• Title/Summary/Keyword: 3AP

Search Result 1,489, Processing Time 0.029 seconds

The effect of AP deployment on the accuracy of indoor localization (실내 측위에서 AP 배치가 측위 정확도에 미치는 영향 분석)

  • Kim, Sang-Dong;Lee, Jong-Hun;Jung, Woo-Young;Park, Yong-Wan
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.169-170
    • /
    • 2007
  • In this paper, we analyze the effect of access point (AP) deployment on the accuracy of indoor localization. Two representative geometrical arrangements of AP deployment are selected. One is that a Tag is centered at the regular triangle composed of 3 AP's, and the other is that a Tag is set apart from the straight line composed of 3 AP's. As a result of simulation, the first case has a probability of 93% with distance errors within 1m, while the second case has a 32% of probability.

  • PDF

Statistical Model Analysis of Urban Spatial Structures and Greenhouse Gas (GHG) - Air Pollution (AP) Integrated Emissions in Seoul (서울시 도시공간구조와 온실가스-대기오염 통합 배출량의 통계모형분석)

  • Jung, Jaehyung;Kwon, O-Yul
    • Journal of Environmental Science International
    • /
    • v.24 no.3
    • /
    • pp.303-316
    • /
    • 2015
  • The relationship between urban spatial structures and GHG-AP integrated emissions was investigated by statistically analyzing those from 25 administrative districts of Seoul. Urban spatial structures, of which data were obtained from Seoul statistics yearbook, were classified into five categories of city development, residence, environment, traffic and economy. They were further classified into 10 components of local area, population, number of households, residential area, forest area, park area, registered vehicles, road area, number of businesses and total local taxes. GHG-AP integrated emissions were estimated based on IPCC(intergovernmental panel on climate change) 2006 guidelines, guideline for government greenhouse inventories, EPA AP-42(compilation of air pollutant emission factors) and preliminary studies. The result of statistical analysis indicated that GHG-AP integrated emissions were significantly correlated with urban spatial structures. The correlation analysis results showed that registered vehicles for GHG (r=0.803, p<0.01), forest area for AP (r=0.996, p<0.01), and park area for AP (r=0.889, p<0.01) were highly significant. From the factor analysis, three groups such as city and traffic categories, economy category and environment category were identified to be the governing factors controlling GHG-AP emissions. The multiple regression analysis also represented that the most influencing factors on GHG-AP emissions were categories of traffic and environment. 25 administrative districts of Seoul were clustered into six groups, of which each has similar characteristics of urban spatial structures and GHG-AP integrated emissions.

A Handoff Improvement Method for AP Choose Guarantee Network Performance of Mobile Node in Wireless LAN Systems (무선랜 시스템에서 모바일 노드의 네트워크 성능을 보장하는 AP 선택을 위한 핸드오프 개선기법)

  • Kim, Dong-Geun;Kim, Sang-Bok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.3
    • /
    • pp.55-63
    • /
    • 2010
  • On Handoff, existing AP search has chosen one of various APs according to signal strength. However IEEE 802.11 uses Medium Access method with CSMA/CA(Carrier Sensing Multiple Access /Collision Avoidance) that competes to obtain a channel by sharing common medium. For that reason, network performance is heavily affected by the number of nodes and network congestion aside from signal strength. Consequently, in this paper we propose the method that choose one AP which ensures more improved network performance and set up a link, reflecting AP network information in Handoff area, on Handoff in the process of AP selection. We also demonstrate through simulation that it gets maximum performance even in the wireless network which many users concurrently access to, and it has considerable effects on aspects of resources and network management by distribution of users.

Computed Tomography Assessment of Severity of Acute Pancreatitis in Bangladeshi Children

  • Kaniz Fathema;Bazlul Karim;Salahuddin Al-Azad;Md. Rukunuzzaman;Mizu Ahmed;Tasfia Jannat Rifah;Dipanwita Saha;Md. Benzamin
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.27 no.3
    • /
    • pp.176-185
    • /
    • 2024
  • Purpose: Acute pancreatitis (AP) is common among children in Bangladesh. Its management depends mainly on risk stratification. This study aimed to assess the severity of pediatric AP using computed tomography (CT). Methods: This cross-sectional, descriptive study was conducted in pediatric patients with AP at the Department of Pediatric Gastroenterology and Nutrition, BSMMU, Dhaka, Bangladesh. Results: Altogether, 25 patients with AP were included, of whom 18 (mean age, 10.27±4.0 years) were diagnosed with mild AP, and 7 (mean age, 10.54±4.0 years) with severe AP. Abdominal pain was present in all the patients, and vomiting was present in 88% of the patients. Etiology was not determined. No significant differences in serum lipase, serum amylase, BUN, and CRP levels were observed between the mild and severe AP groups. Total and platelet counts as well as hemoglobin, hematocrit, serum creatinine, random blood sugar, and serum alanine aminotransferase levels (p>0.05) were significantly higher in the mild AP group than in the severe AP group (p=0.001). The sensitivity, specificity, positive predictive value, and negative predictive value of CT severity index (CTSI) were 71.4%, 72.2%, 50%, and 86.7%, respectively. In addition, significant differences in pancreatic appearance and necrosis were observed between the two groups on CT. Conclusion: CT can be used to assess the severity of AP. In the present study, the CTSI effectively assessed the severity of AP in pediatric patients.

