• 제목/요약/키워드: 3D MOTION ANALYSIS

검색결과 744건 처리시간 0.027초

뇌전이 환자의 조영 증강 후 지연 FLAIR 영상의 유용성 (Patients with brain metastases the usefulness of contrast-enhanced FLAIR images after delay)

  • 변재후;박명환;이진완
    • 대한디지털의료영상학회논문지
    • /
    • 제16권1호
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: FLAIR image is beneficial for the diagnosis of various bran diseases including ischemic CVS, brain tumors and infections. However the border between the legion of brain metastasis and surrounding edema may not be clear. Therefore, this study aims to investigate the practical benefits of delayed imaging by comparing the image from a patient with brain metastasis before a contrast enhancement and the image 10 minutes after a contrast enhancement. Materials and methods: Of the 92 people who underwent MRI brain metastases in suspected patients 13 people in three patients there is no video to target the 37 people confirmed cases, and motion artifacts brain metastases in our hospital June-December 2013, 18 people measurement position except for the three incorrect patient (male: 11 people, female: 7 people, average age: 60 years) in the target, test equipment, 3.0T MR System (ACHIEVA Release, Philips, I was 8ChannelSENSE Head Coil use Best, and the Netherlands). TR 11000 ms, TE 125 ms, TI2800 ms, Slice Thickness 5 mm, gap 5 mm, is a Slice number 21, the parameters of the 3D FFE, T2 FLAIR variable that was used to test, TR 8.1 ms, TE 3.7 ms, Slice number 240 I set to. The experiment was conducted by acquiring the FLAIR prior to contrast enhancement (heretofore referred to as Pre FLAIR), and acquiring the 3D FFE CE five minutes after the contrast enhancement, and recomposing the images in an axial plane of S/T 3mm, G 0mm (heretofore referred to as MPR TRA CE). Using the FLAIR 10 minutes after the contrast enhancement (heretofore referred to as Post FLAIR) and Pi-View, a retrospective study was conducted. Using MRIcro on the image of a patient confirmed for his diagnosis, the images before and after the contrast media, as well as the CNR and SNR of the MPR TRA CE images of the lesion and the site absent of lesion were compared and analyzed using a one-way analysis of variance. Results: CNR for Pre FLAIR and Post FLAIR were 34.35 and 60.13, respectively, with MPR TRA CE at 23.77 showing no significant difference (p<0.050). Post-experiment analysis shows a difference between Pre FLAIR and Post FLAIR in terms of CNR (p<0.050), but no difference in CNR between Post FLAIR and MPR TRA CE (p>0.050), indicating that the contrast media had an effect only on Pre FLAIR and Post FLAIR. The SNR for the normal site Pre FLAIR was 106.43, and for the lesion site 140.79. Post FLAIR for the normal site was 107.79, and for the lesion site 167.91. MPR TRA CE for the normal site was 140.23 and for the lesion site 183.19, showing significant difference (p<0.050), and post-experiment analysis shows that there was a difference in SNR only on the lesion sites for Pre FLAIR and Post FLAIR (p<0.050). There was no difference in SNR between the normal site and lesion site for Post FLAIR and MPR TRA CE, indicating no effect from the contrast media (p>0.050). Conclusions: This experiment shows that Post FLAIR has a higher contrast than Pre FLAIR, and a higher SNR for lesions, It was not not statistically significant and MPR TRA CE but CNR came out high. Inspection of post-contrast which is used in a high magnetic field is frequently used images of 3D T1 but, since the signal of the contrast medium and the blood flow is included, this method can be diagnostic accuracy is reduced, it is believed that when used in combination with Post FLAIR, and that can provide video information added to the diagnosis of brain metastases.

