• 제목/요약/키워드: 3D Bolus

검색결과 60건 처리시간 0.027초

Protection of Peroxynitrite-Induced DNA Damage by Dietary Antioxidants

  • Moon Hye-Kyung;Yang Eun-Sun;Park Jeen-Woo
    • Archives of Pharmacal Research
    • /
    • 제29권3호
    • /
    • pp.213-217
    • /
    • 2006
  • The present study was undertaken to test the hypothesis that dietary antioxidants protect DNA damage induced by peroxynitrite, a potent physiological inorganic toxin. The present study showed that dietary antioxidants such as (-)-epigallocatechin gallate, quercerin, rutin, resveratrol, and ursolic acid inhibit single strand breaks in supercoiled plasmid DNA induced by 3-morpholinosydnomine N-ethylcarbamide (SIN-1), a generator of peroxynitrite through the reaction between nitric oxide and superoxide anion. The formation of 8-hydroxy-2'-deoxyguanosine (8-OH-dG) in calf thymus DNA by SIN-1 was also inhibited by dietary antioxidants. When U937 cells were incubated with 1 mM SIN-1 bolus, a significant increase of 8-OH-dG level was observed. However, oxidative DNA damage was significantly lower in the cells pre-treated with dietary antioxidants when cells were exposed to SIN-1.

위절제술 환자에서 술전 마그네슘 정주가 술후 통증 및 폐기능 회복에 미치는 영향 (Effects of Preincisional Administration of Magnesium Sulfate on Postoperative Pain and Recovery of Pulmonary Function in Patients Undergoing Gastrectomy)

  • 고성훈;장영익;이준례;한영진;최훈
    • The Korean Journal of Pain
    • /
    • 제13권1호
    • /
    • pp.31-37
    • /
    • 2000
  • Background: Recent studies suggested that a preoperative block of N-methyl-D-aspartate (NMDA) receptors with NMDA antagonists may reduce postoperative pain. In this double-blind study, magnesium sulfate, a natural NMDA receptor antagonist, was administered preoperatively to investigate the effects of magnesium sulfate on postoperative pain and pulmonary function. Methods: Seventy patients who were to undergo gastrectomy under general anesthesia were randomly assigned to one of three groups. Groups 2 and 3 received intravenous magnesium, preoperatively (Group 2: 50 mg/kg bolus, 7.5 mg/kg/hr for 20 hr, Group 3: 50 mg/kg bolus, 15 mg/kg/hr for 20 hr). Group 1 received normal saline as the control group. Visual analog scale (VAS) for postoperative pain and mood, cumulative analgesic consumption, recovery of pulmonary function and side effects were evaluated at 6, 24, 48 and 72 hours after the operation. Results: In Groups 2 and 3, plasma concentration of magnesium were significantly higher than in Group 1 at 6 and 20 hours after infusion (P<0.05). There were no significant differences in the analgesic consumption, and recovery of pulmonary function and the incidence of side effects at 6, 24, 48 and 72 hours after the operation among the three groups. In Group 3, pain scores at rest measured 24 and 48 hours after operation were lower than the control group, and pain scores when deep breathing were significantly lower than the control group at postoperative 6, 24, 48, and 72 hours. Conclusions: We conclude that intravenous infusion of greater amount of magnesium has little effectiveness in reducing postoperative pain. However, further studies are needed to characterize the clinical significance of these effects on postoperative pain.

  • PDF

탄소입자 치료 시 열가소성 고정기구의 공기층에 따른 선량 변화 평가 (Evaluation of Dose Variation according to Air Gap in Thermoplastic Immobilization Device in Carbon Ion)

  • 나예진;장지원;장세욱;박효국;이상규
    • 대한방사선치료학회지
    • /
    • 제35권
    • /
    • pp.33-39
    • /
    • 2023
  • 목 적: 환자 체표면과 고정기구 사이에 발생하는 공기층 두께에 따른 선량 변화를 치료 계획을 통해 알아보고자 한다. 대상 및 방법: 팬텀과 열가소성 고정기구 사이에 5 mm 두께의 Bolus를 0, 1, 2, 3장을 놓아 공기층의 두께를 조절하였고 고정기구를 씌워 총 4가지 조건으로 전산화 모의단층촬영을 시행하였다. 430 cGy (Relative Biological Effectiveness,RBE)씩 6번이 조사 되도록 계획하였으며, 임상표적체적의 95% 부피에 전달된 선량이 2580 cGy (RBE)가 되도록 치료 계획을 수립하였다. 임상표적체적의 선량은 Lateral dose profile의 반치폭값으로 평가하였고 피부 선량은 선량 체적 곡선으로 평가하였다. 결 과: 임상표적체적에서 Lateral dose profile 반치폭 값은 4.89, 4.86, 5.10, 5.10 cm로 나타났다. 피부에서 4가지 조건의 선량의 평균값은 D95%3.25±1.7 cGy (RBE), D30%1193.5±10.2 cGy (RBE)의 차이를 보였으며 처방 선량 1%에서의 피부 부피 값 평균은 83.22±4.8% 이내의 차이를 확인하였다. 공기층 두께 변화에 따른 임상표적체적과 피부에서의 선량 모두 큰 변화를 보이지는 않았다. 결론 : 탄소입자 치료를 위해 Solid 형태의 고정기구 제작 시 약간의 공기층은 CTV의 선량 적용 범위를 벗어나지 않는다.

