• Title/Summary/Keyword: 3D MOTION ANALYSIS

Search Result 743, Processing Time 0.034 seconds

Kinematic Analysis of Acopian in Vault (도마종목 Kasamatsu계의 Akopian 기술동작 분석)

  • Lee, Soon-Ho;Park, Jong-Hoon;Lee, Chong-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.1
    • /
    • pp.89-99
    • /
    • 2006
  • The study were to assess technical factors between the high score group and the low score group, from the subjects of 16 male national gymnasts, and to analyze the kinematical characteristic and main technical cause on technique of Akopian's 3D motion analysis of the male vaulting game in 2001 classification championship. The result of this study is this. There were not so much difference between the two groups in term; of the time of board contact, pre-flight, and total performance, but it takes shorter time when the players who are in the high point group take down the board, and they take long time for post-flight(p<.01). The high point group has a longer perpendicular distance in the moment of horse taking off, 0.05m on the average, than the low point group. The high point group shows 0.16m higher on the average than the other group in term; of the height of post-flight(p<.01). In the phase of board contact, the range of horizontal velocity at board take on were $7.66m/s{\sim}7.33m/s$, but there weren't significantly statistic differences between two groups. The hight score group were 0.68m/s faster than the low point group at the horizontal velocity at board take off event(<.05). About the average horizontal velocity of deceleration, AG1(-1.95m/s) reduces the speed more than AG2(-1.57m/s)(p<.05). And the hight score group were 0.37m/s faster than the low point group at the vertical velocity at horse take off event(<.05). When board taking off, the projectile angle of com were $38.7{\sim}37.8degree$ on the average. the comparative groups show almost same results. When horse taking off, the HPVy of the high point group were 37.6 degree which were a little higher than the low point group. The angular velocities of the players who takes on the horse with a right hand and then takes off with a left hand in the high point group were 14.97rad/sec, 10.82rad/sec in the low point group. However, the angular velocity of the players who takes on the horse with a left hand and then takes off on a right hand with the high point group were 14.97rad/sec, 15.56rad/sec in the low point group.

The Effect of Robot Therapy on Upper Extremity Function in a Patient With Parkinson's Disease (로봇치료가 파킨슨병 환자의 상지 기능에 미치는 영향)

  • Lee, Inseon;Kim, Jongbae;Park, Ji-Hyuk;Park, Hae Yean
    • Therapeutic Science for Rehabilitation
    • /
    • v.7 no.3
    • /
    • pp.59-78
    • /
    • 2018
  • Objective : The purpose of this study was to investigate the effect of robot-assisted therapy on upper extremity function. Methods : This study used a single-subject experimental A-B-A' design. Three Parkinson's disease patients took part. Each subject received a robot-assisted therapy intervention (45 min/session, 5 sessions/week for 4 weeks). Upper extremity movement was evaluated with the Reo Assessment tool in Reogo. The Jebsen-Taylor hand motor function test, Fugle-Mayer Assessment score, Box and Block Test, and Nine-hole pegboard test were assessed pre- and post-intervention. Results : After intervention, all subjects underwent 3D motion analysis of reaching function. There was overall improvement in resistance, smoothness, direction accuracy, path efficiency, initiation time, and time to moving target with robot-assisted therapy. Robot-assisted therapy may have a positive effect on upper extremity movement in Parkinson's disease. Conclusion : Robot-assisted therapy is considered an alternative in clinical occupational therapy to improve upper extremity function in Parkinson's disease.

The Kinematic analysis of the third Hurdling motions of The 110m Hurdles Elite (엘리트 110m 허들선수의 세 번째 허들링 동작에 관한 운동학적 분석)

  • Lee, Jung-Ho;Park, Young-Jin;Ryu, Jae-Kyun;Kim, Jong-In
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.4
    • /
    • pp.31-39
    • /
    • 2008
  • The purposes of this study were to compare and analyze the world elite hurdler and the domestic hurdler 3-D kinematic and kinetic techniques about hurdling motion in the 110m hurdles. After analyzing variables in the 110m hurdle run the following conclusions were obtained; In a preparation phase, the domestic hurdler came out running more 0.13m then world elite hurdler from grounding to taking off in the height of center of gravity and the distance by 1.04m. In a flight phase, the domestic hurdler came out taking off 0.33m less then world elite hurdler from taking off to flight peak in the height of center of gravity and the distance by 1.63m. In a flight peak phase, domestic hurdler came out landing more 0.37m then world elite hurdler by 159m. More over, during the hurdling, the horizontal velocity of center of gravity came out decreasing from taking off to landing with domestic hurdler by 0.75m/s. the take off percentage and the landing percentage is 53:47. In a acceleration phase, domestic hurdler came out going slower 0.54m/s than world elite hurdler from landing in the horizontal velocity of center of gravity by 8.78m/s.

