• Title/Summary/Keyword: 3-hop test

Search Result 26, Processing Time 0.02 seconds

ACL reconstruction with autologous hamstring tendon - Short term clinical result using new femoral suspensory fixation device 'Cross Pin' and graft tensioner for maintaining a constant tension- (자가 슬괵건을 이용한 전방 십자 인대 재건술 - 새로운 대퇴부 현수고정법인 Cross Pin과 일정한 긴장력 유지를 위한 Graft Tensioner 사용의 단기 추시 결과 -)

  • Seo, Seung-Suk;Kim, Chang-Wan;Kim, Jin-Seok;Choi, Sang-Yeong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.1
    • /
    • pp.27-34
    • /
    • 2011
  • Purpose: To evaluate the short term clinical result of ACL reconstruction with autologous hamstring tendon using Cross pin and Graft Tensioner and to seek way to resolve the experienced technical problems. Materials and Methods: From January 2008 to March 2009, 35 patients who had been treated arthroscopic ACL reconstruction were enrolled. The femoral side of ACL graft was fixed with Cross pin. The tibial side of graft was fixed with Intrafix and post-tie. The graft was tensioned with Graft Tensioner at 80N. We analyzed the clinical, radiographic results and complications. Results: IKDC subjective score and Lysholm score improved to 89.1 and 91.4 points. Also, Pivot shift test and One-leg hop test showed good results postoperatively. Side to side difference using KT-1000 arthrometer and Telos stress radiography improved compared with normal limb to $2.8{\pm}1.6$ mm and $2.6{\pm}1.3$ mm, respectively. The femoral tunnel enlarged to $2.3{\pm}1.1$ mm. Soft tissue irritation and femoral tunnel-graft harness length mismatch, femoral tunnel-cross pin tunnel mismatch were happened as peri-operative complications. Conclusion: Using of Cross pin and Graft Tensioner for ACL reconstruction with hamstring tendon is one of the good method for obtaining stability in short-term clinical result. But to reduce femoral tunnel-cross pin mismatch, it needs to shorten femoral bone tunnel and to create cross pin tunnel as vertical as possible. And to reduce femoral tunnel-graft harness mismatch, it needs to advance position rod further 3 mm when to create femoral tunnel.

  • PDF

The effect of ankle Kinesio taping on range of motion and agility during exercise in university students

  • Eom, Se Young;Lee, Won Jun;Lee, Jae Il;Lee, Eun Hee;Lee, Hye Young;Chung, Eun Jung
    • Physical Therapy Rehabilitation Science
    • /
    • v.3 no.1
    • /
    • pp.63-68
    • /
    • 2014
  • Objective: The purpose of this study was to examine the effects of ankle Kinesio taping on range of motion and agility during exercise in university students. Design: Cross-sectional study. Methods: Thirty subjects were randomly allocated to two groups: taping group (n=15) and non-taping group (n=15). All groups underwent the same exercise program including stretching for 30 minutes. The exercise program proceeded in the following order: five minutes of stretching, a 20-minutes exercise program, and additional five minutes of stretching. Of the eight exercise methods suggested by Purcell et al, seven were chosen (lateral shuffle, forward and backward running, agility ladder, figure-of-8, forward jogging while jumping over cones, wall jumps and zigzags); $90^{\circ}$ cuts with lateral shuffle were omitted. The range of motion of ankle dorsiflexion and plantarflexion was measured using the goniometer. Agility was measured using the side hop test. Results: For ankle range of motion, the taping group showed significant differences in dorsiflexion and plantarflexion on both sides (p<0.05). The non-taping group showed significant differences only in left plantarflexion (p<0.05). There was a significant difference in dorsiflexion on both sides between the taping group and the non-taping group (p<0.05). All groups showed significant differences in agility on the left and right ankle (p<0.05). There was a significant difference in left ankles between the taping group and the non-taping group (p<0.05). Conclusions: Kinesio taping increased range of motion and agility during exercise in university students. Additional research on Kinesio taping for improving range of motion and agility is needed.

Designing of Network based Tiny Ubiquitous Networked Systems (네트워크 기반의 소형 유비쿼터스 시스템의 개발)

  • Hwang, Kwang-Il;Eom, Doo-Seop
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.13 no.3
    • /
    • pp.141-152
    • /
    • 2007
  • In this paper, we present a network-oriented lightweight real-time system, which is composed of an event-driven operating system called the Embedded Lightweight Operating System (ELOS) and a generic multi hop ad hoc routing protocol suite. In the ELOS, a conditional preemptive FCFS scheduling method with a guaranteed time slot is designed for efficient real-time processing. For more elaborate configurations, we reinforce fault tolerance by supplementing semi-auto configuration using wireless agent nodes. The developed hardware platform is also introduced, which is a scalable prototype constructed using off-the-shelf components. In addition, in order to evaluate the performance of the proposed system, we developed a ubiquitous network test-bed on which several experiments with respect to various environments are conducted. The results show that the ELOS is considerably favorable for tiny ubiquitous networked systems with real-time constraints.