  • PDF

마우스에서 뇌관류법과 정맥투여법에 의하여 흰쥐 트란스페린 단일항체의 체내동태 및 혈액-뇌 관문 투과성의 검토 (The Determination of Blood-Brain Barrier Permeability and Pharmacokinetics of a Rat Transferrin Receptor Monoclonal Antibody by Brain Perfusion Method and Intravenous Injection Technique in Mice)

  • 강영숙
    • Biomolecules & Therapeutics
    • /
    • 제10권1호
    • /
    • pp.37-42
    • /
    • 2002
  • Brain drug targeting through the blood-brain barrier (BBB) in vivo is possible with peptidornirnetic monoclonal antibodies that undergo receptor-mediated transcytosis through the BBB. Monoclonal antibody to the rat transferrin receptor, such as the OX26 was studied in rats as a transport vector through BBB on the transferrin receptor. But, OX26 is not an effective brain delivery vector in mouse. In the present studies, rat monoclonal antibody, 8D3 to the mouse transferrin receptor were evaluated for brain drug targeting vector intransgenic mouse model. Pharrnacokinetic parameters in plasma and organ uptakes were determined at varioustimes after i.v. bolus injection of [$^{}125}I$] 8D3 in Balb/c mice. Brain uptake of [$^{}125}I$] 8D3 was also studied with an internal carotid artery perfusioncapillary depletion method. After i.v. injection of [$^{}125}I$] 8D3, plasma concentrations declined biexponentially with elimination half lift of approximately 2.2 hours. Brain uptake of [$^{}125}I$] 8D3 was $0.50{\pm}0.09$ persent of injected dose per g brain after 2 hours i.v. injection. After perfusion 5 min the apparent volume of distibution of [$^{}125}I$] 8D3 in brain was $22.3 {\mu}l/g,$ which was 4.8 fold higher than the intravascular volume. These studies indicate rat monoclonal antibody to the mouse transferrin receptor, 8D3 may be used for brain drug targeting vector in mice.

정맥내의 IV 카테터 조각의 3D MDCT 재구성 영상 (Findings of an Intravenous Catheter Fragment in the Vein Using the 3D Image Reformations of MDCT)

  • 권대철;유병규;양성환;김정구
    • 한국의학물리학회지:의학물리
    • /
    • 제17권3호
    • /
    • pp.167-172
    • /
    • 2006
  • 전산화단층촬영에서 조영 증강을 위한 조영제 주입은 정맥내에 삽입한 카테터를 통해 자동주입기로 주입하고 있다. 정맥내에 위치한 카테터를 제거하는 도중에 IV 카테터가 부러져 정맥내에 남아 있는 카테터의 조각은 환자에게 순환기 질환의 위험을 초래할 수 있다. CT 검사 중에 정맥내에 카테터 조각이 남아있는 2명의 환자를 대상으로 카테터의 크기 및 위치를 정확히 확인하기 위해 MDCT를 이용하여 정맥내 주사부위를 스캔하였다. 3D 재구성은 MPR, MIP, 볼륨렌더링, SSD 등으로 구성하였다. 정맥내에 위치한 카테터 조각을 MDCT로 스캔한 데이터를 3D 재구성으로 정맥내의 위치 및 크기를 확인하였고, 카테터 조각을 제거하는데 일조하였다.

