• 제목/요약/키워드: 3D CT angiography

검색결과 53건 처리시간 0.029초

자발성 뇌지주막하 출혈 환자에서 뇌동맥류 검출에 대한 고식적 혈관조영술과 3차원 전산화 단층 혈관조영술의 비교 (Detection of Aneurysms in Patients with Spontaneous Subarachnoid Hemorrhage : A Comparison of Three-dimensional Computed Tomographic Angiography and Conventional Angiography)

  • 이경수;강창구;허륭;이상훈;정의화
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권6호
    • /
    • pp.711-716
    • /
    • 2001
  • Objectives : Three-dimensional computed tomographic angiography(3D-CTA) is recently developed diagnostic imaging modality. We have studied this noninvasive method for possible role in replacing conventional angiography( CA) in the detection of aneurysms of the circle of Willis in patients with subarachnoid hemorrahge(SAH). Methods : We studied retrospectively, the 100 patients with SAH or unruptured aneurysms admitted to our hospital from October 1997 to December 1998. Among there, 85 patients underwent CTA, 82 patients underwent CA and 67 patients underwent both of CTA and CA. 3D-CTA was obtained using maximum intensity projection(MIP) and shaded-surface display(SSD) reconstruction. Results : Total 107 aneurysms were detected in 92 patients, and 64 aneurysms were detected in 67 patients underwent both CTA and CA. In five cases of those 67 cases, aneurysms were detected by CA but not by 3D-CTA. The detection rate of aneurysms(91.8%) and the detection rate of parent artery in cases of anterior communicating artery aneurysms(86.9%) with total 3D-CTA were relatively compatible with that of CA. But 3D-CTA was not enough in detection of posterior communicating artery aneurysms, internal carotid artery aneurysms as well as small sized aneurysm(<3mm). Conclusion : We consider CTA is valuable in as a screening test for cerebral aneurysm and follow-up test. And it is also valuable in early surgery for patients with aneurysmal rebleeding because of simple, quick, non-invasive method.

  • PDF

CT Angiography 영상에서 대동맥 추출을 위한 혈관 분할 알고리즘 성능 평가 (Performance evaluation of vessel extraction algorithm applied to Aortic root segmentation in CT Angiography)

  • 김태형;황영상;신기영
    • 한국정보전자통신기술학회논문지
    • /
    • 제9권2호
    • /
    • pp.196-204
    • /
    • 2016
  • 세계보건기구협회에의 통계에 따르면 심장 혈관 질환의 발병률이 가장 높은 것으로 알려져 있다. CTA영상을 사용하여 관상동맥 및 대동맥 질환을 치료 및 검사할 수 있다. 혈관을 3차원으로 복원하는 과정이 의사의 숙련도에 따라 결과가 상이하며 복원 시간이 길다는 단점이 있으며 이를 극복하고자 자동으로 정확한 혈관을 추출하는 연구들이 진행되어 왔다. 본 논문에서는 자동 및 반자동 분할 기법인 Region Competition, Geodesic Active Contour(GAC), Multi-atlas based segmentation, Active Shape Model(ASM) 알고리즘을 CTA영상에 적용하여 대동맥 기부를 추출하였으며 하우스도르프 거리, 볼륨, 영상처리속도, 사용자 관여 여부, 그리고 관상동맥 심문 검출률을 비교 및 분석하였다. 추출된 3차원 대동맥 모델 중 가장 높은 정확도를 나타낸 알고리즘은 GAC인 반면 사용자 관여가 가장 높았기 때문에 실제 시술에 적용하기 위해서는 자동 분할 알고리즘 개선이 필요하다

3차원 혈관 모델에서 협착 및 팽창 영역 탐색 방안 (Detecting Regions of Stenosis and Aneurysm in a 3D Blood Vessel Model)

