• 제목/요약/키워드: 3-dimensional computerized tomography

검색결과 37건 처리시간 0.032초

하치조신경 마취시 하악공으로의 접근을 위한 전산화단층촬영을 통한 방사선적 연구 (THE STUDY BY USING THE COMPUTERIZED TOMOGRAPHY IMAGING IN ORDER TO ACCESS TO MANDIBULAR FORAMEN WHILE INFERIOR ALVEOLAR NERVE ANESTHESIA)

  • 김지광;구홍;안진석;국민석;박홍주;오희균;조진형
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제32권6호
    • /
    • pp.566-574
    • /
    • 2006
  • Purpose : This study was performed to provide an anatomical information of the mandibular ramus for the successful inferior alveolar nerve block. Three dimensional images were reconstructed from the computerized tomography (CT) and the anatomical evaluation of the mandibular ramus was done. Materials and methods : Sixty-four patients who had been taken the facial CT scans from 2000, Jan to 2003, June was selected. The patients who had the anterior or posterior teeth misssing, edentulous ridge, and jaw fracture were excepted. In the occulusal plane, the lingual surface angle (LSA) between the mid-sagittal plane and the mandibular molar lingual surface from the 2nd premolar to the 2nd molar, the inner ramal surface angle (IRSA), the maximum inner ramal surface angle (MxIRSA), and the outer ramal surface angle (ORSA) to the-mid sagittal plane were measured. The inner ramal surface angle in the ligular tip level (IRSA-L) and the outer ramal surface angle in the ligular tip level (ORSA-L), the ramal length (RL), and the anterior ramal length (ARL) were also measured in the lingular tip level. Results : In the lingular tip level, the mean IRSA-L and ORSA-L were $28.6{\pm}6.3^{\circ}$ and $17.9{\pm}4.9^{\circ}$ respectively. The larger was the IRSA, the larger was the ORSA. In the lingular tip level, the mean ramal length was 35.8${\pm}$3.4 mm. The larger was the IRSA-L, the shorter was the ramal length. On the lingular tip level, the mean anterior ramal length from anterior ramus to lingular tip was 19.6${\pm}$3.3 mm. when the ramal length was longer, the anterior ramal length was also longer. On the lingular tip level, there was positive correlation vetween the IRSA and the ORSA, negative correlation between the IRSA and the ramal length, and positive correlation between the ramal length and the lingular tip level to the anterior ramus. There was no statistical meaning of data between sex and age. Conclusion : In the clinical view of the results so far achieved, if the direction of needle is closer to posterior it is able to contact bone on lingular tip when the internal surface of ramus is wided outer.

Three-dimensional functional unit analysis of hemifacial microsomia mandible-a preliminary report

  • Choi, Ji Wook;Kim, Byung Hoon;Kim, Hyung Soo;Yu, Tae Hoon;Kim, Bong Chul;Lee, Sang-Hwy
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제37권
    • /
    • pp.28.1-28.7
    • /
    • 2015
  • Background: The aim of this study was to present three-dimensional (3D) structural characteristics of the mandible in the hemifacial microsomia. The mandible has six distinct functional units, and its architecture is the sum of balanced growth of each functional unit and surrounding matrix. Methods: In order to characterize the mandibular 3D architecture of hemifacial microsomia, we analyzed the mandibular functional units of four hemifacial microsomia patients using the 3D reconstructed computed tomography (CT) images. And we compared the functional unit size between affected and non-affected side. Results: The length of condyle and angle showed significant differences between affected and non-affected sides. However, the length of mandibular body showed insignificant differences. The size differences between affected and non-affected side were observed at the condyle, angle, and body in descending order. Conclusions: This preliminary study suggests that the main etiopathogenic units are condyle and angle in the hemifacial microsomia mandible. Further investigation with the increased number of subjects will be helpful to establish treatment modality by etiopathogenic targeting of hemifacial microsomia.

