• Title/Summary/Keyword: 362 kV GIS

Search Result 23, Processing Time 0.034 seconds

Breakdown Characteristics of Dry Air under 362 kV GIB (362 kV GIB 내에서 건조공기의 절연파괴 특성)

  • Han, Ki-Son;Ju, Hyung-Jun;Yoon, Jin-Yul;You, Hong-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.10
    • /
    • pp.804-808
    • /
    • 2010
  • In this paper, we studied the dielectric breakdown voltage characteristics by the AC withstand voltage test on using green insulation dry air instead of $SF_6$ insulation gas used in the GIB (gas insulated bus) of 362 kV GIS (gas insulated switchgear). The AC withstand voltage test applied to the standard KEPCO's 362 kV GIB with dry air insulation, and the equivalence of dielectric breakdown voltage for dry air and $SF_6$ gas were examined, and the empirical formulas of dielectric breakdown voltage for dry air were calculated, and the criterion of AC withstand voltage test for dry air insulation was derived. Using the criterion, dry air can be used instead of $SF_6$ gas for 362 kV GIB in the factory acceptance test was confirmed.

3 Dimensional Electric Field Analysis for 362kv GIS and Analysis on the effect of particle attached on spacer (362kV GIS 차단부 3차원 전계해석 및 스페이서에 부착된 파티클의 영향 분석)

  • Ryu, Sung-Sic;Seok, Bok-Yeol;Lee, Hyeong-Goo;Kim, Yong-Han;Song, Tae-Hun;Choi, Young-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1773-1775
    • /
    • 2003
  • In this Study, the insulation safety for Closing Resistor and Disconnect Switch(DS) of 362kV GIS was estimated through 3 dimensional electric field analysis. In addition, the basic study to secure the electric insulation design technique was carried out through the research on the effect of a metallic particle which is generated in the GIS. As a result of 3 dimensional electric field analysis, it was found that the insulation capability of Closing Resistor and DS of 362kV GIS is stable electrically. Also, the fundamental data to improve the insulation capability of spacer was obtained by analyzing the maximum electric field according to the attached angle of a metallic particle which is attached on the surface of a spacer.

  • PDF

Investigation and Countermeasure of Sheath Circulating Current in the 362kV GIS (362kV GIS 외함 순환전류에 의한 접지본드 과열현상 및 대책)

  • Lee, J.H.;Kim, S.K.;Kim, S.T.;Shin, M.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.546-548
    • /
    • 2003
  • 본 논문에서는 362kV GIS 외함 유도 순환전류에 의한 접지본드과열에 대하여 원인을 분석하고 대책을 마련하는 것을 목적으로한다. 원인분석에는 접지본드 과열현상과 과열원인을 GIB 시스전류계산식을 이용하여 계산결과를 도출하였고 전자과도해석 프로그램(EMTP : Electromagnetic Transient Program)에 의한 분석을 통하여 원인을 분석하고 대책을 마련하여 과열현상을 방지하고자 한다.

  • PDF

The Development of 362kV Outdoor Composite Bushing For GIS (362kV GIS용 Outdoor Composite Bushing 개발)

  • Kim, Seong-Jung;Lee, Choonmee;Hong, Dongsuk
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.687-688
    • /
    • 2015
  • 기존의 Porcelain Bushing은 기계적 성능이 약하여 작은 충격에도 손상이나 파손 등이 발생되며 오손에 의한 전기적 성능의 저하로 오염이 심한지역에서의 사용이 제한되며 정기적으로 세정등 유지보수가 필요하다. 이러한 문제점을 보완하기 위해 절연성능 및 내 오손 특성이 우수한 Composite Bushing으로 바뀌고 있는 추세이다. 당사에서는 최근에 170kV GIS용 Composite Bushing 인증을 완료하였으며 본 논문에서는 362kV급 GIS용 Composite Bushing에 대한 개발 내용을 기술하였다.

  • PDF

Detection of partial discharge due to particle movement in the 302 kV gas-insulated switchgear structure using the UHF sensor (362 kV GIS 내부 이물질 운동에 의한 UHF 부분방전신호 검출)

  • Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.516-518
    • /
    • 2000
  • 정상 상태의 gas-insulated switchgear (CIS) 내부에서 발생한 부분방전 신호를 검출 할 수 있는 UHF 부분방전 검출 센서를 실험용 362 kV GIS에 적용하였다. GIS 내부에 알루미늄 이물질을 투입한 다음 120 - 180 kVrms 전압을 단계적으로 인가하고 장시간 인가전압 위상에 대한 UHF 부분방전 신호를 측정하였다. 인가전압을 높일수록 검출된 방전신호의 간격이 늘어났으며, 이물질로 사용한 알루미늄선의 길이가 길어질수록 이물질의 상승고도는 증가하였다. GIS 내부에서 이물질의 운동에 대한 간단한 계산에서도 비슷한 경향을 보임을 확인하였다.

