• Title/Summary/Keyword: 3-phase power

Search Result 3,121, Processing Time 0.033 seconds

H-Bridge VSC with a T-Connected Transformer for a 3-Phase 4- Wire Voltage and Frequency Controller of an Isolated Asynchronous Generator

  • Kasal, Gaurav Kumar;Singh, Bhim
    • Journal of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.43-50
    • /
    • 2009
  • This paper deals with a novel solid state controller (NSSC) for an isolated asynchronous generator (IAG) feeding 3-phase 4-wire loads driven by constant power prime movers, such as uncontrolled pico hydro turbines. AC capacitor banks are used to meet the reactive power requirement of the asynchronous generator. The proposed NSSC is realized using a set of IGBTs (Insulated gate bipolar junction transistors) based current controlled 2-leg voltage source converters (CC- VSC) and a DC chopper at its DC bus, which keeps the generated voltage and frequency constant in spite of changes in consumer loads. The neutral point of the load is created using aT-configuration of the transformers. The IAG system is modeled in MATLAB along with Simulink and PSB (power system block set) toolboxes. The simulated results are presented to demonstrate the capability of the isolated generating system consisting of NSSC and IAG driven by uncontrolled pico hydro turbine and feeding 3-phase 4-wire loads.

The Harmonics and Reactive Power Compensation with Series Active Power filter in 3-phase 4-wire System (3상 4선식 전력시스템에서 직렬형 능동필터에 의한 고조파전류와 무효전력 보상에 관한 연구)

  • Kim, Jin-Sun;Kim, Young-Jo;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1072-1074
    • /
    • 2003
  • In this paper, a new control strategy of a series active power filter using direct compensating voltage extraction method is proposed. This control algorithm compensates harmonics, reactive power and neutral line currents which are generated by balanced or unbalanced nonlinear loads. The advantage of this method is that the compensating voltage of the series active power filter can be extracted without phase transformation. Therefore, calculation time is shorten and the control method is simple compared with conventional method as the p-q theory In addition, this control strategy was applied for the series active power filter in 3-phase 4-wire system which is widely employed in distributing electric energy to several office building and manufacturing plants. Some results obtained from the experimental model using the proposed method are presented to demonstrate and confirm its validity.

  • PDF

Power Spectrum of Two-Phase and Three-Phase RCD-PWM Scheme for Switching Noise Reduction of Induction Motors (유도모터의 스위칭 소음저감을 위한 2상 및 3상 RCD-PWM기법의 파워 스펙트럼)

  • 위석오;정영국;임영철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.178-186
    • /
    • 2004
  • This paper proposes a two-phase RCD-PWM scheme which is much better than a three-phase RCD-PWM scheme from the standpoint of the broadening and linearizing effect of the power spectrum. To implement the proposed scheme and conventional scheme, the experiment based on the SAB-Cl67 micro-controller was executed. Based on the space vector modulation technique, the duty ratio of the pulses is calculated using the SAB-Cl67 and each of PWM pulses is located randomly in each switching interval. The power spectrum of the output voltage, output current, the d.c link current and the acoustic noise radiated from inverter drives are experimentally investigated. 1'hen, the performance of the proposed scheme was compared and discussed with the conventional scheme.

3-Phase and 2-Phase Modulated SRP-PWM Technique with a Fixed Frequency for Power Electronics Converters (전력전자 변환장치를 위한 고정 스위칭 주파수로 동작하는 3상 및 2상 변조 SRP-PWM기법)

  • Oh S. Y.;Jung Y. G.;Lim Y. C.;Wi S. O.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.397-401
    • /
    • 2004
  • In this paper, Inverter drives adopting 3-phase and 2-phase SRP-PWM (Separately Randomized Pulse Position PWM) with fixed switching frequency is proposed. In the proposed SRP-PWM scheme, each of 3 or 2 phase pulses Is located randomly in each switching interval. The experimental results show that the voltage / current harmonics and the switching noise harmonics are spread to a wide band area. Also, the performance of the 3-phase SRP-PWM and the 2-phase SRP-PWM are compared to each other. In result, the speed response is nearly similar to each other from the viewpoint of the v/f constant control.

  • PDF

Configurations of High Power VSI Drives for Traction Applications Using Multi Level Inverters and Multi Phase Induction Motors (멀티레벨 인버터와 다상 유도기를 이용한 견인기용 대전력 VSI의 구조와 특성)

  • Gopakumnr, K.;Ryu, Hong-Je;Kim, Jong-Su;Im, Geun-Hui
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.500-504
    • /
    • 1997
  • Current source inverter drives of auto sequentially commutated type are very popular in high power applications, because of simple power circuit configuration with four quadrant operation. But the six-step current output create harmonic problems and the input power factor of such a drive is not always good. In this respect pulse width modulated drives using gate turn off thyristors ( GTO ) are finding application, especially in traction drives. However the switching and snubber loses of a GTO do not permit the inverter switching frequency go beyond a few hundred hertz.This will again introduce low frequency harmonic problems. Multi level inverters of the 3-level and 5-level can be considered as an alternative to overcome the low switching frequency harmonic problem of the 2-level GTO inverters. But with multi level inverters the complexity of the power circuit increases. In this paper a combination of multi level ( 2-level and 3-level ) inverters and multi phase induction motor ( 3-phase and 6-phase) configurations are presented for high power VSI drives for traction applications with reduced inverter switching frequency requirements coupled with reduced voltage rating for the power switch.

