• 제목/요약/키워드: 3-phase AC-DC converter

검색결과 181건 처리시간 0.027초

A Novel Three Phase Series-Parallel Resonant Converter Fed DC-Drive System

  • Daigavane, Manoj;Suryawanshi, Hiralal;Khan, Jawed
    • Journal of Power Electronics
    • /
    • 제7권3호
    • /
    • pp.222-232
    • /
    • 2007
  • This paper presents the application of a single phase AC-to-DC converter using a three-phase series parallel (SPRC) resonant converter to variable speed dc-drive. The improved power quality converter gives the input power factor unity over a wide speed range, reduces the total harmonic distortion (THD) of ac input supply current, and makes very low ripples in the armature current and voltage waveform. This soft-switching converter not only possesses the advantages of achieving high switching frequencies with practically zero switching losses but also provides full ranges of voltage conversion and load variation. The proposed drive system is the most appropriate solution to preserve the present separately excited de motors in industry compared with the use of variable frequency ac drive technology. The simulation and experimental results are presented for variable load torque conditions. The variable frequency control scheme is implemented using a DSP- TMS320LF2402. This control reduces the switching losses and current ripples, eliminates the EMI and improves the efficiency of the drive system. Experimental results confirm the consistency of the proposed approach.

직류링크 전해커패시터 없는 AC-DC-AC 컨버터 재어에 관한 연구 (New Control Seheme for AC-DC-AC Converters without DC Link Electrolytic Capacitor)

  • 김준석;설승기
    • 대한전기학회논문지
    • /
    • 제43권3호
    • /
    • pp.397-408
    • /
    • 1994
  • In this paper, a novel concept for a static three-phase to three-phase power converter for an AC drive with a unity power factor and reduced harmonics on the utility line is presented. The power circuit consists of two back-to-back connected six-pulse bridges having only a $\mu$F ceramic capacitor in the DC link. By controlling the active kpower balance between two bridges, the DC link voltage can be maintained within 20V deviation from the nominal value with the small ceramic capacitors regardless of the load variation even in the unbalanced source condition.

  • PDF

Model Predictive Control of Bidirectional AC-DC Converter for Energy Storage System

  • Akter, Md. Parvez;Mekhilef, Saad;Tan, Nadia Mei Lin;Akagi, Hirofumi
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.165-175
    • /
    • 2015
  • Energy storage system has been widely applied in power distribution sectors as well as in renewable energy sources to ensure uninterruptible power supply. This paper presents a model predictive algorithm to control a bidirectional AC-DC converter, which is used in an energy storage system for power transferring between the three-phase AC voltage supply and energy storage devices. This model predictive control (MPC) algorithm utilizes the discrete behavior of the converter and predicts the future variables of the system by defining cost functions for all possible switching states. Subsequently, the switching state that corresponds to the minimum cost function is selected for the next sampling period for firing the switches of the AC-DC converter. The proposed model predictive control scheme of the AC-DC converter allows bidirectional power flow with instantaneous mode change capability and fast dynamic response. The performance of the MPC controlled bidirectional AC-DC converter is simulated with MATLAB/Simulink(R) and further verified with 3.0kW experimental prototypes. Both the simulation and experimental results show that, the AC-DC converter is operated with unity power factor, acceptable THD (3.3% during rectifier mode and 3.5% during inverter mode) level of AC current and very low DC voltage ripple. Moreover, an efficiency comparison is performed between the proposed MPC and conventional VOC-based PWM controller of the bidirectional AC-DC converter which ensures the effectiveness of MPC controller.

Reduced Rating T-Connected Autotransformer Based Thirty-Pulse AC-DC Converter for Vector Controlled Induction Motor Drives

  • Singh Bhim;Bhuvaneswari G.;Garg Vipin
    • Journal of Power Electronics
    • /
    • 제6권3호
    • /
    • pp.214-225
    • /
    • 2006
  • The design and performance analysis of a reduced rating autotransformer based thirty-pulse AC-DC converter is carried out for feeding a vector controlled induction motor drive (VCIMD). The configuration of the proposed autotransformer consists of only two single phase transformers, with their windings connected in a T-shape, resulting in simplicity in design, manufacturing and in a reduction in magnetics rating. The design procedure of the autotransformer along with the newly designed interphase transformer is presented. The proposed configuration has flexibility in varying the transformer output voltage ratios as required. The design of the autotransformer can be modified for retrofit applications, where presently a 6-pulse diode bridge rectifier is used. The proposed thirty-pulse AC-DC converter is capable of suppressing less than $29^{th}$ harmonics in the supply current. The power factor is also improved to near unity in the wide operating range of the drive. A comparison of different power quality indices at AC mains and DC bus is demonstrated in a conventional 6-pulse AC-DC converter and the proposed AC-DC converter feeding a VCIMD. A laboratory prototype of the proposed autotransformer based 30-pulse AC-DC converter was developed with test results validating the proposed design and system.