  • PDF

The Effect of Low-dose Ketamine on Post-caesarean Delivery Analgesia after Spinal Anesthesia

  • Han, Seung Yeup;Jin, Hee Cheol;Yang, Woo Dae;Lee, Joon Ho;Cho, Seong Hwan;Chae, Won Seok;Lee, Jeong Seok;Kim, Yong Ik
    • The Korean Journal of Pain
    • /
    • 제26권3호
    • /
    • pp.270-276
    • /
    • 2013
  • Background: Ketamine, an N-methyl-D-aspartate receptor antagonist, might play a role in postoperative analgesia, but its effect on postoperative pain after caesarean section varies with study design. We investigated whether the preemptive administration of low-dose intravenous ketamine decreases postoperative opioid requirement and postoperative pain in parturients receiving intravenous fentanyl with patient-controlled analgesia (PCA) following caesarean section. Methods: Spinal anesthesia was performed in 40 parturients scheduled for elective caesarean section. Patients in the ketamine group received a 0.5 mg/kg ketamine bolus intravenously followed by 0.25 mg/kg/h continuous infusion during the operation. The control group received the same volume of normal saline. Immediately after surgery, the patients were connected to a PCA device set to deliver 25-${\mu}g$ fentanyl as an intravenous bolus with a 15-min lockout interval and no continuous dose. Postoperative pain was assessed using the cumulative dose of fentanyl and visual analog scale (VAS) scores at 2, 6, 24, and 48 h postoperatively. Results: Significantly less fentanyl was used in the ketamine group 2 h after surgery (P = 0.033), but the difference was not significant at 6, 12, and 24 h postoperatively. No significant differences were observed between the VAS scores of the two groups at 2, 6, 12, and 24 h postoperatively. Conclusions: Intraoperative low-dose ketamine did not have a preemptive analgesic effect and was not effective as an adjuvant to decrease opioid requirement or postoperative pain score in parturients receiving intravenous PCA with fentanyl after caesarean section.

The Role of Dynamic Contrast Enhanced MR Mammography in Differentiation between Benign and Malignant Breast Lesions

  • 한송이;차은숙;정상설;김학희;변재영;이재문
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.135-135
    • /
    • 2002
  • Purpose: To assess diagnostic accuracy of dynamic contrast enhanced MR mammography in differentiating between benign and malignant lesions. Materials and methods: Ninety-three patients with suspicious mammographic, sonographic or palpable findings underwent pre- or postoperative contrast-enhanced MR imaging of breast using three dimensional fast low-angle shot (3D FLASH) sequence (16/4 msec[repetition time / echo time], 20 flip angle, 3mm slice thickness with no slice gap, 256 by 256 in-plane matrix) covering whole breasts. T1 weighted images were obtained before and after bolus administration of gadopentetate dimeglumine (0.15 mmol/kg). Subtraction images and time-signal intensity curves of region of interest were obtained sequentially and correlated with pathologic diagnoses of lesions.

  • PDF

인공 유방 확대술을 받은 환자의 유방암 치료 시 크기에 따른 반대 측 유방의 피폭 선량 및 차폐 효율 평가 (The evaluation of contralateral breast's dose and shielding efficiency by breast size about breast implant patient for radiation therapy)

  • 김종욱;우헌;정현학;김경아;김찬용;유숙현
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.329-336
    • /
    • 2014
  • 목 적 : 인공 유방 확대술을 받은 환자가 유방암 방사선치료를 받을 경우 유방의 크기별로 치료 조사야와의 거리에 따른 치료반대 측 유방조직에 피폭되는 선량 및 차폐의 효율성을 평가해 보고자 한다. 대상 및 방법 : 인체팬텀(Rando-phantom)을 이용하여 유방 모형의 크기별 (200 cc ~ 500 cc) CT영상을 획득한 후 크기 별로 일 선량 180 cGy의 왼쪽 유방암 방사선 치료계획을 세웠다. 유방 모형이 커질수록 치료 반대 측 유방모형의 표면과 X선의 진행지점 사이에 발생하는 거리가 가까워지게 설정하였고, 체표에 입사하는 선속중심축을 기준으로 3 cm, 6 cm 떨어진 점에서 반대측 유방 표면에 수직으로 내린 거리를 각 A point, B point로 설정하였다. 그리고 유두지점에서 외측으로 2 cm 되는 점을 C point, 체표중앙에서 외측으로 6 cm 되는 점을 D point로 설정하였다. 유방 모형의 크기별로 각 측정지점에 MOSFET을 부착하여 6 MV, 10 MV, 15 MV의 X선 에너지로 조사하여 측정하였다. 이와 동일한 조건으로 납 2 mm의 두께로 차폐한 후의 선량 값과 납 2 mm 아래에 bolus 3 mm를 부착하여 차폐한 후의 선량 값을 얻었다. 결 과 : 유방 모형이 200 cc에서 500 cc로 커짐에 따라 유방 모형의 표면과 X선의 진행지점과의 거리가 A point에서는 2.14 cm에서 최대 1.23 cm으로 근접하였고 B point에서는 2.55 cm에서 1.31 cm으로 근접하였다. 유방 모형의 크기에 따라 180 cGy 기준으로 200 cc 대비 500 cc의 산란선 측정값이 A point에서 3.22 ~ 4.17%, B point에서 4.06 ~ 6.22%, C point는 0.4~0.5% 증가하였고, D point에서는 크기별로 측정값의 차이가 0.4% 미만이었다. X선 에너지가 커짐에 따라 6 MV 대비 15 MV X선에서 180cGy 기준으로 산란선이 A point에서는 4.06~5%, B point에서는 2.85~4.94%, C point에서는 0.74~1.65% 증가하였고, D point에서는 측정값 차이가 0.4% 미만이었다. 차폐체로 납 2 mm를 사용하였을 경우 A와 B point에서 평균 9.74%, C point에서 2.8%, D point에서 1% 미만의 산란선 감소효과가 있었고, 납과 bolus를 함께 차폐하였을 경우 A와 B point에서 평균 9.76%, C point에서 2.2%, D point에서 1% 미만의 산란선 감소효과가 있었다. 결 론 : 일반적으로 인공 유방 확대술을 받은 환자의 경우 유방의 크기에 따라 치료 반대편 유방 표면과 치료조사야의 거리가 가까울수록 유방 표면이 받는 산란선이 증가하였다. 동일한 크기의 유방 모형에서는 사용 X선 에너지가 커질수록 산란선에 의한 피폭이 증가하는 경향을 보였고, 이는 사용 X선의 에너지 선택에 있어 유방암의 방사선 치료계획에서 허용되는 한도에서는 낮은 X선 에너지의 사용이 반대측 유방의 선량 감소에 유리할 것으로 여겨진다.

