• 제목/요약/키워드: 3-phase AC-DC converter

검색결과 181건 처리시간 0.028초

고역률, 고효율 충.방전기 (Charging-Discharging System with High Power Factor, High Efficiency)

  • 김은수;조기연;변영복;구헌회
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.371-375
    • /
    • 1995
  • This paper presents equipment for charging and discharging with high power factor and high efficiency. This equipment is consisted of $3{\phi}$ SPWM AC/DC converter for improving input current waveform and input power factor, and bidirectional DC/DC converter for electric isolation in the DC link Part. Therefore, Input power factor and the total efficiency in the proposed system can be increased more than in the conventional phase-controlled thyristor charging-discharging System.

  • PDF

DC 배전용 3상 AC/DC 컨버터의 병렬 운전시 발생하는 순환전류 제어 알고리즘 (Control Algorithm for Circulating Currents in Parallel Operation of Three-Phase AC/DC Converter for DC Distribution System)

  • 정철호;신수철;정태복;이택기;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.167-168
    • /
    • 2011
  • 본 논문에서는 여러 대의 전력변환장치를 모듈화 하여 병렬 운전할시 필연적으로 발생하게 되는 순환전류를 억제하기 위한 제어 기법을 제안하였다. 이에 따라 병렬 운전 시스템이 갖는 응답 특성 및 정상상태 동작 등의 타당성을 시뮬레이션 모델을 통하여 검토하였다.

  • PDF

AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 라인 인터렉티브 무정전전원장치 시스템 (A Novel Three-Phase Line-Interactive UPS System having AC Line Reactor and Parallel-Series Active Filters)

  • 지준근
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2004년도 춘계학술대회
    • /
    • pp.193-197
    • /
    • 2004
  • The four-leg Voltage Source Converter(VSC) can use the DC link voltage effectively by the 3-D SVPWM method. Hence the DC battery voltage can be reduced by $15\%$ in comparison to that of the conventional line-interactive UPS system. In this paper a novel line interactive Uninterruptible Power Supply(UPS) using the two four-leg VSCs is proposed. One VSC is in parallel with the ac link reactor of the power source side, and the other is in series with the load. The parallel four-leg voltage source inverter controls the three-phase line voltage independently in order to control the line reactor current indirectly. It eliminates the neutral line current and the active ripple power of the source side using the pqr theory so that unity power factor and the sinusoidal source current can be achieved even though both the source and the load voltages have zero sequence components. The series four-leg voltage source inverter compensates the line voltage and allows it to be balanced and harmonic-free. Both of the parallel and series four-leg voltage source inverters always act as independently controllable voltage sources, so that the three-phase output voltage shows a seamless transition to the backup mode. The feasibility of the proposed UPS system has been investigated and verified through computer simulations results.

  • PDF

매트릭스 컨버터 기반의 3상 절연형 커패시터리스 컨버터 (Three-Phase Isolated Capacitorless Converter Based on Matrix Converter)

  • 이형주;채수용;홍순찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 추계학술대회 논문집
    • /
    • pp.233-234
    • /
    • 2013
  • 본 논문에서는 급속충전기에 적용 가능한 매트릭스 컨버터 기반의 3상 절연형 커패시터리스 컨버터를 제안한다. 제안하는 컨버터는 직류 링크단의 전해 커패시터를 제거함으로써 기존의 풀브리지형 컨버터에 비해 부피가 작고 신뢰성이 향상되는 장점이 있다. 또한, 기존의 충전기가 AC-DC 변환기와 DC-DC 변환기를 포함한 2단 구조인데 비해 제안하는 충전기는 매트릭스 컨버터 회로를 이용한 1단 구조로서 제어부 구성이 간단한 장점이 있다. 본 논문에서는 제안한 충전기를 해석하고, 시뮬레이션을 통하여 제안한 충전기의 유효성을 확인한다.

  • PDF

단상 부스터 콘버터의 입력역률 개선을 위한 가변 밴드폭 제어방식에 관한 연구 (A Study on the Variable Hysteresis Current Mode Control Method for Power Factor Improvement of the Single Phase Boost Converter)

  • 김철우;권순재;유동욱;박성준
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제8권3호
    • /
    • pp.36-43
    • /
    • 1994
  • 본 연구는 교류전원측에서 콘버터에 의해 출력전압조정과 동시에 입력전류가 전압과 동상에 가까운 정현파가 되도록 하기 위해 고주파 스위칭에 의한 단상 부스터 콘버터의 제어방식을 분석하고 가변밴드폭 제어방식에 의해 1[kW]부하에 대하여 각 파라메타를 산정하며 실험장치를 구성하여 주파수 스팩트럼 분석기에 의한 분석을 토대로 고역률 동작을 확인하고자 한다.