  • 박상진;김재성;박형준
    • 한국산학기술학회논문지
    • /
    • 제19권1호
    • /
    • pp.113-120
    • /
    • 2018
  • 혈관 질환 검사는 일반적으로 혈관 조영술(angiography)과 CT 혈관 조영술(CT angiography) 등을 통해 이루어지며, 대부분 검사자의 육안을 통한 주관적 판단에 의존하여 진단이 이루어진다. 본 논문에서는 의료영상으로부터 재구성된 3차원 혈관 내벽 모델로부터 대표적 혈관질환에 해당하는 협착과 팽창 질환 의심 영역을 탐색하는 방안을 제안한다. 먼저, 의료영상에서 재구성된 3차원 혈관 내벽 모델로부터 혈관에 대한 골격 곡선(curve skeletons)과 외곽선(contours)을 생성하고, 생성된 골격 곡선을 가지 단위로 분할한 후, 가지에 속하는 각 노드에 대한 외곽선의 면적을 계산한다. 그런 다음, 계산된 외곽선들의 면적에 대해 평균 면적 및 최대/최소 면적, 그리고 인접 노드들 간의 외곽선 면적 차이를 고려하여 협착 및 팽창 질환의심 영역에 해당하는 노드들을 탐색한다. 다음으로 탐색된 의심 영역들을 적절하게 시각화함으로써 혈관질환의 진단을 지원한다. 제안된 방안을 구현하여 몇 가지 3D 인체 혈관모델에 적용한 결과 질환 의심 영역이 잘 찾아짐을 확인하였다. 이를 통해 제안된 방안의 유용성을 보인다.

심근관류 SPECT와 64채널 전산화 단층혈관 촬영 사진 융합으로 증명된 radius intermedius 협착에 의한 심근관류 저하 (Radius Intermedius Stenosis Induced Myocardial Perfusion Defect: Provened by the Fusion Images of Myocardial Perfusion SPECT and 64 Channel CTA)

  • 공은정;조인호;천경아;원규장;이형우;박종선
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권1호
    • /
    • pp.77-78
    • /
    • 2008
  • A 71-year-old woman was assigned to our department for Tc-99m myocardial perfusion SPECT(MPS) and coronary CT angiography. She admitted for substernal pain, via the ER, 2 days ago. The heart was scanned after intravenous injection of 925 MBq of $^{99m}Tc$-sestamibi adenosine-induced stress SPECT using dual head gamma camera (Hawkeye, GE healthcare. USA). The MPS shows decreased tracer uptake in the apical & mid area of anterior & lateral wall and mid & basal inferior wall. Coronary CT angiograph was obtained using Discovery VCT (GE healthcare). 3D angiography portrayed significant stenosis of ramus intermedius(RI) and posterolateral branch of right coronary artery(PLB) with fibrocalcified plaque. Two images were fused using Cardiac IQ fusion softwear package (Advantage workstation 4.4, GE healthcare) The fusion images explain the perfusion defect of anterior, lateral and inferior wall is due to stenosis of the RI and PLB. And 3 days later, coronary angiography was done and revealed the marked stenosis of RI and PLB. Then balloon angioplasty and stent was instituted in RI. Cardiac SPECT/CT fusion imaging provides additional information about hemodynamic relevance and facilitates lesion interpretation by allowing exact allocation of perfusion defects to its subtending coronary artery.

CT characteristics of normal canine pulmonary arteries and evaluation of optimal contrast delivery methods in CT pulmonary angiography

  • Jung, Joohyun;Chang, Jinhwa;Yoon, Junghee;Choi, Mincheol
    • 대한수의학회지
    • /
    • 제47권2호
    • /
    • pp.247-254
    • /
    • 2007
  • This study was performed to identify the normal anatomic orientation of pulmonary arteries and to obtain the normal baseline parameters and the optimal contrast material delivery methods of computed tomographic pulmonary angiography (CTPA) on normal beagle dogs. Based on the contrast injection flow rate, the contrast volume, and the administration methods, the experimental groups were divided into 4 groups such as group 1 : 2 ml/s, 3 ml/kg, and monophasic administration; group 2 : 5 ml/s, 3 ml/kg, and monophasic administration; group 3 : 5 ml/s, 4 ml/kg, and monophasic administration; group 4 : 5 ml/s and 2 ml/kg in first phase, 0.3 ml/s and 2 ml/kg in second phase, as biphasic administration. Normal anatomic orientation of pulmonary arteries in CTPA was evaluated through reformatted and 3D images after retro-reconstruction. Normal parameters for great arteries and peripheral pulmonary arteries were obtained on the factor of basement hounsfield unit (HU) values, contrast enhanced HU values, delay time, and peak time. And the optimal contrast delivery methods were evaluated on the factor of contrast enhanced HU values, image quality, and artifact. The monophasic administration with 5 ml/s contrast injection flow rate and 3 ml/kg contrast volume was optimal in canine CTPA.