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

Response evaluation and vibration control of a transmission tower-line system in mountain areas subjected to cable rupture

  • Chen, Bo;Wu, Jingbo;Ouyang, Yiqin;Yang, Deng
    • Structural Monitoring and Maintenance
    • /
    • v.5 no.1
    • /
    • pp.151-171
    • /
    • 2018
  • Transmission tower-line systems are commonly slender and generally possess a small stiffness and low structural damping. They are prone to impulsive excitations induced by cable rupture and may experience strong vibration. Excessive deformation and vibration of a transmission tower-line system subjected to cable rupture may induce a local destruction and even failure event. A little work has yet been carried out to evaluate the performance of transmission tower-line systems in mountain areas subjected to cable rupture. In addition, the control for cable rupture induced vibration of a transmission tower-line system has not been systematically conducted. In this regard, the dynamic response analysis of a transmission tower-line system in mountain areas subjected to cable rupture is conducted. Furthermore, the feasibility of using viscous fluid dampers to suppress the cable rupture-induced vibration is also investigated. The three dimensional (3D) finite element (FE) model of a transmission tower-line system is first established and the mathematical model of a mountain is developed to describe the equivalent scale and configuration of a mountain. The model of a tower-line-mountain system is developed by taking a real transmission tower-line system constructed in China as an example. The mechanical model for the dynamic interaction between the ground and transmission lines is proposed and the mechanical model of a viscous fluid damper is also presented. The equations of motion of the transmission tower-line system subjected to cable rupture without/with viscous fluid dampers are established. The field measurement is carried out to verify the analytical FE model and determine the damping ratios of the example transmission tower-line system. The dynamic analysis of the tower-line system is carried out to investigate structural performance under cable rupture and the validity of the proposed control approach based on viscous fluid dampers is examined. The made observations demonstrate that cable rupture may induce strong structural vibration and the implementation of viscous fluid dampers with optimal parameters can effectively suppress structural responses.

A Comparison of the Shoulder Stabilizer Muscle Activities During Push-up Plus Between Persons With and Without Winging Scapular (푸시업플러스(Push-up plus) 운동 시 견갑골 익상 유무에 따른 어깨안정근의 근활성도 비교)

  • Park, Jun-Sang;Jeon, Hye-Seon;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.14 no.2
    • /
    • pp.44-52
    • /
    • 2007
  • This study was carried out to compare the muscle activities of the shoulder stabilizers between persons with and without winging scapular during push-up plus exercise (adds the scapular protraction to the general push-up exercise). For this study, eleven males with winging scapular and eleven healthy males were recruited. Surface electromyographic (EMG) activity was recorded from the serratus anterior, upper trapezius, lower trapezius, infraspinatus, and pectoralis major while the subjects performed the push-up plus. Each push-up plus was subdivided into three phases according to the elbow position which was measured using the 3-D motion analysis system: elbow flexion (EF), elbow extension (EE), and shoulder protraction phases (SP). Two-way repeated measure ANOVA (phase ${\times}$ group) were used for statistical analysis. There was significant phase by group interaction only on the EMG composition ratio of the serratus anterior (p>.05). The EMG composition ratio of the serratus anterior was significantly higher in SP than in either EF or EE however, it was not different between winging scapular and normal groups. For both groups, the EMG composition ratio of upper trapezius, lower trapezius, and pectoralis major was significantly different across the phases of push-up plus, but the infraspinatus EMG composition ratio was not. For both groups, in EF and EE phases, the EMG composition ratio of both pectoralis major and serratus anterior were relatively higher than that of other muscles. However, in both groups, the EMG composition ratio of the serratus anterior became much more predominant than that of the pectoralis major. In addition, infraspinatus activated greater than pectoralis major. These results showed that the push-up plus exercise is effective to selectively strengthen the serratus anterior for both individuals with and without winging scapular, but not equally effective for other shoulder stabilizers.

  • PDF

Case Study of 4-Bar Linkage KAFO in Person With Poliomyelitis (소아마비에서 4절 연쇄 장하지보조기 사례연구)

