• Title/Summary/Keyword: 3-dimensional computer tomography

Search Result 88, Processing Time 0.023 seconds

Influence of threshold value of computed tomography on the accuracy of 3-dimensional medical model (전산화단층 촬영상의 임계치가 3차원 의학모델 정확도에 미치는 영향에 대한 연구)

  • Lee Byeong-Do;Lee Wan
    • Imaging Science in Dentistry
    • /
    • v.32 no.1
    • /
    • pp.27-33
    • /
    • 2002
  • Purpose: To evaluate the influence of threshold value of computed tomography on the accuracy of rapid prototyping (RP) medical model Material and Methods : CT datas of a human dry skull were transferred from CT scanner via compact disk to a personal computer (PC). 3-dimensional image reconstruction on PC by V-works/sup TM/ 3.0 (CyberMed. Inc.) software and RP models fabrication were followed. 2-RP models were produced by threshold value of 500 and 800 selected in surface rendering process. Linear measurements between arbitrary 12 anatomical landmarks on dry skull, 3-D image model, and 2-RP models were done and compared. Thus, the accuracy of 500 RP and 800RP models was respectively evaluated. Results: There was mean difference (% difference) in absolute value of 2.27 mm (2.73%) between linear measurements of dry skull and 500 RP model. There was mean difference (% difference) in absolute value of 1.94 mm (2.52%) between linear measurements of dry skull and 800 RP model. Conclusion: Slight difference of threshold value in rendering process of 3-D modelling made a influence on the accuracy of RP medical model.

  • PDF

Development of Computer Aided 3D Model From Computed Tomography Images and its Finite Element Analysis for Lumbar Interbody Fusion with Instrumentation

  • Deoghare, Ashish;Padole, Pramod
    • International Journal of CAD/CAM
    • /
    • v.9 no.1
    • /
    • pp.121-128
    • /
    • 2010
  • The purpose of this study is to clarify the mechanical behavior of human lumbar vertebrae (L3/L4) with and without fusion bone under physiological axial compression. The author has developed the program code to build the patient specific three-dimensional geometric model from the computed tomography (CT) images. The developed three-dimensional model provides the necessary information to the physicians and surgeons to visually interact with the model and if needed, plan the way of surgery in advance. The processed data of the model is versatile and compatible with the commercial computer aided design (CAD), finite element analysis (FEA) software and rapid prototyping technology. The actual physical model is manufactured using rapid prototyping technique to confirm the executable competence of the processed data from the developed program code. The patient specific model of L3/L4 vertebrae is analyzed under compressive loading condition by the FEA approach. By varying the spacer position and fusion bone with and without pedicle instrumentation, simulations were carried out to find the increasing axial stiffness so as to ensure the success of fusion technique. The finding was helpful in positioning the fusion bone graft and to predict the mechanical stress and deformation of body organ indicating the critical section.

Computer-aided Design and Fabrication of Bio-mimetic Scaffold for Tissue Engineering Using the Triply Periodic Minimal Surface (삼중 주기적 최소곡면을 이용한 조직공학을 위한 생체모사 스캐폴드의 컴퓨터응용 설계 및 제작)

  • Yoo, Dong-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.7
    • /
    • pp.834-850
    • /
    • 2011
  • In this paper, a novel tissue engineering scaffold design method based on triply periodic minimal surface (TPMS) is proposed. After generating the hexahedral elements for a 3D anatomical shape using the distance field algorithm, the unit cell libraries composed of triply periodic minimal surfaces are mapped into the subdivided hexahedral elements using the shape function widely used in the finite element method. In addition, a heterogeneous implicit solid representation method is introduced to design a 3D (Three-dimensional) bio-mimetic scaffold for tissue engineering from a sequence of computed tomography (CT) medical image data. CT image of a human spine bone is used as the case study for designing a 3D bio-mimetic scaffold model from CT image data.

