• 제목/요약/키워드: 3D Resistivity inversion

검색결과 61건 처리시간 0.023초

소형루프 전자탐사법을 이용한 연약지반 조사 (Soft Ground Investigations Using Small Loop EM)

  • 김기주;조인기;임진택;경규하;김봉찬
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 공동학술대회 논문집
    • /
    • pp.245-250
    • /
    • 2007
  • The small loop EM method is a fast and convenient geophysical tool which can give shallow subsurface resistivity distribution. It can be a useful alternative of resistivity method in conductive environment. We applied the multi-frequency small loop EM method for the investigation of a soft ground landfill site which was constructed on a tideland since the resistivity of the survey area is extremely low. 3D resistivity distribution was obtained by merging 1D inversion results and shallow subsurface structure can be interpreted. By comparing the result with the drilling log and measured soil resistivity sampled at 16 drill holes, we can get lot of information such as groundwater level, thickness of landfill, salinity distribution, depth to the basement and etc.

  • PDF

폐광지역에서의 3차원 이방성 전기비저항 토모그래피 영상화 (Three-dimensional anisotropic inversion of resistivity tomography data in an abandoned mine area)

  • 이명종;김정호;손정술
    • 지구물리와물리탐사
    • /
    • 제14권1호
    • /
    • pp.7-17
    • /
    • 2011
  • 본 연구에서는 이방성을 포함하는 3차원 전기비저항 토모그래피 프로그램을 개발하였다. 이론 모델링에는 유한요소법을 이용하였고 역산에 ACB 법을 채용하여 평활화 제한 최소자승 역산의 분해능 향상을 기하였다. 수치모형 실험을 통하여 지하구조가 강한 전기적 이방성을 보이는 경우 이방성을 고려한 역산이 필수적임과 이방성이 지하구조의 해석에서 추가적인 정보로 활용 가능함을 보였다. 또한 과거 채굴 터널 상부에 고층 아파트가 건설된 폐광현장에서 획득한 3차원 토모그래피 탐사자료에 개발된 알고리듬을 적용하여 과거 채광활동과 관련된 건축물의 안전성을 평가하고자 하였다. 탐사자료에서 강한 전기적 이방성이 관찰되었고 이는 조사지역의 지질적 특성에 기인하는 것으로 확인되었다. 조사지역의 이방성을 고려하기 위하여 3차원 이방성 전기비저항 토모그래피 영상화를 수행하였으며 이로부터 지질구조에 부합하는 지하 3차원 전기비저항 영상을 획득할 수 있었다. 획득한 전기비저항 영상은 암반공학에서의 지반안정성 분석을 위한 지질구조 모형을 도출하는데 사용되었으며, 이로부터 조사대상인 아파트가 안전성에 문제가 없음을 밝힐 수 있었다.

제체형태와 수위에 따른 전기비저항 반응 연구 (Electrical Resistivity Response Due to the Variation of Embankment Shape and Reservoir Level)

  • 오석훈
    • 지구물리와물리탐사
    • /
    • 제11권3호
    • /
    • pp.214-220
    • /
    • 2008
  • 점토질의 중심코어부에 차수 역할을 의존하는 형식의 제체에 대한 안정성 검토에 자주 적용되는 B차원 전기비저항 탐사자료의 해석 시, 제체의 심벽 구조와 수위에 따른 왜곡 양상을 모델링을 통해 검증하였다. 3차원 구조인 제체의 해석을 주로 2차원으로 수행하는 과정에서 다양한 왜곡효과가 나타났다. 제체의 재료가 수평적으로 균질한 상태에서 수위와 연관지어 분석한 결과, 양안부보다는 제체 중앙부가 비저항 단면에서 수위선을 비교적 정확히 나타내며, 양안에 존재하는 지반 등 3차원 효과로 인해 양안부로 다가가면 수위선이 깊어지는 반응을 보였다. 또한 제체의 가장 외부구조인 채움재부의 경사가 일정할 때, 코어부의 경사가 급할수록 실제 수위와 비슷한 효과를 보였다. 코어부의 경사가 비슷할 때는, 외부 채움재부의 경사가 완만할수록 실제 수위와 비슷한 효과를 보였으며, 양안에서의 3차원 효과도 덜 나타났다. 채움재부의 경사가 급하면 2차원 역산 결과, 실제수위보다 더 깊은 위치에서 수위와 관련된 저비저항대를 지시하였으며, 양안에서의 3차원 효과가 크게 나타났다.

