• Title/Summary/Keyword: 3D Image Scan

Search Result 234, Processing Time 0.031 seconds

A Study on 3D modeling data acquisition method for sculpture scan (조형물 스캔에 대한 3D 모델링데이터 획득 방법연구)

  • Park, Junhong;Lee, Junsang
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.612-614
    • /
    • 2018
  • Today, technologies that can acquire modeling data by using image are emerging. That 3D modeling production method, which is frequently utilized in contents industries, creates modeling data by using creator's intuitive sense, with drawings sketched without accurate measurement tools is also true. Recently, technologies that can facilitate modification and amendment of existing design by producing and reorganizing three-dimensional data of a sculpture through combination of image information are developing. This thesis gives suggestion of how to utilize and study the way to produce accurate three-dimensional modeling data by utilizing multiple image data.

  • PDF

Additive Manufacturing of TMJ Device used in Temporomandibular Joint MRI Scan by using 3D Printer (3D 프린터를 이용하여 턱관절 MRI검사에 사용되는 TMJ device제작)

  • Jang, Hye-Won
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.7
    • /
    • pp.628-634
    • /
    • 2018
  • In an examination of the temporomandibular joint disc, MRI(Magnetic Resonance Imaging) is a useful method, and it is necessary to conduct an examination with one's mouth open for a long time to observe the accurate position change of the disc. Thus, this study would produce a TMJ device, using the 3-D printing technology, which would maintain the state of opening the mouth and would evaluate its usefulness as compared to the existing fixed device. As compared to the image using the existing TMJ device, the image taken with the self-produced TMJ device with a 3-D printer showed a somewhat lower SNR, but there was no defect for a clinical use. It is judged that benefits to costs would increase, since it can be customized for the individual patient and can contribute to the production of similar tools by utilizing the 3-D printing technology.

Development of 3D Image Processing Software using EMD for Ultrasonic NDE (EMD를 이용한 초음파 비파괴 평가용 3차원 영상처리 소프트웨어 개발)

  • Nam, Myung-Woo;Lee, Young-Seock;Yang, Ok-Yul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1569-1573
    • /
    • 2008
  • This paper describes a development of Ultrasonic NDE software to analyze steam generator of nuclear power plant. The developed software includes classical analysis method such as A, B, C and D-scan images. And it can analyze the detected internal cracks using 3D image processing method. To do such, we obtain raw data from specimens of real pipeline of power plants, and get the envelope signal using Empirical Mode Decomposition from obtained ultrasonic 1-dimensional data. The reconstructed 3D crack images offer useful information about the location, shape and size of cracks, even if there is no special 2D image analysis technique. The developed analysis software is applied to specimens containing various cracks with known dimensions. The results of application showed that the developed software provided accurate and enhanced 2D images and reconstructed 3D image of cracks.

Evaluation of Radioactivity Concentration According to Radioactivity Uptake on Image Acquisition of PET/CT 2D and 3D (PET/CT 2D와 3D 영상 획득에서 방사능 집적에 따른 방사능 농도의 평가)

  • Park, Sun-Myung;Hong, Gun-Chul;Lee, Hyuk;Kim, Ki;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.111-114
    • /
    • 2010
  • Purpose: There has been recent interest in the radioactivity uptake and image acquisition of radioactivity concentration. The degree of uptake is strongly affected by many factors containing $^{18}F$-FDG injection volume, tumor size and the density of blood glucose. Therefore, we investigated how radioactivity uptake in target influences 2D or 3D image analysis and elucidate radioactivity concentration that mediate this effect. This study will show the relationship between the radioactivity uptake and 2D,3D image acquisition on radioactivity concentration. Materials and Methods: We got image with 2D and 3D using 1994 NEMA PET phantom and GE Discovery(GE, U.S.A) STe 16 PET/CT setting the ratio of background and hot sphere's radioactivity concentration as being a standard of 1:2, 1:4, 1:8, 1:10, 1:20, and 1:30 respectively. And we set 10 minutes for CT attenuation correction and acquisition time. For the reconstruction method, we applied iteration method with twice of the iterative and twenty times subset to both 2D and 3D respectively. For analyzing the images, We set the same ROI at the center of hot sphere and the background radioactivity. We measured the radioactivity count of each part of hot sphere and background, and it was comparative analyzed. Results: The ratio of hot sphere's radioactivity density and the background radioactivity with setting ROI was 1:1.93, 1:3.86, 1:7.79, 1:8.04, 1:18.72, and 1:26.90 in 2D, and 1:1.95, 1:3.71, 1:7.10, 1:7.49, 1:15.10, and 1:23.24 in 3D. The differences of percentage were 3.50%, 3.47%, 8.12%, 8.02%, 10.58%, and 11.06% in 2D, the minimum differentiation was 3.47%, and the maximum one was 11.06%. In 3D, the difference of percentage was 3.66%, 4.80%, 8.38%, 23.92%, 23.86%, and 22.69%. Conclusion: The difference of accumulated concentrations is significantly increased following enhancement of radioactivity concentration. The change of radioactivity density in 2D image is affected by less than 3D. For those reasons, when patient is examined as follow up scan with changing the acquisition mode, scan should be conducted considering those things may affect to the quantitative analysis result and take into account these differences at reading.