Development of Multipoint Simultaneous Full-duplex Team Communication Module for SCBA (SCBA 면체용 다자간 동시 양방향 팀 통신모듈 개발)

  • Kim, Si-Kuk;Choi, Su-Gil;Lim, Woo-Sub;Han, Yong-Taek
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.165-172
    • /
    • 2019
  • This study presents the design and manufacture of a self-contained breathing apparatus SCBA wireless communication module with a multipoint simultaneous full-duplex communication system to enable communication between team members wearing the SCBA system. It is necessary for fire-fighters to wear the SCBA system during extinguishing and rescue work at the fire site. Evaluation of the team communication module confirmed the feasibility of communication over more than 500 m in the test condition based on the line of sight. By implementing the Ad-hoc function, it was confirmed that the communication distance could be extended to 128 m by automatic routing up to 3 hoc. The vertical distance inside the building for successful communication was up to the 5th floor in the open staircase and up to the 3rd floor in the partitioned staircase. Furthermore, the performance testing of the communication module assuming a fire situation, confirmed that five team members correctly recognized the standard abbreviation of fire and wireless communication without a separate PTT key operation. In addition, the flame resistance was verified by exposing the module to a flame at 950 ± 50 ℃ for 5 s and then immediately extinguishing the flame.

THE CHANGE OF CANAL CONFIGURATION AFTER INSTRUMENTATION BY SEVERAL NICKEL-TITANIUM FILES IN THE SIMULATED CANAL WITH ABRUPT CURVATURE (수종의 엔진구동형 니켈-타이타늄 파일에 의한 급한 만곡의 근관 성형시 근관형태 변화에 대한 비교연구)

  • Lim, Jung-Jang;Kim, Dong-Jun;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.303-311
    • /
    • 2005
  • The purpose of this study was to evaluate which type of Ni-Ti files are able to maintain canal configuration better in the simulated canal with abrupt curvature near it's apex. Ninety six simulated root canals were made in epoxy resin and $\sharp$15 finger spreader was used as root canal templates. The simulated root canals were made with radius of curvature of 1.5mm, 3.0mm, 4.0mm, 6.0mm respectively and the angle of curvature of all simulated canals were adjusted to 90 degree. The simulated canals were instrumented by ProFile, ProTaper, Hero 642, and $K^3$ at a 300 rpm using crown-down pressureless technique. Pre-instrumented and post-instrumented images were taken by digital camera and were superimposed with Adobe Photos hop 6.0 program. Images were compared by image analysis program. The changes of canal width at the inner and outer side of the canal curvature. canal transportation were measured at 9 measuring point with 1 mm interval. Statistical analysis among the types of Ni-Ti files was performed using Kruskal-Wallis test and Mann-Whitney U-test. The result was that ProFile maintain original canal configuration better than other engine driven Ni-Ti files in the canals above 3.0mm radius of curvature, and in the 1.5mm radius of curvature, most of Ni-Ti flies were deformed or separated during instrumentation.

The Effects of Active Movement Myofascial Decompression Therapy and Static Myofascial Decompression Therapy on Range of Motion, Muscle Strength, Functional Movement in Young Adults. (젊은 성인에서 능동 움직임을 결합한 근막감압치료 적용과 정적 적용이 관절가동범위, 근력, 기능적 움직임에 미치는 영향)

  • Lee, Jee-Hyun;Kim, Tae-Hyeon;Kang, Si-Yun;Kum, Do-Gun;Lee, Sung-Yeon;Do, Kwang-Sun;Kim, Chang-Sook;Bae, Ju-Han;Park, Jun-Hyuck;Kim, Jae-Eun
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.3
    • /
    • pp.165-173
    • /
    • 2021
  • Purpose : Myofascial decompression is frequently mentioned as a method applied to cupping. The purpose of this study is to evaluate and compare active range of motion (AROM), muscle strength, and functional movement by applying myofascial decompression to the hamstrings. Methods : This study evaluated AROM, muscle strength, and functional movement by applying active movement myofascial decompression and static myofascial decompression to the dominant leg, respectively, in a crossover design conducted with normal adults (n=21) in their average 20s enrolled at G University in G city, Gyeongsangbuk-do. Active movement myofascial decompression was implemented for five minutes at a rate of 100 bpm to make the beats in flexion and extension respectively. Static myofascial decompression was only performed for five minutes while at rest. All of these interventions were performed at a cupping depth of two mm. After a one-week washout period, static was applied again to compare the same dependent variables. Results : Regarding AROM and muscle strength, both groups showed significant differences in the before and after results (p<.05). However, in the Functional Reach Aspect and Single Leg Hop test, the active movement myofascial decompression group showed better results. There was no statistical difference between the Active movement myofascial decompression group and Static myofascial decompression group in any dependent variable (p<.05). Conclusion : As a result of this experiment, both active movement myofascial decompression and static myofascial decompression had a positive effect on dependent variable. Therefore this study is meaningful in that it is easier and simpler to see the effect on flexibility, muscle strength, and functional movement just by implementing movement myofascial decompression.