• Title/Summary/Keyword: 3-phase Transformer

Search Result 310, Processing Time 0.025 seconds

Analysis of Transient Characteristics of a SFCL Applied Into Third-winding Transformer in a Single Line-to-ground Fault (1선 지락 사고 시 3 권선 변압기에 적용된 초전도 한류기의 동작 특성 분석)

  • Choi, Hye-Won;Choi, Hyo-Sang;Jung, Byung-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.1033-1037
    • /
    • 2013
  • Coercion transformer is commonly used in the electrical grid which in three phase of distribution system. The accident of the electrical grid is divided into a single, a double, a third line-to-ground faults and a double, a third line-to-line faults. A single line-to-ground fault accounts for nearly 75[%] among them. In this research, when a Superconducting Fault Current Limiters (SFCL) was applied to the three phase power system, operation in a single line-to-ground fault and limiting characteristics of fault current according to turns ratio of third winding were analyzed. When a single line-to-ground fault happened, secondary winding's circuit was open. Then third winding's circuit with a SFCL was closed. So fault current was limited by diverted circuit. At this time, we could find out that size of the limited fault current could be changed according to third winding rate. We confirmed that limiting operation of the fault current was carried out within one-period. These results will be utilized in adjusting the size of the SFCL.

Vertical Integrated Transformer using Bondwires (본딩와이어를 이용한 수직형 집적 트랜스포머)

  • Song, Byeong-Uk;Lee, Hae-Yeong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.3
    • /
    • pp.43-48
    • /
    • 2000
  • In this paper, vortical integrated transformers using bondwires are proposed and characterized for MMIC's (Monolithic Microwave Integrated Circuits) In a wide range of frequencies (1∼20 GHz), where full-wave analysis by the FEM (Finite Element Method) was adopted. The electrical characteristics of the proposed transformers are compared with those of the spiral transformer. We extracted mutual inductances from S -parameters. The vertical transformers using bondwires have not only low insertion loss but also reduce parasitic capacitances and dielectric loss due to their separation from substrates. It can be fabricated easily by used of the modern automatic wirebonding technology. It is expected that the proposed transformers are to improve the performance of MMIC's applied to impedance matching, and phase shifting circuits.

  • PDF

A High Power ZVS Push-Pull Converter by Optimized Design of Three-Phase High Frequency Transformer (3상 고주파 변압기 최적 설계에 의한 대전력 ZVS 푸쉬풀 컨버터)

  • Park, Jun-Sung;Lee, Sang-Won;Choi, Se-Wan
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.135-137
    • /
    • 2010
  • 본 논문에서는 고승압 대전력 3상 DC-DC 컨버터의 핵심부품인 3상 고주파변압기를 상용 EI코아를 이용하여 설계한 방법을 제시한다. 제안한 설계방법은 부피 및 자화인덕턴스 등 불균형 요소를 최소화하고 진동에도 우수한 구조를 갖는다. 5kW급의 시작품으로부터 제안한 컨버터의 타당성 및 성능을 검증한다.

  • PDF

A study on the composition of piezoelectric ceramic for high-power piezoelectric transformer (고출력 압전 변압기용 압전 세라믹의 조성에 관한 연구)

  • Lee, Jong-Pil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.390-395
    • /
    • 2011
  • In order to develope piezoelectric transformer for the ballast of fluorescent lamp, the composition of piezoelectric ceramics was 0.95Pb($Zr_xTi_{1-x}$)O3+yPb($Mn_{1/3}Nb_{2/3}$)$O_3$+(0.05-y)Pb($Sb_{1/2}Nb_{1/2}$)$O_3$. PMN compound was selected to improve mechanical quality factor and PSN to prevent the decrease of dielectric constant and electromechanical coupling coefficient. Dielectric and piezoelectric characteristics in the region of MPB of 0.95Pb($Zr_xTi_{1-x}$)$O_3$+yPb($Mn_{1/3}Nb_{2/3}$)$O_3$+(0.05-y)Pb($Sb_{1/2}Nb_{1/2}$)$O_3$ ceramics was discussed both quantatively and qualitatively.

