• Title/Summary/Keyword: 3D 측정

Search Result 6,578, Processing Time 0.045 seconds

Numerical analysis for nearfield measurement error in a three-dimensional intensity probe. (3차원 인텐시티 프로브의 근거리 음장 측정에서의 오차 수치해석)

  • Kim, Suk-Jae;Jee, Suk-Kun;Suzuki, Hideo;Kim, Chun-Duck
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.41-50
    • /
    • 1994
  • We studied an inherent error be caused by a measuring acoustic intensity using probe which can measure simultaneously the three-dimensional acoustic intensity. This three-dimensional intensity probe was constructed with four microphones, proposed by Suzuki et al. . In the computer simulation, we analyzed the nearfield measurement error with arbitary direction and each of axis direction on the ideal point source and the plate sound source which have finite size. From the results, in case of point source, we obtained accurate measurement below about 1dB when the distance of measurement was about 2.5 times with the distance among microphones in this probe. And in the case of plate sound source, the nearfield measurement error was decreased as the length of one side became above 0.02m, we obtained accurate measurement below about 1dB when the length of one side is 0.2m. The nearfield measurement error of finite size sound is small to ignore. Therefore this probe is useful to measure nearfield intensity.

  • PDF

Improving 3D Measurement Speed using CUDA (CUDA를 이용한 3D 측정 속도 향상)

  • Kim, Ho-Joong;Cho, Tai-Hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.331-334
    • /
    • 2017
  • Recently, a method using a fringe pattern is widely used for 3D measurements. This is a method of measuring by using a phase value obtained by projecting a pattern to an object to be measured. This method requires many operations such as calculating the phase value and calculating the height. It takes a lot of time depending on the amount of computation. In this paper, we present a method using NVIDIA's CUDA to reduce this time. And we introduce the method of calculating phase value and height. It also shows the exact time difference between the CPU version and the CUDA version. This method is very effective because it can process the same operation in a shorter time.

  • PDF

Development of Frequency Converter for 2.5/3.5/5.5 GHz m-WiMAX System Wireless Measurement using WiBro Network (WiBro 망을 이용한 2.5/3.5/5.5 GHz m-WiMAX 시스템 무선 측정용 주파수 변환기 개발)

  • Kim, Se-Hwan;Chun, Kuk-Jin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.2
    • /
    • pp.1-5
    • /
    • 2011
  • For measuring quad-band module system using WiBro network, frequency converter was developed. The size of the fabricated frequency converter is $3.1cm{\times}3.1cm{\times}0.4cm$. Noise figure of the receiver part of the frequency converter was 2.62 ~ 3.45 dB, EVM of that is -37.5 dB ~ -34.5 dB. And EVM of the transmission part was -42.5 ~ -35.5 dB. Quad-band module was fabricated with the developed frequency converter. Testing the quad-band module in 2.3 GHz WiBro network results the excellent internet connection for 2.5 GHz, 3.5 GHz and 5.5 GHz band.

Proposal of Nail Tip Size by Measuring Nail Size of Korean Women in Their 20s -Focusing on Size Comparison Through Direct Measurement and 3D Scanner Measurement- (20대 국내여성의 손톱 사이즈 측정을 통한 네일 팁 사이즈 제안 -직접측정법과 3D 스캐너측정법을 통한 사이즈 비교를 중심으로-)

  • Lee, Eunsil;Kim, Eunsil
    • Journal of Fashion Business
    • /
    • v.24 no.1
    • /
    • pp.102-116
    • /
    • 2020
  • After its introduction in Korea, nail art is becoming active, especially among women in their 20s and 30s who are interested in fashion and beauty. Although self-nail tips are available online in various designs for each brand that is currently on the market, these designs and sizes of self-nail tips on the market are different for each age group. Since the design or size is not suggested for the different situations, there are difficulties in purchasing products that match the shape and size of nails of consumers. In this study, frequency analysis was performed using 'SPSS statistics 21.0 for windows program' to analyze data obtained by direct measurement method and 3D scanner measurement method for Korean women in their 20s. For comparative analysis between direct and 3D scanner measurements, a corresponding sample, 'T-test', was performed. As a result, we proposed the standardization of nail tip size after comparative analysis between direct measurement and 3D scanner measurement. Previous studies have been proceeding with direct measurement method. However, this study introduced a 3D scanner measurement method in the nail field and attempted the standardization of nail size by age group of Korean women. Importantly, this sutdy suggests standardization of nail tip size among missing body sizes.

Influence of disparity on subjective visual comfort in stereoscopic 3D image (시각적 편안함에 대한 양안식 3D 영상의 양안 시차 영향)

  • Sohn, Hosik;Jung, Yong Ju;Lee, Seong-Il;Ro, Yong Man
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2012.11a
    • /
    • pp.40-41
    • /
    • 2012
  • 양안식 3D 영상 시청 안정성에 대해 제기되고 있는 지속적인 이슈는 3D 영상 시장 활성화를 위해 반드시 선결 되어야 하는 과제이다. 최근, 이를 위해 양안식 3D 영상이 유발하는 시각적 불편함을 측정하고 이를 예측하는 연구가 활발히 진행되고 있다. 본 논문에서는 양안식 3D 영상에서 시각적 불편함을 야기하는 문제 영역의 양안 시차 변화에 따른 주관적 시각적 불편함을 측정한다. 이를 통하여 양안식 3D 영상에서 시각적 불편함을 주는 문제 영역의 영상 특성이 시청자가 인지하는 시각 피로에 지배적인 영향을 미칠 수 있음을 실험적으로 증명한다.