  • Kim, Jang-Hwan;Kwon, Oh-Yun;Yi, Chung-Hwi;Cho, Sang-Hyun;Cynn, Heon-Seock;Choi, Heung-Sik
    • Physical Therapy Korea
    • /
    • v.20 no.1
    • /
    • pp.18-27
    • /
    • 2013
  • The purpose of this study was to compare the ring lock type knee-ankle-foot orthosis (KAFO) with newly developed 4-bar linkage KAFO on the gait characteristics of persons with poliomyelitis clinically. This 4-bar linkage is the stance control type KAFO which provide the stability during stance phase and knee flexion during swing phase. Two subjects participated in this study voluntarily. We provided the customized 4-bar linkage KAFO then asked the subjects to walk in level surface and stairs under the two different KAFO conditions. The characteristics of gait in the persons with poliomyelitis were evaluated using a 3D motion analysis system and force plate. Additionally 6 minute walk test for physiological cost index were conducted using pulse oximeter to measure the energy consumption. In the results of this study, the differences of 4-bar linkage KAFO compared with ring lock type KAFO are as follows: (1) Walking speed, stride length, and step length on level increased in subjects, (2) The gait symmetry was improved by generated knee flexion and decreased pelvic external rotation on level and stairs walking, (3) Decreased vertical excursion of center of mass and pelvic elevation during swing phase was decreased on level, (4) Knee extension moment, hip flexion moment, hip and knee internal rotation moment of non-braced limb were decreased on level walking, (5) Walking speed in 6-minute walk test was increased and physiological cost index was decreased. These findings indicate that 4-bar linkage KAFO compared with ring lock type KAFO is effective in enhancing pattern, endurance, and energy consumption in level surface and stairs walking.

Quality Assurance of Multileaf Collimator Using Electronic Portal Imaging (전자포탈영상을 이용한 다엽시준기의 정도관리)

  • ;Jason W Sohn
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.151-160
    • /
    • 2003
  • The application of more complex radiotherapy techniques using multileaf collimation (MLC), such as 3D conformal radiation therapy and intensity-modulated radiation therapy (IMRT), has increased the significance of verifying leaf position and motion. Due to thier reliability and empirical robustness, quality assurance (QA) of MLC. However easy use and the ability to provide digital data of electronic portal imaging devices (EPIDs) have attracted attention to portal films as an alternatives to films for routine qualify assurance, despite concerns about their clinical feasibility, efficacy, and the cost to benefit ratio. In this study, we developed method for daily QA of MLC using electronic portal images (EPIs). EPID availability for routine QA was verified by comparing of the portal films, which were simultaneously obtained when radiation was delivered and known prescription input to MLC controller. Specially designed two-test patterns of dynamic MLC were applied for image acquisition. Quantitative off-line analysis using an edge detection algorithm enhanced the verification procedure as well as on-line qualitative visual assessment. In conclusion, the availability of EPI was enough for daily QA of MLC leaf position with the accuracy of portal films.

  • PDF

A Preliminary Design of Mooring System for Floating Wave Energy Converter (부유식 파력발전장치용 계류시스템의 초기설계)

  • Jung, D.H.;Shin, S.H.;Kim, H.J.;Lee, H.S.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.3
    • /
    • pp.184-191
    • /
    • 2011
  • Preliminary design of a mooring system for a floating wave energy converter(WEC) is performed. A mooring line is designed to consist of two parts; the one is a chain in heavy weight laid on the seabed and linked to an anchor on the seabed and the other is a light weight chain suspended at a floater. A high weight chain laid on the seabed can contribute to mitigate dynamic energy propagated from top oscillation and decrease anchor weight and volume. Through a low weight chain suspended between a floater and seabed the WEC's function to produce energy from wave can be affected in minimum by the motion of a chain. The static and dynamic analyses for the designed mooring system were carried out to evaluate WEC system's safety. The present study shows that the designed gravity anchor moves horizontally due to the tension exerted on the anchor in the severe ocean environmental condition. The present mooring system should be redesigned to satisfy the safety requirements. The present study will be useful to predict the safety of the mooring system under ocean environment.

A Study on Channel 4's Station Identification: focused on 'Modular Typography'

  • John, Adjah;Hong, Mi-Hee
    • Cartoon and Animation Studies
    • /
    • s.42
    • /
    • pp.241-262
    • /
    • 2016
  • British TV Channel 4 is one of the famous TV Channel in the world. Its station ID has also played a leading role in the developments of Motion Graphics including station IDs. This station ID's main visual design concept is its name and an iconic logo '4' at the same time. The first channel 4 station ID was designed by using modular typography to construct the iconic '4'. Modular typography is a technique of creating letters with similar elements. Channel 4's station ID was constructed from coloured polygons. The polygons split and converge at the same point in 3D space. Modularity in Channel 4's station ID is evidenced by the similar units of polygons. After the first station ID, Channel 4 was re-branded. Eventhough the station IDs which followed did not use coloured and geometrical polygons, modularity is seen in most of the station IDs especially between 2004 - 2011. In these station IDs, the iconic '4' is formed from similar natural and environmental objects like rocks, buildings, lights etc. In this analysis paper, there is a visual narrative on the history of Channel 4, the concept of modular typography in the original station ID and the application of modular typography in other Channel 4's station IDs.