  • PDF

Partial discharge Measurement on 362 kV GIS of Power Plant Switchyard (화력발전소 S/Y 362 kV GIS 부분방전 정밀측정)

  • Han, Ki-Seon;Yoon, Jin-Yul;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.143-145
    • /
    • 2007
  • 화력발전소 S/Y(switchyard)의 362 kV GIS에 대한 부분방전 정밀측정을 수행하였다. 2005년 부터 화력발전소 S/Y GIS의 고장예방을 위해 설치 운전승인 UHF 부분방전 상시감시시스템에서 상당히 큰 부분 방전신호가 지속적으로 감지되었다. 상시감시시스템에서 방전신호의 원인을 부유전극으로 추정하였으며, 이에 해당 사업소에서 감지된 방전신호의 노이즈 여부 및 방전 발생위치 추정을 위한 기술지원을 요청하였다. 이에 따라 전력연구원은 방전신호를 정밀 측정한 후 PRPD(phase resolved partial discharge) 분석을 통해 부유전극이 GIS 내부에 존재함을 확인하였으며, TOA(time of arrival)법에 의해 제 1 발전기 step-up 변압기부터 인근 가스절연모선 사이에 결함이 존재하는 것으로 추정하였다. 전력연구원의 측정결과를 바탕으로 발전소측에서 해당 개소를 분해 점검한 결과 가스절연모선의 중앙도체를 지지하는 supporting insulator 금구류의 접촉불량에 의한 부유전극 결함을 발견하고 보수하였다. 보수후 상시감시시스템에서 방전신호가 검출되지 않음에 따라 방전원인이 제거되었음을 확인하였다.

  • PDF

UHF Sensor Location Optimization for Partial Discharge Signals Detection Method (UHF 센서 위치 최적화로 부분방전 신호 검출 방법)

  • Choi, Mun-Gyu;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.409-413
    • /
    • 2014
  • GIS partial discharge that occurred in the UHF band signal is effectively detected by the method to IEC60270 5pc the apparent minimum discharge can be detected over the GIS arrangement of the sensor interior and exterior of the UHF in accordance with the optimized position signal by considering the damping ratio is selected so that the signals can be obtained to be mounted. 362kV, 800kV GIS is installed on the internal and external sensors are UHF band signal attenuation is set by measuring the reference value, but the operation, 170kV case 362kV, 800kV on the basis of the measurement data and to be installed and operated. When 170kV per 1Bay by installing the built-in sensor 1 for detecting a partial discharge signal, But, GIS signal attenuation is large in the case of an internal partial discharge signal is not detected in some cases. Where the attenuation is great UHF signal of the sensor by increasing the quantity of partial discharge signals were acquired to allow relocation. The greater the spacing between the sensor and the sensor is applied simplifies the installation and reduces the cost in terms of maintenance of appropriate optimal position is calculated to detect the partial discharge signal is needed. Thus 170kV GIS signal power attenuation of a partial discharge by measuring the UHF sensor, and by relocating the proper position is calculated in accordance with the sensor signal decay rate and minimize the error of omission in detecting a partial discharge signal was optimized.

The Study of The Calibration Method for The UHF PD Detection in GIS (GIS에서 UHF 부분방전 검출법의 교정방안 연구)

  • Lee, W.Y.;Chong, J.K.;Choi, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2290-2292
    • /
    • 1999
  • The Ultra-High Frequency(UHF) method for detecting a partial discharge in Gas-Insulated Substation(GIS) has some advantages compared to a conventional method(IEC 270) but there is a shortage in view of a quantitative analysis. Therefore, this paper describes the implementation of a calibrator and the calibration process based on it. And its characteristics are confirmed through the experiment using the 362kV GIS chamber.

  • PDF

A Study on the Development of LA Leakage Current Measuring-Equipment for 800kV GIS(2) (800kV GIS용 피뢰기 누설전류측정장치 개발에 관한 연구(2))

  • Kim, M.S.;Kim, J.B.;Song, W.P.;Kim, D.S.;Kil, G.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1739-1741
    • /
    • 2002
  • 본 논문에서는 현재 당사에서 GIS 제조업체로서 당사의 제품에 대한 예방진단 시스템을 구축한다는 계획의 일환으로서 진행하고 있는 신가평/신태백 765kV 변전소의 800kV/362kV GIS용 피뢰기 누설전류 측정장치 개발에 대한 전반적인 개요와 진행 상황에 대해서 기술하도록 한다. 우선, 피뢰기의 일반적인 열화 특성에 관해서 고찰하며, 개발된 피뢰기 누설전류측정장치의 시스템 구성도를 통해서 미소전류에 대한 신호처리기법을 소개한다. 또한, 본 장치를 개발함에 있어서 진행된 전자기 적합성(Electromagnetic Compatibility) 시험 및 절연 내력 시험에 대해서 서술하며, 시험 전, 후의 입 출력 특성을 확인함으로서 제품의 신뢰성을 검증하도록 하였다.

  • PDF

Parameter Selection of the Saturable Reactor for Removing Ferroresonance of 362kV Gas VT Using EMTP (EMTP를 이용한 362kV Gas VT의 철공진제거를 위한 가포화리엑터의 파라미터 선정)

  • Choi, Jae-Gu;Kim, Ik-Soo;Park, Kyoung-Won;Song, Hee-Suk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.4
    • /
    • pp.197-203
    • /
    • 2001
  • Recently, the construction of gas insulated substation(GIS)s has been increased in Korea. But, the whole quantity of the VTs which were used in GIS has been imported. Under the circumstance that $SF_6$ gas power apparatus are being developed up to 800kV rating in Korea, the development of EHV $SF_6$ gas VT is essential for localizing the power apparatus. As for EHV VT, destructive ferroresonance can be generated due to the combination of capacitiances between poles of circuit breaker, ground capacitance of bus and nonlinear excitation property of VT core. But the theoretical analysis about ferroresonance has not been fully achieved in Korea. Therefore, in this paper the authors would like to contribute for localizing EHV $SF_6$ gas VT by developing the diagram of ferroresonance zone according to the parameters of the circuit and the saturable reactor.

  • PDF