• Title/Summary/Keyword: 3D City model

Search Result 217, Processing Time 0.027 seconds

A Numerical Study of the 2-D Cold Flow for a Qubec City Stoker Incinerator (큐벡시 스토커 소각로 2차원 비반응 유동장 수치해석)

  • 박지영;송은영;장동순
    • Journal of Energy Engineering
    • /
    • v.2 no.3
    • /
    • pp.268-275
    • /
    • 1993
  • A series of parametric investigations are performed in order to resolve the flow characteristic of a Quebec city stoker incinerator. The parameters considered in this study are five internal configurations of the Quebec city stoker itself and its modified ones, primary air velocity, the injection velocity and angle of the secondary air, and the reduction of the stoker exit area. A control-volume based finite-difference method by Patankar together with the power-law scheme is employed for discretization. The resolution of the pressure-velocity coupling is made by the use of SIMPLEC algorithm. The standard, two equation, k-$\varepsilon$ model is incorporated for the closure of turbulence. The size of recirculation region, turbulent viscosity, the mass fraction of the secondary air and pressure drop are calculated in order to analyze the characteristics of flow field. The results are physically acceptable and discussed in detail. The flow field of the Quebec city stoker shows the strong recirculation zone together with the high turbulence intensity over the upper part of the incinerator.

  • PDF

Numerical Study on Pilot Ratio Effect of Shale-Gas in a Commercial Gas Turbine (상용급 가스터빈에서 셰일가스 파일럿비 영향에 관한 수치해석적 연구)

  • Seo, Dong Kyun;Joo, Yong-Jin;Park, Seik;Kim, Mi-yoeng;Shin, Jugon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.3
    • /
    • pp.189-195
    • /
    • 2019
  • In this work, the flow and combustion characteristics using a 3-D numerical simulation was evaluated for a shale gas fueled combustor in a commercial class gas turbine. The Standard k-e turbulence model, 2 step methane oxidation mechanism, Finite rate/Eddy dissipation reaction model, DTRM radiation model were employed and validated well at the baseline condition (Natural Gas, Pilot Ratio 0.2). Based on the validated models, the combustion characteristics of shale gas was evaluated for three pilot ratios cases. It was found that NOx concentrations for all shale gas cases were less than the that for city gas, which imply that, at the selected PRs, the condition for combustion stability is satisfied. In addition, for higher PR, whereas the average temperatures at the exit are the same, the NOx increases. It means that diffusion combustion portion increases due to the higher PR.

Modal analysis and ambient vibration measurements on Mila-Algeria cable stayed bridge

  • Kibboua, Abderrahmane;Farsi, Mohamed Naboussi;Chatelain, Jean-Luc;Guillier, Bertrand;Bechtoula, Hakim;Mehani, Youcef
    • Structural Engineering and Mechanics
    • /
    • v.29 no.2
    • /
    • pp.171-186
    • /
    • 2008
  • The seismic response analysis of an existing bridge needs a mathematical model that can be calibrated with measured dynamic characteristics. These characteristics are the periods and the associated mode shapes of vibration and the modal damping coefficients. This paper deals with the measurements and the interpretation of the results of ambient vibration tests done on a newly erected cable stayed bridge across the Oued Dib River at Mila city in Algeria. The signal analysis of ambient vibration records will permit to determine the dynamic characteristics of the bridge. On the other hand, a 3-D model of the bridge is developed in order to assess the frequencies and the associated modes of vibration. This information will be necessary in the planning of the test on the site (locations of the sensors, frequencies to be measured and the associated mode shapes of vibration). The frequencies predicted by the finite element model are compared with those measured during full-scale ambient vibration measurements of the bridge. In the same way, the modal damping coefficients obtained by the random decrement method are compared to those of similar bridges.

