• Title/Summary/Keyword: 3D Master Model

Search Result 69, Processing Time 0.02 seconds

MARS/MASTER Solution to OECD Main Steam Line Break Benchmark Exercise III

  • Jeong, Jae-Jun;Joo, Han-Gyu;Chung, Bub-Dong;Ha, Kwi-Seok;Lee, Won-Jae;Cho, Byung-Oh;Zee, Sung-Quun
    • Nuclear Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.214-226
    • /
    • 2000
  • In an effort to assess the performance of KAERI's coupled 3D kinetics - system T/H code, MARS/MASTER, Exercise III of the OECD main steam line break benchmark is solved. The analysis model of the reference plant, TMI-1 - a 2772 MWth B&W plant, consists of three major components: a core neutronics model involving 241$\times$28 neutronic nodes, a vessel 3D T/H model consisting of 374 hydrodynamic volumes, and a 1D system T/H model containing 157 hydrodynamic volumes. The results show that there is a significant amount of flow mixing occurring in the upper and lower plenum regions and the core power distribution evolves to a highly localized shape due to the presence of a stuck rod, as well as the asymmetric flow distribution. It is judged that MARS/MASTER properly captures these drastic 3-dimensional effects. Comparisons with other results submitted to OECD confirm the accuracy of the MARS/MASTER solution.

  • PDF

Surface Modeling and 5-axis NC machining of Automobile Tire Model (자동차 타이어 모델의 곡면 모델링 및 5축 NC 가공)

  • Lee, Cheol-Soo
    • IE interfaces
    • /
    • v.9 no.2
    • /
    • pp.129-141
    • /
    • 1996
  • Recently, the tire mold of a passenger car is made almost via aluminum casting, and it is necessary to prepare a master model of the tire for the casting. Because of the geometrical feature of tire, as well known, the master model must be machined by a 5-axis NC machine. The paper proposes a procedure to model and machine the master model. The approach includes (a) transformation of 2D drawing of tire into 3D geometry, (b) modeling surfaces of tire, and (c) inverse kinematics of a 5-axis NC machine. An implementation of the proposed procedure is also presented.

  • PDF

Application of the HELIOS-MASTER Code System on the Criticality Analysis for the SMART-P Spent Fuel Storage (SMART연구로 사용후 연료 저장조의 임계해석에 HELIOS-MASTER계산체계의 적용)

  • Kim, Ha-Yong;Koo, Bon-Seung;Kim, Kyo-Youn;Lee, Chung-Chan;Zee, Sung-Quun
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.2
    • /
    • pp.61-67
    • /
    • 2005
  • The criticality analysis method using HELIOS-MASTER code system, which is the nuclear core analysis code system, was developed for the spent fuel storage of SMART-P reactor. We generated the macroscopic cross section of the geometric model with HELIOS and estimated the criticality of the 3-dimensional model with MASTER for SMART-P spent fuel storage. The validity of criticality analysis method for SMART-P spent fuel storage with the HELIOS-MASTER code system by 3-D MCNP calculation was also verified. The result of the criticality analysis with the HELIOS-MASTER code system is more conservative than that with the MCNP and the accuracy of this result is within the range of an allowable error. Because HELIOS-MASTER can perform the 3-D depletion calculation lot a spent fuel storage, it will be useful to perform the criticality analysis including a burnup credit in future.

Development of Rapid Tooling using Investment Casting & R/P Master Model (R/P 마스터 모델을 활용한 정밀주조 부품 및 쾌속금형 제작 공정기술의 개발)

  • Jeong, Hae-Do;Kim, Hwa-Young
    • Journal of Korea Foundry Society
    • /
    • v.20 no.5
    • /
    • pp.330-335
    • /
    • 2000
  • Functional metal prototypes are often required in numerous industrial applications. These components are typically needed in the early stage of a project to determine form, fit and function. Recent R/P(Rapid Prototyping) part are made of soft materials such as plastics, wax, paper, these master models cannot be employed durable test in real harsh working environment. Parts by direct metal rapid tooling method, such as laser sintering, by now are hard to get net shape, pores of the green parts of powder casting method must be infiltrated to get proper strength as tool, and new type of 3D direct tooling system combining fabrication welding arc and cutting process is reported. But a system which can build directly 3D parts of high performance functional material as metal park would get long period of system development, massive investment and other serious obstacles, such as patent. In this paper, through the rapid tooling process as silicon rubber molding using R/P master model, and fabricate wax pattern in that silicon rubber mold using vacuum casting method, then we translated the wax patterns to numerous metal tool prototypes by new investment casting process combined conventional investment casting with rapid prototyping & rapid tooling process. With this wax-injection-mold-free investment casting, we developed new investment casting process of fabricating numerous functional metal prototypes from one master model, combined 3-D CAD, R/P and conventional investment casting and tried to expect net shape measuring total dimension shrinkage from R/P pare to metal part.