효율적인 3차원 MT 역산을 위한 다양한 감도의 이용 (An Efficient 3D Inversion of MT Data Using Approximate Sensitivities)

  • 한누리;남명진;김희준;이태종;송윤호;서정희
    • 지구물리와물리탐사
    • /
    • 제10권4호
    • /
    • pp.259-267
    • /
    • 2007
  • 정적효과가 포함된 MT 자료를 효율적으로 역산하기 위해 새로운 근사 감도(sensitivity)를 제시하였다. 근사 감도를 이용하여 감도 행렬을 구하는데 필요한 막대한 계산 시간을 합리적인 수준으로 줄이면서 정확한 감도를 이용한 경우와 비슷한 수준의 역산 결과를 얻을 수 있었다. 이 연구에서 제시한 근사 감도 외에 초기 균질 모형에 대한 감도, Broyden 법을 이용하여 업데이트한 감도, 정확한 해에 의존한 감도 등을 여러 가지 조합으로 3차원 역산을 수행할 수 있는 효율적인 방법에 대해 연구하였다. 인공합성자료 및 포항 지역에서 획득한 현장 자료에 대하여 3차원 역산한 결과, 네가지 감도의 조합으로 성공적인 역산이 가능함을 확인하였다. 이로부터 다양한 감도를 적용하여 역산을 수행하는 것이 보다 효율적이고 합리적인 역산 결과를 얻는데 도움이 됨을 알 수 있었다.

국내 맥상광체조사를 위한 3차원 쌍극자-쌍극자 전기비저항 탐사의 적용성 분석 (Feasibility of 3D Dipole-Dipole Electrical Resistivity Method to a Vein-Type Ore Deposit)

  • 민동주;정현기;이효선;박삼규;이호용
    • 지구물리와물리탐사
    • /
    • 제12권3호
    • /
    • pp.268-277
    • /
    • 2009
  • 최근들어 국내 광산탐사가 다시 활성화되면서 물리탐사를 이용한 광산탐사 연구가 늘고 있으며, 물리탐사는 금속광상 뿐만 아니라 비금속광상 탐사에도 활용되어 왔다. 금속광상탐사의 경우 주변에 비해 전기전도도가 높다는 특성에 기초하여 전기비저항 탐사가 많이 이용되며, 대부분 2차원 탐사가 수행된다. 그러나 실제 광맥구조는 주향 방향으로 물성차가 없는 2차원 구조가 아니라 광맥의 폭이 변하거나 광맥의 폭이 좁아지다가 사라지는 3차원 구조이다. 이 연구에서는 이러한 3차원 구조의 효과가 2차원 탐사자료에서 어떻게 나타나는지 조사하였다. 또한 측선이 주향에 수직하지 않은 경우 측선의 방향이 자료해석에 미치는 영향도 함께 살펴보았다. 광맥의 폭이 변하는 모형에 적용해 본 결과 실제 광체가 지표 가까이에 존재하지만 보다 큰 규모의 저비저항대가 심부에 나타났으며, 광체가 존재하다가 사라지는 경우 측선이 광체로부터 떨어져 있음에도 불구하고 마치 직하부에 저비저항대가 존재하는 것처럼 영상화되었다. 이는 모두 3차원 효과에 의한 현상으로 광체가 전혀 존재하지 않는 곳을 시추부지로 선정하도록 유도할 수 있다. 측선이 주향방향과 수직하지 않고 일정한 각을 이루는 경우 측선이 주향에 수직한 경우에 비해서 이상대가 약간 더 넓고 얕게 나타남을 알 수 있었으며, 측선이 주향과 이루는 각이 $45^{\circ}$ 보다 작을 경우 하부 구조가 매우 왜곡되어 나타남을 알 수 있다. 이러한 결과들을 종합해 볼 때, 실제 광상탐사에 전기비저항 탐사를 수행할 경우 2차원 탐사보다는 3차원 탐사를 수행하는 것이 바람직할 것으로 판단된다.

방조제 누수지점 탐지를 위한 SP및 단극배열 전기비저항탐사의 적용 (Application of SP and Pole-pole Array Electrical Resistivity Surveys to the Seawater Leakage Problem of the Embankment)

  • 송성호;이규상;김진호;권병두
    • 자원환경지질
    • /
    • 제33권5호
    • /
    • pp.417-424
    • /
    • 2000
  • We applied SP monitoring and resistivity surveys using the pole-pole electrode array to seawater leakage problems in the Youngsan estuary dam and the Eoeun embankment to estimate and detect the zone of seawater leakage. The embankment is generally affected by tidal variation and has low resistivity characteristics due to the high saturation of seawater. For this reason, SP monitoring and the pole-pole array resistivity surveys, which are relatively more effective to the conductive media, were carried out to delineate the leakage zones of sea water through the embankment. We checked out electrical conductivity (EC) and temperature variations along the inner part of Youngsan estuary dam to detect the zone of seawater leakage and found that the measured EC value agreed to that of seawater in the leakage zone and the temperature was lower than that of the vicinity of leakage zone. SP monitoring results were coincided with tidal variations at each embankment. At the leakage zones in the Youngsan estuary dam and the Eoeun embankment, SP anomalies are in the range of -60~-85 mV and -20~-50 mV, respectively, and true resistivity values obtained by 2-D inversion are 3~15 ohm-m and below 0.3 ohm-m, respectively. Both SP monitoring and the pole-pole array resistivity method are found to be quite effective for investigation of seawater leakage zones in the embankment.

