• Title/Summary/Keyword: 33-mode

Search Result 807, Processing Time 0.026 seconds

Efficient Intra Prediction Mode Decision Method using Integer Transform Coefficients for the Transcoding of MPEG-2 to H.264 Standard (MPEG-2에서 H.264로의 Transcoding 과정에서 정수 변환 계수를 이용한 효율적인 인트라 예측 모드 결정 방법)

  • Kim, Yong-Jae;Lee, Chang-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.12C
    • /
    • pp.1039-1045
    • /
    • 2008
  • The H.264/AVC video coding standard shows extremely higher coding efficiency, but it causes high computational complexity. Especially, the intra mode decision using the rate-distortion method requires many computations. Thus, the efficient intra mode decision methods have been proposed by decreasing the encoding complexity. In this paper, we propose an efficient intra mode decision algorithm using $4{\times}4$ integer transform coefficients in the conversion of MPEG-2 to H.264 standard. It is shown that the proposed algorithm reduces encoding time and complexity compared to the conventional algorithm, while showing similar PSNR performance.

Common-mode Voltage Reduction of Three Level Four Leg PWM Converter (3레벨 4레그 PWM 컨버터의 커먼 모드 전압 저감)

  • Chee, Seung-Jun;Ko, Sanggi;Kim, Hyeon-Sik;Sul, Seung-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.488-493
    • /
    • 2014
  • This paper presents a carrier-based pulse-width modulation(PWM) method for reducing the common-mode voltage of a three-level four-leg converter. The idea of the proposed PWM method is intuitive and easy to be implemented in digital signal processor-based converter control systems. On the basis of the analysis of space-vector PWM(SVPWM) and sinusoidal PWM(SPWM) switching patterns, the fourth leg pole voltage of the three-phase converter called "f leg pole voltage" is manipulated to reduce the common-mode voltage. To synthesize f leg pole voltage for the suppression of the common-mode voltage, positive and negative pole voltage references of f leg are calculated. An offset voltage is also deduced to prevent the distortion of a, b, and c phase voltages. The feasibility of the proposed PWM method is verified by simulation and experimental results. The common-mode voltage of the proposed PWM method in peak-to-peak value is 33% in comparison with that of the conventional SVPWM method. The transition number of the common-mode voltage is also reduced to 25%.

Evaluation of 119 emergency medical technicians' work related musculoskeletal disorders risk with regard to patient lifting procedures (119 구급대원의 업무관련성 근골격계 손상 위험성 평가 - 환자 들기 작업을 중심으로 -)

  • Son, Jeong-Won
    • The Korean Journal of Emergency Medical Services
    • /
    • v.23 no.1
    • /
    • pp.101-112
    • /
    • 2019
  • Purpose: The purpose of the study was to contribute to the prevention of musculoskeletal disorders (MSDs) in 119 emergency medical technicians (EMTs) by evaluating ergonomic risk factors of patient lifting work-postures. Methods: Four procedures were evaluated: using long back-board (LBB) on the sitting and standing main stretcher, using variable stretcher on the sitting and standing main stretcher. Wok-postures were assessed during training. Results: In using LBB on the sitting main stretcher, the OWAS-score was Mode:3 (Mean:2.30, Maximum:3), the REBA-score was Mode:9 (Mean:7.61, Maximum:11), requiring improvement soon. In using LBB on the standing main stretcher, the OWAS-score was Mode:3 (Mean:2.33, Maximum:3), requiring as soon as possible corrective action, the REBA-score was Mode:6 (Mean:5.44, Maximum:11), requiring improvement. In using variable stretcher on the sitting main stretcher, the OWAS-score was Mode:1 (Mean:1.85, Maximum:3), not requiring corrective action, the REBA-score was Mode:6 (Mean:6.78, Maximum:11), requiring improvement. In using variable stretcher on the standing main stretcher, the OWAS-score was Mode:3 (Mean:2.84, Maximum:3), requiring as soon as possible corrective action, the REBA-score was Mode:11 (Mean:9.38, Maximum:11), requiring immediate improvement. Conclusion: All four-procedures showed improvement in work-posture. Thereby, required attention and management in training, occupational health professionals should participate in change of lifting-method, and programs aimed at preventing MSDs should be developed and implemented in fire-academy and fire-station.

A Low Distortion and Low Dissipation Power Amplifier with Gate Bias Control Circuit for Digital/Analog Dual-Mode Cellular Phones

  • Maeng, Sung-Jae;Lee, Chang-Seok;Youn, Kwang-Jun;Kim, Hae-Cheon;Mun, Jae-Kyung;Lee, Jae-Jin;Pyun, Kwang-Eui
    • ETRI Journal
    • /
    • v.19 no.2
    • /
    • pp.35-47
    • /
    • 1997
  • A power amplifier operating at 3.3 V has been developed for CDMA/AMPS dual-mode cellular phones. It consists of linear GaAs power MESFET's, a new gate bias control circuit, and an output matching circuit which prevents the drain terminal of the second MESF from generating the harmonics. The relationship between the intermodulation distortion and the spectral regrowth of the power amplifier has been investigated with gate bias by using the two-tone test method and the adjacent channel leakage power ratio (ACPR) method of CDMA signals. The dissipation power of the power amplifier with a gate bias control circuit is minimized to below 1000 mW in the range of the low power levels while satisfying the ACPR of less than -26 dBc for CDMA mode. The ACPR of the power amplifier is measured to be -33 dBc at a high output power of 26 dBm.

