• 제목/요약/키워드: 3D Master Model

검색결과 69건 처리시간 0.033초

MARS/MASTER Solution to OECD Main Steam Line Break Benchmark Exercise III

  • Jeong, Jae-Jun;Joo, Han-Gyu;Chung, Bub-Dong;Ha, Kwi-Seok;Lee, Won-Jae;Cho, Byung-Oh;Zee, Sung-Quun
    • Nuclear Engineering and Technology
    • /
    • 제32권3호
    • /
    • pp.214-226
    • /
    • 2000
  • In an effort to assess the performance of KAERI's coupled 3D kinetics - system T/H code, MARS/MASTER, Exercise III of the OECD main steam line break benchmark is solved. The analysis model of the reference plant, TMI-1 - a 2772 MWth B&W plant, consists of three major components: a core neutronics model involving 241$\times$28 neutronic nodes, a vessel 3D T/H model consisting of 374 hydrodynamic volumes, and a 1D system T/H model containing 157 hydrodynamic volumes. The results show that there is a significant amount of flow mixing occurring in the upper and lower plenum regions and the core power distribution evolves to a highly localized shape due to the presence of a stuck rod, as well as the asymmetric flow distribution. It is judged that MARS/MASTER properly captures these drastic 3-dimensional effects. Comparisons with other results submitted to OECD confirm the accuracy of the MARS/MASTER solution.

  • PDF

자동차 타이어 모델의 곡면 모델링 및 5축 NC 가공 (Surface Modeling and 5-axis NC machining of Automobile Tire Model)

  • 이철수
    • 산업공학
    • /
    • 제9권2호
    • /
    • pp.129-141
    • /
    • 1996
  • Recently, the tire mold of a passenger car is made almost via aluminum casting, and it is necessary to prepare a master model of the tire for the casting. Because of the geometrical feature of tire, as well known, the master model must be machined by a 5-axis NC machine. The paper proposes a procedure to model and machine the master model. The approach includes (a) transformation of 2D drawing of tire into 3D geometry, (b) modeling surfaces of tire, and (c) inverse kinematics of a 5-axis NC machine. An implementation of the proposed procedure is also presented.

  • PDF

SMART연구로 사용후 연료 저장조의 임계해석에 HELIOS-MASTER계산체계의 적용 (Application of the HELIOS-MASTER Code System on the Criticality Analysis for the SMART-P Spent Fuel Storage)

  • 김하용;구본승;김교윤;이정찬;지성균
    • Journal of Radiation Protection and Research
    • /
    • 제30권2호
    • /
    • pp.61-67
    • /
    • 2005
  • 노심설계 해석체계로 사용하는 HELIOS-MASTER코드를 이용하여 SAMRT연구로 사용 후 핵연료 저장조에 대한 임계도 해석체계를 개발하였다. 저장조의 기하학적 모형에 대한 거시 단면적을 HELIOS코드를 이용하여 생산하고, 저장조의 3차원 모델에 대한 임계도를 MASTER코드로 평가하였다. 또한 3차원 MCNP계산을 통하여 HELIOS-MASTER체계를 이용한 임계도 평가의 타당성을 검증하였다 HELIOS-MASTER코드 체계를 이용한 임계도 해석결과가 약간 보수적인 방향으로 허용오차 범위 내에서 정확도를 유지하였다. HELIOS-MASTER 코드 체계는 3차원 연소계산이 가능하기 때문에 차후에 연소이력을 고려한 사용후 연료 저장조에 대한 임계해석에 유용할 것이다.

R/P 마스터 모델을 활용한 정밀주조 부품 및 쾌속금형 제작 공정기술의 개발 (Development of Rapid Tooling using Investment Casting & R/P Master Model)

  • 정해도;김화영
    • 한국주조공학회지
    • /
    • 제20권5호
    • /
    • pp.330-335
    • /
    • 2000
  • Functional metal prototypes are often required in numerous industrial applications. These components are typically needed in the early stage of a project to determine form, fit and function. Recent R/P(Rapid Prototyping) part are made of soft materials such as plastics, wax, paper, these master models cannot be employed durable test in real harsh working environment. Parts by direct metal rapid tooling method, such as laser sintering, by now are hard to get net shape, pores of the green parts of powder casting method must be infiltrated to get proper strength as tool, and new type of 3D direct tooling system combining fabrication welding arc and cutting process is reported. But a system which can build directly 3D parts of high performance functional material as metal park would get long period of system development, massive investment and other serious obstacles, such as patent. In this paper, through the rapid tooling process as silicon rubber molding using R/P master model, and fabricate wax pattern in that silicon rubber mold using vacuum casting method, then we translated the wax patterns to numerous metal tool prototypes by new investment casting process combined conventional investment casting with rapid prototyping & rapid tooling process. With this wax-injection-mold-free investment casting, we developed new investment casting process of fabricating numerous functional metal prototypes from one master model, combined 3-D CAD, R/P and conventional investment casting and tried to expect net shape measuring total dimension shrinkage from R/P pare to metal part.