A Study of 3D Modeling of Compressed Urban LiDAR Data Using VRML (VRML을 이용한 도심지역 LiDAR 압축자료의 3차원 표현)

  • Jang, Young-Woon;Choi, Yun-Woong;Cho, Gi-Sung
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.19 no.2
    • /
    • pp.3-8
    • /
    • 2011
  • Recently, the demand for enterprise for service map providing and portal site services of a 3D virtual city model for public users has been expanding. Also, accuracy of the data, transfer rate and the update for the update for the lapse of time emerge are considered as more impertant factors, by providing 3D information with the web or mobile devices. With the latest technology, we have seen various 3D data through the web. With the VRML progressing actively, because it can provide a virtual display of the world and all aspects of interaction with web. It offers installation of simple plug-in without extra cost on the web. LiDAR system can obtain spatial data easily and accurately, as supprted by numerous researches and applications. However, in general, LiDAR data is obtained in the form of an irregular point cloud. So, in case of using data without converting, high processor is needed for presenting 2D forms from point data composed of 3D data and the data increase. This study expresses urban LiDAR data in 3D, 2D raster data that was applied by compressing algorithm that was used for solving the problems of large storage space and processing. For expressing 3D, algorithm that converts compressed LiDAR data into code Suited to VRML was made. Finally, urban area was expressed in 3D with expressing ground and feature separately.

Comparative Experiment to Determine the Activation Factor of Lead dioxide by Kinds in Measuring the Concentration of Sulfur oxides in the Atmosphere by $PbO_2$ Cylinder Method (사용시약별로 본 이산화연법에 의한 대기중 황산화물의 비교측정및 자동측정 성적과의 비교)

  • 최덕일
    • Journal of Environmental Health Sciences
    • /
    • v.2 no.1
    • /
    • pp.29-31
    • /
    • 1975
  • This experiment Was carried out under two points of view, from May 1st to the end of 1973. One was the comparative determination of the activation factor of Lead dioxide by kinds in measuring of Sulfur oxides concentration by $PbO_2$ cylinder method, and the other was the comparison that result with the record of auto analyzer. Five measuring sites were selected out of Seoul City. Three kinds of Lead dioxide made in Japan (B,C and D) were compared with Standard $PbO_2$ (A for use in Determination of Sulphur in the atmosphere, purity 99% up) made in British Institution, and monthly measuring was conducted at every sampling site. The recording by auto analyzer (Beckman Model 906-A $SO_2$ Analyzer) was conducted once or twice a month for 24 hours at each sampling site during the same period. And some significant results were obtained. 1. In comparative experiments to determine the activation degree of three kinds of Lead dioxide (B,C and D), the obtained correction factor of B reagent was 1.09, 1.16 in C and 1.30 in D against Standard $PbO_2$ (A). Therefore, it should be in need of standardization or clear statement about the reagents for use, in determination sulfur oxides by $PbO_2$ cylinder method. 2. Generally, the concentration of Sulfur dioxide by wilkins' convertion method from $SO_3$ showed about 20-30% higher than those by Auto analyzer.

  • PDF

Urban Flood Simulation Considering Building and Sewer Lines (건물 및 우수 배제를 고려한 시가지 범람해석)

  • Kang, Sang-Hyeok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.3B
    • /
    • pp.213-219
    • /
    • 2009
  • In densely urban areas, features such as the sewer system, buildings and river banks have an effect on flow dynamics and flood propagation, and will therefore be accounted for in the model set-up. While two-dimensional (2D) flood models of urban areas are at the forefront of current research into flood inundation mechanisms, they are however constrained by inadequate parameters of topography, and insufficient and inaccurate data. In this study, an urban flood model (overland flow, 2D urban flood flow and sewer flow) was combined and applied at Samcheok city which was damaged by inundation in 2002, in order to simulate inundation depth. The influence of buildings and pumping capacity was also analyzed to estimate the inundated depth in the study area. As a result, it was found that urban inundated depth are affected by pumping capacity directly and it increased about 20-30 cm on most of the modeled area with a building share rate of 0.2-0.6 per unit grid.

Density Predictive Model within the On-Ramp Merge Influence Areas of Urban Freeway - Based on the Beonyoungro in the Metropolitan City of Busan - (도시고속도로의 유입연결로 합류영향권내 밀도추정모형 구축에 관한 연구 -부산광역시 번영로를 대상으로 -)

  • Kim, Tae Gon;Pyo, Jong Jin;Kwon, Mi Hyun;Jo, In Kook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3D
    • /
    • pp.287-293
    • /
    • 2008
  • Density is used as the measure of effectiveness within the ramp junction influence area suggested in the KHCM 2005 in the LOS analysis of the ramp junction, and also density predictive models suggested in the KHCM 2005 is constructed based on the expressway with the speed limit of 100km/h or 110km/h in Korea. So, the density predictive models suggested in the KHCM 2005 are needed to verify if the models could be applied to the urban freeway with the speed limit of 80km/h or less, because the speed limits on most of the urban freeways in Korea are 80km/h or less. The purpose in this study is to construct and verify the appropriate density predictive model within the on-ramp merge influence area of the urban freeway by comparing with the USHCM 2000 and KHCM 2005 models.

