• 제목/요약/키워드: 3-phase power

검색결과 3,127건 처리시간 0.029초

Investigation of Terahertz Generation from Bulk and Periodically Poled LiTaO3 Crystal with a Cherenkov Phase Matching Scheme

  • Li, Zhongyang;Bing, Pibin;Yuan, Sheng;Xu, Degang;Yao, Jianquan
    • Journal of the Optical Society of Korea
    • /
    • 제19권3호
    • /
    • pp.297-302
    • /
    • 2015
  • Terahertz (THz) wave generation from bulk and periodically poled $LiTaO_3$ (PPLT) with a Cherenkov phase matching scheme is numerically investigated. It is shown that by using the crystal birefringence of bulk $LiTaO_3$ and a grating vector of PPLT, THz waves can be efficiently generated by difference frequency generation (DFG) with a Cherenkov phase matching scheme. The frequency tuning characteristics of the THz wave via varying wavelength of difference frequency waves, phase matching angle, poling period of PPLT and working temperature are theoretically analyzed. The parametric gain coefficient in the low-loss limit and the absorption coefficient of the THz wave during the DFG process in the vicinity of polariton resonances are numerically analyzed. A THz wave can be efficiently generated by utilizing the giant second order nonlinearities of $LiTaO_3$ in the vicinity of polariton resonances.

Performance Evaluation of the Field-Oriented Control of Star-Connected 3-Phase Induction Motor Drives under Stator Winding Open-Circuit Faults

  • Jannati, Mohammad;Idris, Nik Rumzi Nik;Aziz, Mohd Junaidi Abdul
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.982-993
    • /
    • 2016
  • A method for the fault-tolerant vector control of star-connected 3-phase Induction Motor (IM) drive systems based on Field-Oriented Control (FOC) is proposed in this paper. This method enables the control of a 3-phase IM in the presence of an open-phase failure in one of its phases without the need for control structure changes to the conventional FOC algorithm. The proposed drive system significantly reduces the speed and torque pulsations caused by an open-phase fault in the stator windings. The performance of the proposed method was verified using MATLAB (M-File) simulation as well experimental tests on a 1.5kW 3-phase IM drive system. This paper experimentally compares the operation of the proposed fault-tolerant vector controller and a conventional vector controller during open-phase fault.

해상실험을 통한 저전력 수중음향통신 기법의 성능 분석 (Performance Analysis of the Underwater Acoustic Communication with Low Power Consumption by Sea Trials)

  • 이태진;김기만
    • 한국항해항만학회지
    • /
    • 제35권10호
    • /
    • pp.811-816
    • /
    • 2011
  • 이 논문에서는 저전력 통신 기법 가운데 하나인 PSPM(Phase Shift Pulse position Modulation) 전송 기법이 근거리 수중음향 채널에서 어떠한 성능을 나타낼지 고찰하기 위해 해상실험을 통해 분석하였다. PSPM은 QPSK(Quadrature Phase Shift Keying)와 PPM(Pulse Position Modulation) 기법을 서로 혼합한 형태로 WBAN(Wireless Body Area Network) 시스템에서 저전력 통신을 위해 제안된 기법이다. 이는 기존의 일반적인 전송 방식에 비해 대역효율은 떨어지지만 전력효율은 증가하는 것으로 알려져 있다. 이 논문에서는 실해역에서 취득한 PSPM 데이터를 통해 BER 성능을 분석한다. 실험 결과 QPSK의 경우 총 56,000개의 전송 데이터 비트 중 오차 비트 수가 3,384개로 BER이 약 $6.04{\times}10^{-2}$이고, PSPM의 경우는 19,652개로 BER이 약 $3.5{\times}10^{-1}$를 얻었다. 또한 영상 데이터 전송에 따른 PSNR(Peak signal-to-noise ratio)을 비교한 결과 QPSK의 경우 9.37 dB 였으며, PSPM의 경우 9.11 dB 였다.

154 kV 3상 전력 케이블의 상호작용에 따른 금속 Sheath에서 발생하는 와전류 손실 분석 (Analysis of Eddy Current Loss Considering Interaction Effect in Metal Sheath of 154 kV Three Phase Power Cable)

  • 임상현;김기병;박관수
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권4호
    • /
    • pp.389-392
    • /
    • 2020
  • 전력 케이블에서 발생하는 손실을 정확히 예측하기 위해서는 금속 시스에서 발생하는 와전류 손실에 대한 분석이 필요하다. 동손의 경우 도체의 저항과 전류에 의하여 쉽게 계산이 되지만 금속 시스에서 발생하는 와전류의 경우 측정 및 예측이 어렵기 때문이다. 이를 위하여 선행연구에서는 단상 케이블에서 발생하는 와전류 손실을 분석하였지만 실제 환경에서는 3상이 대부분 사용되기 때문에 적용하기에는 한계가 존재한다. 그러므로 본 논문에서는 3상 케이블의 금속 시스에서 발생하는 와전류 손실에 대하여 발생 원인에 따라 이론적으로 분석하고 전자기 수치 해석을 통하여 삼각 배열과 수평배열에서 발생하는 와전류 손실을 예측하였다.