3-D Inverse Radon Transform by Use of Tree-Structured Filter Bank

  • Morikawa, Yoshitaka;Murakami, Junichi
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -1
    • /
    • pp.184-187
    • /
    • 2002
  • Two-dimensional (2-D) X-ray computerized tomography (CT) equipments are widely used in industrial and medical fields, and nowadays studies on reconstruction algorithm for 3-D cone-beam acquisition systems are active for better utilization. The authors recent-By have proposed a fast reconstruction aigorithm using tree-structured filter bank for 2-D C1, and shown the algorithm is applicable to an approximate reconstruction of 3-D CT. For exact 3-D CT reconstruction, however, we have to backproject 1-D signal into 3-D space. This paper proposes a fast implementation method for this back-projection by use of tree-structured filter bank. and shows the proposed method works approximately 700 times faster than the direct one with almost same reconstruction image quality.

  • PDF

Accuracy of Pedicle Screw Insertion Using Fluoroscopy-Based Navigation-Assisted Surgery : Computed Tomography Postoperative Assessment in 96 Consecutive Patients

  • Lee, Keong Duk;Lyo, In Uk;Kang, Byeong Seong;Sim, Hong Bo;Kwon, Soon Chan;Park, Eun Suk
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권1호
    • /
    • pp.16-20
    • /
    • 2014
  • Objective : Two-dimensional fluoroscopy-based computerized navigation for the placement of pedicle screws offers the advantage of using stored patient-specific imaging data in providing real-time guidance during screw placement. The study aimed to describe the accuracy and reliability of a fluoroscopy-based navigation system for pedicle screw insertion. Methods : A total of 477 pedicle screws were inserted in the lower back of 96 consecutive patients between October 2007 and June 2012 using fluoroscopy-based computer-assisted surgery. The accuracy of screw placement was evaluated using a sophisticated computed tomography protocol. Results : Of the 477 pedicle screws, 461 (96.7%) were judged to be inserted correctly. Frank screw misplacement [16 screws (3.3%)] was observed in 15 patients. Of these, 8 were classified as minimally misplaced (${\leq}2mm$); 3, as moderately misplaced (2.1-4 mm); and 5, as severely misplaced (>4 mm). No complications, including nerve root injury, cerebrospinal fluid leakage, or internal organ injury, were observed in any of the patients. Conclusion : The accuracy of pedicle screw placement using a fluoroscopy-based computer navigation system was observed to be superior to that obtained with conventional techniques.

Implant-Guided Surgery를 이용한 고정성 임플란트 보철물의 전악 수복 증례 (Full mouth rehabilitation with Implant-Guided Surgery and Fixed prosthesis)

  • 김성모;박진홍;류재준;신상완;이정열
    • 대한치과보철학회지
    • /
    • 제56권2호
    • /
    • pp.126-133
    • /
    • 2018
  • Cone beam computerized tomography (CBCT)의 발전은 환자의 해부학적 구조를 3차원적으로 분석할 수 있게 하였다. Surgical guide는 CBCT와 CAD/CAM, 임플란트 진단 소프트웨어의 접목을 통해 미래의 보철물을 계획하고 적합한 위치에 임플란트를 식립할 수 있게 한다. Guided surgery를 통해 해부학적 구조물에 대한 침범을 최소한으로 줄일 수 있고 보다 재현성 있는 치료계획의 설정이 가능하다. 본 증례는 전악 무치악 환자에게 surgical guide를 이용하여 다수의 임플란트를 식립한 증례로 수술시간을 단축시킬 수 있었으며 임시 보철물을 미리 제작함으로써 보다 쉽게 immediate loading을 시행할 수 있었다. 환자는 개선된 안모와 저작기능에 만족하였다.

조기유방암 환자에서 방사선 모의치료 방법의 차이에 따른 심근관류결손의 비교 평가 (Evaluation and Comparison of Myocardial Perfusion Defects in Patients with Early Breast Cancer Subjected to Different Radiation Simulation Techniques)

