• Title/Summary/Keyword: 3D Ultrasonic

Search Result 309, Processing Time 0.036 seconds

DEVELOPMENT OF AN INTELLIGENT ULTRASONIC EVALUATION SYSTEM WITH A MULTI-AXIS PORTABLE SCANNER

  • Sung-Jin Song;Hak-Joon Kim;Won-Suk Sung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.167-176
    • /
    • 1996
  • Flaw classification and sizing are very essential issues in quantitative ultrasonic nondestructive evaluation of various materials and structures including weldments. For performing of these tasks in an automated fashion, we are developing an intelligent ultrasonic evaluation system with a multi-axis portable scanner which can do consistent and efficient acquisition and processing of ultrasonic flaw signals. Here we present our efforts to develop of this intelligent system including design of the portable scanner, acquisition and processing of ultrasonic flaw signals, display of pseudo 3-D image of flaws, and classification and sizing of flaws in weldments.

  • PDF

Piezoelectric Properties of PMN-PNN-PZT Ceramics and the Simulation of Ultrasonic Cleaner

  • Sujin Kang;Ju Hyun Yoo;Sun A Whang;Jae Gyu Lee;Jong Hyeon Lee;Ji Hoon Lee;Dae Yeol Hwang;Sua Kim;Seong Min Lee;Han Byeol Kim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.2
    • /
    • pp.191-196
    • /
    • 2023
  • In this paper, for the application of ultrasonic cleaners for cleaning dentures and transparent braces, Pb(Mn1/3Nb2/3)O3-Pb(Ni1/3 Nb2/3)O3-Pb(Zr,Ti)O3 [PMN-PNN-PZT] system ceramics were manufactured and their dielectric and piezoelectric properties were investigated. Overall the best properties suitable for the device applications such as ultrasonic cleaner were obtained from the ceramics sintered at 920℃: bulk density of 7.8 g/cm3, the dielectric constant (εr) of 1,689, piezoelectric charge constant (d33) of 433 pC/N, planar electromechanical coupling factor (kp) of 0.64, mechanical quality factor (Qm) of 835, S11E of 13.37 (10-12 N/m2), and Curie temperature of 315℃ By using the physical properties of this composition, the ultrasonic cleaner was designed and simulated using the commercial ATILA software. For the three-layered ceramics with the dimension of 25 mm × 25 mm × 2.5mm, an excellent displacement of 8.998 10-3 m) and the sound pressure of 147.68 dB were recorded.

Ultrasonic Estimation and FE Analysis of Elastic Modulus of Kelvin Foam

  • Kim, Nohyu;Yang, Seungyong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.1
    • /
    • pp.9-17
    • /
    • 2016
  • The elastic modulus of a 3D-printed Kelvin foam plate is investigated by measuring the acoustic wave velocity of 1 MHz ultrasound. An isotropic tetrakaidecahedron foam with 3 mm unit cell is designed and printed layer upon layer to fabricate a Kelvin foam plate of 14 mm thickness with a 3D CAD/printer using ABS plastic. The Kelvin foam plate is completely filled with paraffin wax for impedance matching, so that the acoustic wave may propagate through the porous foam plate. The acoustic wave velocity of the foam plate is measured using the time-of-flight (TOF) method and is used to calculate the elastic modulus of the Kelvin foam plate based on acousto-elasticity. Finite element method (FEM) and micromechanics is applied to the Kelvin foam plate to calculate the theoretical elastic modulus using a non-isotropic tetrakaidecahedron model. The predicted elastic modulus of the Kelvin foam plate from FEM and micromechanics model is similar, which is only 3-4% of the bulk material. The experimental value of the elastic modulus from the ultrasonic method is approximately twice as that of the numerical and theoretical methods because of the flexural deformation of the cell edges neglected in the ultrasonic method.

A Study on the Vibration Characteristics in Ultrasonic Levitation System according to the Circular Plate (원형 플레이트 형태에 따른 초음파 부상 장치의 진동특성에 관한 연구)

  • Jeong SangHwa;Choi SukBong;Cha KyoungRae;Kim HyunUk;Kim GwangHo;Park JuneHo
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.364-369
    • /
    • 2005
  • In the semiconductor and optical industry the non-contact transportation is required for reducing the damages. The ultrasonic levitation is the solution of the problem. In this paper, the ultrasonic levitation system and 3 disk-type stator for levitation various object are proposed. The vibration modes of disks are analyzed with FEM and designed with the analysis results. The 3D vibration profiles of the disks are measured by Laser scanning vibrometer for verifying the vibration characteristics of the system. The amplitudes of the disks and the levitation heights of object are measured for evaluating the performance.