Classification of Head Shape and 3-dimensional analysis for Korean Men (성인 남성 머리와 얼굴 부위의 형태분류와 3차원적 분석)

  • Choi, Young-Lim;Kim, Jae-Seung;Nam, Yun-Ja
    • Fashion & Textile Research Journal
    • /
    • v.12 no.6
    • /
    • pp.812-820
    • /
    • 2010
  • The objectives of this study were to classify the head shapes of Korean men and to suggest computer tomography as a new body measurement method. The 23 head measurement items of 760 men, aged more than 18 in Sizekorea 2004 database were used to analyze, measured by using statistical methods. Factor analysis, cluster analysis and duncan test were performed using these data. Through factor analysis, 5 factors were extracted upon factor scores and those factors comprised 70.91% for the total variances. The head and face shapes were categorized as 5 types-triangle, round, oval, long, rectangle. We decided for the type 1(triangle) to standard head shape since this type was the most observed. 21 participants were measured using computed tomography(CT). The measured data of skin and skeleton and the standard head shapes were illustrated.

A COMPARATIVE STUDY OF THREE-DIMENSIONAL RECONSTRUCTIVE IMAGES OF TEMPOROMANDIBULAR JOINT USING COMPUTED TOMOGRAM (전산화단층상을 이용한 측두하악관절의 삼차원 재구성상의 비교연구)

  • LIM SUK-YOUNG;KOH KWANG-JOON
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.23 no.2
    • /
    • pp.335-344
    • /
    • 1993
  • The purpose of this study was to clarify the spatial relationship of temporomandibular joint and to an aid in the diagnosis of temporomandibular disorder. For this study, three-dimensional images of normal temporomandibular joints were reconstructed by computer image analysis system and three-dimensional reconstructive program integrated in computed tomography. The obtained results were as follows: 1. Two-dimensional computed tomograms had the better resolution than three dimensional computed tomograms in the evaluation of bone structure and the disk of TMJ. 2. Direct sagittal computed tomograms and coronal computed tomograms had the better resolution in the evaluation of the disk of TMJ. 3. The positional relationship of the disk could be visualized, but the configuration of the disk could not be clearly visualized on three-dimensional reconstructive CT images. 4. Three-dimensional reconstructive CT images had the smoother margin than three-dimensional images reconstructed by computer image analysis system, but the images of the latter had the better perspective. 5. Three-dimensional reconstructive images had the better spatial relationship of the TMJ articulation, and the joint spaces were more clearly visualized on dissection images.

  • PDF

A Handheld Probe Based Optical Coherence Tomography System for Diagnosis of Dental Calculus (치석 진단용 소형 프로브 기반 광간섭단층촬영 시스템)

  • Lee, Chang-Ho;Woo, Chai-Kyoung;Jung, Woong-Gyu;Kang, Hyun-Wook;Oh, Jung-Hwan;Kim, Jee-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.217-222
    • /
    • 2012
  • Optical coherence tomography(OCT) is a noninvasive optical imaging tool for biomedical applications. OCT can provide depth resolved two/three dimensional morphological images on biological samples. In this paper, we integrated an OCT system that was composed of an SLED(Superluminescent Light Emitting Diode, ${\lambda}_0$=1305 nm bandwith= 141 nm), a reference arm adopting a rapid scanning optical delay line(RSOD) to get high speed imaging, and a sample arm that used a micro electro mechanical systems(MEMS) scanning mirror. The sample arm contained a compact probe for imaging dental structures. The performance of the system was evaluated by imaging in-vivo human teeth with dental calculus, and the results indicated distinct appearance of dental calculus from enamel, gum or decayed teeth. The developed probe and system could successfully confirm the presence of dental calculus with a very high spatial resolution($6{\mu}m$).

A Study on the 3D Reconstruction and Representation of CT Images (CT영상의 3차원 재구성 및 표현에 관한 연구)

  • 한영환;이응혁
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.2
    • /
    • pp.201-208
    • /
    • 1994
  • Many three-dimensional object modeling and display methods for computer graphics and computer vision have been developed. Recently, with the help of medical imaging devices such as computerized tomography, magnetic resonance image, etc., some of those object modeling and display methods have been widely used for capturing the shape, structure and other properties of real objects in many medical applications. In this paper, we propose the reconstruction and display method of the three-dimensional object from a series of the cross sectonal image. It is implemented by using the automatic threshold selection method and the contour following algorithm. The combination of curvature and distance, we select feature points. Those feature points are the candidates for the tiling method. As a results, it is proven that this proposed method is very effective and useful in the comprehension of the object's structure. Without the technician's responce, it can be automated.

