• Title/Summary/Keyword: 3D LCD

Search Result 232, Processing Time 0.031 seconds

Autostereoscopic Time Multiplexed 2D/3D Display

  • Kim, Dae-Sik;Shestak, Sergey;Cha, Kyung-Hoon;Koo, Jae-Phil;Hwang, Seon-Deok
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1803-1806
    • /
    • 2007
  • We have developed a 2D/3D time sequential LCD autostereoscopic display, which is capable of simultaneous displaying 2D and 3D graphics at a frame rate up to 120 Hz. Left and right sets of viewing zones are formed by a combination of a fast LC shutter and a lenticular lens array.

  • PDF

Development of Digital Image Acquisition Technique for Momentary Positioning of Dynamic Object (동체의 순간 위치결정을 위한 수치영상 획득기법 개발)

  • Han, Seung-Hee;Kang, Joon-Mook
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.4 no.2 s.8
    • /
    • pp.47-54
    • /
    • 1996
  • It needs more than two images which are obtained in real time to decide 3D positioning of dynamic object. Though we use digital camera which is became wide utilization, but it can't obtain sequential image. So, in this study, we constructed momentary image acquisition system using video camera. Also, we took a photograph of LCD timer and dynamic object together for real time stereo image, and we obtained independent digital image from sequential image using video editor. As a result of the study, we could obtain the independent image as true color digital image of $788{\times}550$pixels with 1/100sec accuracy in the same time. And it was good when we tested object target. For comparing 3D positioning accuracy, we could obtained negative with metric camera using B-shutter.

  • PDF

Implementation of Q-Tensor Model into 3-D Finite Element Method (FEM) Numerical Solver

  • Shin, Woo-Jung;Yoon, Hyung-Jin;Won, Tae-Young
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.509-512
    • /
    • 2007
  • In this paper, we report our successful implementation of Q tensor model in threedimensional finite element method (FEM) simulator. The 3D-FEM Q tensor-model-based simulation revealed that the spaly-to-bend transition occurs only at 4 V while the vector-model based FEM solver provides an erroneous transition voltage of 8 V.

  • PDF

Convertible 3D-2D display by use of integral imaging system with plastic fiber array

  • Kim, Young-Min;Choi, Hee-Jin;Cho, Seong-Woo;Kim, Yun-Hee;Kim, Joo-Hwan;Park, Gil-Bae;Lee, Byoung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1482-1485
    • /
    • 2007
  • A three-dimensional (3D)-two-dimensional (2D) convertible display system using a plastic fiber array is proposed. The proposed system has an advantage of making use of a light source for 3D image from an arbitrary location. The optical efficiency of 3D images in the proposed system is enhanced compared with previous research.

  • PDF

3D Video Quality Assessment Method based on Smoothness of Disparity (Disparity의 smoothness를 이용한 3D 비디오 품질 평가방법)

  • Lee, Seonoh;Nam, Junghak;Jang, Hyeongmoon;Yoo, Sunmi;Sim, Dong-Gyu
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2012.07a
    • /
    • pp.451-452
    • /
    • 2012
  • PDP, LCD, IED 등의 디스플레이 패널 재료를 회두로 생장해 오던 디스플레이 장치 시장이 최근 3D라는 어플리케이션이 화두가 되어 시장 성장을 이끌어 오고 있다. 3D 디스플레이 장치 시장의 규모 및 성장속도에 비해 이를 이용할 수 있도록 하는 3D 서비스는 상대적으로 부족하다. 3D 디스플레이 장치를 확보하는 소비자가 늘어남에 따라 지속적으로 증가하는 3D 서비스에 대한 잠재 수요에 대응하기 위해 다양한 형태의 3D 서비스가 계획되고, 다양한 형태의 콘텐츠 제작이 이루어지고 있다. 3D 디스플레이 장치 및 서비스 시장의 지속적인 성장을 위해서는 제작 및 서비스되는 3D 콘텐츠에 대한 품질 평가 방법에 대한 연구가 선행되어야 한다. 이에 본 논문은 3D 비디오에 대해 사람들이 느끼는 주관적 품질 평가 방법을 제안한다. 하나의 영상 도메인에 표현되던 2D 영상과 달리 스테레오스코픽 비전 방식의 3D 입체 영상은 오른쪽과 왼쪽, 두 개의 영상 도메인에 각 각 표현된다. 또한 양쪽 영상의 차이로 인해 깊이감을 인식할 수 있게 된다. 본 논문에서는 양안에 입력되는 영상의 품질을 각각 측정하고, 두 영상의 차이가 이끌어내는 깊이감을 분석하여 입체영상 전체의 품질 평가에 이용하는 방법을 제안한다.