  • PDF

A Study on Device Development for Electrical Fire Protection on Open Phase of Three-Phase Motor (3상 전동기 결상에 의한 전기화재 보호를 위한 장치 개발 연구)

  • Choi, Shin-Hyeong;Kwak, Dong-Kurl;Kim, Jin-Hwan
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.61-67
    • /
    • 2012
  • In the three-phase power system using the three-phase motor, when any one-phase is open-phase, the unbalanced current flows and the single-phase power supplied by power supply produces overcurrent to motor coil. As a result, the enormous damage and electrical fire can be given to the power system. Recently, the thermal over-current relay (THR) or electronic motor protection relay (EMPR) is mostly used as the open-phase detection device of the three-phase motor. When the over-current or overheat of electric line is generated, it detects and operates circuit breaker, but there is the defect that the sensing speed is slow, the operation can be sometimes failed, and the precision is decreased. In order to improve these problems, this paper is proposed a new control circuit topology for openphase protection using semiconductor devices. Therefore, the proposed open-phase protection device (OPPD) enhances the sensing speed and precision, and has the advantage of simple fitting in the three-phase motor control panel in the field, as it manufactures into small size and light weight. As a result, the proposed OPPD protects the three-phase motor, minimizes the electrical fire from openphase, and contributes for the stable driving of the power system. The performance and confidence of the proposed OPPD is confirmed by a great variety of the experiments of operation characteristic.

A Grid Current-Controlling Shunt Active Power Filter

  • Tumbelaka, Hanny H.;Borle, Lawrence J.;Nayar, Chemmangot V.;Lee, Seong-Ryong
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.365-376
    • /
    • 2009
  • In this paper, the implementation of a three-phase shunt active power filter is presented. The filter is essentially three independent single-phase current-controlled voltage source inverters (CC-VSI) with a common DC bus. The CC- VSI is operated to directly control the AC grid current to be sinusoidal and in phase with the grid voltage without detecting the load currents. The APF consists of a current control loop, which shapes the grid currents to be sinusoidal and a voltage control loop, which regulates the active power balance of the system. The experimental results indicate that the active filter is able to handle predominantly the harmonics, as well as the unbalance and reactive power, so that the grid currents are sinusoidal, in phase with the grid voltages and symmetrical.

Study on Leading-phase Operation Capability of a 770 MW Jumbo Hydro-generator based on Stability Analysis and End-Region Heat Analysis

  • Fan, Zhen-nan;Zhou, Zhi-ting;Li, Jian-fu;Wen, Kun;Wang, Jun;Sun, Zhang;Wang, Tao;Yao, Bing
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1317-1325
    • /
    • 2018
  • A generator-grid coupling calculation model is established to study the leading-phase operational capability of a 770 MW jumbo hydro-generator in a Chinese ultra-mega hydropower station. The static and dynamic stability of the generator are analyzed and calculated to obtain stability limits under leading-phase operating conditions. Three-dimensional (3D) time-varying nonlinear moving electromagnetic and temperature field models of the generator end-region are also established and used to determine the magnetic field, loss, and temperature of the end-region under the leading-phase operating condition. The simulation results agree with data measured from the actual 770 MW hydro-generator. This paper provides reliable reference data for the leading-phase operation of a jumbo hydro-generator, which will help to improve in the design and manufacture of future hydro-generators.

The Study on Highly Miniaturized Active 90°C Phase Difference Power Divider and Combiner for Application to Wireless Communication (무선 통신 시스템 응용을 위한 초소형화된 능동형 90°C 위상차 전력 분배기와 결합기에 관한 연구)

  • Park, Young-Bae;Kang, Suk-Youb;Yun, Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.1
    • /
    • pp.144-152
    • /
    • 2009
  • This paper propose highly miniaturized active $90^{\circ}C$ phase difference power divider and combiner for application to wireless communication system. The conventional passive $90^{\circ}C$ power divider and combiner cannot be integrated on MMIC because of their very large circuit size. Therefore, the highly miniaturized active $90^{\circ}C$ phase difference power divider and combiner are required for a development of highly integrated MMIC. In this paper, the highly miniaturized active $90^{\circ}C$ phase difference power divider and combiner employing InGaAs/GaAs HBT were designed, fabricated on GaAs substrate. According to the results, the circuit size of fabricated active $90^{\circ}C$ phase difference power divider and combiner were $1.67{\times}0.87$ mm and $2.42{\times}1.05$ mm, respectively, which were 31.6% and 2.2% of the size of conventional passive branch-line coupler. The output gain division characteristic of proposed divider circuit showed 8.4 dB and 7.9 dB respectively, and output phase difference characteristic showed $-89.3^{\circ}C$. The output gain coupling characteristic of proposed combiner circuit showed 9.4 dB and 10.5 dB respectively, and output phase difference characteristic showed $-92.6^{\circ}C$. The highly miniaturized active $90^{\circ}C$ phase difference power divider and combiner exhibited good RF performances compared with the conventional passive branch-line coupler.

A Low COST SOFT-SWITCHED AC-TO-TC CONVERTER

  • 최주엽;목형수;김택용
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.135-140
    • /
    • 1997
  • A highly efficient single-phase/three-phase compatible ac-to-dc converter is proposed and analyzed, which includes three identical single-phase both soft-switched dc-to-dc converter with boost converter as a pre-regulator for input power factor correction (PFC). The proposed converter structure provides a cost reduction and easy implementation of compatibility between single-phase 220V and three-phase 220V/380V with their inputs in delta or wye connections.

  • PDF