• Title/Summary/Keyword: 3D Sensitivity Curve

Search Result 56, Processing Time 0.027 seconds

3D Pose Estimation of a Circular Feature With a Coplanar Point (공면 점을 포함한 원형 특징의 3차원 자세 및 위치 추정)

  • Kim, Heon-Hui;Park, Kwang-Hyun;Ha, Yun-Su
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.5
    • /
    • pp.13-24
    • /
    • 2011
  • This paper deals with a 3D-pose (orientation and position) estimation problem of a circular object in 3D-space. Circular features can be found with many objects in real world, and provide crucial cues in vision-based object recognition and location. In general, as a circular feature in 3D space is perspectively projected when imaged by a camera, it is difficult to recover fully three-dimensional orientation and position parameters from the projected curve information. This paper therefore proposes a 3D pose estimation method of a circular feature using a coplanar point. We first interpret a circular feature with a coplanar point in both the projective space and 3D space. A procedure for estimating 3D orientation/position parameters is then described. The proposed method is verified by a numerical example, and evaluated by a series of experiments for analyzing accuracy and sensitivity.

Clinical manifestation of Campylobacter enteritis in children

  • Bae, Joon Yeol;Lee, Dong Hyuk;Ko, Kyung Ok;Lim, Jae Woo;Cheon, Eun Jeong;Song, Young Hwa;Yoon, Jung Min
    • Clinical and Experimental Pediatrics
    • /
    • v.61 no.3
    • /
    • pp.84-89
    • /
    • 2018
  • Purpose: Timely antibiotic therapy in selected cases of diarrhea associated with bacterial infections can reduce the duration and severity of illness and prevent complications. The availability of a predictive index before identification of causative bacteria would aid in the choice of a therapeutic agent. Methods: The study included patients admitted to the pediatrics unit at Konyang University Hospital for acute inflammatory diarrhea from August 1, 2015 to July 31, 2016 who underwent multiplex polymerase chain reaction testing. Of 248 patients, 83 had positive results. The clinical symptoms and blood test results were examined in 61 patients with Campylobacter spp. (25 patients), Salmonella spp. (18 patients), and Clostridium perfringens (18 patients) infections. The mean age of the 61 patients (male:femal=31:30) was $84.0{\pm}54.8months$, and the mean hospital stay was $4.6{\pm}1.7days$. Results: There were no statistical differences in sex, age, clinical symptoms, or signs. Patients with Campylobacter infection were significantly older (P=0.00). C-reactive protein (CRP) levels in patients with Campylobacter infection were higher than those in the other 2 groups, at $9.6{\pm}6.1mg/dL$. The results of receiver-operating characteristic curve analysis showed that the cutoff age was ${\geq}103.5months$ (sensitivity, 72%; specificity, 86%) and the CRP cutoff level was ${\geq}4.55mg/dL$ (sensitivity, 80%; specificity, 69%). Conclusion: Age (${\geq}103.5months$) and higher CRP level (${\geq}4.55mg/dL$) were good predictors of Campylobacter enterocolitis. If neither criterion was met, Campylobacter enterocolitis was unlikely (negative predictive value 97.2%). When both criteria were met, Campylobacter enterocolitis was highly likely.

Comparison of fluorescence loss measurements among various generations of QLF devices (세대별 QLF 기기의 평활면 비와동형 법랑질 우식 병소 탐지에 관한 진단정확도 비교)

  • Park, Seok-Woo;Lee, Hyung-Suk;Kim, Sang-Kyeom;Lee, Eun-Song;de Jong, Elbert de Josselin;Kim, Baek-Il
    • The Journal of the Korean dental association
    • /
    • v.56 no.1
    • /
    • pp.8-16
    • /
    • 2018
  • Purpose: The aim of in vitro study was to compare the diagnostic accuracy to detect non-cavitated enamel caries on smooth surface by using four kinds of the QLF devices. Materials and Methods: A total of 52 human permanent premolars and molars were used. Fluorescence images were captured by the QLF devices (Inspektor Pro, QLF-D, Qraycam, and Qraypen). Fluorescence loss of the QLF was calculated. The severity of lesions was categorized into the following 3 scores using polarized light microscopy: normal (S), enamel demineralization to outer half of enamel (D1), and inner half of the enamel up to the dentin-enamel junction (D2). The Kruskal-Wallis test was used to compare the fluorescence loss among the QLF devices. Spearman rank correlation coefficient between histological scores and fluorescence loss of the devices was calculated. The sensitivity, specificity, and area under the receiver operating curve (AUROC) were calculated to compare their diagnostic accuracies. Results: The correlation coefficients between histological scores and the fluorescence loss of the devices showed 0.77 to 0.81 (P < 0.001). All histological scores, the fluorescence loss among the devices showed no statistical difference. Among the devices, sensitivity, specificity, and AUC values of the fluorescence loss showed 0.84 to 0.94, 0.76 to 0.90, and 0.90 to 0.92, respectively. Conclusions: All QLF devices had no difference with excellent diagnostic accuracies to detect non-cavitated enamel caries on smooth surface.