  • 남지호;기용간;김동원;김원택
    • Radiation Oncology Journal
    • /
    • 제25권1호
    • /
    • pp.26-33
    • /
    • 2007
  • 목 적: 좌측 조기유방암으로 보존수술 후 2차원 또는 3차원 모의치료를 통해 방사선치료를 받은 환자들에서 SPECT (single photon emitted computerized tomography) 영상을 이용하여 심근관류결손의 부위와 빈도를 비교 평가하고자 하였다. 대상 및 방법: 2002년 1월부터 2003년 8월까지 AJCC 병기 T1-T2N0M0인 좌측 조기유방암으로 진단되어 외과에서 보존수술 및 화학요법 후 방사선치료를 시행하였던 32명의 환자들을 대상으로 하였다. X선 투시기를 이용한 2차원 모의치료를 통해 방사선치료를 받은 환자들과 컴퓨터단층촬영 기반의 3차원 모의치료 방법을 이용했던 환자들을 구분하여 연구를 진행하였다. 이들을 대상으로 최소 3년 이상의 추적관찰 기간 후에 technetium-99m-sestamibi gated perfusion SPECT를 시행하여 각 군에서의 심근관류결손의 부위와 빈도를 비교 평가하였고, 각 환자들에서의 심벽의 운동상태와 좌심실의 박출량을 측정하여 분석하였다. 또한 모의치료 과정에서 방사선에 피폭되는 심장영역을 각 군에서 측정하여 심근관류결손과의 상관관계를 알아보았다. 결 과: SPECT 영상 결과, 심근관류결손이 확인된 경우는 전체 32명의 환자 중 11명(34.4%)이었다. 2차원 모의치료를 받은 15명의 환자 중 7명(46.7%)에서, 3차원 모의치료를 받은 17명의 환자 중 4명(23.5%)에서 관류결손이 발견되었는데, 3차원 모의치료를 이용한 환자들에서 심근관류결손의 빈도가 통계적으로 유의하게 낮았다(p=0.0312). 심근관류결손이 확인된 11명 중, 심첨부 결손을 보인 경우가 10명으로 대부분을 차지했다. 심벽의 운동상태와 심실박출량은 모두 정상이었으며, 방사선 조사야에 포함된 심장영역은 3차원 모의치료 군에서 보다 작았으나 양군에서의 심근관류결손과의 통계적 유의성은 확인할 수 없었다. 결 론: 저자들은 이번 연구를 통해 좌측 조기유방암 환자에서 보존수술 후 방사선치료 시 전산화단층촬영 모의치료기를 이용한 3차원 모의치료 방법을 이용하면 심근에 대한 조사용적을 줄일 수 있어 심근관류결손의 빈도를 낮출 수 있음을 확인하였다. 그러나 심근관류스캔상의 결손과 향후 임상적인 허혈성 심장질환으로의 발전 또는 이로 인한 사망률의 증가와의 연관성은 장기간의 추적관찰과 전향적 임상연구를 통해 확인할 필요가 있겠다.

3D CT 동영상 구성을 위한 속도 개선 알고리즘 (The Algorithm Improved the Speed for the 3-Dimensional CT Video Composition)

  • 정찬웅;박진우;전계석
    • 한국음향학회지
    • /
    • 제28권2호
    • /
    • pp.141-147
    • /
    • 2009
  • 본 논문에서는 인체에 유해한 방사능 피폭량이 부챗살 형태의 Fan Beam 보다 상대적으로 적은 원추형 Cone Beam CT 시스템을 사용하여 3차원 영상을 빠르게 구성하기 위한 회전 기반법 알고리즘을 제안하였다. 그리고 계산 속도를 빠르게 하기 위하여 초월함수가 더 적은 3단계 회전 행렬을 이용하여 3차원 영상을 구현하였다. 또한 본 연구에서 구성한 영상을 일반적으로 사용되는 라돈 변환 알고리즘으로 구현된 3차원 영상과 비교하여 영상의 질은 평균적으로 단면 영상 당 10% 정도의 오차를 보이며 미약하게 저하되었으나 영상 구성 속도 면에서는 35배 개선됨을 보였다. 이는 대략 초당 $4{\sim}5$ 프레임을 얻을 수 있는 수치이며 간단한 구조를 가진 피사체라면 보다 많은 프레임을 얻을 수 있어 3차원 동영상을 실시간으로 구현할 수 있는 가능성을 보였다.

