• 제목/요약/키워드: 3. Surgery method

검색결과 3,248건 처리시간 0.021초

The effect of increasing the contact surface on tendon healing

  • Bilgen, Fatma;Duman, Yakup;Bulut, Omer;Bekerecioglu, Mehmet
    • Archives of Plastic Surgery
    • /
    • 제45권4호
    • /
    • pp.357-362
    • /
    • 2018
  • Background The most common complication after tendon repair is the development of adhesion, with subsequent rupture. Methods In this study, we present a new method in which the tendon healing contact surface is increased to reduce these complications. The tendons of chickens in groups 1, 3, and 5 were transversely cut and repaired with in the traditional fashion with double-modified Kessler method and 5/0 polypropylene. In the other groups, 3 mm of the tendon was removed from the proximal half of the upper end and from the distal half of the lower end of the tendon, and they were repaired with the modified Kessler method. The tendons of the chickens in groups 1 and 2 were evaluated immediatelly after surgery. Groups 3 and 4 were evaluated at 4 weeks after surgery. Groups 5 and 6 were evaluated at 6 weeks. Results Increases in transient inflammation and connective tissue formation were observed more clearly in the group treated with the new method in histopathological investigations at weeks 4 and 6. The stretching test showed statistically significant differences between groups 3 and 4 (P<0.05) and groups 5 and 6 (P<0.05). Conclusions When repairing tendons with the new method, the healing surface increases and the direction of collagen fibers at the surface changes. Because of these effects, the strength of the tendon healing line increases; we therefore expect that this technique will enable patients to safely engage in early active exercise after the operation, with less risk of tendon rupture.

로봇 수술을 위한 3차원 구조계산의 필요성 조사 (Research of 3D Information processing for Robot Surgery)

  • 정재은;최석윤
    • 대한디지털의료영상학회논문지
    • /
    • 제11권1호
    • /
    • pp.43-50
    • /
    • 2009
  • Geometry calculation Using Abdominal internal organ image from traditional laparoscopy or robotic surgery system we can make depth informations through measured 3D structure informations is very helpful to doctors, depth information is mare useful then others that use traditional laparoscopy or robotic surgery system to many doctors. however, traditional method are incomplete. less experienced doctors make much mare prohability of mistake. Hence, 3D information of organ is very helpful to the less experienced doctors. it will be greate role of reducing medical accidents and surgical time. We can get 3D informations using geometrical calculation method in robotic surgical system. also suggested method is needed in traditional surgical method without the need to create a new system, finally, We can get 3D information from traditional system without any new system, it take advantage in cost and create high efficiency. mare information will provided to many doctors.

  • PDF

Quantification of three-dimensional facial asymmetry for diagnosis and postoperative evaluation of orthognathic surgery

  • Cao, Hua-Lian;Kang, Moon-Ho;Lee, Jin-Yong;Park, Won-Jong;Choung, Han-Wool;Choung, Pill-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제42권
    • /
    • pp.17.1-17.11
    • /
    • 2020
  • Background: To evaluate the facial asymmetry, three-dimensional computed tomography (3D-CT) has been used widely. This study proposed a method to quantify facial asymmetry based on 3D-CT. Methods: The normal standard group consisted of twenty-five male subjects who had a balanced face and normal occlusion. Five anatomical landmarks were selected as reference points and ten anatomical landmarks were selected as measurement points to evaluate facial asymmetry. The formula of facial asymmetry index was designed by using the distances between the landmarks. The index value on a specific landmark indicated zero when the landmarks were located on the three-dimensional symmetric position. As the asymmetry of landmarks increased, the value of facial asymmetry index increased. For ten anatomical landmarks, the mean value of facial asymmetry index on each landmark was obtained in the normal standard group. Facial asymmetry index was applied to the patients who had undergone orthognathic surgery. Preoperative facial asymmetry and postoperative improvement were evaluated. Results: The reference facial asymmetry index on each landmark in the normal standard group was from 1.77 to 3.38. A polygonal chart was drawn to visualize the degree of asymmetry. In three patients who had undergone orthognathic surgery, it was checked that the method of facial asymmetry index showed the preoperative facial asymmetry and the postoperative improvement well. Conclusions: The current new facial asymmetry index could efficiently quantify the degree of facial asymmetry from 3D-CT. This method could be used as an evaluation standard for facial asymmetry analysis.