  • PDF

Archaeological Investigations in Urban Areas through Combined Application of Surface ERT and GPR Techniques

  • Papadopoulos, Nikos;Yi, Myeong-Jong;Sarris, Apostolos;Kim, Jung-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2008년도 공동학술대회
    • /
    • pp.113-118
    • /
    • 2008
  • Among the geophysical methods, Ground Penetrating Radar (GPR) and Electrical Resistivity Tomography (ERT) comprise the most promising techniques in resolving buried archaeological structures in urban territories. In this work, two case studies which involve an integrated geophysical survey employing the surface three dimensional (3D) ERT and GPR techniques, in order to archaeologically characterize the investigated areas, are presented. Totally more than 4000 square meters were investigated from the test field sites, which are located at the centre of two of the most populated cities of the island of Crete, in Greece. The ERT and the GPR data were collected along dense and parallel profiles. The subsurface resistivity structure was reconstructed by processing the apparent resistivity data with a 3D inversion algorithm. The GPR sections were processed with a systematic way applying specific filters to the data in order to enhance their information context. Finally, horizontal depth slices representing the 3D variation of the physical properties were created and the geophysical anomalies were interpreted in terms of possible archaeological structures. The subsequent excavations in one of the sites verified the geophysical results, enhancing the applicability of ERT and GPR techniques in the archaeological exploration of urban territories.

  • PDF

터널 탐지를 위한 전기비저항 토모그래피 응용 실험 (Field experiment of ERT to detect a tunnel)

  • 이명종;김정호;조성준
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 공동학술대회 논문집
    • /
    • pp.215-218
    • /
    • 2007
  • Tunnel detection is known to be one of the challenging problems in geophysical society. Among various geophysical methods, we tried to examine the applicability of electrical resistivity tomography (ERT) method to detect empty tunnel. In this study, we analyzed the ERT data acquired at the test site for tunnel detection. The inversion results have shown reasonable image of the tunnel although the resolution is quite poor. Moreover, we could obtain the three-dimensional attitude of tunnel through 3-D ERT imaging. Therefore, we expect that ERT can make contribution to the tunnel detection problem and further research effort such as fusion of geophysical methods will provide more reliable tunnel detection capability.

  • PDF

2차원 지하구조 규명을 위한 전극배열의 효율성 (Effectiveness of the Electrode Arrays for Delineating 2-D Subsurface Structure)

  • 윤종렬;이기화
    • 자원환경지질
    • /
    • 제29권3호
    • /
    • pp.345-355
    • /
    • 1996
  • 2차원 지하구조를 해석함에 있어 1차원 역산에 근거한 수직탐사자료 해석의 타당성과 수평탐사에 있어 여러가지 전극배열법의 효율성이 연구되었다. 수직암맥, 판상기둥, 매몰수직단층, 램프 (ramp), 복합구조와 같은 2차원 모델로부터 유한차분법을 이용하여 3 포인트, 쌍극자, 베너 (Wenner), 슐럼버저 (Schlumberger) 수평탐사의 겉보기비저항 곡선을 구하고 이를 비교 분석하였다. 수직탐사의 경우에는 슐럼버저와 베너 배열법에 대하여 1차원 역산자료를 내심하여 얻은 자료로부터 2차원 단면도를 구하여 비교하였다. 이러한 2차원 단면도는 각 모델에 대하여 비저항의 수칙, 수평적인 경계면을 잘 보여주고 있다. 또한 슐럼버저 수평탐사의 겉보기 비저항 곡선은 수직적인 비저항의 경계면을 잘 보여주고 있다. 전반적으로 수직, 수평 전기탐사의 경우에 있어 슐럼버저 배열법이 다른 전극배열법보다 우수한 결과를 보여주고 있다. 본 연구로부터, 1차원 역산에 근거한 2차원 지하구조의 해석이 가능함을 알 수 있다.

  • PDF

호주 Victoria주 MT 탐사 자료 해석 (Analysis of MT Data Acquired in Victoria, Australia)

  • 이성곤;이태종;;박인화;송윤호
    • 지구물리와물리탐사
    • /
    • 제11권3호
    • /
    • pp.184-196
    • /
    • 2008
  • 호주 Victoria주 Bendigo 북부 지역에서 심부 지질 구조를 조사하기 위하여 MT 탐사를 수행하였다. 이 탐사의 주 목적은 이 지역에 발달한 단층대의 연장 상황을 파악하는데 일차적으로 그 목적이 있다. 총 11일에 걸쳐 71개의 측점에서 MT시계열을 획득하였으며 이와 동시에 원거리기준점에서도 자료를 획득하여 자료 처리 및 해석의 신뢰도를 향상시키고자 하였다. 획득된 자료는 임피던스 추출, 원거리기준점 자기장을 이용한 로버스트 자료처리 등을 거쳐 임피던스를 추출하였으며, 3차원 역산 알고리듬을 이용하여 최종적으로 전기비저항 영상을 획득하였다. 이러한 MT 탐사 결과를 이 지역에 대한 지질 자료 및 동일한 측선에서의 탄성파 반사법 자료와 비교한 결과 상호 부합함을 알 수 있었으며 이 지역에 발달된 단층대의 연장 상황을 파악할 수 있었다.