• Title/Summary/Keyword: 3D (3Dimensional)

Search Result 6,297, Processing Time 0.041 seconds

A Study on Three-Dimensional Computer Generated Holograms by 3-D Coordinates Transformation (3차원 좌표변환에 의한 입체 컴퓨터 형성 홀로그램에 관한 연구)

  • Ryu, Won-Hyeon;Jeong, Man-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.6
    • /
    • pp.525-531
    • /
    • 2006
  • Synthesized 3-D CGH of a general three dimensional object is obtained by using a new 3-D coordinates transformation technique. A CCD camera is used to record several projected images of the 3-D object from different viewing angles. The recorded data are numerically calculated and processed to yield two-dimensional complex functions, which are then encoded fer the final synthesized 3-D CGH.

Comparison of 64 Channel 3 Dimensional Volume CT with Conventional 3D CT in the Diagnosis and Treatment of Facial Bone Fractures (얼굴뼈 골절의 진단과 치료에 64채널 3D VCT와 Conventional 3D CT의 비교)

  • Jung, Jong Myung;Kim, Jong Whan;Hong, In Pyo;Choi, Chi Hoon
    • Archives of Plastic Surgery
    • /
    • v.34 no.5
    • /
    • pp.605-610
    • /
    • 2007
  • Purpose: Facial trauma is increasing along with increasing popularity in sports, and increasing exposure to crimes or traffic accidents. Compared to the 3D CT of 1990s, the latest CT has made significant improvement thus resulting in higher accuracy of diagnosis. The objective of this study is to compare 64 channel 3 dimensional volume CT(3D VCT) with conventional 3D CT in the diagnosis and treatment of facial bone fractures. Methods: 45 patients with facial trauma were examined by 3D VCT from Jan. 2006 to Feb. 2007. 64 channel 3D VCT which consists of 64 detectors produce axial images of 0.625 mm slice and it scans 175 mm per second. These images are transformed into 3 dimensional image using software Rapidia 2.8. The axial image is reconstructed into 3 dimensional image by volume rendering method. The image is also reconstructed into coronal or sagittal image by multiplanar reformatting method. Results: Contrasting to the previous 3D CT which formulates 3D images by taking axial images of 1-2 mm, 64 channel 3D VCT takes 0.625 mm thin axial images to obtain full images without definite step ladder appearance. 64 channel 3D VCT is effective in diagnosis of thin linear bone fracture, depth and degree of fracture deviation. Conclusion: In its expense and speed, 3D VCT is superior to conventional 3D CT. Owing to its ability to reconstruct full images regardless of the direction using 2 times higher resolution power and 4 times higher speed of the previous 3D CT, 3D VCT allows for accurate evaluation of the exact site and deviation of fine fractures.

Increased SOX2 expression in three-dimensional sphere culture of dental pulp stem cells

  • Seo, Eun Jin;Jang, Il Ho
    • International Journal of Oral Biology
    • /
    • v.45 no.4
    • /
    • pp.197-203
    • /
    • 2020
  • Mesenchymal stem cells in the dental pulp exhibit a tendency for differentiation into various dental lineages and hold great potential as a major conduit for regenerative treatment in dentistry. Although they can be readily isolated from teeth, the exact characteristics of these stem cells have not been fully understood so far. When compared to two-dimensional (2D) cultures, three-dimensional (3D) cultures have the advantage of enriching the stem cell population. Hence, 3D-organoid culture and 3D-sphere culture were applied to dental pulp cells in the current study. Although the establishment of the organoid culture proved unsuccessful, the 3D-sphere culture readily initiated the stable generation of cell aggregates, which continued to grow and could be passaged to the second round. Interestingly, a significant increase in SOX2 expression was detected in the 3D-spheroid culture compared to the 2D culture. These results indicate the enrichment of the stemness-high population in the 3D-sphere culture. Thus, 3D-sphere culture may act as a link between the conventional and 3D-organoid cultures and aid in understanding the characteristics of dental pulp stem cells.

