• Title/Summary/Keyword: 3D상관

Search Result 1,885, Processing Time 0.035 seconds

Optical implementation of 3D image correlator using integral imaging technique (집적영상 기술을 이용한 3D 영상 상관기의 광학적 구현)

  • Piao, Yongri;Kim, Seok-Tae;Kim, Eun-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.8
    • /
    • pp.1659-1665
    • /
    • 2009
  • In this paper, we propose an implementation method of 3D image correlator using integral imaging technique. In the proposed method, elemental images of the reference and signal 3D objects are recorded by lenslet arrays and then reference and signal output plane images with high resolution are optically reconstructed on the output plane by displaying these elemental images into a display panel. Through cross-correlations between the reconstructed reference and the single plane images, 3D object recognition is performed. The proposed method can provide a precise 3D object recognition by using the high-resolution output plane images compared with the previous methods and implement all-optical structure for real-time 3D object recognition system. To show the feasibility of the proposed method, optical experiments are carried out and the results are presented.

Assessing the Relationship Between Core Technologies of the Fourth Industrial Revolution and Company Sales (4차 산업혁명 핵심기술과 기업의 매출액 간 상관관계 평가)

  • Hanmin Gu;Uihyun Hwang;Kabsung Kim
    • Industry Promotion Research
    • /
    • v.8 no.2
    • /
    • pp.1-9
    • /
    • 2023
  • To bridge the research gap in the area of the Fourth Industrial Revolution, we explore the correlation between the core technologies of the Fourth Industrial Revolution and the economic performance of companies. The results show that the technologies have a statistically significant positive (+) correlation with company sales. The size of the correlation is highest for 3D printing (139%), followed by big data (129%), cloud computing (127%), artificial intelligence (78%), and the internet of things (70%). We also found a statistically significant negative (-) interaction effect between the internet of things and 3D printing, cloud computing and big data, and cloud computing and 3D printing when examining the interaction effect of introducing core technologies of the Fourth Industrial Revolution on company sales. This paper represents an early attempt to examine the correlation between the core technologies of the Fourth Industrial Revolution and the economic performance of companies and may serve as a basis for further empirical research.

Variation of Morphological Similarity between Rice Breeding Lines in the Different Fertilizer Levels (시비량에 따른 수도 계통간의 형태적 유사도 변이)

  • 이영만;구자옥
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.30 no.4
    • /
    • pp.375-380
    • /
    • 1985
  • Single linkage dendrograms by Mahalanobis's D$^2$, Q correlation, and distance from Principal Component Analysis, respectively, were made to eight rice breeding lines in the none and high fertilizer levels. The dendrograms in the two fertilizer levels were similar in shape. The shape of dendrograms by D$^2$ and Q correlation were identical and they were very similar in shape to that by PCA in the both fertilizer levels.

  • PDF

Integral Image Coding Method for 3D Image (3D 입체 영상을 위한 집적 영상 압축 방법)

  • Jeon, Ju-Il;Lee, Kang-San;Kang, Hyun-Soo
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.235-238
    • /
    • 2009
  • 본 논문에서는 집적 영상을 효율적으로 압축하는 방법을 제안한다. 렌즈 어레이를 이용하여 획득되는 집적 영상은 3차원 영상을 기록하고 표현하는 기술 중에 하나이다. 3차원 영상의 복원은 각 요소영상의 해상도에 의해 많은 영향을 받음에 따라 효율적인 집적영상 압축은 매우 중요하다고 할 수 있다. 제안된 방법은 3D 이산 코사인 변환(3D-DCT)를 기반으로 하고 있다. 3D-DCT는 렌즈 어레이로 촬영된 인접 영상들 간의 교차 상관도를 이용하여 영상간 중복성을 줄여 압축 효율을 향상시킬 수 있는 방법이다. 제안방법은 인접 영상들 간의 교차 상관도를 고려하여, 동일 위치의 픽셀들로 $8{\times}8$ DCT블록을 재구성하여 3D-DCT를 수행한다. 제안 방법은 기존의 JPEG이나 기존의 3D-DCT를 이용한 방법과 비교해 더 좋은 성능을 보여준다.

  • PDF

Characteristics of 2nd to 4th Digit Ratio according to Type of Handedness in University Students (대학생의 손잡이 유형에 따른 손가락 길이비(2D:4D)의 특성)

  • Kim, Sooil;Cho, Keun-Ja
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1245-1251
    • /
    • 2013
  • The aim of this study is to identify characteristics of 2D:4D according to type of handedness. Data was collected from October, 4th, 2010 to April, 30th, 2012. After handedness assessment, 2nd and 4th finger length were measured by vernier calipers. This study showed remarkable gender difference of 2D:4D in left hand for left handers and right hand for right handers, However, there was no significant difference according to type of handedness in each gender. The correlation between left and right 2D:4D in males right handedness was higher than that of male left handedness, otherwise, in case of female, that of left handedness was higher than that of right handedness. The results of this study suggest that the 2D:4D of left handedness does not differ from that of right handedness, however, gender difference and correlation between left and right 2D:4D show different characteristics according to handedness.