A Wireless AP Power Saving Algorithm by Applying Sleep Mode and Transmission Power Coordination in IoT Environments (사물 인터넷 환경에서 무선 AP의 수면 모드 운영 및 송출 전력 조절을 통한 전력 소비 절감 알고리즘)

  • Jeong, Kyeong Chae;Choi, Won Seok;Choi, Seong Gon
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.3 no.11
    • /
    • pp.393-402
    • /
    • 2014
  • We have experienced an explosive increase of the IoT(Internet of Things) technology based devices including smart phones and the wireless communications. Also the growing power consumption in IEEE 802.11 WLANs(Wireless LANs) driven by these dramatic increases in not only mobile users and but also wireless APs(Access Points). To reduce the power consumption, this paper proposes a wireless AP power saving algorithm, which minimizes the transmission power without decrease the transmission and carrier sense ranges. A wireless AP which is use in our algorithm checks its own original coverage periodically for whether there is a new STA(Station) or not when its transmission power is decreased. Moreover, if there are no signaling message to connect the wireless AP, it changes its operation mode Wake-up to sleep. A Result shows that the proposed AP algorithm can reduce the total power consumption of the wireless AP approximated 18% and 35% compared to the conventional wireless AP with and without the existing power saving algorithm, respectively.

Proposed Institutional Diagnostic Reference Levels in Computed and Direct Digital Radiography Examinations in Two Teaching Hospitals

  • Emmanuel Gyan;George Amoako;Stephen Inkoom;Christiana Subaar;Barry Rahman Maamah
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.1
    • /
    • pp.9-14
    • /
    • 2023
  • Background: The detectors of both computed radiography (CR) and direct digital radiography (DR) have a wide dynamic range that could tolerate high values of exposure factors without an adverse effect on image quality. Therefore, this study aims to assess patient radiation dose and proposes institutional diagnostic reference levels (DRLs) for two teaching hospitals in Ghana. Materials and Methods: CR and DR systems were utilized in this study from two teaching hospitals. The CR system was manufactured by Philips Medical Systems DMC GmbH, while the DR system was manufactured by General Electric. The entrance skin doses (ESDs) were calculated using the standard equation and the tube output measurements. Free-in-air kerma (µGy) was measured using a calibrated radiation dosimeter. The proposed institutional DRLs were estimated using 75th percentiles values of the estimated ESDs for nine radiographic projections. Results and Discussion: The calculated DRLs were 0.4, 1.6, 3.4, 0.5, 0.4, 1.1, 1.0, 1.2, and 1.7 mGy for chest posteroanterior (PA), lumbar spine anteroposterior (AP), lumbar spine lateral (LAT), cervical spine AP, cervical spine LAT, skull PA, pelvis AP, and abdomen AP, respectively in CR system. In the DR system, the values were 0.3, 1.6, 3.1, 0.4, 0.3, 0.7, 0.6, 0.9, and 1.3 for chest PA, lumbar spine AP, lumbar spine LAT, cervical spine AP, cervical spine LAT, skull PA, pelvis AP, and abdomen AP, respectively. Conclusion: Institutional DRLs in nine radiographic projections have been proposed for two teaching hospitals in Ghana for the first time. The proposed DRLs will serve as baseline data for establishing local DRLs in the hospitals and will be a valuable tool in optimizing patient doses.

Protective Effect of Agrimonia pilosa var. Extract on Cultured NIH3T3 Fibroblasts Damaged by Potassium Dichromate (크롬염으로 손상된 배양 NIH3T3 섬유모세포에 대한 짚신나물 추출물의 보호 효과)

  • Lee, Jun-Hee;Seo, Young Mi
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.2
    • /
    • pp.205-213
    • /
    • 2019
  • The protective effect of Agrimonia pilosa var. (AP) extract on potassium dichromate ($K_2Cr_2O_7$)-induced cytotoxicity in cultured NIH3T3 fibroblasts, was examined by performing an XTT assay for the cell viability and antioxidative effects, such as lactate dehydrogenase (LDH) activity and superoxide anion-radical (SAR) scavenging activity. In this study, $K_2Cr_2O_7$ decreased the cell viability significantly in a dose-dependent manner, and the $XTT_{50}$ value was determined to be $37.5{\mu}M$, which was highly-toxic according to the Borenfreund and Puerner' toxic criteria. The antioxidant, butylated hydroxytoluene (BHT), increased remarkably the cell viability damaged by $K_2Cr_2O_7$-induced cytotoxicity in these cultures. With regard to the protective effect of the AP extract on $K_2Cr_2O_7$-induced cytotoxicity, AP extract produced a significant increase in cell viability and antioxidative effects as the inhibitory ability LDH and SAR scavenging ability. These findings suggest that oxidative stress is involved in the cytotoxicity of $K_2Cr_2O_7$, and the AP extract effectively protected the cells from $K_2Cr_2O_7$-induced cytotoxicity by antioxidative effects. These results suggest that natural resources, such as AP extract, may be a putative therapeutic agent for the diminution or treatment of cytotoxicity induced by heavy metallic bases, such as $K_2Cr_2O_7$ correlated with oxidative stress.