  • PDF

Removable 3D Object For Mobile Phone Based on J2ME

  • Lee, Song-Won;Hong, Sung-Soo;Kim, Seok-Dong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2009.04a
    • /
    • pp.706-709
    • /
    • 2009
  • The informatization of Korea is accompanied by the great growth of new strategic export industry, as of mobile phone or semiconductor LCD. Speaking to the situation of mobile phone, Motorola swept over the American domestic market in the beginning of 1990s, digital mobile communication as CDMA developed swiftly in Korea. In 1996, the first year's CDMA users of Samsung were merely one million, nevertheless, the world's sales in the first half of this year is up to 92 million. In this p aper I design 3D application based on J2ME and implement a freely removable 3D object which happened in a 3D scen e by receiving the keyboard response of mobile device with WTK (Wireless ToolKit) simulator. It contains benefits of improvement of relative speed and high-level functionality such as scene graph, keyframe animation, etc.

Development of 3D Scanner Based on Laser Structured-light Image (레이저 구조광 영상기반 3차원 스캐너 개발)

  • Ko, Young-Jun;Yi, Soo-Yeong;Lee, Jun-O
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.3
    • /
    • pp.186-191
    • /
    • 2016
  • This paper addresses the development of 3D data acquisition system (3D scanner) based laser structured-light image. The 3D scanner consists of a stripe laser generator, a conventional camera, and a rotation table. The stripe laser onto an object has distortion according to 3D shape of an object. By analyzing the distortion of the laser stripe in a camera image, the scanner obtains a group of 3D point data of the object. A simple semiconductor stripe laser diode is adopted instead of an expensive LCD projector for complex structured-light pattern. The camera has an optical filter to remove illumination noise and improve the performance of the distance measurement. Experimental results show the 3D data acquisition performance of the scanner with less than 0.2mm measurement error in 2 minutes. It is possible to reconstruct a 3D shape of an object and to reproduce the object by a commercially available 3D printer.

Depth and viewing-angle enhanced 3D-2D convertible display system using multiple display devices and a lens array

  • Choi, Hee-Jin;Kim, Yun-Hee;Kim, Joo-Hwan;Cho, Seong-Woo;Lee, Byoung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1565-1568
    • /
    • 2006
  • An improved 3D-2D convertible display system with enhanced depth and viewing angle is proposed. By using the optical structure of an LCD panel, it is possible to enhance the performance of the system and realize the 3D-2D conversion. Some preliminary experimental results will also be provided.

  • PDF

Reality Enhancement Method of Virtual Reality Based Simulator by Mutual Synergy Effect between Stereoscopic Image and Three-Dimensional Sound (입체영상과 3차원음향의 상호 상승효과에 의한 가상현실기반 시뮬레이터 현실감 증대방법)

  • Yim, Jeong-Bin;Kim, Hyeon-Ra
    • Journal of Navigation and Port Research
    • /
    • v.27 no.2
    • /
    • pp.145-153
    • /
    • 2003
  • The presence-feeling enhancement method of a Virtual Reality (VR) simulator is proposed in this paper. The method is to increase realistic human feeling by mutual synergy effect between stereoscopic image and three-dimensional (3D) sound. In order to test the influence of mutual synergy effect, subject assessment with five university students is carried out using VR ship simulator having PC monitor and LCD shutter glasses. It I found that the averaged scale value of image naturalness is increased by 0.5 from $I_{nat}$=3.1 to 3.6 when blending stereoscopic images with 3D sound, and the averaged score value of sound localization is increased by 10% from $A_{SL}$ = 70~75% to $A_{SL}$ = 80~85% when blending 3D sound with stereoscopic image. In conclusion, the results show that the proposed method is able to increase the presence feeling in the VR simulator.

An anomalous dissociation of protonated cluster ions of DNA guanine-cytosine base-pair

  • Seong, Yeon-Mi;Han, Sang-Yun;Jo, Sung-Chan;Oh, Han-Bin
    • Mass Spectrometry Letters
    • /
    • v.2 no.3
    • /
    • pp.73-75
    • /
    • 2011
  • In the collisionally-activated dissociation of the proton-bound cluster ions of DNA base guanine (G) and cytosine (C), $G{\bullet}{\bullet}H^+{\bullet}{\bullet}C$, the abundance of [$CH^+$] ions was found to be higher than that of [$GH^+$] despite the fact that G has a higher proton affinity than C. This unexpected observation seems to demonstrate another example that the simple kinetic method scheme does not work. We suggest that a kinetic factor or detailed dynamics governing the proton transfer and dissociation should be carefully considered in the applications of the kinetic method to the proton affinity measurements.