• Title/Summary/Keyword: 3-level modulation

Search Result 365, Processing Time 0.019 seconds

SVPWM Overmodulation Scheme of Three-Level Inverters for Vector Controlled Induction Motor Drives

  • Kwon, Kyoung-Min;Lee, Jae-Moon;Lee, Jin-Mok;Choi, Jae-Ho
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.481-490
    • /
    • 2009
  • This paper describes a SVPWM overmodulation scheme of NPC type three-level inverter for traction drives which extends the modulation index from MI=0.907 to unity. SVPWM strategy is organized by two operation modes of under-modulation and over-modulation. The switching states under the under-modulation modes are determined by dividing them with two linear regions and one hybrid region the same as the conventional three-level inverter. On the other hand, under the over-modulation mode, they are generated by doing it with two over-modulation regions the same as the conventional over-modulation strategy of a two level inverter. Following the description of over-modulation scheme of a three-level inverter, the system description of a vector controlled induction motor for traction drives has been discussed. Finally, the validity of the proposed modulation algorithm has been verified through simulation and experimental results.

Performance of 4-level Modulation Code for Holographic Data Storage (홀로그래픽 데이터 저장장치를 위한 4-레벨 변조 부호의 성능 비교)

  • Park, Keunhwan;Lee, Jaejin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.9
    • /
    • pp.1672-1677
    • /
    • 2015
  • The multi-level holographic storage system can store more than one bit per pixel. In this paper, we introduce a 6-pixel 4-level modulation code and compare with 4-level 6/9 modulation code and 2/3 modulation code. The proposed 6-pixel modulation code has the minimum Euclidean distance 3. The 6-pixel modulation code is approximately 1dB better than the other modulation codes.

A Study on the 3 phase 5 level PWM inverter reducing harmonics (고조파 저감형 3상 5레벨 PWM 인버터에 관한 연구)

  • 송언빈
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.80-84
    • /
    • 1995
  • ABSTRACT - This paper presents a software based 3 phase 5 level pulse-width modulation(PWM) inverter to reduce total harmonic distortion. The proposed modulation technique can reduce total harmonic distortion and significantly improve the performance of the inverter. In the modulation mode where the frequency ratio is 36 and modulation index is 1.2∼2.0, harmonic components have been mostly eliminated and the magnitude of fundamental component have been maximized by the 3 phase 5 level PWM inverter.

  • PDF

4-Level 4/6 Modulation Code with Trellis Encoding on Holographic Data Storage (홀로그래픽 데이터 저장장치에서 트렐리스 인코딩을 이용한 4-레벨 4/6 변조부호)

  • Jeong, Seongkwon;Lee, Jaejin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.6
    • /
    • pp.11-16
    • /
    • 2017
  • Multi-level holographic data storage requires modulation codes for avoiding two dimensional inter-symbol interference (2D-ISI). Modulation codes can remove the fatal ISI pattern of neighboring the largest and the smallest symbols. In this paper, we propose a 4-level 4/6 modulation code and its trellis encoding for error correction. The proposed 4/6 modulation code prevents that the symbol 0 and 3 are not adjacent in any direction. Also, we compare the proposed modulation code with the same code rate modulation codes for four-level holographic data storage.

Equivalent RMS Sine-wave Modulation of the Step-pulse type Multi-level Inverter (스텝펄스형 멀티레벨 인버터를 위한 RMS 등가형의 새로운 사인파 변조법)

  • Jin, Sun-Ho;Kwak, Jun-Ho;Jo, Kwan-Jun;Oh, Jin-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.239-246
    • /
    • 2006
  • This paper suggests a new modulation strategy for step pulse type multi-level inverter. The proposed strategy is simple to determine the switching angles without regard to increase of levels. Designed to extract the equivalent RMS value compared to ideal sine wave from inverter, it can be applied effectively to high level step pulse inverter. Also this paper proposed modulation strategy for modified H-bridge 13 level inverter which has different cell source voltages with simulation and experiment. The modulation characteristics from simulation and experiment, agreed very well with tracing sine wave about modified structure of cascaded H-bridge multi-level inverter.