3상 교류전원 LED 램프의 광 플리커 (Light Flicker of Three-Phase AC-powered LED Lamp)

  • 이동원;김병철
    • 한국전기전자재료학회논문지
    • /
    • 제27권4호
    • /
    • pp.262-267
    • /
    • 2014
  • This study describes that light flicker of LED lamp is improved by placing an AC-powered LED block in each phase of three-phase AC power. Rectified current is considered as an instantaneous luminous flux because the current flowing through the LED block is proportional to the amount of light emitted by the LED block. Percent flicker is calculated simply by modeling the rectified current flowing through the LED block to a triangular wave current. Percent flicker is 100% in single-phase AC powered LED lamp. Percent flicker of the same level as that in an incandescent lamp (6%~14%) is however, achieved if light emission starts before $40^{\circ}$ in each voltage phase of three-phase AC power.

산업현장 정전 및 결상사고 감지회로 토폴로지 연구 (A Study on Circuit Topology for the Electrical Power Failure and Open-Phase Fault Detection of Industrial Field)

  • 박동훈;곽동걸;정회중;전호진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.540-542
    • /
    • 2019
  • This paper proposes an open-phase fault control system using 3-phase neutral voltage. The proposed control system is designed as a new topology which uses the potential difference between neutral point and ground of three phase. The open-phase detection system is also configured to Y-wiring of three capacitance devices of the same capacity to each line of three phase power source R-S-T. This paper also designs a mobile phone application for remote alarm of open-phase fault.

  • PDF

선간전압과 상전압에 대한 전압불평형율의 비교 (Comparison of Voltage Unbalance Factor for Line and Phase Voltage)

  • 김종겸;박영진;이은웅
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권9호
    • /
    • pp.403-407
    • /
    • 2005
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, voltage unbalance is generated at the user's 3-phase 4-wire distribution systems with single & three phase. Voltage unbalance is mainly affected by load system rather than power system. Unbalanced voltage will draws a highly unbalanced current and results in the temperature rise and the low output characteristics at the machine. It is necessary to analyse correct voltage unbalance factor for reduction of side effects in the industrial sites. Voltage unbalance is usually defined by the maximum percent deviation of voltages from their average value, by the method of symmetric components or by the expression in a more user-friendly form which requires only the three line voltage readings. If the neutral point is moved by the unbalanced load at the 3-phase 4-wire system. Line and phase voltage unbalance leads to different results due to zero-sequence component. So that it is difficult to analyse voltage unbalance factor by the conventional analytical method, This paper presents a new analytical method for phase and line voltage unbalance factor in 4-wire systems. Two methods indicate exact results.

3상 계통연계 태양광발전시스템의 운전특성 (Control Characteristics of Three-Phase Utility Interactive Phovotovoltaic Power Generation System)

  • 김영철;정명웅;서기영;이현우;우준인
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권8호
    • /
    • pp.536-543
    • /
    • 2000
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three-phase inverter is used for the connection between the photovoltaic array and the utility. This paper present a three phase inverter for photovoltaic power system with current controller, voltage controller, PLL Control system and the Phase detector of Interactive Voltage by using dq transformation. The proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor.

  • PDF

3상 변압기를 이용한 고밀도 양방향 전력변환기 (Three-Phase High-Power-Density Bidirectional DC-DC Converter)

  • 레동부;최우석;김선필;박성준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.45-46
    • /
    • 2014
  • This paper presents a three-phase high-power-density bidirectional DC-DC converter. The converter employs dual three-phase active bridges and a three-phase transformer. The presented converter is controlled by two symmetric PWM modules and phase between two symmetric PWM modules to control the power flow. Simulation is included to verify the presented converter.

  • PDF

Deadbeat Direct Active and Reactive Power Control of Three-phase PWM AC/DC Converters

  • Gandomkar, Ali;Seok, Jul-Ki
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1634-1641
    • /
    • 2018
  • This study focuses on a high-performance direct active and reactive power controller design that is successfully applicable to three-phase pulse width modulation (PWM) AC/DC converters used in renewable distributed energy generation systems. The proposed controller can overcome the sluggish transient dynamic response of conventional controllers to rapid power command changes. Desired active and reactive powers can be thoroughly obtained at the end of each PWM period through a deadbeat solution. The proposed controller achieves an exact nonlinear cross-coupling decoupling of system power without using a predefined switching table or bang/bang hysteresis control. A graphical and analytical analysis that naturally leads to a control voltage vector selection is provided to confirm the finding. The proposed control strategy is evaluated on a 3 kW PWM AC/DC converter in the simulation and experiment.