  • PDF

旋網의 沈降 抵抗 解析 - 2. 網地材料와 沈子量 다른 模型網의 경우 - (An Analysis on the Sinking Resistance of Purse Seine - 2. In the Case of the Model Purse Seine with Different Netting Material and Sinkers -)

  • 김석종
    • 수산해양기술연구
    • /
    • 제40권1호
    • /
    • pp.29-36
    • /
    • 2004
  • 선망의 침강 저항 특성을 해명하기 위한 기초 연구로서, 망지의 재료가 다르고 침자량이 동일한 선망 모형의 침강특성을 해석하였다. 실험에 사용한 선망은, 그물실의 직경 및 발의 길이가 같은 폴리프로피렌系 (밀도 0.91g/cm$cm^3$), 폴리아미드系 (밀도 1.14g/cm$cm^3$) 및 폴리에스터系 (밀도 1.38g/cm$cm^3$)의 매듭 없는 망지를 사용하여, 뜸줄의 길이 420cm, 그물의 폭 86cm가 되도록 제작하였다. 이 그물들의 발줄에 침자를 25g, 45g, 60g 의 3 단계로 바꾸어 9종류의 모형그물을 만들고, 각각 PP-25, PA-25, PES-25, PP-45, PA-45, PES-45, PP-60, PA-60 및 PES-60그물이라고 이름을 붙였다. 회류수조의 수로 위에 투망장치를 설치해서 정지 상태의 수중에 투망하고, 관측부 전면에 설치한 비디오 카메라를 이용하여 촬영 녹화하였다. 그리고, 그물에 표시한 측정점의 좌표를 화상해석장치로 읽고 실험치를 구하였다. 여기서, 선망의 수직방향의 침강운동을 나타낸 이론식을 이용하여 수치해석을 행하였는데, 그 결과는 다음과 같다. 1. 침자량이 60g일 때, 아랫자락의 평균 침강속도는 PES그물 12.2 cm/sec로 가장 빠르고, PA그물 11.4 cm/sec, PP 그물 10.7cm/sec 순으로 늦게 나타났다. 2. 망지의 저항계수 $K_D$는, 계산결과 $K_D=0.09(\frac{\rho}{\rho_w})^4$의 관계식으로 나타낼 수 있었다. 3. 그물다발의 저항계수 $C_R$은, 계산결과 $C_R=0.91(\frac{\rho}{\rho_w})$의 관계식으로 나타낼 수 있었다. 4. 선망 투망후 경과시간에 따른 그물 아랫자락의 도달수심에 대한 실험치와 계산치의 관계는 상관성이 매우 높아, 침자량이 25g일 때 meas.=1.04 cal., 45g일 때 meas.=0.99cal.였으며, 60g일 때 meas.=0.98cal.의 관계를 나타냈다.

뇌졸중 환자의 머리회전 각도가 내.외측 균형에 미치는 영향 (The Effect of Medio-lateral Balance to Head Rotation in Stroke Patient)

  • 이관섭;김중선
    • The Journal of Korean Physical Therapy
    • /
    • 제24권5호
    • /
    • pp.334-339
    • /
    • 2012
  • Purpose: This study was conducted in order to compare the ability to control postural sway during perturbation when stroke patients received postural sway induced by head rotation. Methods: This study included 15 stroke patients and 15 healthy adults. Each group was measured by 3D motion analysis for determination of the angle of the neck in static position and by balance performance monitor for estimation of swaying angle in both neutral posture and head rotation position. These results were then analyzed in order to compare the healthy control group and the stroke patients group. Results: In both static posture ($60.7{\pm}4.81$) and dynamic posture ($51.46{\pm}6.87$, $70.8{\pm}6.55$), significant decreases were observed in the angle of head rotation of the patient group, compared to the healthy group (p<0.05), and significant decreases were observed in the sway angle of the patient group when in the neutral position ($3.62{\pm}7$, $24{\pm}0.60$) and head rotation ($3.04{\pm}0.80$, $51.46{\pm}6.87$), compared to the healthy group (p<0.05). Conclusion: According to these findings, patients with stroke tend to restrict the ROM of head rotation and swaying angle in dynamic posture and maintain their posture instability using limitation of head movement relative to the trunk and sway angle of area which is larger than that of affected side in unaffected side.