  • PDF

A STUDY ON THE ACCURACY OF DENTAL CAST AND DIE MATERIALS USING PHOTO-SCANNING (사진 주사(走査)를 이용한 치과용 모형재의 정확도에 관한 연구)

  • Yang, Seong-Wook;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.2
    • /
    • pp.320-334
    • /
    • 1996
  • Dental cast and die materials are essential material using in almost dental prsthodontic procedure and it's most important requirement is accuracy for reqorducing the oral anatomical structures. In this study, 5 abutments A, B, C, D, E were fabricated on the metal master model to simulate the arch form and specimens were poured with 4 cast materials. Inter-abutment distances, A-B, A-C, A-D, A-E, B-C, B-D were calculated using the photo-scanning and the deviations from the metal master model were also evaluated. The results were as follows; 1. The distance between A-B, A-C, A-D, A-E, B-C, B-D of the abutments A, B, C, D, E of each cast material was calculated. And after comparing the deviations between the metal master model. $Fujirock^{(R)}$ showed the lowest value with $0.20{\pm}0.22mm$, and the deviation increased in the order of $Suprastone^{(R)}$, Epoxy $Die^{(R)}$, Die $Keen^{(R)}$. There was significant difference between $Fujirock^{(R)}$ and Epoxy $Die^{(R)}$, Die $Keen^{(R)}$. 2. In each calculation area, the difference in measurements between cast material and metal master model showed singificant difference between A-B and Cross arch measure-ments of A-D, B-D, A-E(p<0.05). 3. The difference in measurements between cast material and metal master model in the A-B area showed $Fujirock^{(R)}$ to be the lowest with $0.05{\pm}0.04$mm and increased in the order of Die $Keen^{(R)}$, $Suprastone^{(R)}$, Epoxy $Dies^{(R)}$. There was significant difference between $Fujirock^{(R)}$ and $Suprastone^{(R)}$, Epoxy $Die^{(R)}$ (p<0.05). 4. The difference in measurements between cast material and metal master model in the B-C area showed $Fujirock^{(R)}$ to bo the lowest with $0.17{\pm}0.11$mm and increased in the order of $Suprastone^{(R)}$, Die $Keen^{(R)}$, Epoxy $Dies^{(R)}$. There was significant difference between $Fujirock^{(R)}$ and Die $Keen^{(R)}$, Epoxy $Die^{(R)}$(p<0.05). 5. The difference in measurements between cast material and metal master model in the B-D area showed $Fujirock^{(R)}$ to bo the lowest with $0.13{\pm}0.07$mm, Epoxy $Dies^{(R)}$and increased in the order of $Suprastone^{(R)}$, Die $Keen^{(R)}$. There was significant difference between $Fuji-rock^{(R)}$ and Die Keen(p<0.05). 6. In this experiment, Epoxy $Dies^{(R)}$ showed mean contraction in every calculation area. And when reconstruction cross arch restorations it is thought that distortion should be considered in every cast material.

  • PDF

Scanning System and Reproduction of Adjustable Lower Dental Impression Tray (스캐닝 시스템과 하악용 가변형 트레이의 재현성)

  • Cha, Young-Youp;Eom, Sang-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.3
    • /
    • pp.254-257
    • /
    • 2011
  • This study was performed to development a dental three-dimensional laser scanning system and measure the accuracy of new adjustable lower dental impression trays. Multiple impressions of a resin master model were made with custom, stock and new adjustable trays and vinyl polysiloxane impression material. The lower master model and resulting cast were compared using an dental scanning system. Each 3D image was superimposed onto the lower master model image and analyzed with custom software. Multiple measurements of the lower master model and casts were analyzed to determine the accuracy of tray types.

On the Development of Pipe Equipment in 3D Ship CAD (3차원 선박 CAD를 위한 배관 의장품의 Part Master 정보 구축)

  • Lee, Jang-Hyun;Lee, Hwang-Beom;Hwang, Se-Yun;Ha, Sung-Cook;Lee, Chan-Woo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.819-824
    • /
    • 2007
  • Outfitting system in ship design has huge kinds of standard part. Data base of and automatic design procedure of part master should be included in ship cad in order to reduce the design time. Present study shows an process of part master DB construction of pipe equipments using 3-dimensional CAD environment Attribute and properties of part masters are chosen from JIS standard. As the schema of part masters are stored in data base, 3D geometric model is parsed from the schema.

