• Title/Summary/Keyword: 3D CT angiography

Search Result 54, Processing Time 0.024 seconds

The Evaluation of the Radiation Dose and Image Quality Through the Change of the Tube Voltage in Cerebral CT Angiography (전산화단층촬영장치를 이용한 뇌 혈관조영 검사에서 관전압 변화에 따른 방사선량과 영상의 질 평가)

  • LEE, Ji-Won;Jung, Kang-Kyo;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.121-126
    • /
    • 2015
  • To image diagnosis in neurovascular diseases using Multi-Detector Computed Tomography(MDCT), injected the same contrast material when inspecting Brain Computed Tomography Angiography(BCTA) to examine radiation dose and Image quality on changing Cerebral Artery CT number by tube voltage. Executed an examination with same condition[Beam Collimation $128{\times}0.6mm$, Pitch 0.6, Rotation Time 0.5s, Slice Thickness 5.0mm, Increment 5.0mm, Delay Time 3.0sec, Care Dose 4D(Demension ; D)] except for tube voltage on 50 call patients for BCTA and divided them into two groups (25 people for a group, group A: 80, group B: 120kVp). From all the acquired images, set a ROI(Region of Interest) on four spots such as left cerebral artery, right cerebral artery, posterior cerebral artery and cerebral parenchyma to compare quantitative evaluation, qualitative evaluation and effective dose after measuring CT number value from Picture Archiving Communications System(PACS). Evaluating images with CT number acquired from BCTA examination, images with 80 kVp was 18% higher in Signal to Noise Ratio and 19% in Contrast to Noise Ratio than those with 120 kVp. It was seen that expose dose was decreased by over 50% with tube voltage 80 kVp than with 120 kVp. Group A (25 patients) was examination with tube voltage 80kVp while group B with 120 kVp to examine radiation dose and Image quality. It is considered effective to inspect with lower tube voltage than with conventional high kVp, which can reduce radiation dose without any affect on diagnosis.

A Study on the Optimum Amount of Contrast Media in Brain Angiography (뇌 혈관검사 시 적정 조영제량에 관한 연구)

  • Kim, Gyoo-Hyung;Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.123-128
    • /
    • 2018
  • Recently, the use of contrast agents has been increasing as a broader range of tests and dynamic tests have become common due to the development of equipment and imaging techniques such as Multi-Detector CT. However, the side effects of using contrast agents have been reduced by the development of non-ionic contrast agents, but they are still occurring often. The purpose of this study was to propose a method to minimize the side effect of contrast agent by using the amount of contrast agent injected to the brain angiography test to suppress excessive use of contrast agent and analyze the amount of contrast agent. Patients who were prescribed Brain Angiography due to cerebrovascular disease, According to the results of the comparison of the results obtained by dividing into 4 groups of 10ml each according to the amount of contrast medium injected with contrast agent according to the BMI of the patient, BA and SNR were not different between groups, and even if the amount of contrast injection was reduced, there was no problem in the evaluation of CT angiography through 3D reconstruction. This result shows that even if the contrast medium is injected into the blood vessels of the patient first and then the contrast medium is used as the physiological saline solution, the contrast medium is reduced by 40% it can be expected to minimize.

Evaluation of the Cause of Internal Jugular Vein Obstruction on Head and Neck Contrast Enhanced 3D MR Angiography Using Contrast Enhanced Computed Tomography (조영증강 전산화단층촬영술을 이용한 두경부 조영증강 삼차원 자기공명혈관촬영술에서 내경정맥 폐쇄의 원인 평가)