본 교실에서 시행한 악교정 수술 증례에 관한 임상적 연구 (CLINICOSTATISTICAL STUDY ON ORTHOGNATHIC SURGERY IN OUR DEPARTMENT)

  • 이상한;박인숙;이창환;권대근
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제31권3호
    • /
    • pp.255-259
    • /
    • 2005
  • We observed 469 cases (male 217 cases, female 252 cases) with dento-facial deformity for 10 years from Jan 1994 to Dec 2003. The ratio of male to female was 1:1.2 and the mean age was 23.3 years (male 24.0 years, female 22.6 years) ranged from 11 to 43 years. The most dominant group was related to mandibular prognathism (80.4%). A rate of 83.8% demonstrated mandibular protrusion according to Slavicek's classification (n=160), and 85.4% were classified as skeletal Class III type according to Sugawara's classification (n=151). Surgical method were divided into 355 cases of one jaw surgery (single method), 26 cases of one jaw surgery (combined method), and 77 cases of two jaw surgery. Sagittal split osteotomy were performed on 316 cases (69.0%). The average operation time and blood loss in SSRO were $4.1{\pm}2.2$ hrs. and $138.8{\pm}222.6$ ml (n=152).

Application of Patient-Specific 3D-Printed Orthopedic Splint for Bone Fracture in Small Breed Dogs

  • Kwangsik Jang;Eun Joo Jang;Yo Han Min;Kyung Mi Shim;Chunsik Bae;Seong Soo Kang;Se Eun Kim
    • 한국임상수의학회지
    • /
    • 제40권4호
    • /
    • pp.268-275
    • /
    • 2023
  • In this paper, we designed 3D-printed orthopedic splint models for patient-specific external coaptation on fracture healing and analyzed the stability of the models through finite element method (FEM) analysis under compressive load conditions. Polylactic acid (PLA) and acrylonitrile-butadiene-styrene (ABS) based 3D splint models of the thicknesses 1, 3, 5 and 7 mm were designed, and Peak von Mises stress (PVMS) and maximum displacement (MD) of the models were analyzed by FEM under compressive loads of 50, 100, 150, and 200 N. The FEM results indicated that PVMS and MD values, regardless of material, had a negative correlation with the thickness of the models and a positive correlation with the compressive load. There was a risk of splint deformation under conditions more extreme than 100 N with 5 mm thickness. For successful clinical application of 3D-printed orthopedic splints in veterinary medicine, it is recommended that the splint should be produced not less than 5 mm thickness. Also, it is expected to be stable when the splint is applied to situations with a compressive load of 100 N or less. There is an advantage of overcoming the limitations of the existing bandage method through 3D-printing technology as well as verifying the stability through 3D modeling before application. Such 3D printing technology will be widely used in veterinary medicine and various fields as well as orthopedics.

3D Face Modeling using Face Image

  • Kim, Sanghyuk;Ban, Yuseok;Park, Changhyun;Lee, Sangyoun
    • Journal of International Society for Simulation Surgery
    • /
    • 제2권1호
    • /
    • pp.10-12
    • /
    • 2015
  • Purpose It has been stated that patient satisfaction is the crucial factor for determining success in plastic surgery. The convergence of medical science and computer vision has made easier to satisfy patients who wants to have plastic surgery. In this paper, we try to apply 3D face modeling in plastic surgical area. Materials and Methods The author introduces a method for accurate 3D face modeling techniques using a statistical model-based 3D face modeling approach in a mirror system. Results We could successfully obtain highly accurate 3D face shape results. Conclusion The method suggested could be used for acquiring 3D face models from 2D face image and the result obtained from this could be effectively used for plastic surgical areas.

