, high level tennis players were instructed to hit alternated forehand stroke, backhand stroke, forehand volley, backhand volley, smash, service movement in 4 different tennis shoes. 1. When impact in tennis movement, peak pressure distribution of landing foot displayed D>C>B>A, A displayed the best low pressure distribution. A style's tennis shoes will suggest prayer with high impact. If prayer with high impact feeling during pray in tennis wear A style, it will decrease injury, will have performance improvement. 2. When impact in tennis movement, plantar pattern of pressure distribution in landing foot displayed B>A>C>D in stability performance. During tennis, prayer want to stability movement suggest B style tennis shoes when tennis movement impact keep stability of human body. B style tennis shoes give performance improvement 3. When impact in tennis movement, plantar pattern of center of force(C.O.F.)trajectory in landing foot analyzed this : 1) When stroke movement and volley movement in tennis, prayer better to rearfoot movement. 2) when service movement, prayer midfoot strike movement. 3) when smash movement, prayer have forefoot strike movement.

Application of Lower Body Girth Change Analysis Using 3D Body Scanning to Pants Patterns

  • Choi, Sun-Yoon;Ashdown, Susan P.
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.6
    • /
    • pp.955-968
    • /
    • 2010
  • Three-dimensional body data has been used in many industry fields including the apparel industry. This research used data from a study of the changes in lower body girth measurements from a 3D scan study of 25 female subjects aged 18 to 24 in four postures; a standing posture, a $120^{\circ}$ knee bend posture, a one pace stepping posture, and a sitting posture with a $90^{\circ}$ knee bend. We used the information on the difference between standing and seated measurements to adjust ease values for pants patterns an evaluation of the appearance, and the comfort of the pants. Waist girth in the sitting posture increased 8% compared to a standing posture and the hip girth measurement increased 7%. A basic pants pattern (pants A) with 2.4cm ease at the waist and 2.6cm ease at the hip was developed and a pants pattern (pants B) was developed using the rates of lower body girth change with a 5.7cm ease (8% change) at the waist and 7cm ease (7% change) at the hip. The appearance assessment items of pants A in a standing posture were higher than pants B. On the other hand, most appearance assessment items of pants B in a sitting posture were higher than pants A, especially the ease of pants back waistline and the appearance of the whole back. Comfort assessment items of pants B in both standing and sitting postures were higher than the comfort assessment items for pants A, especially the location of pants waistline, the ease of pants at the waistline, and the ease at the abdomen. In order to find the best level of ease for better appearance and comfort in both standing and sitting postures, 20 pants were constructed with ease values at the waist and hip in increments of 1.1cm in the range between the ease values of pants A and pants B. A fit test was conducted to compare the average appearance and comfort ratings that identified the pants with the best ease values at the waist and hip. The highest total mean was achieved in the pants with a waist ease of 4.6cm and hip ease of 4.8cm.

320-Channel Multi-Frequency Trans-Admittance Scanner(TAS) for Anomaly Detection (도전율 및 유전율이 다른 병소의 검출을 위한 320-채널 다주파수 Trans-Admittance Scanner(TAS))

  • Oh, Tong-In;Lee, Min-Hyoung;Kim, Hee-Jin;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.84-94
    • /
    • 2007
  • In order to collect information on local distribution of conductivity and permittivity underneath a scan probe, we developed a multi-frequency trans-admittance scanner (TAS). Applying a sinusoidal voltage with variable frequency on a chosen distal part of a human body, we measure exit currents from 320 grounded electrodes placed on a chosen surface of the subject. The electrodes are packaged inside a small and light scan probe. The system includes one voltage source and 17 digital ammeters. Front-end of each ammeter is a current-to-voltage converter with virtual grounding of a chosen electrode. The rest of the ammeter is a voltmeter performing digital phase-sensitive demodulation. Using resistor loads, we calibrate the system including the scan probe to compensate frequency-dependent variability of current measurements and also inter-channel variability among multiple. We found that SNR of each ammeter is about 85dB and the minimal measurable current is 5nA. Using saline phantoms with objects made from TX-151, we verified the performance of the lesion estimation algorithm. The error rate of the depth estimation was about 19.7%. For the size estimate, the error rate was about 15.3%. The results suggest improvement in lesion estimation algorithm based on multi-frequency trans-admittance data.

Development of a Sizing System of Women's Fitness Wear for the Senior Population in South Korea (한국 노인 여성을 위한 피트니스 압박웨어 치수 개발)

  • Jeon, Eun-Jin;Lee, Won-sup;Park, Jang-Woon;You, Hee-Cheon
    • Fashion & Textile Research Journal
    • /
    • v.20 no.4
    • /
    • pp.464-473
    • /
    • 2018
  • The objective of this study is to develop a sizing system of fitness clothing that can properly accommodate various body sizes of Korean senior women. The sizing system of upper and lower fitness clothing was developed in the present study by selection of key variables, identification of size category candidates, and determination of an optimal sizing system. First, key anthropometric dimensions (stature and bust circumference for upper clothing and stature; waist circumference for lower clothing) were identified by factor analysis on the direct body measurements (n = 272) and 3D whole-body scan data (n = 271) of Korean senior women in Size Korea. Second, sizing system candidates based on the key dimensions of upper and lower clothing were explored using a grid method and an optimization method. Lastly, among the sizing system candidates, optimal sizing systems of upper and lower clothing were selected in terms of accommodation rate. Five size categories (short/small, short/medium, tall/small, tall/medium, and tall/large) were selected as the optimal sizing systems of upper and lower clothing with 89% and 78% of accommodation rate, respectively, for the Korean senior women. The anthropometric characteristics of the representative humans of the optimal size categories would be of use in the design of fitness compressive wear for the better fit and effectiveness of exercise and health of Korean senior women.