  • PDF

Implementation of the Linear Regression Equation for Gestational Age Prediction in the 3D Ultrasonography (3차원초음파에서 임신주수 예측을 위한 선형회귀방정식의 구현)

  • Yang, SungHee;Lee, Jin-Soo;Kim, Jung-Hoon;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.6
    • /
    • pp.276-282
    • /
    • 2015
  • Fetal cerebellum is grow depending on the gestational age, measurement of transverse cerebellar diameter(TCD) is being used import indicator of fetal growth prediction in clinical. In this study, the subjects were normal pregnant women 20~37 week of gestation, and the volume scan was conducted on the 340 subjects. The research reports was indicated by regression curve the growth of fetal TCD in accordance with the gestational age. It got to the value of the results from a linear regression equation. Measurement fetal TCD using 3D US was statistically significant(p<0.001) and useful in the prediction of gestational age. TCD increases with gestational age can also distinguish between the normal fetal and prediction of accurate gestational age of fetal growth retardation. If the basic data of the present study, ongoing research is performed, the TCD using by 3D US are expected to be usefully applied in the correct prediction gestational age.

Upper Body Surface Change Analysis using 3-D Body Scanner (3차원 인체 측정기를 이용한 체표변화 분석)

  • Lee Jeongran;Ashdoon Susan P.
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.12 s.148
    • /
    • pp.1595-1607
    • /
    • 2005
  • Three-dimensional(3-D) body scanners used to capture anthropometric measurements are now becoming a common research tool far apparel. This study had two goals, to test the accuracy and reliability of 3-D measurements of dynamic postures, and !o analyze the change in upper body surface measurements between the standard anthropometric position and various dynamic positions. A comparison of body surface measurements using two different measuring methods, 3-D scan measurements using virtual tools on the computer screen and traditional manual measurements for a standard anthropometric posture and for a posture with shoulder flexion were $-2\~20mm$. Girth items showed some disagreement of values between the two methods. None of the measurements were significantly different except f3r the neckbase girth for any of the measuring methods or postures. Scan measurements of the upper body items showed significant linear surface change in the dynamic postures. Shoulder length, interscye front and back, and biacromion length were the items most affected in the dynamic postures. Changes of linear body surface were very similar for the two measuring methods within the same posture. The repeatability of data taken from the 3-D scans using virtual tools showed satisfactory results. Three times repeated scan measurements f3r the scapula protraction and scapula elevation posture were proven to be statistically the same for all measurement items. Measurements from automatic measuring software that measured the 3-D scan with no manual intervention were compared with the measurements using virtual tools. Many measurements from the automatic program were larger and showed quite different values.

A 3D measurement system based on a double frequency method using Fourier transform profilometry (FTP를 이용한 이중 파장법에 의한 3차원 형상 측정)

  • Koo, Ja-myoung;Cho, Tai-hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.6
    • /
    • pp.1485-1492
    • /
    • 2015
  • This paper proposes a double frequency method using FTP(Fourier Transform Profilometry) in fringe projection techniques for 3D measurement systems. In fringe projection techniques, fringe pattern images are projected and captured, and then object is measured by analysing phase. PMP(Phase Measuring Profilometry) for analysing phase provides high-resolution and is robust to object's reflection and background intensities. However, the measurement range is narrow due to 2π ambiguity. In order to overcome this problem, a double frequency method is often used. This method can widen the range of measurement while maintaining the high-resolution, but the measurement time is taken about twice due to grab 2 times number of images. The proposed double frequency method using FTP requires an additional image for resolving 2π ambiguity. The proposed method effectively reduces the measurement time while maintaining the same accuracy.

A Study on the Calibration of Shape Measurement System Using Digital moire (Digital moire 형상측정 시스템의 보정에 관한 연구)

  • 유원재;김도훈;안재웅;강영준;노형민
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.199-202
    • /
    • 2002
  • Moire topography method is a well-known non-contacting 3-D measurement method. Recently, the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using digital projection moire topography is very attractive because of its high measuring speed and high sensitivity. In this paper, using different N-bucket algorithm method of digital projection moire topography is tested to measuring object with the 2$\pi$-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding measurement errors that decreased more by using the flour-three step algorithm method than the same step in the phase shifting of different pitchs.

  • PDF

A Study on the Virtual Grating Projection Moire Topography for the Shape Measurement of Human Face (인체형상 측정을 위한 가상격자 영사식 무아레 방법에 관한 연구)

  • 유원재;최정표;안중근;강영준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.49-52
    • /
    • 2001
  • Moire topography method is a well-known non-contacting 3-D measurement method. Recently, the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using projection moire topogrphy is very attractive because of it s high measuring speed and high sensitivity. In this paper, using two-wavelength method of projection moire topography tested to measuring object with the $2\pi$-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding absolute fringe orders, so that the $2\pi$-ambiguity problem can be effectively overcome so as to treat large step discontinuities in measured objects.

  • PDF