3D 동영상획득을 위한 Cone-Beam 형 X-Ray CT 시스템 구현에 관한 연구 (The Study on the Implementation of the X-Ray CT System Using the Cone-Beam for the 3D Dynamic Image Acquisition)

  • 정찬웅;전계석
    • 한국음향학회지
    • /
    • 제28권4호
    • /
    • pp.370-374
    • /
    • 2009
  • 본 논문에서는 3차원 동영상을 구현하기 위하여 인체에 유해한 방사능 피폭량이 부챗살 형태의 Fan Beam 보다 상대적으로 적은 원추형 Cone Beam CT 시스템을 설계하였다. 설계된 시스템은 X-ray가 조사된 각도에서 획득한 데이터를 영상처리부로 전송하고 영상을 구성하는 계산 속도를 빠르게 하기 위하여 초월함수가 보다 적은 3단계 회전 행렬을 이용하여 3차원 영상을 구현하는 회전 기반법을 사용하였다. 본 연구에서는 3차원 영상을 구성하는 시간단축을 통해 초당 3~5장의 영상을 얻음으로써 3차원 동영상을 실시간으로 구현하였다.

시간단축 알고리즘을 통한 3D 동영상 구현 (Implementation of 3D Video using Time-Shortening Algorithm)

  • 신진섭;정찬웅
    • 한국인터넷방송통신학회논문지
    • /
    • 제20권6호
    • /
    • pp.123-128
    • /
    • 2020
  • 본 논문에서는 3차원 동영상을 구현하기 위하여 인체에 유해한 방사능 피폭량이 부챗살 형태의 Fan Beam 보다 상대적으로 적은 원추형 Cone Beam CT 시스템을 설계하였다. 설계된 시스템은 X-ray가 조사된 각도에서 획득한 데이터를 영상처리부로 전송하고 영상을 구성하는 계산 속도를 빠르게 하기 위하여 초월함수가 보다 적은 3단계 회전 행렬을 이용하여 3차원 영상을 구현하는 회전 기반법을 사용하였다. 본 연구에서는 3차원 영상을 구성하는 시간단축을 통해 초당 3~5장의 영상을 얻음으로써 3차원 동영상을 실시간으로 구현하였으며 기존의 데이터 적층 방법에 비해 본 논문에서 사용한 회전 기반법이 우수함을 증명하였으며 단점 및 해결방법 제시하였다.

안면비대칭자의 3차원 전산단층사진 분석에서 경$\cdot$연조직간 비대칭 정도 차이 (Comparison of asymmetric degree between maxillofacial hard and soft tissue in facial asymmetric subjects using three-dimensional computed tomography)

  • 김왕식;이기헌;황현식
    • 대한치과교정학회지
    • /
    • 제35권3호
    • /
    • pp.163-173
    • /
    • 2005
  • 본 연구는 안면비대칭 환자에서 경조직의 비대칭 정도와 연조직 비대칭 정도의 차이를 3차원적으로 밝히고자 시행되었다. 안면비대칭으로 보이는 성인 남녀 34명을 대상으로 두경부 전산단층사진을 촬영하고 3차원 입체영상으로 재구성한 후 기준평면에 대해 비대칭을 나타내는 5개의 계측항목을 경조직에 설정하고, 이에 대응하는 연조직 계측항목을 각각 설정한 후 3차원 계측을 시행하고 경조직과 연조직의 계측항목간 차이를 비교하였다. 이부편위측과 반대측간의 계측치 차이를 비교한 결과, 경조직과 연조직 모두에서 좌우측 계측치간에 통계적으로 유의한 차이가 관찰되었으며 경조직과 연조직의 비대칭 계측항목을 비교한 결과, 6개의 계측항목 모두에서 통계적으로 유의한 차이를 나타내었다. 이부편위를 나타내는 chin deviation, 하악지와 하악골체를 나타내는 frontal ramal inclination difference, frontal corpus inclination difference 항목은 경조직의 비대칭 정도에 비하여 연조직 비대칭 정도가 작게 나타난 반면, 입술경사를 나타내는 lip cheilion height difference, lip canting은 maxillary height difference, occlusal plane canting보다 크게 나타나 입술부위의 비대칭 정도는 하부 경조직의 비대칭 정도보다 큰 것으로 나타났다. 안면비대칭자에서 경조직과 연조직간 비대칭 정도 차이를 규명한 본 연구 결과는 안면비대칭 평가 시 경조직 외에 연조직 계측항목을 이용한 비대칭 분석도 필요함을 시사하였다.