Three-dimensional Kinematic Analysis of the Yurchenko Layout with 360-degree Twist in Female Vaults: Deterministic Model and Judges' Scores

  • Park, Cheol-Hee;Kim, Young-Kwan
    • 한국운동역학회지
    • /
    • 제27권1호
    • /
    • pp.9-18
    • /
    • 2017
  • Objective: The purpose of this study was to identify kinematic variables that govern successful performance and judges' scores and to establish correlative relationships among those of Yurchenko layout with a full twist in female vaults. Method: Four video cameras with sampling rate of 60 Hz collected 32 motion data of Yurchenko vaults from twenty-two female participants (age: $18.6{\pm}3.6years$, height: $153.0{\pm}6.5cm$, mass: $44.7{\pm}7.3kg$) during national competition. Posting processing and calculations of kinematic variables were performed in Kwon 3D XP and $Matlab^{(R)}$ programs. Correlation and regression analyses were applied to find the relationships between the obtained scores and kinematic variables. Deterministic model (Hay & Reid, 1988) was used to investigate the strength of correlative relationships among kinematic variables. Results: The obtained scores from the judges' decision were mainly affected by post-flight peak height, horse contact time, knee angle at landing, and horse takeoff angle. Strong blocking during horse contact was required to get successful performance and obtain high scores. Modified deterministic model showed that round-off entrance and takeoff angles and resultant velocity of the center of mass (CM) during the roundoff phase were the starting variables affecting performance in the following kinematics. Knee angle at landing, a highly influential variable on the obtained point, was only determined by judges' decision without significant correlative relationship with previous kinematic variables. Conclusion: The obtained scores highly depended on kinematic variables of post-flight and horse contact phases that were affected by those from the previous phases including round-off postures and resultant velocity of the body center of mass.

개인보호장비 착용이 심폐소생술에 미치는 영향: 119 구급대원을 중심으로 (Effect of wearing personal protective equipment on cardiopulmonary resuscitation: Focusing on 119 emergency medical technicians)

  • 신동민;김승용;신상도;김주현;김태한;김경용;김정희;홍은정
    • 한국응급구조학회지
    • /
    • 제19권3호
    • /
    • pp.19-32
    • /
    • 2015
  • Purpose: This study examined the effect of wearing personal protective equipment (PPE) on cardiopulmonary resuscitation (CPR), positive airway pressure, and the posture of emergency medical technicians (EMTs) when conducting CPR. Methods: Twenty 119 EMTs performed 30:2 CPR on a manikin for 4 min. Imaging data were digitized with Kwon3D XP (version 4.0). Data were collected by analyzing the motion when starting in one cycle, such as pressing to the maximum and in the final position (relaxed), and were analyzed with SPSS 18.0. Results: The angle of the elbow joints was significantly reduced (p < .05). The trunk angle was statistically significantly (p < .01, p < .001) increased. The angular velocities of the shoulder joint and left elbow joint were reduced (p > .05). The angular velocity of the trunk was significantly reduced in the starting and maximum compression postures. The hand-escape time was increased. The average compression depth was increased but not significantly (p > .05). The positive airway pressure was reduced (p > .05). Conclusion: The angle of the elbow joints and the angular velocity of the trunk were reduced, and the angle of the trunk was increased. The success of CPR and positive airway pressure was reduced.