Normalization Factor for Three-Level Hierarchical 64QAM Scheme (3-level 계층 64QAM 기법의 정규화 인수)

  • You, Dongho;Kim, Dong Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.1
    • /
    • pp.77-79
    • /
    • 2016
  • In this paper, we consider hierarchical modulation (HM), which has been widely exploited in digital broadcasting systems. In HM, each independent data stream is mapped to the modulation symbol with different transmission power and normalization factors of conventional M-QAM cannot be used. In this paper, we derive the method and formula for exact normalization factor of three-level hierarchical 64QAM.

Analysis and simulation of Cascaded H-bridge 7 level inverter for eliminating typical harmonic waveforms (특정 고조파 제거를 위한 Cascaded H-bridge 7레벨 인버터의 특성해석 및 시뮬레이션)

  • Jin, Sun-Ho;Oh, Jin-Suk;Jo, Kwan-Jun;Kwak, Jun-Ho;Lim, Myoung-Kyu;Kim, Jang-Mok
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.1022-1028
    • /
    • 2005
  • This paper is presented the analysis results and simulation results of cascaded H-bridge 7 level inverter with various modulation index. Stepped waveform having number of switching was used to eliminate harmonic components. Switching angles according to modulation index are calculated numerically. Therefore, 3 times of switching with 7 level topology and QWS(Quarter Wave Symmetry) could eliminate 5th and 7th harmonics. The harmonic characteristics are compared to those of space vector modulation method which known as common modulation method in industrial field. Stepped waveform method showed higher ability to reduce, especially lower order of harmonics.

  • PDF

A Prioritized Transmission Scheme for Three-Dimensional Integral Imaging (3차원 집적 영상을 위한 우선순위 전송 기법)

  • Cho, Myungjin;Choi, Hyun-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.5
    • /
    • pp.447-455
    • /
    • 2014
  • In this paper, we consider a representative integral imaging method in glasses-free 3D image processing and propose a prioritized transmission scheme for guaranteeing a received video quality in error-prone environments. According to the correlation of pixels consisting of each voxel of integral image, we set the priority differently and apply the modulation level according to this priority value. That is to say, the corresponding pixels with small variance are set to a high priority and transmitted by using a low level modulation that is robust under transmission errors, but the corresponding pixels with greater variance are set to a lower priority and transmitted by using a high level modulation that has a high bit error rate but fast transmission rate. Result shows that the proposed scheme that applies the error-robust modulation level to the important image bit stream with the high priority improves the peak to sidelobe ratio (PSR) of the received 3D image, compared with a typical method that use the same modulation level without distinction of priorities.

Optimized Space Vector Pulse-width Modulation Technique for a Five-level Cascaded H-Bridge Inverter

  • Matsa, Amarendra;Ahmed, Irfan;Chaudhari, Madhuri A.
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.937-945
    • /
    • 2014
  • This paper presents an optimized space vector pulse-width modulation (OSVPWM) technique for a five-level cascaded H-bridge (CHB) inverter. The space vector diagram of the five-level CHB inverter is optimized by resolving it into inner and outer two-level space vector hexagons. Unlike conventional space vector topology, the proposed technique significantly reduces the involved computational time and efforts without compromising the performance of the five-level CHB inverter. A further optimized (FOSVPWM) technique is also presented in this paper, which significantly reduces the complexity and computational efforts. The developed techniques are verified through MATLAB/SIMULINK. Results are compared with sinusoidal pulse-width modulation (SPWM) to prove the validity of the proposed technique. The proposed simulation system is realized by using an XC3S400 field-programmable gate array from Xilinx, Inc. The experiment results are then presented for verification.

2/3 Modulation Code and Its Vterbi Decoder for 4-level Holographic Data Storage (4-레벨 홀로그래픽 저장장치를 위한 2/3 변조부호와 비터비 검출기)

  • Kim, Gukhui;Lee, Jaejin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.10
    • /
    • pp.827-832
    • /
    • 2013
  • Holographic data storage system is affected by two dimensional intersymbol interference and inter-page interference. Especially, for multi-level holographic data storage system, since one pixel contains more than 1 bit, the system is more vulnerable to the error. In this paper, we propose a 2/3 modulation code for 4-level holographic data storage system. The proposed modulation code with error correcting capability could be compensated these interferences. Also, in this paper, we proposed a Viterbi decoder for 2/3 modulation code. The proposed Viterbi decoder eliminates unnecessary calculation. As a result, proposed 2/3 modulation code and Viterbi decoder has shown better performance than conventional one.