  • PDF

사진 주사(走査)를 이용한 치과용 모형재의 정확도에 관한 연구 (A STUDY ON THE ACCURACY OF DENTAL CAST AND DIE MATERIALS USING PHOTO-SCANNING)

  • 양성욱;임주환;조인호
    • 대한치과보철학회지
    • /
    • 제34권2호
    • /
    • pp.320-334
    • /
    • 1996
  • Dental cast and die materials are essential material using in almost dental prsthodontic procedure and it's most important requirement is accuracy for reqorducing the oral anatomical structures. In this study, 5 abutments A, B, C, D, E were fabricated on the metal master model to simulate the arch form and specimens were poured with 4 cast materials. Inter-abutment distances, A-B, A-C, A-D, A-E, B-C, B-D were calculated using the photo-scanning and the deviations from the metal master model were also evaluated. The results were as follows; 1. The distance between A-B, A-C, A-D, A-E, B-C, B-D of the abutments A, B, C, D, E of each cast material was calculated. And after comparing the deviations between the metal master model. $Fujirock^{(R)}$ showed the lowest value with $0.20{\pm}0.22mm$, and the deviation increased in the order of $Suprastone^{(R)}$, Epoxy $Die^{(R)}$, Die $Keen^{(R)}$. There was significant difference between $Fujirock^{(R)}$ and Epoxy $Die^{(R)}$, Die $Keen^{(R)}$. 2. In each calculation area, the difference in measurements between cast material and metal master model showed singificant difference between A-B and Cross arch measure-ments of A-D, B-D, A-E(p<0.05). 3. The difference in measurements between cast material and metal master model in the A-B area showed $Fujirock^{(R)}$ to be the lowest with $0.05{\pm}0.04$mm and increased in the order of Die $Keen^{(R)}$, $Suprastone^{(R)}$, Epoxy $Dies^{(R)}$. There was significant difference between $Fujirock^{(R)}$ and $Suprastone^{(R)}$, Epoxy $Die^{(R)}$ (p<0.05). 4. The difference in measurements between cast material and metal master model in the B-C area showed $Fujirock^{(R)}$ to bo the lowest with $0.17{\pm}0.11$mm and increased in the order of $Suprastone^{(R)}$, Die $Keen^{(R)}$, Epoxy $Dies^{(R)}$. There was significant difference between $Fujirock^{(R)}$ and Die $Keen^{(R)}$, Epoxy $Die^{(R)}$(p<0.05). 5. The difference in measurements between cast material and metal master model in the B-D area showed $Fujirock^{(R)}$ to bo the lowest with $0.13{\pm}0.07$mm, Epoxy $Dies^{(R)}$and increased in the order of $Suprastone^{(R)}$, Die $Keen^{(R)}$. There was significant difference between $Fuji-rock^{(R)}$ and Die Keen(p<0.05). 6. In this experiment, Epoxy $Dies^{(R)}$ showed mean contraction in every calculation area. And when reconstruction cross arch restorations it is thought that distortion should be considered in every cast material.

  • PDF

스캐닝 시스템과 하악용 가변형 트레이의 재현성 (Scanning System and Reproduction of Adjustable Lower Dental Impression Tray)

  • 차영엽;엄상호
    • 제어로봇시스템학회논문지
    • /
    • 제17권3호
    • /
    • pp.254-257
    • /
    • 2011
  • This study was performed to development a dental three-dimensional laser scanning system and measure the accuracy of new adjustable lower dental impression trays. Multiple impressions of a resin master model were made with custom, stock and new adjustable trays and vinyl polysiloxane impression material. The lower master model and resulting cast were compared using an dental scanning system. Each 3D image was superimposed onto the lower master model image and analyzed with custom software. Multiple measurements of the lower master model and casts were analyzed to determine the accuracy of tray types.