흰쥐에서의 신규 항암제 BR-28702-2의 체내동태 (Pharmacokinetic Study on BR-28702-2, a New Anticancer Drug, in Rats)

  • 용철순;이신웅;전철수;채희상;신원섭;백우현
    • Biomolecules & Therapeutics
    • /
    • 제3권2호
    • /
    • pp.97-103
    • /
    • 1995
  • The purpose of this study was to determine pharmacokinetic parameters of BR-28702-2, a new antineoplastic agent which is the conjugate of nucleotide and phospholipid, and to compare them with those of ara-C. Male rats were cannulated in the left femoral vein and received a single i.v. bolus dose of either BR-28702-2 or ara-C. BR-28702-2 was also administered i.p. and plasma samples were analyzed by reversedphase HPLC. The t$_{1}$2($\beta$)/ of ara-C(1.22 hr.) was significantly smaller than that of BR-28702-2(4.420 hr.). The absolute bioavailability of BR-28702-2 after i.p. injection was 1.125%. This lower bioavailability, together with previous reports that marked antineoplastic activity was observed when given i.p., indicates that BR-28702-2 would act as a depot system to release active moieties. Further works, therefore, need to be done to characterize active metabolites.

  • PDF

필름계측을 이용한 3차원 소동물 팬텀의 선량평가 (Dose Evaluation of Three-Dimensional Small Animal Phantom with Film Dosimetry)

  • 한수철;박승우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.87-92
    • /
    • 2017
  • 소동물을 대상으로 방사선을 이용한 비임상 연구에서 소동물 선량평가의 역할은 계속적으로 증가하고 있다. 본 연구는 최근 들어 사용 및 연구가 계속적으로 증가하고 있는 3차원 프린터를 이용하여 3차원 소동물 팬텀을 제작하였으며, 제작된 소동물 팬텀을 대상으로 필름계측을 이용하여 감마선 조사 시 소동물 팬텀내 흡수되는 선량을 평가하였다. 선행적으로 3차원 소동물 팬텀 제작에 사용된 재료에서 필름에 대한 방사선의 반응 관계식을 획득하였으며, 방사선치료 시 조직등가물질로 사용되고 있는 bolus와 비교하였다. 0.5 Gy에서 6 Gy까지 감마선을 조사하였을 때, 0.5 Gy의 선량을 제외하고 1% 이내의 작은 차이가 있음을 확인하였다. 또한 제작된 3차원 소동물 팬텀 내에 필름을 삽입하여 5 Gy의 선량을 조사하였을 때, 조사된 선량과 필름을 통하여 계산된 선량과의 차이는 2% 이내의 차이였다. 본 연구를 기반으로 실제 소동물을 대상으로, 3차원 소동물 팬텀을 제작하여 선량을 평가한다면, 소동물을 대상으로 방사선 조사하는 비임상 연구 선량에 대한 신뢰성을 높여 줄 수 있을 것이라 사료된다.