  • PDF

Reliability Growth Planning for a Military System Using PM2-Continuous Model (예측방법론 기반 연속형 계획 모델을 적용한 무기체계의 신뢰도 성장 계획)

  • Seo, Yangwoo;Park, Eunshim;Kim, Youngkuk;Lee, Kwanyoung;Kim, Myungsoo
    • Journal of Applied Reliability
    • /
    • v.18 no.3
    • /
    • pp.201-207
    • /
    • 2018
  • Purpose: To develop the reliability growth planning for a subsystem of guided weapon system using PM2-Continuous model. Methods: The target MTBF of the subsystem is set by allocating the system target MTBF to the lower level, where ARINC method is applied. Other model parameters such as initial MTBF, management strategy ratio and average fix effectiveness factor are chosen from historical growth parameter estimates. Given the values of model parameters, the reliability growth planning curve using PM2-Continuous model is constructed and the sensitivity analyses are performed for the changes of model parameters. Results: We have developed the reliability growth plan for a subsystem of guided weapon system using PM2-Continuous model. It was found that the smaller the ratio of initial MTBF to target MTBF, the smaller the management strategy ratio, the smaller the average fix effectiveness factor, and the shorter the development test period, the higher reliability growth is required. Conclusion: The result of this study will be used as a basis for establishing the reliability growth plan, the test period setting and the budget appropriation for the similar system entering the system development stage in the future.

Usefulness of $^{18}F$-Fluoride PET/CT in Bone Metastasis of Prostate Cancer (전립선암 환자의 뼈 전이에 대한 $^{18}F$-Fluoride PET/CT의 유용성)

  • Park, Min-Soo;Kim, Jung-Yul;Park, Hoon-Hee;Kang, Chun-Goo;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.24-30
    • /
    • 2009
  • Purpose: Today, Prostate cancer has been gradually increasing, according to the change of internal incidence rate of cancer. Generally, prostate cancer has lead to dead over 90%, in case of metastasis of lymph node and bone. So, innovative development of new radiopharmaceutical and imaging modality is progressed for detection of that metastasis, in nuclear medicine, now. Therefore, this study shows the usefulness of $^{18}F$-Fluoride PET/CT improved diagnosability on bone metastasis of prostate cancer. Materials and Methods: In this study, 33 male patients with prostate cancer were examined (The mean age: $67.8{\pm}10.2$ years old). Every patient was done each whole body bone scan (WBBS) and $^{18}F$-Fluoride positron emission tomography/computed tomography ($^{18}F$-Fluoride PET/CT). And then, using Receiver Operating Characteristic Curve (ROC curve), each sensitivity and specificity of two modalities was measured and compared with. Results: In 22 patients (66.6%) of all, bone metastasis was detected. And, in WBBS, sensitivity was 63.6%, specificity, 81.8%; in $^{18}F$-Fluoride PET/CT, sensitivity was 100% and specificity was 90.9%. As a result of ROC curve, AUROC (The Area under an ROC) of WBBS was 0.778, and that of $^{18}F$-Fluoride PET/CT, 0.942. Conclusions: $^{18}F$-Fluoride PET/CT was higher both sensitivity and specificity than WBBS, and it was valuable to detect bone metastasis of prostate cancer more definitely, with 3D imaging realization. Also, in $^{18}F$-Fluoride PET/CT, physiological images were acquired in more short time than WBBS, so, it was possible to reduce patient's waiting time and complaint. Therefore, it is considered that $^{18}F$-Fluoride PET/CT is able to improve diagnosability by offering more accurate images, as cuts in a share of high cost.

  • PDF

Design of Robust Convolution Input Shaper for the Variation of Frequency and Damping Ratio (주파수와 감쇠비 변화에 강인한 Convolution 입력성형기 설계)

  • Park, Un-Hwan;Lee, Jae-Won;Im, Byeong-Deok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.1
    • /
    • pp.67-73
    • /
    • 2002
  • The flexibility of long reach manipulators presents a difficult control problem when accurate end-point position is required. Input shaping by convolving system commands with impulse sequences has been shown to be an effective method of reducing residual vibrations in flexible systems. However, existing shapers have been considered robustness fur only frequency uncertainty. However, this paper presents new multi-hump convolution(CV) input shaper that could accommodate with the simultaneous variation of natural frequency and damping ratio. Comparisons with previously proposed input shapers are presented to illustrate the qualities of the new input shaper. These new shapers will be shown to have better robustness fur the variation of frequency and damping ratio.