3차원 관상동맥의 위상적인 형상분석을 위한 골격 추출 (Skeleton Extraction of 3D Coronary Artery for Topological Shape Analysis)

  • 이재진;김정식;최수미
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2005년도 가을 학술발표논문집 Vol.32 No.2 (1)
    • /
    • pp.700-702
    • /
    • 2005
  • 3차원 관상동맥처럼 위상 구조가 중요한 객체의 형상을 분석하기 위해서는 혈관의 분기점, 극단점, 혈관의 계층적 구조 관계 등의 정보를 함축적으로 표현할 수 있는 골격 추출이 매우 중요하다 본 논문에서는 3차원 CT 혈관조영술(3D CT Angiography)로 촬영된 영상으로부터 관상동맥의 3차원 골격을 추출하는 방법을 개발하였다. 먼저, CT 혈관조영술부터 획득한 슬라이스 이미지로부터 3차원 조작 및 수술 시뮬레이션 등을 위하여 혈관의 3차원 표면에 대한 메쉬 모델을 생성한다. 생성된 메쉬 모델이 임의로 변형된 후에도 자동으로 골격을 쉽게 추출할 수 있도록 메쉬 모델을 복셀화하는 단계를 거친다. 이렇게 얻어진 복셀모델로부터 유클리디언 거리 맵을 구성하여 discrete medial surface (DMS)을 생성하고 최종적으로 골격을 추출하게 된다. 이렇게 추출된 3차원 골격은 관상동맥 수술 시뮬레이션 등에서 다양한 형상 분석에 유용하게 사용될 수 있다.

  • PDF

Role of Three-dimensional Computed Tomography Angiography in the Follow-up of Patients with Aneurysm Clips

  • Park, Seong-Hyun;Park, Jae-Chan;Hwang, Jeong-Hyun;Hwang, Sung-Kyoo;Hamm, In-Suk
    • Journal of Korean Neurosurgical Society
    • /
    • 제39권6호
    • /
    • pp.427-431
    • /
    • 2006
  • Objective : The purpose of this study is to assess the usefulness of three-dimensional computed tomography angiography [3D-CTA] as a postoperative follow-up examination after intracranial aneurysms have been clipped. Methods : Between January 2002 and June 2005, 522 consecutive patients received treatment for intracranial aneurysms. A retrospective analysis of 310 patients with postoperative 3D-CTAs was performed to evaluate aneurysmal remnants and de novo aneurysms. This study was conducted in 271 patients with at least immediate and 6-month routine 3D-CT As for postoperative clipped aneurysm and 39 patients with 3D-CTAs for clipped aneurysm before 2002 when there was no 3D-CTA in our hospital. Results : Eight patients had abnormal CT angiographic findings. Aneurysm remnants were revealed in 4 patients and de novo aneurysms were discovered in 5 patients. Two patients were found at the postoperative 6-month 3D-CTA performed routinely. In 1 patient, the aneurysm was demonstrated on the way to the examination of syncope. In 2 patients, the author recommended 3D-CTA although there was no symptom because the patients had visited our institute long time ago [5.1, 4.5 years]. Of the 8 patients, 2 remnants and 1 de novo aneurysm were treated by endovascular treatment. Three de novo aneurysms at the middle cerebral artery and 1 pericallosal artery aneurysm were treated by direct clipping because these aneurysms were not suitable for the endovascular treatment in point of anatomical configuration. One patient with both remnant and de novo aneurysm was treated conservatively. Conclusion : 3D-CTA is an available, non-invasive diagnostic tool for the postoperative follow-up examination of aneurysmal state in patients after clipping.