Current-induced Phase Demodulation Using a PWM Sampling for a Fiber-optic CT

  • Park, Hyoung-Jun;Lee, June-Ho;Kim, Hyun-Jin;Song, Min-Ho
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.240-244
    • /
    • 2010
  • In this work, we used PWM sampling for demodulation of a fiber-optic interferometric current transformer. The interference signal from a fiber-optic CT is sampled with PWM triggers that produce a 90-degree phase difference between two consecutively sampled signals. The current-induced phase is extracted by applying an arctangent demodulation and a phase unwrapping algorithm to the sampled signals. From experiments using the proposed demodulation, we obtained phase measurement accuracy and a linearity error, in AC current measurements, of ~2.35 mrad and 0.18%, respectively. The accuracy of the proposed method was compared with that of a lock-in amplifier demodulation, which showed only 0.36% difference. To compare the birefringence effects of different fiber-optic sensor coils, a flint glass fiber and a standard single-mode fiber were used under the same conditions. The flint glass fiber coil with a Faraday rotator mirror showed the best performance. Because of the simple hardware structure and signal processing, the proposed demodulation would be suitable for low-cost over-current monitoring in high voltage power systems.

Study about Power Transformer and Lines Tracing Method based on Power Line Communication Technology (전력선 통신 기술을 활용한 변압기 및 전력선로 추적 방법 개발에 관한 연구)

  • Byun, Hee-Jung;Choi, Sang-jun;Shon, Sugoog
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.505-508
    • /
    • 2016
  • In city, tracing of power transmission lines is difficult due to compound installation of overhead and underground lines, transposition, bad view caused by trees or big buildings. It is hard problem for electrical technician on site to trace power transformers or power lines to serve customers in 3 phase -4 wires power distribution systems. It is necessary that the correct and fast tracing method is required for load balancing among distribution lines. Old technology use to trace lines with high power impulse injection. Our proposed method uses to trace lines with very small power high frequency signal injection. Simulation models for 3-phase power transformers, 3-phase wire lines, and customer loads are described to investigate the transmission characteristics of high frequency power line carrier. Distribution lines have only a limited ability to carry higher frequencies. Typically power transformers in the distribution system prevent propagating the higher frequency carrier signal. The proposed method uses the limited propagation ability to identify the power transformer to serve customers. The system consists of a transmitter and a receiver with power-line communication module. Some experiments are conducted to verify the theoretical concepts in a big commercial building. Also some simulations are done to help and understand the concepts by using MATLAB Simulink simulator.

  • PDF

Iron Core Design of 3-Phase 40MVA HTS Power Transformer Considering Voltages per Turn

  • Lee, Chan-joo;Seok, Bok-yeol
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.2
    • /
    • pp.54-58
    • /
    • 2004
  • This paper presents the iron core design method of a high temperature superconducting (HTS) transformer considering voltages per turn (V/T). In this research, solenoid type HTS coils were selected for low voltage (LV) winding and double pancake coils for high voltage (HV) winding, just as in conventional large power transformers. V/T is one of the most fundamental elements used in designing transformers, as it decides the core cross sectional area and the number of primary and secondary winding turns. By controlling the V/T, the core dimension and core loss can be changed diversely. The leakage flux is another serious consideration in core design. The magnetic field perpendicular to the HTS wire causes its critical current to fall rapidly as the magnitude of the field increases slowly. Therefore in the design of iron core as well as superconducting windings, contemplation of leakage flux should be preceded. In this paper, the relationship between the V/T and core loss was observed and also, through computational calculations, the leakage magnetic fields perpendicular to the windings were found and their critical current decrement effects were considered in relation to the core design. The % impedance was calculated by way of the numerical method. Finally, various models were suggested.