  • PDF

누설변압기가 부착된 전원 불평형 3상 전압형 PWM 컨버터 운전법 (Operating Method of 3 Phase Voltage type PWM Converter for Unbalanced Voltage with Leakage Transformer)

  • 전지용;김영춘;조유환;이근홍
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.125-127
    • /
    • 2005
  • In this paper, the control algorithm of DC source device for inverter starting is proposed and the control method for compensating unbalance system source on operating time in the voltage type PWM converter with driving and regenerative faculty is suggested. The maintaining way of balancing condition for converter of AC source is used the compensating unbalanced status by current control loop. Because it is possible that the unbalanced System control is used to leakage transformer not equaled reactance by each phase in rectifier system, the proposed H/W and control algorithm of rectifier system is contributed to minimize of device and rising efficiency.

  • PDF

DC배전용 3상 AC/DC 컨버터의 새로운 Droop 제어를 이용한 병렬운전 (Parallel Operation using New Droop Control of Three-Phase AC/DC Converter for DC Distribution Systems)

  • 박윤욱;신수철;이희준;이택기;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 추계학술대회 논문집
    • /
    • pp.245-246
    • /
    • 2013
  • 본 논문에서는 DC배전용 전력변환장치를 모듈화하여 병렬운전을 하기 위한 새로운 Droop 제어를 제안한다. 제안한 방식은 동일용량의 모듈을 병렬로 용이하게 연결할 수 있으며 모듈간 제어진동을 최소화하고 순환전류를 억제한다. 이에 따라 병렬 운전 시스템이 갖는 과도응답 및 정상상태 특성 등을 시뮬레이션과 실험을 토대로 그 타당성을 검증하였다.

  • PDF

3상 전압형 PWM 컨버터의 특성개선에 관한 연구 (A Study On The Characteristic Improvement of 3 Phase Voltage Source PWM Converter)

  • 정연택;김원철;전지용;김현우;이근홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.830-832
    • /
    • 1993
  • In this paper, A voltage source PWM converter which achieves bidirectional power flow between a $3{\phi}$ AC supply and a DC bus voltage is described. And the paper considers both the steady state and transient response of such a device, and develops mathematical models to describe its performance under the digital control system. As a result the AC line current becomes sinusoidal and the input power factor is improved to unity.

  • PDF

H-Bridge VSC with a T-Connected Transformer for a 3-Phase 4- Wire Voltage and Frequency Controller of an Isolated Asynchronous Generator

  • Kasal, Gaurav Kumar;Singh, Bhim
    • Journal of Power Electronics
    • /
    • 제9권1호
    • /
    • pp.43-50
    • /
    • 2009
  • This paper deals with a novel solid state controller (NSSC) for an isolated asynchronous generator (IAG) feeding 3-phase 4-wire loads driven by constant power prime movers, such as uncontrolled pico hydro turbines. AC capacitor banks are used to meet the reactive power requirement of the asynchronous generator. The proposed NSSC is realized using a set of IGBTs (Insulated gate bipolar junction transistors) based current controlled 2-leg voltage source converters (CC- VSC) and a DC chopper at its DC bus, which keeps the generated voltage and frequency constant in spite of changes in consumer loads. The neutral point of the load is created using aT-configuration of the transformers. The IAG system is modeled in MATLAB along with Simulink and PSB (power system block set) toolboxes. The simulated results are presented to demonstrate the capability of the isolated generating system consisting of NSSC and IAG driven by uncontrolled pico hydro turbine and feeding 3-phase 4-wire loads.

전류형 MPPT를 이용한 3 kW 태양광 인버터 시스템 제어기 설계 및 구현 (Design and implementation of 3 kW Photovoltaic Power Conditioning System using a Current based Maximum Power Point Tracking)

  • 차한주;이상회;김재언
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1796-1801
    • /
    • 2008
  • In this paper, a new current based maximum power point tracking (CMPPT) method is proposed for a single phase photovoltaic power conditioning system and the current based MPPT modifies incremental conductance method. The current based MPPT method makes the entire control structure of the power conditioning system simple and uses an inherent current source characteristic of solar cell array. In addition, digital phase locked loop using an all pass filter is introduced to detect phase of grid voltage as well as peak voltage. Controllers about dc/dc boost converter, dc-link voltage, dc/ac inverter is designed for a coordinated operation. Furthermore, PI current control using a pseudo synchronous d-q transformation is employed for grid current control with unity power factor. 3kW prototype photovoltaic power conditioning system is built and its experimental results are given to verify the effectiveness of the proposed control schemes.