Influence of Two-Dimensional and Three-Dimensional Acquisitions of Radiomic Features for Prediction Accuracy

  • Ryohei Fukui;Ryutarou Matsuura;Katsuhiro Kida;Sachiko Goto
    • Progress in Medical Physics
    • /
    • v.34 no.3
    • /
    • pp.23-32
    • /
    • 2023
  • Purpose: In radiomics analysis, to evaluate features, and predict genetic characteristics and survival time, the pixel values of lesions depicted in computed tomography (CT) and magnetic resonance imaging (MRI) images are used. CT and MRI offer three-dimensional images, thus producing three-dimensional features (Features_3d) as output. However, in reports, the superiority between Features_3d and two-dimensional features (Features_2d) is distinct. In this study, we aimed to investigate whether a difference exists in the prediction accuracy of radiomics analysis of lung cancer using Features_2d and Features_3d. Methods: A total of 38 cases of large cell carcinoma (LCC) and 40 cases of squamous cell carcinoma (SCC) were selected for this study. Two- and three-dimensional lesion segmentations were performed. A total of 774 features were obtained. Using least absolute shrinkage and selection operator regression, seven Features_2d and six Features_3d were obtained. Results: Linear discriminant analysis revealed that the sensitivities of Features_2d and Features_3d to LCC were 86.8% and 89.5%, respectively. The coefficients of determination through multiple regression analysis and the areas under the receiver operating characteristic curve (AUC) were 0.68 and 0.70 and 0.93 and 0.94, respectively. The P-value of the estimated AUC was 0.87. Conclusions: No difference was found in the prediction accuracy for LCC and SCC between Features_2d and Features_3d.

Effects of Geometric and Flow Conditions on 3-dimensional Hydrodynamic Focusing (3 차원 유체역학 집속에 대한 채널 형상 및 유동 조건의 매개변수 연구)

  • Han, Kyung-Sup;Kim, Dong-Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.61-66
    • /
    • 2010
  • In our previous work, 3-dimensional hydrodynamic focusing microfluidic device (3D-HFMD) has been developed with the help of locally increased aspect ratio of thickness to width without any horizontal separation wall. In this study, we have investigated 3-dimensional hydrodynamic focusing behaviors inside the 3D-HFMD according to the various geometric and flow conditions. The parametric study has been extensively carried out for the effects of geometric and flow conditions on 3-dimensional hydrodynamic focusing with both 3D-HFMD and previous microfluidic device design based on three-dimensional computational fluid dynamics (CFD) simulations. The CFD simulations suggested the proper design window of channel geometry and flow conditions.

Transformation of GPS Coordinates in a Small Area (소지역에서 GPS좌표변환에 관한 연구)

  • 조규전;전재홍;차득기;어수창
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.15 no.2
    • /
    • pp.253-261
    • /
    • 1997
  • In general, the transformation of coordinates in GPS is carried out by 3 dimensional transformation method with 3-10 parameter. In korea, the coordinates of transformation points ware determined are adjusted in-dependently by planimetry and the height, and also the weight of observations were not properly applied to the adjustment. In this study, two different transformation methods are tested and analysed by the field test, and it is finally found that 2 dimensional method is more efficient way than 3 dimensional classical transformation method.

  • PDF

3D Printing Application Cases for Medical Service (의료 서비스를 위한 3D 프린팅 기술 적용 사례)

  • Woo, Sung-hee;Kwak, Ji-yeon;Hong, Sung-won
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.988-991
    • /
    • 2015
  • 3D printing technology is instrument that can create real objects in three-dimensional space, as printed on paper, if the three-dimensional designs are made. 3D printing technology has been recently used in various field of medicine, and also biomedical application of three dimensional printing technology remains one of the most important research topics until now. 3D printing technology is causing a revolutionary change in the overall automotive manufacturing, aerospace, marine, medical and so on. The medical industry applications of current 3D printer are a virtual simulation, custom medical implants manufactured, practice of medical personnel. In this study, we analyzed 3D printing technology and application cases for medical services.