  • PDF

COMPARISON OF SHADE CHANGES ACCORDING TO DRY/WET CONDITION OF TEETH USING INTRA-ORAL COLORIMETER

  • Lee, Dong-Hwan;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.314-321
    • /
    • 2005
  • Objectives. The purpose of this study was to compare the shade changes in wet and dry conditions of natural teeth using two different intra-oral colorimeters. Materials and methods. Twenty volunteer subjects have no restorations and fillings in the maxillary central incisors were involved in this clinical study. The color of tooth was measured by two different instruments that were a Shade $Scan^{TM}$ System and a VITA $Easyshade^{(R)}$, Five times consecutive measurements were done for each subject with both instruments. Groups of measurement are an initial wet condition as control, dry in 5 minutes, 15 seconds after re-wetting with saliva, re-wetting after 5minutes and re-wetting after 30 minutes. Using ShadeScan $System^{TM}$, tooth image was captured and converted to the mapping image of Vitapan 3D master. Three main shades were chosen from each subject and calculated the area in Global Lab Image software. Data were analyzed using paired T-Test and Wilcoxon Signed Ranked Test. Using VITA $Easyshade^{(R)}$, color differences($\Delta$E) between measurements were analyzed with one sample T-test. Results. Using ShadeScan $System^{TM}$, there were significant differences between control group and dry(P=.023), dry and re-wetting 15 seconds, 5 minutes, 30 minutes as well(P=.021, P=.017, P=.030) in comparison of primary shade. However, comparing three main shades, there was no significant difference between control and dry(P=.105). Using VITA $Easyshade^{(R)}$, color differences($\Delta$E) between control and dry, dry and re-wetting 30 minutes were statistically different(P=.002, P=.022). Conclusion. Primary shade could be changed in dry and wetting procedure in time, however there was no significant shade changes in overall.

The Study of automated inspection technology using a three-dimensional reconstruction of stereo X-ray image based dual-sensor Environment (Dual-Sensor 기반 스테레오 X-선 영상의 3차원 형상복원기술을 이용한 검색 자동화를 위한 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho;Kim, Jong-Ryul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.695-698
    • /
    • 2014
  • As most the scanning systems developed until now provide radiation scan plane images of the inspected objects, there has been a limitation in judging exactly the shape of the objects inside a logistics container exactly with only 2-D radiation image information. Two 2-dimensional radiation images which have different disparity values are acquired from a newly designed stereo image acquisition system which has one additional line sensor to the conventional system. Using a matching algorithm the 3D reconstruction process which find the correspondence between the images is progressed. In this paper, we proposed a new volume based 3D reconstruction algorithm and experimental results show the proposed new volume based reconstruction technique can provide more efficient visualization for cargo inspection. The proposed technique can be used for the development of the high speed and more efficient non-destructive auto inspection system.

  • PDF

Studies on the Millimeter-wave Passive Imaging Sensor (밀리미터파 수동 이미징 센서 연구)

  • Jung, Kyung-Kwon;Chae, Yeon-Sik;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.2
    • /
    • pp.1-7
    • /
    • 2008
  • In this paper, we have designed a millimeter-wave passive imaging sensor that is able to use remote sensing and security applications. The brightness temperature distribution of a scene is measured with a antenna at an angular resolution of $3^{\circ}$. The sensor is controlled by a PC, achieving a fast performance by using a pan/tilter. The pan/tilter should be able to scan a 2-D image of the scene, with a linear raster scan pattern. The mechanical scans in azimuth and elevation whereby an image of $20{\times}20$ pixels is acquired within less than 400s. Raw images are immediately displayed and stored for postprocessing.

