• 제목/요약/키워드: 3D Calibration

Search Result 667, Processing Time 0.03 seconds

Viewing Angle-Improved 3D Integral Imaging Display with Eye Tracking Sensor

  • Hong, Seokmin;Shin, Donghak;Lee, Joon-Jae;Lee, Byung-Gook
    • Journal of information and communication convergence engineering
    • /
    • v.12 no.4
    • /
    • pp.208-214
    • /
    • 2014
  • In this paper, in order to solve the problems of a narrow viewing angle and the flip effect in a three-dimensional (3D) integral imaging display, we propose an improved system by using an eye tracking method based on the Kinect sensor. In the proposed method, we introduce two types of calibration processes. First process is to perform the calibration between two cameras within Kinect sensor to collect specific 3D information. Second process is to use a space calibration for the coordinate conversion between the Kinect sensor and the coordinate system of the display panel. Our calibration processes can provide the improved performance of estimation for 3D position of the observer's eyes and generate elemental images in real-time speed based on the estimated position. To show the usefulness of the proposed method, we implement an integral imaging display system using the eye tracking process based on our calibration processes and carry out the preliminary experiments by measuring the viewing angle and flipping effect for the reconstructed 3D images. The experimental results reveal that the proposed method extended the viewing angles and removed the flipping images compared with the conventional system.

Simulation based Target Geometry Determination Method for Extrinsic Calibration of Multiple 2D Laser Scanning System (다중 2D 레이저 스캐너 시스템의 외부 표정요소 캘리브레이션을 위한 시뮬레이션 기반 표적 배치 결정 기법)

  • Ju, Sungha;Yoon, Sanghyun;Park, Sangyoon;Heo, Joon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.6
    • /
    • pp.443-449
    • /
    • 2018
  • Acquiring indoor point cloud, using SLAM (Simultaneous Localization and Mapping) based mobile mapping system, is an element progress for development of as-build BIM (Building Information Model) for the maintenance of the building. In this research we proposed a simulation-based target geometry determination for extrinsic calibration of multiple 2D laser scanning mobile system. Four different types of calibration sites were designed: (1) circle type; (2) rectangle type; (3) double circle type; and (4) double rectangle type. Based on the measurement values obtained from each simulated calibration site geometry, least squares solution based extrinsic calibration was derived. As a result, the rectangle type geometry is most suitable for extrinsic calibration of this system. Also, correlation values between extrinsic calibration parameters were high, and calibration results were distinct according to the calibration sites.

New Initialization method for the robust self-calibration of the camera

  • Ha, Jong-Eun;Kang, Dong-Joong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.752-757
    • /
    • 2003
  • Recently, 3D structure recovery through self-calibration of camera has been actively researched. Traditional calibration algorithm requires known 3D coordinates of the control points while self-calibration only requires the corresponding points of images, thus it has more flexibility in real application. In general, self-calibration algorithm results in the nonlinear optimization problem using constraints from the intrinsic parameters of the camera. Thus, it requires initial value for the nonlinear minimization. Traditional approaches get the initial values assuming they have the same intrinsic parameters while they are dealing with the situation where the intrinsic parameters of the camera may change. In this paper, we propose new initialization method using the minimum 2 images. Proposed method is based on the assumption that the least violation of the camera’s intrinsic parameter gives more stable initial value. Synthetic and real experiment shows this result.

  • PDF

An Easy Camera-Projector Calibration Technique for Structured Light 3-D Reconstruction (구조광 방식 3차원 복원을 위한 간편한 프로젝터-카메라 보정 기술)

  • Park, Soon-Yong;Park, Go-Gwang;Zhang, Lei
    • The KIPS Transactions:PartB
    • /
    • v.17B no.3
    • /
    • pp.215-226
    • /
    • 2010
  • The structured-light 3D reconstruction technique uses a coded-pattern to find correspondences between the camera image and the projector image. To calculate the 3D coordinates of the correspondences, it is necessary to calibrate the camera and the projector. In addition, the calibration results affect the accuracy of the 3D reconstruction. Conventional camera-projector calibration techniques commonly require either expensive hardware rigs or complex algorithm. In this paper, we propose an easy camera-projector calibration technique. The proposed technique does not need any hardware rig or complex algorithm. Thus it will enhance the efficiency of structured-light 3D reconstruction. We present two camera-projector systems to show the calibration results. Error analysis on the two systems are done based on the projection error of the camera and the projector, and 3D reconstruction of world reference points.

Measurement of 3D Shape of Fastener using Camera and Slit Laser (카메라와 슬릿 레이저를 이용한 나사 3D 형상 측정)

  • Kim, Jin Woo;Song, Tae Hun;Ha, Jong Eun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.6
    • /
    • pp.537-542
    • /
    • 2015
  • The measurement of 3D shape is important in inspecting the quality of product. In this paper, we present a 3D shape measurement system of fastener using a camera and a slit laser. Calibration structure with slits is used in the extrinsic calibration of the camera and laser. The pose of the camera and laser is computed under the same world coordinate system in the calibration structure. Reflection of laser light on the metal surface causes many difficulties in the robust detection of them on image. We overcome this difficulty by using color and dynamic programming. Motor stage is used to rotate the fastener to recover the whole 3D shape of the surface of it.