  • PDF

Buck converter with new driving circuit in TV poer system (TV 전원장치에서 새로운 구동 회로에 의한 buck converter)

  • 정진국
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.3
    • /
    • pp.56-61
    • /
    • 1996
  • In this paper, new buck converter of a TV power system is presented. First, we devised a revised driving circuit for an emitter-coupled type buck converter, by which it is possible to reduce the material cost of transformers and voltage stress of power device. Secondly, we adopted a hybrid oscillation technique. When TV system is in off-stage, initial standby power which is necessary for remote controllable TV system is supplied by self-oscillating mode. Main power which is necessry in TV system bing on state is provided by an externally triggered oscillating mode. The switching frequency is synchronized to the oscillating frequency of horizontal deflection in TV, by which we can reduce picture noises and the size of power transformer. Thirdly, a simple error amplifier is inserted to the feed-back loop to keep the output voltage constant which means pulse width modulatio mode is added in driving part of power device. Finally, we showed by experiments that our proposed converter performs well enough to be close to the theoretically predicted values.

  • PDF

Trajectory of Resonant Displacement of Thickness Vibration Mode Piezoelectric Devices According to Diameter/Thickness Ratio (두께와 직경 비에 따른 두께진동모드 압전소자의 공진 변위 궤적)

  • Jeong, Yeong-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.2
    • /
    • pp.105-109
    • /
    • 2012
  • In this study, thickness vibration mode piezoelectric devices for AE sensor application were simulated using ATILA FEM program, and then fabricated. Trajectory resonant displacement and electro mechanical coupling factors of the piezoelectric devices were investigated. The simulation results showed that excellent displacement and electro mechanical coupling factor was obtained when the ratio of diameter/thickness($\Phi/T$) was 0.75. The piezoelectric device of $\Phi/T$=0.75 exhibited the optimum values of fr= 183 kHz, displacement= $4.44{\times}10^{-7}[m]$, $k_{33}$= 0.69, which were suitable for the application of AE sensor piezoelectric device.

Seismic Analysis on a Control Panel of (Nuclear) Power Plant (발전소 주 제어실 제어패널의 내진해석)

  • Lee, Heung-Shik;Kim, Myung-Gu;Cho, Chongdu
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.6 s.99
    • /
    • pp.652-659
    • /
    • 2005
  • In this paper, seismic qualification analysis for the Plant control Panel is carried out to confirm the structural integrity under the seismic conditions represented by required response spectra(RRS). The finite element method(FEM) is used for the analysis and a mode combination method is adopted to obtain a more reliable spectrum analysis results. In addition, the experimental analysis is performed to compare the reliability of the analytical results. The analysis results shows that the plant control panel system is designed to have the dynamic rigidity with no resonance frequency below 33 Hz. The analytically calculated maximum stress of the plant control panel system is $36\%$ of the field strength of material, thus it can be shown that the system has a stable structure for the seismic load.

An Experimental Study on The Improvement of Pattern Replication and Birefringence in LGP by Adding Compression Effects (압축효과를 가미한 도광판의 전사성과 복굴절 향상에 관한 실험적 연구)

  • Min I. K.;Kim J. S.;Ko Y. B.;Park H. P.;Yoon K. H.;Hwang C. J.
    • Transactions of Materials Processing
    • /
    • v.15 no.1 s.82
    • /
    • pp.27-33
    • /
    • 2006
  • It is necessary to improve the pattern replication and birefringence in LGP(Light guide panel) for better optical performance. In the present paper, the effects of injection-compression and injection-press mode with normal injection mold on the distribution of transcription of pattern and birefringence were studied. It was found that the values of pattern replication was improved and the birefringence was reduced for the cases of low initial clamping force in injection-compression mode and for the cases of longer mold opening length in injection-press mode, repectively.

Failure Mode Analysis for a Hyperbaric Oxygen Chamber (고압산소 치료기에 대한 고장모드 분석)

  • Jeon, Tae-Bo;Park, Seong-Bin
    • Journal of Industrial Technology
    • /
    • v.33 no.A
    • /
    • pp.9-14
    • /
    • 2013
  • Reliability plays a pivotal role in the development of medical instruments. A hyperbaric oxygen chamber, as a medical/health device, is known to help medical therapy for diversity of diseases through provision of high purity oxygen. The use of hyperbaric oxygen chamber is expected to increase in the future and study to examine reliability and safety is needed. We have performed reliability assessment for a newly developed hyperbaric oxygen chamber in this study. We first briefly discussed the system structure and mechanism. We then performed FMEA (Failure Mode and Effect Analysis) for the chamber. We drew major failure modes affecting the system performance and performed in depth analysis for measuring the expected effects.

  • PDF

Efficient Polling Scheme for Multiple Direct Link Communication Between STAs in Infrastructure Mode IEEE 802.11 Wireless LANs (Infrastructure Mode IEEE 802.11 무선랜 시스템에서 단말간의 다중 직접 통신을 위한 효율적인 폴링 방식)

  • Choi, Woo-Yong
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.33 no.2
    • /
    • pp.237-245
    • /
    • 2007
  • In this paper, a modified PCF (Point Coordination Function) MAC (Medium Access Control) Protocol is proposed to support the multiple direct link communication between STAs (STAtions) in infrastructure mode IEEE 802.11 wireless LANs. By the proposed MAC protocol, the direct link communication between STAs, which are located within the communication range of each other, is allowed without the use of AP (Access Point) as a relay. Moreover, when multiple direct data communication between STAs can be simultaneously performed with a sufficiently small interference, multiple simultaneous direct link communication is allowed for the efficient use of radio bandwidth. AP polls STAs to grant the transmission opportunities using the direct link communication by transmitting the polling frames to STAs. An efficient polling method for granting the transmission opportunities to STAs is proposed to reduce the number of the polling frame transmissions and enhance the PCF MAC performance.