Change of PET Image According to CT Exposure Conditions (CT 촬영 조건에 따른 PET 영상의 변화)

  • Park, Jae-Yoon;Kim, Jung-hoon;Lee, Yong-Ki
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.473-479
    • /
    • 2019
  • PET-CT improves performance and reduces the time by combining PET and CT of spatial resolution, and uses CT scan for attenuation correction. This study analyzed PET image evaluation. The condition of the tube voltage and current of CT will be changed using. Uniformity phantom and resolution phantom were injected with 37 MBq $^{18}F$ (fluorine ; 511 keV, half life - 109.7 min), respectively. PET-CT (Biograph, siemens, US) was used to perform emission scan (30 min) and penetration scan. And then the collected image data were reconstructed in OSEM-3D. The same ROI was set on the image data with a analyzer (Vinci 2.54, Germany) and profile was used to analyze and compare spatial resolution and image quality through FWHM and SI. Analyzing profile with pre-defined ROI in each phantom, PET image was not influenced by the change of tube voltage or exposure dose. However, CT image was influenced by tube voltage, but not by exposure dose. When tube voltage was fixed and exposure dose changed, exposure dose changed too, increasing dose value. When exposure dose was fixed at 150 mA and tube voltage was varied, the result was 10.56, 24.6 and 35.61 mGy in each variables (in resolution phantom). In this study, attenuation image showed no significant difference when exposure dose was changed. However, when exposure dose increased, the amount of dose that patient absorbed increased too, which indicates that CT exposure dose should be decreased to minimum to lower the exposure dose that patient absorbs. Therefore future study needs to discuss the conditions that could minimize exposure dose that gets absorbed by patient during PET-CT scan.

Reduction of Radiated Emission of an Infrared Camera Using a Spread Spectrum Clock Generator (확산 스펙트럼 생성기를 이용한 적외선 카메라의 방사노이즈 저감에 관한 연구)

  • Choi, Bongjun;Lee, Yongchun;Yoon, Juhyun;Kim, Eunjun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.12
    • /
    • pp.1097-1104
    • /
    • 2016
  • The infrared camera is difficult to satisfy the RE-102 specification of Mil-Std-461. Especially, in the case of UAV electronics, shielded cable is not used, so it is difficult to meet the electromagnetic compatibility standard. In the RE-102 test of the IR camera for UAV, radiated noise exceeding 30 dBuV/m was observed in the range of 50 MHz to 200 MHz. As a result of pcb em scan, peak noise which caused by the harmonic frequency of the digital control signal clock was observed. Radiated noise was reduced by up to 22.9 dBuV/m by applying the spread spectrum clock generator(SSCG) with 3 % down spreading method to the camera control clock.

Geometric calibration of a computed laminography system for high-magnification nondestructive test imaging

  • Chae, Seung-Hoon;Son, Kihong;Lee, Sooyeul
    • ETRI Journal
    • /
    • v.44 no.5
    • /
    • pp.816-825
    • /
    • 2022
  • Nondestructive testing, which can monitor a product's interior without disassembly, is becoming increasingly essential for industrial inspection. Computed laminography (CL) is widely used in this application, as it can reconstruct a product, such as a printed circuit board, into a three-dimensional (3D) high-magnification image using X-rays. However, such high-magnification scanning environments can be affected by minute vibrations of the CL device, which can generate motion artifacts in the 3D reconstructed image. Since such vibrations are irregular, geometric corrections must be performed at every scan. In this paper, we propose a geometry calibration method that can correct the geometric information of CL scans based on the image without using geometry calibration phantoms. The proposed method compares the projection and digitally reconstructed radiography images to measure the geometric error. To validate the proposed method, we used both numerical phantom images at various magnifications and images obtained from real industrial CL equipment. The experiment results confirmed that sharpness and contrast-to-noise ratio (CNR) were improved.