Wideband 6-port Phase Correlator Using Caxial Cable Impedance Transformer and Wireline Coupler (동축선 임피던스 변환기와 Wireline Coupler를 이용한 광대역 6-단자 위상 상관기)

  • Park, Ung-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.8
    • /
    • pp.1188-1195
    • /
    • 2022
  • The 6-port phase correlator consists of one in-phase power divider and three 3-dB 90-degree phase difference power dividers, and is mainly used in a demodulation circuit that determines the phase of an input signal. This paper proposes the wideband 6-port phase correlator that consists of an in-phase power divider using a wideband 2:1 impedance transformer with three 37.5-Ω coaxial cables, and a 3-dB 90-degree phase difference power divide using Wireline. The proposed wideband phase correlator fabricated at a center frequency of 1000MHz has the value of the input reflection coefficient(S11 and S22) -14dB or less in the frequency range of 640~1270MHz. Also, the signal transmission characteristic(Si1), from the in-phase power divider input port to four output ports, has the amplitude of -6.5±0.6dB and the phase error of within ±3.4°, and the signal transmission characteristic(Si2), from the 90 degree phase difference power divider input port to four output ports, has the amplitude of -6.1±0.6dB and the phase error of within ±6.2°.

Correlation Analysis Between 3D Kidneys Measurements and Abdominal Obesity Level in Computed Tomography (전산화단층영상에서 콩팥 3차원 영상 계측치와 복부 비만도 간의 상관관계 분석)

  • Ji-Yeong Kim;Youl-Hun Seoung
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.315-325
    • /
    • 2023
  • The purpose of this study was to predict abdominal obesity with 3-Dimensional computed tomography (3D CT) measurements of kidneys by analyzing the correlation between kidney sizes and abdominal obesity level. The subjects were 178 healthy adults without underlying diseases who had a comprehensive health examination at the Health Medical Center of Jesus Hospital in Jeonju. Abdominal obesity was measured by CT cross-sectional image at the level of the umbilicus and divided into visceral fat area, subcutaneous fat area, visceral fat/total fat ratio. The average comparison of kidney sizes classified according to abdominal obesity were performed through one-way analysis of variance (ANOVA) and Scheffe test. Pearson correlation analysis was performed to correlate all measurement values. The results of kidney size ANOVA analysis according to abdominal obesity were as follows. The means of kidney measurements according to visceral fat classification were significantly different in all kidney measurements (p<0.05). And in case of subcutaneous fat classification, the means of kidney measurements by 3D CT of the severe obesity group were significantly different in the right kidney width (p<0.05). In case of visceral fat area/total fat area ratio, the means of kidney measurements by 3D CT of the severe obesity group were significantly different in both kidneys width (p<0.05). Pearson correlation between kidneys measurements and CT abdominal obesity showed that visceral fat area had the highest correlation with the left kidney width measured by 3D CT (r=0.467) and subcutaneous fat area had correlation with the right kidney width measured by 3D CT (r=0.249). The visceral fat area/total fat area ratio had correlation with the left kidney width measured by 3D CT (r=0.291).

Analysis of Refractive Errors of the before and after Cataract Surgery by Auto-refractor (안굴절계를 이용한 백내장 수술전후의 굴절이상 분석)

  • Oh, Hyun-Jin;Jung, Mi-A
    • Journal of Convergence Society for SMB
    • /
    • v.6 no.3
    • /
    • pp.65-69
    • /
    • 2016
  • We investigated refractive errors and corneal power with 3 factors such as M, $J_0$, and $J_{45}$ as power vector to find out the changes of refractive errors of the before and after cataract surgery in 119 adults aged 45~85 years with cataract. After the surgery, the 3 factors were changed as $-0.29{\pm}2.38D$ to $-0.18{\pm}0.69D$ in spherical equivalent power which is the M factor, $-0.34{\pm}0.68D$ to $-0.05{\pm}0.42D$ in the $J_0$ factor, and $0.11{\pm}0.45$ to $0.02{\pm}0.17$ in the $J_{45}$ factor. Before and after the surgery, corneal mean refractive power, $J_0$, and $J_{45}$ were changed from $44.11{\pm}1.61D$ to $44.20{\pm}1.58D$, $0.01{\pm}0.50D$ to $0.08{\pm}0.49D$, and $0.02{\pm}0.29$ to $0.08{\pm}0.49$, respectively. The results showed that $J_0$ was the highest relativeness in correlation of the pre- and post-surgery for refractive errors, mean corneal power was the highest correlation for corneal power factor, and corneal power factor was the higher correlation much more than refractive error factor.

Material Properties of 3D Printed Mortars Produced with Synthetic Fibers and Biopolymers (합성섬유 및 바이오 폴리머를 혼입한 3D 프린팅 모르타르의 재료특성)

  • Hyo-Jung Kim;Byung-Jae Lee;Yun-Yong Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.4
    • /
    • pp.78-85
    • /
    • 2023
  • In this study, synthetic fibers were applied to reduce shrinkage cracks that may occur in mortar produced by 3D printer. We used a biopolymer in powder form made from cactus stem (CS) as an admixture. The material properties of 3D printed mortar were experimentally evaluated. Replacing methylcellulose(MC) with 10% CS increases compressive strength by 9.84-23.92% regardless of the casting method. In addition, regardless of the casting method, shrinkage change, freeze-thaw resistance, and crack resistance are more effective than Plain. Incorporation of CS increases the polysaccharide macromolecular structure and improves durability. Mortars reinforced with synthetic fibers do not affect compressive strength and freeze-thaw. It is also effective for shrink deformation and crack resistance. Incorporating CS and fibers from 3D-printed mortar was found to be effective for durability and crack resistance.