  • PDF

Microstructure and Piezoelectric Properties of PMW-PNN-PZT Ceramics with Bismuth Substitution (PMW-PNN-PZT 세라믹스의 Bismuth 치환에 따른 미세구조 및 압전 특성)

  • Kim, Yong-Jin;Yoo, Ju-Hyun;Shin, Dong-Chan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.6
    • /
    • pp.332-336
    • /
    • 2016
  • In this study, in order to develop the composition ceramics for ultrasonic sensor with high $d_{33}*g_{33}$, $Pb_{1-3x/2}Bix(Mg_{1/2}W_{1/2})_{0.03}(Ni_{1/3}Nb_{2/3})_{0.09}(Zr_{0.5}Ti_{0.5})_{0.88}O_3$(PMW-PNN-PZT) system ceramics were prepared using CuO as sintering aids. And then, their microstructure, piezoelectric and dielectric characteristics were systemetically investigated with bismuth substitution. The PMW-PNN-PZT ceramic specimens could be sintered at sintering temperature of $940^{\circ}C$ by adding sintering aids. At x=0.015 specimen, the density, electromechanical coupling factor($k_p$), dielectric constant, piezoelectric constant($d_{33}$) and piezoelectric figure of merit($d_{33}*g_{33}$) indicated the optimal properties of $7.90g/cm^3$, 0.67, 2,511, 628 pC/N, and $17.7pm^2/N$, respectively, for duplex ultrasonic sensor application.

A study on the debelopment of the Ultrasonic imaging system for tissue characterization (조직의 정량화를 위한 초음파 영상시스템의 개발에 관한 연구)

  • Choe, Jong-Ho;Choe, Jong-Su
    • The Journal of the Acoustical Society of Korea
    • /
    • v.6 no.3
    • /
    • pp.31-42
    • /
    • 1987
  • An ultrasonic pulse-echo diagnostic system for tissue characterization with the estimation of attenuation coefficients is developed and its performance has been examined by system implementation. The system divided into the ultrasonic generator, A/D converter, data communication, computer for signal processing. The methods for estimating the spatial distribution of acoustic attenuation coefficients using the moment analysis are proposed. The experimental results indicate the potential of the methods for tissue characterization.

  • PDF

An Analysis of Vibration Characteristics in Ultrasonic Object Levitation Transport System (초음파를 이용한 물체 부상 이송시스템의 진동 특성 해석)

  • Jeong S.H.;Kim H.U.;Choi S.B.;Kim G.H.;Park J.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.415-418
    • /
    • 2005
  • In the semiconductor and optical industry, a new transport system which can replace the conventional transport systems is required. The transport systems are driven by the magnetic field and conveyer belts. The magnetic field may damage semiconductor and the contact force may scratch the optical lens. The ultrasonic wave driven system can solve these problems. In this semiconductor and optical industry, the non-contact system is required fur reducing the damages. The ultrasonic transportation is the solution of the problem. In this paper, the ultrasonic levitation system fur levitating object are proposed. The 3D vibration profiles of the beam are measured by Laser scanning Vibrometer fur verifying the vibration characteristics of the system and the amplitudes of the beam and the levitation heights of object are measured for evaluating the performance.

  • PDF

Flexural Beam Design of Ultrasonic Object Levitation Slide System (초음파 물체부상 이송시스템의 Flexural Beam 설계)

  • Jeong, Sang-Hwa;Kim, Hyun-Uk;Choi, Suk-Bong;Kim, Kwang-Ho;Park, Jun-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.959-962
    • /
    • 2005
  • In the semiconductor and optical industry. a new transport system which can replace the conventional transport system is required. The Transport systems are driven by the magnetic field and conveyer belts. The magnetic field may damage semiconductor and the contact force may scratch the optical lens. The ultrasonic wave driven system can solve these problems. In this semiconductor and optical industry, the non-contact system is required for reducing the damages. The ultrasonic transportation is the solution of the problem. In this paper, the ultrasonic levitation system for levitation object are proposed. The 3D vibration profiles of the beam are measured by Laser Scanning Vibrometer for verifying the vibration characteristics of the system and the amplitudes of the beam and the levitation heights of object are measured fore evaluating the performance.

  • PDF

Robot localization and calibration using Ultrasonic and Ratio Frequency (초음파 및 무선 통신 파를 이용한 자기 위치와 비컨 위치 인식 시스템)

  • Yoon J.Y.;Jung K.S.;Shin D.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1040-1044
    • /
    • 2005
  • This paper presents a method for the robot localization and calibration using the ultrasonic and the radio frequency. The distance between the receiver and a beacon can be computed by using the difference between times of flight. The presented method uses the gradient of the maximum amplitude of the ultrasonic in order to measure the time of flight precisely. The measured three distances between the receiver and the beacon are used to compute the robot position by the direct inverse method and the iterated least square approximation method. This paper is defined the calibration as the problem to find the location of 3 beacons and 3 robots, and presents 3 methods for it and found the 2B2R method as the best among them.

  • PDF

A Study on Fabrication and Characteristics of PZT Probe for Nondestructive Test (비파괴 검사를 위한 PZT 탐촉자의 제작 및 특성에 관한 연구)

  • 김철수;정규원;송준태
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.8
    • /
    • pp.613-619
    • /
    • 1998
  • Ultrasonic probes of 400kHz, 1MHz were fabricated using PZT-5Z plates. Epoxy was used for backing layer materials onthe plates. Nondestructive Test was carried using these probes. Pulse lobe width of impulse response was reduced 15.4% compare 1MHz with 400kHz and 96.6% compare 3MHz with 400kHz. The attenuation in aluminum was 2.05[dB/m] at 400kHz, 4/91[dB/m] at 1MHz, 7.35[dB/m] at 3HMz. Hole detection error of the first hole was 22.4% at 1HMz, 9.% at 3HMz, The second hole 11.6% at 1HMz, 4.7% at 3HMz. In the result of experiment of the hole detection error and resolution, 3HMz probe was the best among them.

  • PDF