  • PDF

Clinical Application of Three-Dimensional Printing Technology in Craniofacial Plastic Surgery

  • Choi, Jong Woo;Kim, Namkug
    • Archives of Plastic Surgery
    • /
    • v.42 no.3
    • /
    • pp.267-277
    • /
    • 2015
  • Three-dimensional (3D) printing has been particularly widely adopted in medical fields. Application of the 3D printing technique has even been extended to bio-cell printing for 3D tissue/organ development, the creation of scaffolds for tissue engineering, and actual clinical application for various medical parts. Of various medical fields, craniofacial plastic surgery is one of areas that pioneered the use of the 3D printing concept. Rapid prototype technology was introduced in the 1990s to medicine via computer-aided design, computer-aided manufacturing. To investigate the current status of 3D printing technology and its clinical application, a systematic review of the literature was conducted. In addition, the benefits and possibilities of the clinical application of 3D printing in craniofacial surgery are reviewed, based on personal experiences with more than 500 craniofacial cases conducted using 3D printing tactile prototype models.

CONTROL OF A 3-DIMENSIONAL POSTPROCESSING SOFTWARE USING DATA GLOVES FOR IMMERSIVE ENVIRONMENT (몰입 환경을 위한 3차원 데이터 후처리 소프트웨어의 데이터 글로브에 의한 제어 구현)

  • Kim K.Y.;Kim B.S.
    • Journal of computational fluids engineering
    • /
    • v.11 no.2 s.33
    • /
    • pp.56-61
    • /
    • 2006
  • As the size and dimension of target problems in the field of computational engineering including CFD gets bigger and higher, it is needed to have more efficient and flexible data visualization environment in terms of software and hardware. Even though it is still manageable to use a mouse in controlling 3-dimensional data visualization, it would be beneficial to use 3-D input device for 3-D visualization. 'Data Glove' is one of the best 3-D input devices, because human hands are best tools for understanding 3-D space and manipulating 3-D objects. Signals coming from 'Data Glove' are analog and very sensitive to finger motions, therefore signal filtering using a digital filter is applied. This paper describes our experience and benefits of using data gloves in controlling 3-dimensional postprocessing softwares.

Comparative study of glenoid version and inclination using two-dimensional images from computed tomography and three-dimensional reconstructed bone models

  • Choi, Chang-Hyuk;Kim, Hee-Chan;Kang, Daewon;Kim, Jun-Young
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.3
    • /
    • pp.119-124
    • /
    • 2020
  • Background: This study was performed to compare glenoid version and inclination measured using two-dimensional (2D) images from computed tomography (CT) scans or three-dimensional (3D) reconstructed bone models. Methods: Thirty patients who had undergone conventional CT scans were included. Two orthopedic surgeons measured glenoid version and inclination three times on 2D images from CT scans (2D measurement), and two other orthopedic surgeons performed the same measurements using 3D reconstructed bone models (3D measurement). The 3D-reconstructed bone models were acquired and measured with Mimics and 3-Matics (Materialise). Results: Mean glenoid version and inclination in 2D measurements were -1.705° and 9.08°, respectively, while those in 3D measurements were 2.635° and 7.23°. The intra-observer reliability in 2D measurements was 0.605 and 0.698, respectively, while that in 3D measurements was 0.883 and 0.892. The inter-observer reliability in 2D measurements was 0.456 and 0.374, respectively, while that in 3D measurements was 0.853 and 0.845. Conclusions: The difference between 2D and 3D measurements is not due to differences in image data but to the use of different tools. However, more consistent results were obtained in 3D measurement. Therefore, 3D measurement can be a good alternative for measuring glenoid version and inclination.