3차원 선박 CAD를 위한 배관 의장품의 Part Master 정보 구축 (On the Development of Pipe Equipment in 3D Ship CAD)

  • 이장현;이황범;황세윤;하성국;이찬우
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.819-824
    • /
    • 2007
  • Outfitting system in ship design has huge kinds of standard part. Data base of and automatic design procedure of part master should be included in ship cad in order to reduce the design time. Present study shows an process of part master DB construction of pipe equipments using 3-dimensional CAD environment Attribute and properties of part masters are chosen from JIS standard. As the schema of part masters are stored in data base, 3D geometric model is parsed from the schema.

  • PDF

국내산 구강스캐너(eZIS)를 사용한 3D프린트 모형의 정확도 검증 실험 (Accuracy Verification of 3D printing model by Using Domestic Oral Scanner(eZIS))

  • 변태희;남민경;김정호;김부섭
    • 대한치과기공학회지
    • /
    • 제40권3호
    • /
    • pp.115-123
    • /
    • 2018
  • Purpose: The purpose of this study was establishing process of manufacturing dental prosthesis by using eZIS system(DDS Inc.,Korea). Methods: To evaluate accuracy verification, the test was practiced two ways. First, Comparison of 3D printing models and stone models was practiced by using 3D superimposing software. #36 prepared master model was scanned by eZIS system and three 'Veltz3D' 3D printing models and three 'Bio3D' 3D printing models were manufactured. three stone models were manufactured by conventional impression technique. Second, Fitness test was practiced. the 3D printing models and the stone models was compared by manufacturing same resin crown. #36 prepared master model was scanned 9 times and manufactured (milled) 9 resin crowns by eZIS system. These crowns were cemented three 'Veltz3D' 3D printing models, three 'Bio3D' 3D printing models and three stone models. These crowns were sliced mesiodistal axis and gaps were measured by digital microscope. Results: The average accuracy of Bio3D models were 65.75%. Veltz3D(Hebsiba) models were 60.11% Stone models were 41.00%. Conclusion : This study results showed 3D printing model is similar with stone model. So it was under clinical allow, didn't affect final dental prothesis. There were no significant differences in the appearance of the three types of milling crowns.

치과용 스캐너의 광원에 따른 디지털 모형의 정확도 비교연구 (Comparative study of accuracy of digitized model fabricated by difference optical source of non-contact 3D dental scanner)

  • 김재홍;이정수;심정석
    • 대한치과기공학회지
    • /
    • 제39권4호
    • /
    • pp.227-233
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the validity of digital models fabricated by difference optical source of non-contact 3D dental scanner. Methods: A master model with the prepared upper full arch tooth was used. Stone model(N=10) were produced from master model, and on the other hands, digital models were made with the 3D dental scanner(Blue, white, red optical source). The linear distance between the reference points were measured and analyzed on the Delcam $Copycad^{(R)}$ graphic software. The results were statistically analyzed using the one-way ANOVA and Tukey's HSD test(${\alpha}=0.05$). Results: There were considerable differences in mean values between optical source within each color(blue, white, red), and this difference was not statistically significant(p>0.05). Conclusion : Three different color of dental scanner optical source showed clinically acceptable accuracies of full arch digital model produced by them. Besides, these results will have to be confirmed in further clinical studies.

Sorption of Eu on MX-80 Bentonite in Na-Ca-Cl Brine Solutions

  • Yang, Jieci;Racette, Joshua;Garcia, Fabiola Guido;Nagasaki, Shinya;Yang, Tammy
    • 방사성폐기물학회지
    • /
    • 제20권2호
    • /
    • pp.151-160
    • /
    • 2022
  • The sorption of Eu on MX-80 bentonite in Na-Ca-Cl solutions is investigated at a molal proton concentration (pHm) range of 3 to 10 and an ionic strength (I) range of 0.1 to 6 m (mol·kgw-1). The sorption equilibrium of Eu on MX-80 is achieved within 14 to 21 d at I = 0.1 and 6 m. The sorption distribution coefficient (Kd) values of Eu for MX-80 increase as pHm increases from 3 to 6 for all I values, and they are independent of pHm between 8 and 10 at I ≥ 0.5 m. Meanwhile, at I = 0.1 m, the Kd value at pHm = 10 is slightly lower than those at pHm = 8 and 9. The Kd values are not affected by the I values between 0.5 m and 6 m, whereas the Kd value at I = 0.1 m is greater than those at I ≥ 0.5 m, except at pHm = 10. A two-site protolysis nonelectrostatic surface complexation and cation exchange sorption model is applied to the Eu sorption data for I ≤ 4 m, and the equilibrium constants of the sorption reactions are estimated.