  • PDF

Accuracy Verification of 3D printing model by Using Domestic Oral Scanner(eZIS) (국내산 구강스캐너(eZIS)를 사용한 3D프린트 모형의 정확도 검증 실험)

  • Byun, Tae-hee;Nam, Min-kyung;Kim, Jung-ho;Kim, Busob
    • Journal of Technologic Dentistry
    • /
    • v.40 no.3
    • /
    • pp.115-123
    • /
    • 2018
  • Purpose: The purpose of this study was establishing process of manufacturing dental prosthesis by using eZIS system(DDS Inc.,Korea). Methods: To evaluate accuracy verification, the test was practiced two ways. First, Comparison of 3D printing models and stone models was practiced by using 3D superimposing software. #36 prepared master model was scanned by eZIS system and three 'Veltz3D' 3D printing models and three 'Bio3D' 3D printing models were manufactured. three stone models were manufactured by conventional impression technique. Second, Fitness test was practiced. the 3D printing models and the stone models was compared by manufacturing same resin crown. #36 prepared master model was scanned 9 times and manufactured (milled) 9 resin crowns by eZIS system. These crowns were cemented three 'Veltz3D' 3D printing models, three 'Bio3D' 3D printing models and three stone models. These crowns were sliced mesiodistal axis and gaps were measured by digital microscope. Results: The average accuracy of Bio3D models were 65.75%. Veltz3D(Hebsiba) models were 60.11% Stone models were 41.00%. Conclusion : This study results showed 3D printing model is similar with stone model. So it was under clinical allow, didn't affect final dental prothesis. There were no significant differences in the appearance of the three types of milling crowns.

Comparative study of accuracy of digitized model fabricated by difference optical source of non-contact 3D dental scanner (치과용 스캐너의 광원에 따른 디지털 모형의 정확도 비교연구)

  • Kim, Jae-Hong;Lee, Jung-Soo;Shim, Jeong-Seok
    • Journal of Technologic Dentistry
    • /
    • v.39 no.4
    • /
    • pp.227-233
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the validity of digital models fabricated by difference optical source of non-contact 3D dental scanner. Methods: A master model with the prepared upper full arch tooth was used. Stone model(N=10) were produced from master model, and on the other hands, digital models were made with the 3D dental scanner(Blue, white, red optical source). The linear distance between the reference points were measured and analyzed on the Delcam $Copycad^{(R)}$ graphic software. The results were statistically analyzed using the one-way ANOVA and Tukey's HSD test(${\alpha}=0.05$). Results: There were considerable differences in mean values between optical source within each color(blue, white, red), and this difference was not statistically significant(p>0.05). Conclusion : Three different color of dental scanner optical source showed clinically acceptable accuracies of full arch digital model produced by them. Besides, these results will have to be confirmed in further clinical studies.

Sorption of Eu on MX-80 Bentonite in Na-Ca-Cl Brine Solutions

  • Yang, Jieci;Racette, Joshua;Garcia, Fabiola Guido;Nagasaki, Shinya;Yang, Tammy
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.20 no.2
    • /
    • pp.151-160
    • /
    • 2022
  • The sorption of Eu on MX-80 bentonite in Na-Ca-Cl solutions is investigated at a molal proton concentration (pHm) range of 3 to 10 and an ionic strength (I) range of 0.1 to 6 m (mol·kgw-1). The sorption equilibrium of Eu on MX-80 is achieved within 14 to 21 d at I = 0.1 and 6 m. The sorption distribution coefficient (Kd) values of Eu for MX-80 increase as pHm increases from 3 to 6 for all I values, and they are independent of pHm between 8 and 10 at I ≥ 0.5 m. Meanwhile, at I = 0.1 m, the Kd value at pHm = 10 is slightly lower than those at pHm = 8 and 9. The Kd values are not affected by the I values between 0.5 m and 6 m, whereas the Kd value at I = 0.1 m is greater than those at I ≥ 0.5 m, except at pHm = 10. A two-site protolysis nonelectrostatic surface complexation and cation exchange sorption model is applied to the Eu sorption data for I ≤ 4 m, and the equilibrium constants of the sorption reactions are estimated.