Setting of the Operating Conditions of Stereo CCTV Cameras by Weather Condition

  • Moon, Kwang;Pyeon, Mu Wook;Lee, Soo Bong;Lee, Do Rim
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.6
    • /
    • pp.591-597
    • /
    • 2014
  • A wide variety of image application methods, such as aerial image, terrestrial image, terrestrial laser, and stereo image point are currently under investigation to develop three-dimensional 3D geospatial information. In this study, matching points, which are needed to build a 3D model, were examined under diverse weather conditions by analyzing the stereo images recorded by closed circuit television (CCTV) cameras installed in the U-City. The tests on illuminance and precipitation conditions showed that the changes in the number of matching points were very sensitively correlated with the changes in the illuminance levels. Based on the performances of the CCTV cameras used in the test, this study was able to identify the optimal values of the shutter speed and iris. As a result, compared to an automatic control mode, improved matching points may be obtained for images filmed using the data obtained through this test in relation to different weather and illuminance conditions.

Knowledge and Behavior of Visitors in the Prevention of Respiratory Tract Infections in an Emergency Service, Hospital (응급의료센터 내원객의 호흡기 감염예방에 대한 지식과 수행도)

  • Jo, Myeong-Ji;Moon, Kyoung-Ja;Lee, Eunsuk
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.25 no.3
    • /
    • pp.210-219
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the effects of emergency setting visitors' knowledge and behavior patterns in relation to prevention of respiratory tract infections. Methods: A descriptive survey was used. The participants were visitors to the emergency service in 'D' general hospital in 'D' city, and the data were collected from July 1 to September 1, 2016. The collected data were analyzed using frequency analysis, t-test, ANOVA, $Scheff{\acute{e}}$ test, Pearson correlation coefficients, and multiple regression analysis. Results: Factors influencing prevention of respiratory tract infections were visitors' education level, methods of dissemination of prevention information, and participants' knowledge with regard to preventive methods. The explanatory power was found to be 35% in the regression model. Conclusion: The findings indicate that visitors' education level, knowledge of infection prevention, and the dissemination of information regarding infection prevention by the hospital play an important role in the prevention of respiratory tract infections in emergency services in the hospital. These results highlight the need for a customized education program for prevention of respiratory tract infections in emergency settings. Programs should take into consideration the educational background of visitors, and provide them with appropriate information regarding infection prevention.

Experimental and finite element studies of special-shape arch bridge for self-balance

  • Lu, Pengzhen;Zhao, Renda;Zhang, Junping
    • Structural Engineering and Mechanics
    • /
    • v.35 no.1
    • /
    • pp.37-52
    • /
    • 2010
  • Special-shape arch bridge for self-balance (SBSSAB) in Zhongshan City is a kind of new fashioned spatial combined arch bridge composed of inclined steel arch ribs, curved steel box girder and inclined suspenders, and the mechanical behavior of the SBSSAB is particularly complicated. The SBSSAB is aesthetic in appearance, and design of the SBSSAB is artful and particular. In order to roundly investigate the mechanical behavior of the SBSSAB, 3-D finite element models for spatial member and shell were established to analyze the mechanical properties of the SBSSAB using ANSYS. Finite element analyses were conducted under several main loading cases, moreover deformation and strain values for control section of the SBSSAB under several main loading cases were proposed. To ensure the safety and rationality for optimal design of the SBSSAB and also to verify the reliability of its design and calculation theories, the 1/10 scale model tests were carried out. The measured results include the load checking calculation, lane loading and crowd load, and dead load. A good agreement is achieved between the experimental and analytical results. Both experimental and analytical results have shown that the SBSSAB is in the elastic state under the planned test loads, which indicates that the SBSSAB has an adequate load-capacity. The calibrated finite-element model that reflects the as-built conditions can be used as a baseline for health monitoring and future maintenance of the SBSSAB.