Design of Robust Convolution Input Shaper for Variation of Parameter (파라메터 변화에 강인한 Convolution 입력성형기 설계)

  • Park, Un-Hwan;Lee, Jae-Won;Lim, Byoung-Duk
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.127-133
    • /
    • 2001
  • The flexibility of long reach manipulators presents a difficult control problem when accurate end-point position is required. Input shaping by convolving system commands with impulse sequences has been shown to be an effective method of reducing residual vibrations in flexible systems. However, existing shapers has been considered robustness for only frequency uncertainty. However, this paper presents new multi-hump convolution(CV) input shaper that could accommodate with the simultaneous variation of natural frequency and damping ratio. Comparisons with previously proposed input shapers are presented to illustrate the qualities of the new input shaper. These new shapers will be shown to have better robustness for the variation of frequency and damping ratio.

  • PDF

Determination of Taurine in Preparations by Amino Acid Autoanalyzer (아미노산 분석기에 의한 제제중 Taurine의 분리 정량에 관한 연구)

  • 박만기;한달수
    • YAKHAK HOEJI
    • /
    • v.28 no.1
    • /
    • pp.21-23
    • /
    • 1984
  • High performance amino acid analyzing method has been developed for the routine analysis of taurine in preparations. Ion-exchange resin #2619 Hitachi Custom Ion-Exchange Resin, $2.6(I.D.){\times}150$(length)mm was used as column, buffer I, pH 3.3 as mobile phase. The retention time of taurine was 7 minutes. Calibration curve by peak height for standard taurine was linear from 2.5ppm to 25ppm. The reproducibility showed relative standard deviation $\pm$1.9% when analyzed 10 times for standard solution. The samples could be continuously analyzed without regenerating the resin between samples. Five samples were applied to column every 12 min. and then the resin was regenerated for 30 min. during one analyzing cycle time, 90 min. The automatic amino acid analyzer has made it possible to assay multiple samples in a relatively short period of time using the analytical magnetic program card. The high sensitivity and specificity of the analytical column of the automatic amino acid analyzer permits the routine analysis of taurine in preparations.

  • PDF

Diagnostic Performance of Combined Single Photon Emission Computed Tomographic Scintimammography and Ultrasonography Based on Computer-Aided Diagnosis for Breast Cancer (유방 SPECT 및 초음파 컴퓨터진단시스템 결합의 유방암 진단성능)

  • Hwang, Kyung-Hoon;Lee, Jun-Gu;Kim, Jong-Hyo;Lee, Hyung-Ji;Om, Kyong-Sik;Lee, Byeong-Il;Choi, Duck-Joo;Choe, Won-Sick
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.201-208
    • /
    • 2007
  • Purpose: We investigated whether the diagnostic performance of SPECT scintimammography (SMM) can be improved by adding computer-aided diagnosis (CAD) of ultrasonography (US). Materials and methods: We reviewed breast SPECT SMM images and corresponding US images from 40 patients with breast masses (21 malignant and 19 benign tumors). The quantitative data of SPECT SMM were obtained as the uptake ratio of lesion to contralateral normal breast. The morphologic features of the breast lesions on US were extracted and quantitated using the automated CAD software program. The diagnostic performance of SPECT SMM and CAD of US alone was determined using receiver operating characteristic (ROC) curve analysis. The best discriminating parameter (D-value) combining SPECT SMM and the CAD of US was created. The sensitivity, specificity and accuracy of combined two diagnostic modalities were compared to those of a single one. Results: Both SPECT SMM and CAD of US showed a relatively good diagnostic performance (area under curve = 0.846 and 0.831, respectively). Combining the results of SPECT SMM and CAD of US resulted in improved diagnostic performance (area under curve =0.860), but there was no statistical differerence in sensitivity, specificity and accuracy between the combined method and a single modality. Conclusion: It seems that combining the results of SPECT SMM and CAD of breast US do not significantly improve the diagnostic performance for diagnosis of breast cancer, compared with that of SPECT SMM alone. However, SPECT SMM and CAD of US may complement each other in differential diagnosis of breast cancer.

Analysis on Dynamic Ductile Fracture of Transportation Pipeline for Carbon Dioxide Capture and Storage System (CO2 배관의 연속연성파괴 분석)

  • Jeong, Hyo-Tae;Choe, Byung-Hak;Kim, Woo-Sik;Baek, Jong-Hyeon
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.13-19
    • /
    • 2014
  • Dynamic ductile fracture (DDF) has been studied in the transportation pipeline for the carbon dioxide capture and storage(CCS) system. DDF behavior of CCS transportation pipeline has been analyzed using Battelle Two Curve Method (BTCM) and compared with the DDF behavior of natural gas pipeline. The operating safety criteria against the DDF has been investigated based on the sensitivity analyses of the pipe thickness and the operating temperature for the $CO_2$ pipeline. The DDF criteria can be applied to confirm the operating safety of the $CO_2$ pipeline. If the commercial natural gas pipeline were used at room temperature as a $CO_2$ pipeline, the thickness of pipe should be at least 7mm and the pressure should be less than 54bar for the $CO_2$ pipeline system.