함몰흉 교정의 변형수기 (A Modified Technique for the Correction of Funnel Chest)

  • 이상호
    • Journal of Chest Surgery
    • /
    • 제33권10호
    • /
    • pp.806-811
    • /
    • 2000
  • Background : The authors have modified the method of Ravitch technique. Material and Method ; This technique was applied to 6 patients out of 18 patients who underwent corrective surgery from May 1987 to July 1999. The technique is quite different from that of Ravitch. We did not divide the intercostal muscle bundles from the laterals of sternum and the Akin's struts were placed retrosternally crossing the chest horizontally to prevent flail motion during immediate post-operative period and retraction of the sternum afterwards. Anterior sternal osteotomy instead of the posterior one was performed for the latest 3 cases which made operative procedure more simple and easy. The struts were removed one year later. Result : Compared to the hospital stay of the patients who received standard Ravitch method that of the six cases who received our modification was definitely shortened from 13.1 days to 8.3 days(p<0.0000). Flail motion was not noted in any patient and chest wall stability was obtained more easily with this technique. Conclusion : Our modification is recommendable for correction of funnel chest in regards to shorter operation time better chest wall stability shorter hospital stay and less complication.

  • PDF

유방축소술의 최근 경향 및 수직반흔법과 역T자반흔법의 비교 (Recent Trend of the Reduction Mammaplasty and comparing with Vertical Reduction Method and Inverted T-scar Method)

  • 권기현;임영빈;조명수;신혜경;설정현
    • Archives of Plastic Surgery
    • /
    • 제38권3호
    • /
    • pp.300-308
    • /
    • 2011
  • Purpose: The goal of reduction mammaplasty is breast with natural cone shape, minimizing scars, well-placed and sensate nipple-areolar area and maintaining breast physiology. In order to satisfy that goal, variable reduction mammaplasty methods are performed, however, two methods such as vertical reduction method and inverted T-scar method are currently most used. We compared indications and advantages of the two methods and set up useful guidlines. Methods: For 15 years from 1995 to 2010, we experienced 84 patients (162 breasts). We performed vertical reduction method as Lejour's superior pedicle technique (45 patients) and inverted T-scar method as Goldwyn's inferior dermal flap technique (39 patients). We evaluated the result of the operation comparing patient's age, amount of resected tissue, complications and post-operative scars of the two methods. Results: The mean age was 36 years and the vertical reduction group was 3 years younger than inverted T-scar group. The mean breast tissue resection amount per one breast, inverted T-scar group (712 gm) was lagger than vertical reduction group (395 gm). Conclusion: There is no ideal method for reduction mammaplasty until now. However, we suggest that guide line, the vertical reduction method is effective for minimal and moderate macromastia in young and middle aged women and inverted T-scar method is appropriate for severe macromastia with ptosis in elderly women. Recently, all procedures tried shorter and smaller scar on the vertical line as small I, J or L shape scar, and inframammary fold as short inverted T-scar.

3D CT를 이용한 교근의 부피측정 (Measurement Method of the Masseter Muscle Volume Using 3D Computed Tomography)

  • 백정환;최종우;유선국;김용욱;박병윤
    • Archives of Plastic Surgery
    • /
    • 제32권5호
    • /
    • pp.589-592
    • /
    • 2005
  • Since G.N. Hounsfield's clinical use of computed tomography in 1971, digital imaging technique using computers has shown an eye opening progress. Progress has made 3-dimensional understanding of not only facial bones but muscles and other connective tissues possible through 3-dimensional reconstruction of preexisting tomographical images. Also, quantitative analysis of density, distance, volume has become possible, allowing objective analysis of preoperative and postoperative states through imaging. The authors measured the masseter muscle volume of 20 normal individuals and 8 female patients through 3-D reconstructive CT imaging and made a statistical analysis of the measurements. The method used in our study may be applied to the diagnosis of disease causing the change of the facial volume and presurgical design as a useful tool to provide objective information on the evaluation of surgery outcome.