• 제목/요약/키워드: 3-dimensional scanning

Search Result 516, Processing Time 0.029 seconds

Stability Evaluation of Multi-storied Stone Pagoda in the Daewonsa Temple using Three-dimensional Image Analysis (3차원 영상분석을 이용한 대원사다층석탑의 안정성 평가)

  • Jun, Byung-Kyu;Lee, Chan-Hee;Suh, Man-Cheol
    • Journal of Conservation Science
    • /
    • v.22
    • /
    • pp.31-42
    • /
    • 2008
  • A stone cultural heritage often lacks design drawing and detailed geometric informations, thus it becomes more difficult to conservation and restoration. Even though there is active database of detail shape information and numerical measurement for stone monuments, most of the data is in hard-to-utilize two-dimensional images. The new technology developed to overcome this problem is three-dimensional image scanning system. The multi-storied stone pagoda of the Daewonsa temple was analysed with 3D scanning image data then survey map with orientation displacement was evaluated. The difference of each side became apparent with the members of the stone properties was measured, also horizontal and vertical displacement occurred. Horizontal displacement occurred in increasing severity from left to right and from body section to upper part. The 8th roof stones are leaning toward northwest direction due to lateral displacement. The evaluation and measurement of displacement could cause a little errors due to the characteristics uneven surface of stone monuments, computer program and mistakes from the researcher. In future, more precise measurement and stability studies should be done to suggest that accurate data for conservation and understanding of damage condition can be provided.

  • PDF

3D Extraction Method Using a Low Cost Line Laser (라인레이저를 이용한 3D 모델 추출 방법)

  • Yun, Chun Ho;Kim, Tae Gi;Cho, Yong Wook;Nam, Gi Won;Yim, Choong Hyuk
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.1
    • /
    • pp.108-113
    • /
    • 2017
  • In this paper, we proposed a three-dimensional(3D) scanning system based on laser vision technique for 3D model reconstruction. The proposed scanning system consists of line laser, camera, and turntable. We implemented the 3D scanning system using low quality elements. Although these are low quality elements, we reduced the 3D data reconstruction errors greatly using two methods. First, we developed a maximum brightness detection algorithm. This algorithm extracts the maximum brightness of the line laser to obtain the shape of the object. Second, we designed a new laser control device. This device helps to adjust the relative position of the turntable and line laser. These two methods greatly reduce the measuring noise. As a result, point cloud data can be obtained without complicated calculations.

A Study on the surface and analysis of phase map using optical interferometer (광 간섭계를 이용한 표면 및 위상지도 분석에 관한 연구)

  • Park, June-Do;Shin, Soo-Yong;HwangBo, Seung;Kang, Yong-Chel
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.436-437
    • /
    • 2005
  • 3-dimension object's feature measurement is used several industrial field to produce for examination of demanded high quality products by using optical measurement method. 3-dimension object's feature measurement is separated surface scanning and surface non-scanning. In this research, we illuminated interfero-pattern to object, it was constructed with Michelson interferometer by using laser is one of surface non-scanning method. And we extracted phase-map, it is one of featural measurement analysis of 3-dimensional object by using a phase shifting theory.

  • PDF

Three-dimensional Geometrical Scanning System Using Two Line Lasers (2-라인 레이저를 사용한 3차원 형상 복원기술 개발)

  • Heo, Sang-Hu;Lee, Chung Ghiu
    • Korean Journal of Optics and Photonics
    • /
    • v.27 no.5
    • /
    • pp.165-173
    • /
    • 2016
  • In this paper, we propose a three-dimensional (3D) scanning system based on two line lasers. This system uses two line lasers with different wavelengths as light sources. 532-nm and 630-nm line lasers can compensate for missing scan data generated by geometrical occlusion. It also can classify two laser planes by using the red and green channels. For automatic registration of scanning data, we control a stepping motor and divide the motor's rotational degree of freedom into micro-steps. To this end, we design a control printed circuit board for the laser and stepping motor, and use an image processing board. To compute a 3D point cloud, we obtain 200 and 400 images with laser lines and segment lines on the images at different degrees of rotation. The segmented lines are thinned for one-to-one matching of an image pixel with a 3D point.

Development of Digital 3D Real Object Duplication System and Process Technology (디지털 3차원 실물복제기 시스템 및 공정기술 개발)

  • Lee Won-Hee;Ahn Young-Jin;Jang Min-Ho;Choi Kyung-Hyun;Kim Dong-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.4 s.181
    • /
    • pp.183-190
    • /
    • 2006
  • Digital 3D Real Object Duplication System (RODS) consists of 3D Scanner and Solid Freeform Fabrication System (SFFS). It is a device to make three-dimensional objects directly from the drawing or the scanning data. In this research, we developed an office type SFFS based on Three Dimensional Printing Process and an industrial SFFS using Dual Laser. An office type SFFS applied sliding mode control with sliding perturbation observer (SMCSPO) algorithm for control of this system. And we measured process variables about droplet diameter measurement and powder bed formation etc. through experiments. In case of industrial type SFFS, in order to develop more elaborate and speedy system for large objects than existing SLS process, this study applies a new Selective Dual-Laser Sintering (SDLS) process and 3-axis Dynamic Focusing Scanner for scanning large area instead of the existing f lens. In this process, the temperature has a great influence on sintering of the polymer. Also the laser parameters are considered like that laser beam power, scan speed, and scan spacing. Now, this study is in progress to evaluate the effect of experimental parameters on the sintering process.