  • Gweon, Hye-Mi;Chung, Tae-Sub;Suh, Sang-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.41-47
    • /
    • 2011
  • Purpose : To evaluate the cause of internal jugular vein (IJV) obstruction on contrast enhanced 3D MR angiography (CE-MRA) using contrast enhanced computed tomography (CE-CT). Materials and Methods : A total number of 30 patients were enrolled, who underwent both head and neck CE-MRA and CE-CT from 2005 to 2008. We defined obstruction group which had IJV obstruction and control group which had no IJV obstruction on CE-MRA. The following parameters were measured from axial images of CE-CT: 1) diameter of IJV; 2) distance between the styloid process and ipsilateral lateral mass of the atlas; 3) maximum area of lateral mass of the atlas. Each parameter was compared between obstruction group and control group. Results : The diameter of IJV and distance between the styloid process and lateral mass of the atlas at IJV obstruction side in obstruction group were $1.6{\pm}1.0\;mm$ and $4.1{\pm}2.1\;mm$ respectively, which resulted in statistical significance (p<0.01). The maximum area of lateral mass of the atlas at IJV obstruction side in obstruction group was $103.4{\pm}25.3\;mm^2$ which is significantly larger than in control group (p<0.05). Conclusion : We found that the cause of IJV obstruction on CE-MRA could be narrow space between the styloid process and the lateral mass of the atlas, which was related with asymmetric larger area of lateral mass of atlas.

Role of 'Spot Sign' on CT Angiography to Predict Hematoma Expansion in Spontaneous Intracerebral Hemorrhage

  • Park, Soo-Yong;Kong, Min-Ho;Kim, Jung-Hee;Kang, Dong-Soo;Song, Kwan-Young;Huh, Seung-Kon
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.5
    • /
    • pp.399-405
    • /
    • 2010
  • Objective : Patients with spontaneous intracerebral hemorrhage (ICH) presenting within 24 hours of symptom onset are known to be increased risk of hematoma expansion which is closely correlated with morbidity and mortality. We investigated whether tiny enhancing foci ('Spot sign') on axial view of 3-dimensional computed tomography angiography (3D-CTA) source images can predict subsequent hematoma expansion in spontaneous ICH. Methods : During a 2-year period (March 2007-March 2009), we prospectively evaluated 3D-CTA of 110 patients with spontaneous ICH. Based on source images of 3D-CTA, patients were classified according to presence or absence of 'Spot sign'; 'Spot sign' (+) group, 'Spot sign' (-) group. Radiological factors and clinical outcomes were compared between two groups. Results : Hematoma expansion occurred in 16 patients (15%). Mean Glasgow Coma Scale (GCS) score of patients with hematoma expansion was significantly different compared to score of patients without hematoma expansion (5 vs. 9, P < 0.001). Nineteen patients (16%) of 110 ICH patients demonstrated 'spot sign' on 3D-CTA. Among the 'spot sign' (+) group, 53% of patients developed hematoma expansion. Conversely 7% of patients without 'spot sign' demonstrated the hematoma expansion (p < 0.001). Initial volume and location of hematoma were significantly not associated with hematoma expansion except shape of hematoma. Conclusion : Our study showed that patients with hematoma expansion of spontaneous ICH had significant clinical deterioration. And the fact that 'spot sign' (+) group have higher risk of hematoma expansion suggests the presence of 'spot sign' on source images of 3D-CTA can give a clue to predict hematoma expansion in spontaneous ICH.

Dynamic Computed Tomography based on Spatio-temporal Analysis in Acute Stroke: Preliminary Study (급성 뇌졸중 환자의 시공간 분석 기법을 이용한 동적 전산화 단층 검사: 예비 연구)

  • Park, Ha-Young;Pyeon, Do-Yeong;Kim, Da-Hye;Jung, Young-jin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.543-547
    • /
    • 2016
  • Acute stroke is a one of common disease that require fast diagnosis and treatment to save patients life. however, the acute stroke may cause lifelong disability due to brain damage with no prompt surgical procedure. In order to diagnose the Stroke, brain perfusion CT examination and possible rapid implementation of 3D angiography has been widely used. However, a low-dose technique should be applied for the examination since a lot of radiation exposure to the patient may cause secondary damage for the patients. Therefore, the degradation of the measured CT images may interferes with a clinical check in that blood vessel shapes on the CT image are significantly affected by gaussian noise. In this study, we employed the spatio-temporal technique to analyze dynamic (brain perfusion) CT data to improve an image quality for successful clinical diagnosis. As a results, proposed technique could remove gaussian noise successfully, demonstrated a possibility of new image segmentation technique for CT angiography. Qualitative evaluation was conducted by skilled radiological technologists, indicated significant quality improvement of dynamic CT images. the proposed technique will be useful tools as a clinical application for brain perfusion CT examination.