OGLE-2017-BLG-1049: ANOTHER GIANT PLANET MICROLENSING EVENT

  • Kim, Yun Hak;Chung, Sun-Ju;Udalski, A.;Bond, Ian A.;Jung, Youn Kil;Gould, Andrew;Albrow, Michael D.;Han, Cheongho;Hwang, Kyu-Ha;Ryu, Yoon-Hyun;Shin, In-Gu;Shvartzvald, Yossi;Yee, Jennifer C.;Zang, Weicheng;Cha, Sang-Mok;Kim, Dong-Jin;Kim, Hyoun-Woo;Kim, Seung-Lee;Lee, Chung-Uk;Lee, Dong-Joo
    • 천문학회지
    • /
    • 제53권6호
    • /
    • pp.161-168
    • /
    • 2020
  • We report the discovery of a giant exoplanet in the microlensing event OGLE-2017-BLG-1049, with a planet-host star mass ratio of q = 9.53 ± 0.39 × 10-3 and a caustic crossing feature in Korea Microlensing Telescope Network (KMTNet) observations. The caustic crossing feature yields an angular Einstein radius of θE = 0.52 ± 0.11 mas. However, the microlens parallax is not measured because the time scale of the event, tE ≃ 29 days, is too short. Thus, we perform a Bayesian analysis to estimate physical quantities of the lens system. We find that the lens system has a star with mass Mh = 0.55+0.36-0.29 M⊙ hosting a giant planet with Mp = 5.53+3.62-2.87 MJup, at a distance of DL = 5.67+1.11-1.52 kpc. The projected star-planet separation is a⊥ = 3.92+1.10-1.32 au. This means that the planet is located beyond the snow line of the host. The relative lens-source proper motion is μrel ~ 7 mas yr-1, thus the lens and source will be separated from each other within 10 years. After this, it will be possible to measure the flux of the host star with 30 meter class telescopes and to determine its mass.

여름철 UAV 기반 LiDAR, SfM을 이용한 하천 DTM 생성 기법 비교 분석 (Comparative Analysis of DTM Generation Method for Stream Area Using UAV-Based LiDAR and SfM)

  • 고재준;이혁진;박진석;장성주;이종혁;김동우;송인홍
    • 한국농공학회논문집
    • /
    • 제66권3호
    • /
    • pp.1-14
    • /
    • 2024
  • Gaining an accurate 3D stream geometry has become feasible with Unmanned Aerial Vehicle (UAV), which is crucial for better understanding stream hydrodynamic processes. The objective of this study was to investigate series of filters to remove stream vegetation and propose the best method for generating Digital Terrain Models (DTMs) using UAV-based point clouds. A stream reach approximately 500 m of the Bokha stream in Icheon city was selected as the study area. Point clouds were obtained in August 1st, 2023, using Phantom 4 multispectral and Zenmuse L1 for Structure from Motion (SfM) and Light Detection And Ranging (LiDAR) respectively. Three vegetation filters, two morphological filters, and six composite filters which combined vegetation and morphological filters were applied in this study. The Mean Absolute Error (MAE) and Root Mean Square Error (RMSE) were used to assess each filters comparing with the two cross-sections measured by leveling survey. The vegetation filters performed better in SfM, especially for short vegetation areas, while the morphological filters demonstrated superior performance on LiDAR, particularly for taller vegetation areas. Overall, the composite filters combining advantages of two types of filters performed better than single filter application. The best method was the combination of Progressive TIN (PTIN) and Color Indicies of Vegetation Extraction (CIVE) for SfM, showing the smallest MAE of 0.169 m. The proposed method in this study can be utilized for constructing DTMs of stream and thus contribute to improving the accuracy of stream hydrodynamic simulations.

Adult Proximal Humeral Locking Plate Is a Good Alternative Option in the Treatment of Adolescent Subtrochanteric Femur Fractures: A Case Series and Literature Review

  • Ceyhun Caglar;Serhat Akcaalan;Merve Bozer;Mustafa Akkaya
    • Hip & pelvis
    • /
    • 제34권4호
    • /
    • pp.245-254
    • /
    • 2022
  • Purpose: Management of pediatric subtrochanteric femur fractures (SFFs) is difficult. The aim of this study was to evaluate the outcomes of adolescent SFFs treated with adult proximal humeral locking plates (PHLPs). Materials and Methods: A retrospective analysis of 18 adolescents (11 male, 7 female) with a diagnosis of SFF who underwent internal fixation with a PHLP was conducted. Data regarding injury mechanism, fracture pattern, and time to union were recorded for all patients. In addition, a clinical and functional evaluation of patients was performed using the Harris hip score (HHS), Iowa hip score (IHS), modified Merle d'Aubigne-Postel score (MMAPS), Flynn criteria, and hip range of motion (ROM). Results: The mean age of the patients was 12.72±2.05 years (range, 10-16 years). Radiological observation was performed for evaluation of five different injury mechanisms and different fracture patterns in patients. The mean postoperative HHS was 92.27±5.61, the mean IHS was 90.88±6.46, and the mean MMAPS was 17.22±0.94. According to the Flynn criteria, excellent results were achieved in 14 cases and satisfactory results were obtained in four cases. Measurements of the patients' mean hip ROM values were as follows: 17.77±3.52° in extension, 115.27±6.74° in flexion, 43.05±3.48° in abduction, 27.50±4.28° in adduction, 42.22±4.60° in internal rotation, and 42.22±3.91° in external rotation. Conclusion: Surgery performed on adolescent patients using an adult PHLP showed good, safe results. Therefore, it should be considered as an alternative option.