Accident Risk Assessment between Power Cable Head and Safety Shutter in Medium Voltage Metal-Clad Switchgear (고압폐쇄분전반의 전력케이블 헤드와 안전셔터에서의 사고위험 평가)

  • Shong, Kil-Mok;Han, Woon-Ki;Kim, Young-Seok
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.264-267
    • /
    • 2006
  • This paper describes the accident analysis by modeling the current transformer mounting in meaium voltage metal-clad switchgear(MCSG). In analyzing the accident the reconstruction at the current transformer mounting(VCB connecting guide) has to be taken into account. The accident was modelled as a 3-phase ground fault mounting between the end plate of a high voltage lines and the safety shutter at the current transformer mounting of the VCB inside the metal clad switchgear. Since the outside maintenance of the metal clad switchgear is restricted by the enclosed compartments, its circumference has to be kept clean. Through the reconstruction results, it was confirmed that the fault of the enclosed switchboard could be reduced when the shutter made of Fe material was changed into an insulation.

  • PDF

The Study of Sintering Behavior and Piezoelectric Properties in $Pd_{(1-x)}$$Cd_x$[(Mn, Sb), Zr, $Ti]O_3$ Ceramics ($Pd_{(1-x)}$$Cd_x$[(Mn, Sb), Zr, $Ti]O_3$ 세라믹스의 소결 거동 및 압전 특성에 대한 연구)

  • 나은상;최성철
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.4
    • /
    • pp.395-401
    • /
    • 2000
  • In this study, we chose the basic composition which indicated the best electrical properties by change of x content(0, 0.05, 0.1, 0.15, 0.2, 0.25 mol respectively) in xPb(Mn1/3Sb2/3)O3-(1-x)Pb(Zr0.52Ti0.48)O3 ceramics. And we substituted Cd2+ for Pb2+ site, then observed the sintering behavior, microstructure and electrical propertties according to the various sintering temperature. The basic composition was the 0.05PMS-0.95PZt, and it showed single perovskite phase and excellent properties. In case of Cd2+ substitution, we were able to sinter at 90$0^{\circ}C$ which was lower than conventional sintering temperature(1200~130$0^{\circ}C$). Especially, when the 2mol% substituted PMS-PZT specimens were sintered at 90$0^{\circ}C$ for 2h, we obtained the p=7.6g/㎤, kp=56%, Qm=520 and made sure of a position of Cd2+ substitution by observing lattice parameter, phase transition temperature. From this results, we could infer that because Cd2+ substituted fro A-site, low temperature sintering of Cd2+ substituted PMS-PZT without any loss of electrical properties shows its applicability for the piezoelectric ceramic transformer.

  • PDF

Design and Fabrication of an Electronic Voltage Transformer (EVT) Embedded in a Spacer of Gas Insulated Switchgears (가스절연개폐장치의 스페이서 내장형 전자식 변압기의 설계 및 제작)

  • Lim, Seung-Hyun;Kim, Nam-Hoon;Kim, Dong-Eon;Kim, Seon-Gyu;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.4
    • /
    • pp.353-358
    • /
    • 2022
  • Bulky iron-core potential transformers (PT) are installed in a tank of gas insulated switchgears (GIS) for a system voltage measurement in power substations. In this paper, we studied an electronic voltage transformer (EVT) embedded in a spacer for miniaturization, eco-friendliness, and performance improvement of GIS. The prototype EVT consists of a capacitive probe (CP) that can be embedded in a spacer and a voltage Follower with a high input and a low output impedance. The CP was fabricated in the form of a Flexible-PCB to acquire the insulation performance and to withstand vibration and shock during operation. Voltage ratio of the prototype EVT is about 42,270, and the frequency bandwidth of -3 dB ranges from 0.33 Hz to 3.9 MHz. The voltage ratio error evaluated at about 6%, 12% and 18% of the rated voltage of 170 kV was 0.32%, and the phase error was 12.9 minutes. These results were within the accuracy for the class 0.5 specified in IEC 60044-7 and satisfy even in ranges from 80% to 120% of the rated voltage. If the prototype EVT replaces the conventional iron-core potential transformer, it is expected that the height of the GIS could be reduced by 11% and the amount of SF6 will be reduced by at least 10%.