전산화단층촬영조영술에서 화질 최적화를 위한 딥러닝 기반 및 하이브리드 반복 재구성의 특성분석 (Characterization of Deep Learning-Based and Hybrid Iterative Reconstruction for Image Quality Optimization at Computer Tomography Angiography)

  • 전필현;이창래
    • 한국방사선학회논문지
    • /
    • 제17권1호
    • /
    • pp.1-9
    • /
    • 2023
  • 전산화단층촬영조영술(computer tomography angiography, CTA)의 최적 화질을 위한 서로 다른 요오드 농도와 스캔 매개변수를 적용하여 필터 보정 역투영 (filtered back projection, FBP), 혼합형 반복재구성 (hybrid-iterative reconstruction, hybrid-IR) 및 딥러닝 재구성 (deep learning reconstruction, DLR)의 화질적 특성을 정량적으로 평가하였다. 320행 검출기 CT 스캐너에서 지름 19 cm의 원통형 물 팬텀 가장자리에 있는 다양한 요오드 농도 (1.2, 2.9, 4.9, 6.9, 10.4, 14.3, 18.4 및 25.9 mg/mL)의 팬텀을 스캔하였다. 각각의 재구성 기술을 사용하여 획득한 데이터는 노이즈 (noise), 변동 계수 (coefficient of variation, COV) 및 평균 제곱근 오차 (root mean square error, RMSE)을 통해 영상을 분석하였다. 요오드의 농도가 증가할수록 CT number 값은 증가하였지만 노이즈 변화는 특별한 특성을 보이지 않았다. 다양한 관전류 및 관전압에서 FBP, adaptive iterative dose reduction (AIDR) 3D 및 advanced intelligent clear-IQ engine (AiCE)에 대해 요오드 농도를 증가할수록 COV는 감소하였고 요오드 농도가 낮을 때는 재구성 기술 간의 COV 차이가 다소 발생하였지만, 요오드 농도가 높아짐에 따라 그 차이는 미약한 결과를 보였다. 또한, AiCE에서는 요오드 농도가 높아질수록 RMSE는 감소하지만 특정한 농도 (4.9 mg/mL) 이후에는 RMSE가 오히려 증가 되는 특성을 보여주었다. 따라서 최적의 CTA 영상 획득을 위해 재구성 기술에 따른 요오드 농도의 변화 및 다양한 관전류 및 관전압의 스캔 매개변수의 특성을 고려하여 환자 스캔을 해야 할 것이다.

쇄골하동맥 혈전증에서의 MDCT 혈관조영술의 3D 영상 (MDCT Angiography of the Subclavian Artery Thrombosis of the 3D Findings)

  • 권대철
    • 한국방사선학회논문지
    • /
    • 제12권7호
    • /
    • pp.813-819
    • /
    • 2018
  • MDCT의 3D 유용성을 입증하기 위해 쇄골하 혈전증을 수반한 73세 남자 환자를 대상으로 MIP, 볼륨렌더링, MPR의 3D 영상을 획득하여 쇄골하동맥의 혈전증을 명확하게 탐지하고 위치를 확인하여 임상에서 기초자료를 제공하여 환자의 진단 및 치료에 적용하고자한다. 스캔 데이터를 3차원 CT영상인 MIP, 볼륨렌더링, curve multiplanar reformation (MPR), virtual endoscopy 영상을 획득하였다. CT검사 환자의 데이터를 3D 프로그램으로 전송한 영상에서 3D 프로그램에서 측정한 상행대동맥은 364.28 HU, 좌총경동맥 413.77 HU, 좌쇄골하동맥 15.72 HU로 낮게 산출되었다. MIP coronal 영상으로 좌측의 쇄골하동맥의 혈전으로 폐쇄를 정확하게 보여주고 있다. 볼륨렌더링 3차원 영상으로 투과도 100%, 87-1265 HU를 적용하여 쇄골하동맥과 뼈를 동시에 묘출하고 있으며, 좌측 쇄골하동맥의 폐쇄 영상을 선명하게 보여주었으며 coronal curved MPR 및 sagittal curved MPR 영상으로 혈전의 의한 쇄골하동맥의 폐쇄를 3D 영상 처리 기능을 이용하여 정확하게 묘출하고 있다. 혈전에 의한 쇄골하동맥 폐쇄 증상 환자를 MDCT로 스캔하여 3D 영상 기법을 응용하여 쇄골하동맥의 폐쇄를 확인할 수 있어 임상에서 3D 기법을 응용하여 적절하게 진단에 적용할 수 있다.