  • PDF

Hierachical representation of CT images with small memory computer (소용량 컴퓨터에 의한 CT 영상의 계층적 표현)

  • Yoo, S.K.;Kim, S.H.;Kim, N.H.;Kim, W.K.;Park, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1989 no.05
    • /
    • pp.39-43
    • /
    • 1989
  • In this paper, hierachical representation method with a 1-to-4 and 1-to-8 data structure is used to reconstruct the three-dimensional scene from two-dimensional cross sections provided by computed tomography with small memory computer system. To reduce the internal memory use, 2-D section is represented by quadtree, and 3-D scene is represented by octree. Octree is constructed by recursively merging consecutive quadtrees. This method uses 7/200 less memory than pointer type structure with all the case, and less memory up to 60.3% than linear octree with experimental data.

  • PDF

Identification of Fungus-infected Tomato Seeds Based on Full-Field Optical Coherence Tomography

  • Bharti, Bharti;Yoon, Taeil;Lee, Byeong Ha
    • Current Optics and Photonics
    • /
    • v.3 no.6
    • /
    • pp.571-576
    • /
    • 2019
  • The morphological changes of anthracnose (fungus) -infected tomato seeds have been studied to identify the infection and characterize its effect. Full-field optical coherence tomography (FF-OCT) has been utilized as a nondestructive but efficient modality for visualizing the effects of fungal infection. The cross-sectional images extracted from a stack of en face FF-OCT images showed significant changes with infection in the seed structure. First of all, the seed coat disappeared with the infection. The thickness of the seed coat of a healthy seed was measured as 28.2 ㎛, with a standard deviation of 1.2 ㎛. However, for infected seeds the gap between surface and endosperm was not appreciably observed. In addition, the measurements confirmed that the dryness of seeds did not affect the internal seed structure. The reconstructed three-dimensional (3D) image revealed that the permeability of the seed coat, which plays the vital role of protecting the seed, is also affected by the infection. These results suggest that FF-OCT has good potential for the identification of fungus-infected tomato seeds, and for many other tasks in agriculture.

Wavelet-based Noise reduction filter for 3-dimensional Computed Tomography brian angiography (Wavelet을 이용한 CT 3차원 뇌혈관에서의 노이즈 제거 필터 구현)

  • Seong Yeol-Hun;Bak Hyeon-Jae;Kang Hang-Bong
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.11b
    • /
    • pp.859-861
    • /
    • 2005
  • X-ray를 이용한 CT(Computed Tomography : 이하 CT)영상은 사물에 대해 회전하면서 X-ray가 투과하여 감약 정도에 따라서 영상을 획득하지만 검사 목적과는 관계없이 발생되는 통계적인 오차로 인해 정확한 CT영상의 구성을 교란하거나 방해하여 영상의 질을 저하시키고 미세 부분의 관찰 능력을 감소시키는 장해 음영인 아티팩트(artifact)라는 노이즈가 발생한다. 이러한 노이즈를 제거하는 필터를 설계 할 때는 두 가지 고려해야 할 사항이 있는데 첫째는 영상내의 노이즈을 정확히 판단하여 효과적으로 제거해야 하며, 둘째로는 원래의 영상에 가깝도록 경계와 같은 세부 영역을 보존해야 한다는 점이다. 기존에는 mean 필터나 median 필터, 그리고 Gaussian 필터 등을 사용했지만 상세한 부분을 보존하기에는 실패하는 단점이 있다. 따라서 본문에서는 wavelet 변환을 하여 영상의 주파수 대역을 저주파 영역과 고주파 영역으로 분리하여 각각의 영역에서 노이즈를 제거할 수 있도록 적합한 필터를 설계하고 방법을 제안하여 그 필터를 CT 3차원 뇌혈관 영상에 적용하여 많은 노이즈를 제거하였고 낮은 Threshold값에서도 작은 혈관을 관찰 할 수 있었다.

  • PDF