Is Computerized Tomography Angiographic Surveillance Valuable for Prevention of Tracheoinnominate Artery Fistula, a Life-Threatening Complication after Tracheostomy?

  • Sung, Jae-Hoon;Kim, Il-Sup;Yang, Seung-Ho;Hong, Jae-Taek;Son, Byung-Chul;Lee, Sang-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.2
    • /
    • pp.107-111
    • /
    • 2011
  • Objective : The aim of this study was to evaluate the utility of volume-rendered helical computerized tomography (CT) angiography focusing tracheostomy tube and innominate artery for prevention of tracheoinnominate artery fistula. Methods : The authors retrospectively analyzed 22 patients with tracheostomy who had checked CT angiography. To evaluate the relationship between tracheostomy tube and innominate artery, we divided into three categories. First proximal tube position based on cervical vertebra, named "tracheostomy tube departure level (TTDL)". Second, distal tube position and course of innominate artery, named "tracheostomy tube-innominate artery configuration (TTIC)". Third, the gap between the tube and innominate artery, named "tracheostomy tube to innominate artery gap (TTIG)". The TTDL/TTIC and TTIG are based on 3-dimensional (3D) reconstruction around tracheostomy and enhanced axial slices of upper chest, respectively. Results : First, mean TTDL was $6.8{\pm}0.6$. Five cases (23%) were lower than C7 vertebra. Second, TTIC were remote to innominate artery (2 cases; 9.1 %), matched with it (14 cases; 63.6%) or crossed it (6 cases; 27.3%). Only 9% of cases were definitely free from innominate artery injury. Third, average TTIG was $4.3{\pm}4.6$ mm. Surprisingly, in 6 cases (27.3%), innominate artery, trachea wall and tracheostomy tube were tightly attached all together, thus have much higher probability of erosion. Conclusion : If low TTDL, match or crossing type TTIC with reverse-L shaped innominate artery, small trachea and thin TTIG are accompanied all together, we may seriously consider early plugging and tube removal.

A Rare Case of Spontaneous True Aneurysm of the Occipital Artery

  • Kim, Hyung-Seok;Son, Byung-Chul;Lee, Sang-Won;Kim, Il-Sup
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.4
    • /
    • pp.310-312
    • /
    • 2010
  • A 51-year-old man presented with a pulsatile scalp mass over the right occipital region, which had increased in size over the previous 1 month. He had no previous history of head trauma. Three-dimensional computed tomography (3D-CT) angiography of the brain revealed a $3.0{\times}1.5\;cm$ occipital artery aneurysm arising from the occipital artery. The occipital artery aneurysm was removed following the ligation of the proximal and distal portion of the occipital artery aneurysm. The histological diagnosis was true aneurysm. To the best of our knowledge, this is the first reported case in the literature.

Ruptured mirror DACA aneurysm: A rare case report and review of literature

  • Deepak Kumar Singh;Prevesh Kumar Sharma;Arun Kumar Singh;Vipin Kumar Chand
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.3
    • /
    • pp.340-346
    • /
    • 2023
  • Bilateral distal anterior cerebral artery (DACA) aneurysms also called "kissing aneurysms" or "mirror aneurysm" are extremely rare, accounting for only 0.2% of all intracranial aneurysms. There have only been a few examples of mirror DACA aneurysms reported in the literature. Here, we report a rare case of mirror DACA aneurysm in a middle aged female with its successful clipping. Patient was admitted with severe headache and altered sensorium. Computed tomography (CT) head was suggestive of anterior inter-hemispheric hematoma. Digital subtraction angiography (DSA) was done which was suggestive of two distal anterior cerebral artery aneurysms located at same anatomical position. It was treated through microsurgical clipping. Mirror image DACA aneurysms are rare occurrence. All patients with ruptured DACA aneurysms should have angiography with 3D reconstruction studies. This aids in determining the aneurysm's morphology and planning treatment accordingly.