적응 궤환 선형화를 이용한 3상 AC/DC 전압원 컨버터 제어 (Adoptive Feedback Linearization Control of Three-Phase AC/DC Voltage-Source Converter)

  • 박영환;박장현;강문호
    • 조명전기설비학회논문지
    • /
    • 제20권3호
    • /
    • pp.62-68
    • /
    • 2006
  • 본 논문에서는 3상 AC/DC 컨버터의 적응 입출력 선형화와 영점 동특성식 제어 기법을 제안한다. 컨버터 출력 dc전압이 단위 역률을 유지하도록 회전 d-q 프레임의 q축 전류가 영의 값으로 유지되고 출력전압은 주어진 기준전압 $V_r$을 추종하도록 제어된다. 제안된 제어기법은 적응 프로세스를 이용해 파라미터 불확실성과 부하 전류 변화에 대해 견실하다. 제안된 제어 기법의 효용성과 타당성을 보이기 위해 시뮬레이션 연구가 수행되었다.

Analysis, Design, and Implementation of a Single-Phase Power-Factor Corrected AC-DC Zeta Converter with High Frequency Isolation

  • Singh, Bhim;Agrawal, Mahima;Dwivedi, Sanjeet
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.243-253
    • /
    • 2008
  • This paper deals with the analysis, design, and implementation of a single phase AC-DC Zeta converter with high frequency transformer isolation and power factor correction(PFC) in two modes of operation, discontinuous current mode of operation(DCM), and continuous current mode of operation(CCM). A Digital Signal Processor(DSP) based implementation is carried out for validation of the Zeta converter developed design in discontinuous mode of operation. A comparison of both modes of operation is presented for a 1kW power rating from the point of view of steady state and dynamic behavior, power quality, simplicity, control technique, device rating, and converter size. The experimental results of a developed prototype of Zeta converter are presented for validation of the developed design. It is observed that CCM is most suitable for higher power applications where it requires some complex control and sensing of the additional variables.

3상 AC/DC/AC PWM 컨버터의 직류링크 리플전류의 주파수 영역 해석 (Spectral Analysis of DC Link Ripple Currents in Three-Phase AC/DC/AC PWM Converters)

  • 이동춘;박영욱;석줄기
    • 전력전자학회논문지
    • /
    • 제7권3호
    • /
    • pp.244-252
    • /
    • 2002
  • 본 논문에서는 가변속 교류 전동기 구동에 많이 사용되는 3상 ac/dc/ac PWM 컨버터 시스템에서의 직류링크 리플전류를 주파수 영역에서 해석하고자 한다. 고조파 전류는 컨버터의 스위칭함수와 지수함수 형태의 퓨리에 급수 전개를 이용하여 분석된다. 전원측 컨버터와 부하측 인버터의 스위칭 주기간의 변위각과 비동기 PW이 리플전류에 미치는 영향도 고찰된다. 해석 결과가 PSIM을 이용한 시뮬레이션으로부터 나온 고조파 스펙트럼과 잘 일치함을 확인한다 제시된 해석기법은 PWM의 원리에 대한 이해를 돕고, 해석 결과는 직류링크 커패시터의 고주파 등가 모델링에 이용된다.

연료전지를 적용한 무정전전원장치용 3상 AC/DC 컨버터의 DC-Link 전압 리플 저감 (Reduction of DC-Link Voltage Ripple of Three-phase AC/DC Converter for Uninterruptible Power Supply by Applying Fuel Cell)

  • 박진호;김경민;이정효;원충연
    • 조명전기설비학회논문지
    • /
    • 제24권6호
    • /
    • pp.43-51
    • /
    • 2010
  • 기존의 무정전전원장치(UPS: Uninterruptible Power Supply)는 배터리를 보조전원으로 사용함으로써 큰 부피와 수명에 제한을 받게 될 뿐만 아니라, 급격한 부하변동에 따른 배터리 전압의 변동으로 UPS 시스템 출력에 문제점을 야기한다. 본 논문에서는 보조전원으로 쓰이는 기존의 배터리 대신에 친환경 대체 에너지원인 연료전지를 무정전전원장치용 3상 AC/DC 컨버터에 적용하여 급격한 부하 변동 시 에너지를 보상하고 안정된 출력을 갖도록 하였다.

TMS320C40을 이용한 3상 PWM AC/DC 컨버터 제어 (DSP(TMS320C40) Control of Three-phase PWM AC/DC Converter)

  • 변영복;김은수;구헌회;조기연;박성준;김철우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.518-520
    • /
    • 1996
  • High frequency switching converters are becoming more popular because of several benefits which are essential in power conversion system. This paper introduces a high speed digital controller using TMS320C40 DSP chip which can be used for high frequency switching converters and demonstrates its performance by operating three-phase PWM AC/DC converter with unity power factor at 20kHz sampling frequency. TMS320C40 DSP chip operates with 40-ns instruction cycle times and is capable of 275 MOPS. The running time of real time control loop at the three-phase PWM AC/DC converter is $44.6{\mu}sec$.

  • PDF

다상화 dc/dc converter의 모델링 및 해석 (A Modeling and Analysis of Poly-phase dc/dc Converter)

  • 김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.512-515
    • /
    • 1991
  • The advantages of poly-phase converter are to be able to reduce the ripple current and to lessen the weight of power inductors. This paper is derived the equivalent circuit, dc of and ac modeling circuit of a 3-phase multiple buck converter by using state space representation and averaging techniche. Futhermore, it is represented the equivalent circuits according to the duty cycle.

  • PDF