An Exact 3D Data Extraction Algorithm For Active Range Sensor using Laser Slit (레이저 슬릿을 사용하는 능동거리 센서의 정확한 3D 데이터 추출 알고리즘)

  • Cha, Y.Y.;Gweon, D.G.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.8
    • /
    • pp.73-85
    • /
    • 1995
  • The sensor system to measure the distance precisely from the center of the sensor system to the obstacle is needed to recognize the surrounding environments, and the sensor system is to be calibrated thoroughly to get the range information exactly. This study covers the calibration of the active range sensor which consists of camera and laser slit emitting device, and provides the equations to get the 3D range data. This can be possible by obtaining the extrinsic parameters of laser slit emitting device through image processing the slits measured during the constant distance intervals and the intrinsic parameters from the calibration of camera. The 3D range data equation derived from the simple geometric assumptions is proved to be applicable to the general cases using the calibration parameters. Also the exact 3D range data were obtained to the object from the real experiment.

  • PDF

A Study on Vision-based Calibration Method for Bin Picking Robots for Semiconductor Automation (반도체 자동화를 위한 빈피킹 로봇의 비전 기반 캘리브레이션 방법에 관한 연구)

  • Kyo Mun Ku;Ki Hyun Kim;Hyo Yung Kim;Jae Hong Shim
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.1
    • /
    • pp.72-77
    • /
    • 2023
  • In many manufacturing settings, including the semiconductor industry, products are completed by producing and assembling various components. Sorting out from randomly mixed parts and classification operations takes a lot of time and labor. Recently, many efforts have been made to select and assemble correct parts from mixed parts using robots. Automating the sorting and classification of randomly mixed components is difficult since various objects and the positions and attitudes of robots and cameras in 3D space need to be known. Previously, only objects in specific positions were grasped by robots or people sorting items directly. To enable robots to pick up random objects in 3D space, bin picking technology is required. To realize bin picking technology, it is essential to understand the coordinate system information between the robot, the grasping target object, and the camera. Calibration work to understand the coordinate system information between them is necessary to grasp the object recognized by the camera. It is difficult to restore the depth value of 2D images when 3D restoration is performed, which is necessary for bin picking technology. In this paper, we propose to use depth information of RGB-D camera for Z value in rotation and movement conversion used in calibration. Proceed with camera calibration for accurate coordinate system conversion of objects in 2D images, and proceed with calibration of robot and camera. We proved the effectiveness of the proposed method through accuracy evaluations for camera calibration and calibration between robots and cameras.

  • PDF

A Study m Camera Calibration Using Artificial Neural Network (신경망을 이용한 카메라 보정에 관한 연구)

  • Jeon, Kyong-Pil;Woo, Dong-Min;Park, Dong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1248-1250
    • /
    • 1996
  • The objective of camera calibration is to obtain the correlation between camera image coordinate and 3-D real world coordinate. Most calibration methods are based on the camera model which consists of physical parameters of the camera like position, orientation, focal length, etc and in this case camera calibration means the process of computing those parameters. In this research, we suggest a new approach which must be very efficient because the artificial neural network(ANN) model implicitly contains all the physical parameters, some of which are very difficult to be estimated by the existing calibration methods. Implicit camera calibration which means the process of calibrating a camera without explicitly computing its physical parameters can be used for both 3-D measurement and generation of image coordinates. As training each calibration points having different height, we can find the perspective projection point. The point can be used for reconstruction 3-D real world coordinate having arbitrary height and image coordinate of arbitrary 3-D real world coordinate. Experimental comparison of our method with well-known Tsai's 2 stage method is made to verify the effectiveness of the proposed method.

  • PDF

Evaluation of Robot Calibration Performance based on a Three Dimensional Small Displacement Measuring Sensor (3차원 미소변위센서 기반 로봇 캘리브레이션 성능 검토)

  • Nguyen, Hoai-Nhan;Kang, Hee-Jun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.12
    • /
    • pp.1267-1271
    • /
    • 2014
  • There have been many autonomous robot calibration methods which form closed loop structures through the various attached sensors and mechanical fixtures. Single point calibration among them has been used for on-site calibration due to its convenience of implementation. The robot can reach a single point with infinitely many configurations so that single point calibration algorithm can be set up and easily implemented relative to the other methods. However, it is not still easy to drive the robots' sharp edge to its corresponding edge of the fixture. This is error-prone process. In this paper, we propose a 3 dimensional small displacement measuring sensor and a robot calibration algorithm based on this sensor. This method relieves the difficulty of matching two edges in the single point calibration and improves the resulting robot accuracy. Simulated study is carried out on a Hyundai HA06 robot to show the effectiveness of the proposed method over the single point calibration. And also, the resulting robot accuracy is compared with that from 3D laser tracker based calibration to show the dependency of robot accuracy on range of the workspace where the measurement data are collected.

The Structured Grid Pattern Calibration Based On Triangulation Method (삼각법기반 구조화된 격자 패턴 캘리브레이션)

  • 주기세
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.5
    • /
    • pp.1074-1079
    • /
    • 2004
  • So far, many sensors such as a structured grid pattern generator, a laser, and CCD camera to obtain 3D information have been used, but most of algorithms for a calibration are inefficient since a huge memory and experiment time are required. In this paper, the calibration algorithm of a structured grid pattern based on triangulation method is introduced to calculate 3D information in the real world. The beams generated from structured grid pattern generator established horizontally with the CCD camera are projected on the calibration plat. A CCD camera measures the intersection plane of a projected beam and an object plane. The 3D information is calculated using measured and calibration datum. This proposed method in this paper has advantages such as a memory saving and an efficient experimental time since the 3D information is obtained simply the triangulation method.