Development of Lifecycle Support Modules for the ISO 10303-AP241; Generic model for Lifecycle support of AEC facilities (AEC 시설물 공통모델(ISO 10303-AP241)의 생애주기 지원 모듈 개발)

  • An, Kyung-Ik;Kim, In-Han
    • Korean Journal of Computational Design and Engineering
    • /
    • v.13 no.5
    • /
    • pp.342-351
    • /
    • 2008
  • ISO 10303-AP241 is an Application Protocol of ISO 10303, which specifies the representation of AEC facility's life cycle information. The Working Draft of AP241 was submitted to the TC184/SC4 of ISO in July, 2007 by Korean team of ISO TC184/SC4/WG3. This paper introduces the currently developed draft Ap241 core model, and describes the life cycle support modules which are required to represent the life cycle information of AEC facilities. The draft core model is developed as a generic data model which is useful as a basis for implementation in a data warehouse. This core model could be used in combination with reference data such as PLCS RDL, Gellish table and RDL of ISO 15926. These concepts already exists in ISO 10303-AP221, AP239 and ISO 15926. In order to support maintenance and feedback of operational information concerning the AEC facilities, the AP241 team re-used many modules from AP239, and developed various STEP Application Modules which are adapted from the ISO 15926.

Studies on Biological Characteristics of Lactobacillus II. Conjugal Transfer-frequency of R Plasmids from Lactobacillus to Escherichia coli (유산균(乳酸菌)의 생물학적특성(生物學的特性)에 관한 연구(硏究) II. 약제내성(藥劑耐性) 유산균(乳酸菌)의 R Plasmids 전달빈도(傳達頻度))

  • Kim, Jong Myeon;Song, Hee Jong
    • Korean Journal of Veterinary Research
    • /
    • v.20 no.2
    • /
    • pp.113-118
    • /
    • 1980
  • Total of 11 strains of Ldctobacillus isolated from lactobacillus-fermented milk and-beverage in March 1980 were examined for susceptibility to 8 drugs, and transferability and transfer frequency of R plasmids by conjugation. Of 11 isolates each 2 strains were classified as L. cellobiosus and L. helveticus, each 1 strain as L. plantarum, L. lactis, L. acidophilus, L. delbrueckii, L. casei subsp. casei, L. casei subsp, tolerans and L. salivarius subsp, salivarius by Bergey's manual. Resistance was the most active to na lidixic acid(NA), followed in decreasing order by chloramphenicol(CP), ampicillin(AP), kanamycin(KM) and streptomycin(SM). All of isolates were resistant to NA, each 10 strains to CP and AP, 7strains to KM and 6 strains to SM, indicating all of the isolates were resistant to two or more drugs in combination. No strain was resistant to erythromycin(EM), penicillin(PC) and tetracycline(TC). The most frequently encountered resistant patterns were CP NA AP SM KM, followed by CP NA AP KM, NA AP, CP NA, CP NA AP and CP NA AP SM in order. Transfer experiment of drug resistance showed that of 11 resistant strains, 9 strains transferred parts of their resistance to AP or AP CP or SM AP, indicating 9 strains carried R plasmids determining R(AP), R(AP CP) and R(SM AP). The conjugal frequency of R(AP) from Lactobacillus to E. coli ranged from 2.5{\times}10^{-1} to $5.6{\times}10^{-4}%$, that of R(CP) ranged from 5.0{\times}10^{-1} to 5.0{\times}10^{-3}% and that of R(SM) ranged from 6.0{\times}10^{-5} to 1.4{\times}10^{-5}%, at $37^{\circ}C$ for 18 hours of incubation.

  • PDF

PS-Net : Personalized Secure Wi-Fi Networks (PS-Net : 개인별 보안 Wi-Fi 네트워크)

  • Lee, Nam-Seh;Lee, Ju-Ho;Jeong, Choong-Kyo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.3
    • /
    • pp.497-505
    • /
    • 2015
  • Existing Wi-Fi networks require users to follow network settings of the AP (Access Point), resulting in inconveniences for users, and the password of the AP is shared by all users connected to the AP, causing security information leaks as time goes by. We propose, in this work, a personalized secure Wi-Fi network, in which each user is assigned her own virtual Wi-Fi network. One virtual Wi-Fi per user makes the user-centric network configuration possible. A user sets a pair of her own SSID and password on her device a priori, and the AP publishes its public key in a suitable way. The AP also maintains an open Wi-Fi channel, to which users can connect anytime. On user's request, the user device sends a connection request message containing a pair of SSID and password encrypted with the AP's public key. Receiving the connection request message, the AP instantiates a new virtual AP secured with the pair of SSID and password, which is dedicated to that single user device. This virtual network is securer because the password is not shared among users. It is more convenient because the network adapts itself to the user device. Experiments show that these advantages are obtained with negligible degradation in the throughput performance.