말의 4족 보법에서 속도변화에 따른 전족 움직임의 운동능력 분석 (A Locomotive Analysis on Forelimbs' Movement According to Change in Velocity of Horses' Quadruped Cadence)

  • 현승현;류재청
    • 한국운동역학회지
    • /
    • 제25권4호
    • /
    • pp.483-488
    • /
    • 2015
  • Objective : The purposes of this study was to analyze the locomotive movement of forelimbs according to changes in velocities in the quadruped cadence of horses. Methods : Horses selected as subjects consisted of Jeju pony horses (heights of withers: $1.23{\pm}0.51$). Two camcorders (HDR-HC7/HDV 1080i, Sony Corp, Japan) were used to capture the movement of the horses' forelimbs at a rate of 60 frames/sec. Additionally, raw data was collected from Kwon3D XP motion analysis package ver 4.0 program (Visol, Korea) with DARTFISH (DFKREA., Korea) video software solution. The variables analyzed consisted of 1 step lengths, 1 stride lengths, stance time, swing time, 1 stride time, velocity while walking, and trot of the horses. A two-way ANOVA and paired t-test of the variables by velocity and phase were treated at .05 level of significant difference, statistically. Results : The time elapsed of walk(stance: 0.63 sec[63.86%], swing: 0.35 sec[36.14%], 1 stride time: 0.99 sec respectively) showed significant difference with more delay than that of trot(stance: 0.29 sec[45.73%], swing: 0.34 sec[54.27% ], 1 stride time: 0.63 sec respectively), and also showed significant difference at trot in interaction (stance time>tort swing>walk swing>walk stance). The 1 step lengths and stride lengths in trot showed significant difference with longer than that of walk. Velocity of Trot showed significant difference statistically with higher than that of walk Conclusion : The horses' velocity during 1 step lengths and 1 stride lengths showed a proportional relationship, but the correlation between the horses' velocity and stance time showed a negative relationship during the quadruped cadence.

A novel higher-order shear deformation theory for bending and free vibration analysis of isotropic and multilayered plates and shells

  • Zine, Abdallah;Tounsi, Abdelouahed;Draiche, Kada;Sekkal, Mohamed;Mahmoud, S.R.
    • Steel and Composite Structures
    • /
    • 제26권2호
    • /
    • pp.125-137
    • /
    • 2018
  • In this work, the bending and free vibration analysis of multilayered plates and shells is presented by utilizing a new higher order shear deformation theory (HSDT). The proposed involves only four unknowns, which is even less than the first shear deformation theory (FSDT) and without requiring the shear correction coefficient. Unlike the conventional HSDTs, the present one presents a novel displacement field which incorporates undetermined integral variables. The equations of motion are derived by using the Hamilton's principle. These equations are then solved via Navier-type, closed form solutions. Bending and vibration results are found for cylindrical and spherical shells and plates for simply supported boundary conditions. Bending and vibration problems are treated as individual cases. Panels are subjected to sinusoidal, distributed and point loads. Results are presented for thick to thin as well as shallow and deep shells. The computed results are compared with the exact 3D elasticity theory and with several other conventional HSDTs. The proposed HSDT is found to be precise compared to other several existing ones for investigating the static and dynamic response of isotropic and multilayered composite shell and plate structures.