Significance of Three-Dimensional Digital Documentation and Establishment of Monitoring Basic Data for the Sacred Bell of Great King Seongdeok (성덕대왕신종의 3차원 디지털 기록화 의미와 모니터링 기초자료 구축)

  • Jo, Younghoon;Song, Hyeongrok;Lee, Sungeun
    • Conservation Science in Museum
    • /
    • v.24
    • /
    • pp.55-74
    • /
    • 2020
  • The Sacred Bell of Great King Seongdeok is required digital precision recording of conservation conditions because of corrosion and partial abrasion of its patterns and inscriptions. Therefore, this study performed digital documentation of the bell using four types of scanning and unmanned aerial vehicle (UAV) photogrammetry technologies, and performed the various shape analyses through image processing. The modeling results of terrestrial laser scanning and UAV photogrammetry were merged and utilized as basic material for monitoring earthquake-induced structural deformation because these techniques can construct mutual spatial relationships between the bell and its tower. Additionally, precision scanning at a resolution four to nine times higher than that of the previous study provided highly valuable information, making it possible to visualize the patterns and inscriptions of the bell. Moreover, they are well-suited as basic data for identifying surface conservation conditions. To actively apply three-dimensional scanning results to the conservation of the original bell, the time and position of any changes in shape need to be established by further scans in the short-term. If no change in shape is detected by short-term monitoring, the monitoring should continue in medium- and long-term intervals.

Trueness and precision of scanning abutment impressions and stone models according to dental CAD/CAM evaluation standards

  • Jeon, Jin-Hun;Hwang, Seong-Sig;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.335-339
    • /
    • 2018
  • PURPOSE. The purpose of the present study was to compare scanning trueness and precision between an abutment impression and a stone model according to dental computer-aided design/computer-aided manufacturing (CAD/CAM) evaluation standards. MATERIALS AND METHODS. To evaluate trueness, the abutment impression and stone model were scanned to obtain the first 3-dimensional (3-D) stereolithography (STL) file. Next, the abutment impression or stone model was removed from the scanner and re-fixed on the table; scanning was then repeated so that 11 files were obtained for each scan type. To evaluate precision, the abutment impression or stone model was scanned to obtain the first 3-D STL file. Without moving it, scanning was performed 10 more times, so that 11 files were obtained for each scan type. By superimposing the first scanned STL file onto the other STL files one by one, 10 color-difference maps and reports were obtained; i.e., 10 experimental scans per type. The independent t-test was used to compare root mean square (RMS) data between the groups (${\alpha}=.05$). RESULTS. The $RMS{\pm}SD$ values of scanning trueness of the abutment impression and stone model were $22.4{\pm}4.4$ and $17.4{\pm}3.5{\mu}m$, respectively (P<.012). The $RMS{\pm}SD$ values of scanning precision of the abutment impression and stone model were $16.4{\pm}2.9$ and $14.6{\pm}1.6{\mu}m$, respectively (P=.108). CONCLUSION. There was a significant difference in scanning trueness between the abutment impression and stone model, as evaluated according to dental CAD/CAM standards. However, all scans showed high trueness and precision.

Initial Experience of Patient-Specific QA for Wobbling and Line-Scanning Proton Therapy at Samsung Medical Center

  • Jo, Kwanghyun;Ahn, Sung Hwan;Chung, Kwangzoo;Cho, Sungkoo;Shin, Eun Hyuk;Park, Seyjoon;Hong, Chae-Seon;Kim, Dae-Hyun;Lee, Boram;Lee, Woojin;Choi, Doo Ho;Lim, Do Hoon;Pyo, Hong Ryull;Han, Youngyih
    • Progress in Medical Physics
    • /
    • v.30 no.1
    • /
    • pp.14-21
    • /
    • 2019
  • Purpose: To report the initial experience of patient-specific quality assurance (pQA) for the wobbling and line-scanning proton therapy at Samsung Medical Center. Materials and Methods: The pQA results of 89 wobbling treatments with 227 fields and 44 line-scanning treatments with 118 fields were analyzed from December 2015 to June 2016. For the wobbling method, proton range and spread-out Bragg peak (SOBP) width were verified. For the line-scanning method, output and two-dimensional dose distribution at multiple depths were verified by gamma analysis with 3%/3 mm criterion. Results: The average range difference was -0.44 mm with a standard deviation (SD) of 1.64 mm and 0.1 mm with an SD of 0.53 mm for the small and middle wobbling radii, respectively. For the line-scanning method, the output difference was within ${\pm}3%$. The gamma passing rates were over 95% with 3%/3 mm criterion for all depths. Conclusions: For the wobbling method, proton range and SOBP width were within the tolerance levels. For the line-scanning method, the output and two-dimensional dose distribution showed excellent agreement with the treatment plans.

Laser Forming of Sheet Metal by Geometrical Information (기하학적 정보를 이용한 이중곡률 형상의 레이저 성형)

  • Kim, Ji-Tae;Na, Seok-Ju
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.91-93
    • /
    • 2005
  • Forming sheet metal by laser-induced thermal stresses (laser forming) has been extensively studied, and the research has focused on two-dimensional geometries using a multi-pass straight line scan. Recently there came out some useful studies or three-dimensional laser forming which is applied to doubly curved shapes. The task of 3D laser forming sheet metal is to determine a set of process parameters such as laser scanning paths, laser power and scanning speed that will make a given shape. New method for laser forming of a doubly curved surface by using geometrical information was proposed and verified by experiments. This method shows good performance in the sense of calculation time and accuracy compared to the inherent strain method.

  • PDF