Development of 3-D Radiosurgery Planning System Using IBM Personal Computer (IBM Personal Computer를 이용한 3차원적 뇌정위 방사선 수술계획 시스템의 개발)

  • Suh Tae-Suk;Suh Doug-Young;Park Charn Il;Ha Sung Whan;Kang Wee Saing;Park Sung Hun;Yoon Sei Chul
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.167-174
    • /
    • 1993
  • Recently, stereotactic radiosurgery plan is required with the information of 3-D image and dose distribution. A project has been doing if developing LINAC based stereotactic radiosurgery since April 1991. The purpose of this research is to develop 3-D radiosurgery planning system using personal computer. The procedure of this research is based on two steps. The first step is to develop 3-D localization system, which input the image information of the patient, coordinate transformation, the position and shape of target, and patient contour into computer system using CT image and stereotactic frame. The second step is to develop 3-D dose planning system, which compute dose distribution on image plane, display on high resolution monitor both isodose distribution and patient image simultaneously and develop menu-driven planning system. This prototype of radiosurgery planning system was applied recently for several clinical cases. It was shown that our planning system is fast, accurate and efficient while making it possible to handle various kinds of image modalities such as angiography, CT and MRI. It makes it possible to develop general 3-D planning system using beam's eye view or CT simulation in radiation therapy in future.

  • PDF

Theoretical Determination of Geometrical Structures of the Nitric Oxide Dimer, (NO)₂

  • 박종근;선호성
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.12
    • /
    • pp.1399-1408
    • /
    • 1999
  • Geometrical structures for the dimerization of (NO)₂ from (NO + NO) have been calculated using ab initio Har-tree-Fock (SCF), second-order Møller-Plesset perturbation (MP2), and coupled cluster with the single, double, and triple substitution [CCSD(T)] methods with a triple zeta plus polarization (TZP) basis set including diffuse Rydberg basis functions. The structure of (NO)₂ can be described by two interactions (N…N, N…O). One is the ONNO structure with an (N…N) interaction. In this structure, acyclic cis-ONNO with $C_{2v}$-symmetry, acyclic trans-ONNO with $C_{2h}$, and cyclic ONNO with trapezoidal structure ($C_{2v}$) are optimized at the MP2 level. The other structure is the ONON structure with an (N…O) interaction. In the structure, acyclic cis-ONON with Cs$^{-symmetry}$ and cyclic ONON of the rectangular ($C_{2h}$), square $(D_{2h})$, rhombic $(D_{2h})$, and parallelogramic $(D_{2h})$ geometries are also optimized. It is found that acyclic cis-ONNO (¹A₁) is the most stable structure and cyclic ONNO (³A₁) is the least stable. Acyclic trans-ONNO (³A₁) with an (N…N) interaction, acyclic trans-ONON and bicyclic ONON $(C_{2v})$ with (N…O) interaction, and acyclic cis- and trans-NOON with an (O…O) interaction can not be optimized at the MP2 level. Particularly, acyclic trans-ONNO with $C_{2h}$-symmetry can not be optimized at the CCSD(T) level. Meanwhile, acyclic NNOO (¹A₁, $C_s)$ and trianglic NNOO (¹A₁,$C_{2v})$ formed by the (O…N) interaction between O₂ and N₂ are optimized at the MP2 level. The binding energies and the relative energy gaps among the isomers are found to be relatively small./sec. Spiral CT scans during the arterial phase were obtained 35 seconds after the injection of contrast medium. CT findings of 78 lesions less than 4cm in diameter were correlated with angiographic findings. Results : The attenuation of lesions was high(n = 69), iso(n = 5), and low(n = 4) compared with liver parenchyma during the arterial phase of spiral CT. In lesions with high-, iso-, and low-attenuation during the arterial phase of spiral CT, hypervascularity on angiograms was found in 63 of 69(91.3%), three of five(60%), and three of four lesions(75%), respectively. Six lesions with high-attenuation on the arterial phase of spiral CT were not seen on angiography. Two iso-attenuated and one low-attenuated lesion were hypovascular on angiograms. Conclusion : The results of this study suggest that with some exceptions there was good correlation between the arterial phase of spiral CT and angiography.