• Title/Summary/Keyword: 3-arm type

Search Result 257, Processing Time 0.025 seconds

A Chromosomal Study on the Genus Cobitis (Pisces : Cobitidae) in the Southern Part of Korea (한국 남부지방에 서식하는 기름종개속(Cobitis) 어류의 핵형 비교)

  • KIM Ik-Soo;LEE Ji-Hyun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.19 no.3
    • /
    • pp.257-264
    • /
    • 1986
  • The Chromosomes of five cobitid fishes, Cobitis taenia taenia, C. taenia lutheri, C. taenia striata, C. longicorpus and C. koreensis were studied. The karyotypic studies were based on the observations from the flame-drying preparations. The results obtained such as the number of somatic chromosomes, the type of chromosomes according to the centromeric loci and the number of chromosomal arm(AN) were as follows: C. longicorpus, 2n=50, 12m-8sm-30a, AN=70; C. koreensis, 2n=50, 10m-12sm-28a, AN=72; C. taenia taenia, 2n=48, 14m-4sm-30a, AN=66: C. taenia lutheri, 2n=50, 10m-6sm-34a, AN=66; and C. taenia striata, 2n=50, 10m-6sm-34a, AN=66. Peculiarly, in the case of C. taenia lutheri the chromosome number of somatic diploid was found to be 48-51, however, the number of chromosomal arm was 66, irrespective of the difference in the numbers of each somatic genome. It was confirmed there exists the Robertsonian event, one of the chromosomal polymorphism in C.t. lutheri. It was remarked taxonomically that the karyotype of C. taenia taenia of Korea having 48 diploid chromosomes was not identical with that of Europe and Japan with 50 chromosomes. Based on the karyotype analysis the Korean cobitid fishes can be classified roughly into three species groups according to arm numbers and diploid numbers; 1) C. taenia taenia, C. taenia lutheri, C. taenia striata 2) C. koreensis, C. longicor pus, C. rotundicaudata and 3) C. granoei.

  • PDF

Analysis on Torso Somatotype of Adult Females by Tight Fitting Technique (입체재단에 의한 성인여성의 체간부 유형분석)

  • 홍정민
    • Journal of the Korean Society of Costume
    • /
    • v.42
    • /
    • pp.163-172
    • /
    • 1999
  • The purpose of this study is to classify the types of torso of adult females using the tight fitting technique and pattern development figure. The subjects are 106 females of 19 to 24 years old. 59 different items are measured from body surface development and analyzed by factor analysis and cluster analysis. The results are as follows; 1. Eight somatotype factors are obtained through factor analysis and orthogonal rotation by the method of Varimax Factor 1 is the length of upper body factor 2 the length of lower body factor 3 the circumference and width of the back of upper body factor 4 the circumference and width of front torso factor 5 the dart type of the back of upper body factor 6 the size of the back neck factor 7 the type of the front shoulder and factor 8 the size of the back arm hole. 2. As a result of cluster analysis the somatotype of torso is classified into 5 types. Type 1 is normal in length circumference and width of upper body. Type 2 is shortest length circumference and width of torso. Type 3 is long in length circumference and width of torso. Type 4 is normal length and short in circumference and width especially short in bust circumference. Type 5 is longest in length circumference and width of torso.

  • PDF

Mid-Term Results of Thoracic Endovascular Aortic Repair for Complicated Acute Type B Aortic Dissection at a Single Center

  • Hong, Young Kwang;Chang, Won Ho;Goo, Dong Erk;Oh, Hong Chul;Park, Young Woo
    • Journal of Chest Surgery
    • /
    • v.54 no.3
    • /
    • pp.172-178
    • /
    • 2021
  • Background: Complicated acute type B aortic dissection is a life-threatening condition with high morbidity and mortality. The aim of this study was to report a single-center experience with endovascular stent-graft repair of acute type B dissection of the thoracic aorta and to evaluate the mid-term outcomes. Methods: We reviewed 18 patients treated for complicated acute type B aortic dissection by thoracic endovascular aortic repair (TEVAR) from September 2011 to July 2017. The indications for surgery included rupture, impending rupture, limb ischemia, visceral malperfusion, and paraplegia. The median follow-up was 34.50 months (range, 12-80 months). Results: The median interval from aortic dissection to TEVAR was 5.50 days (range, 0-32 days). There was no in-hospital mortality. All cases of malperfusion improved except for 1 patient. The morbidities included endoleak in 2 patients (11.1%), stroke in 3 patients (16.7%), pneumonia in 2 patients (11.1%), transient ischemia of the left arm in 1 patient (5.6%), and temporary visceral ischemia in 1 patient (5.6%). Postoperative computed tomography angiography at 1 year showed complete thrombosis of the false lumen in 15 patients (83.3%). Conclusion: TEVAR of complicated type B aortic dissection with a stent-graft was effective, with a low morbidity and mortality rate.

A Deep Optical Photometric Study of the Massive Young Open Clusters in the Sagittarius-Carina Spiral Arm

  • Hur, Hyeonoh
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.44.1-44.1
    • /
    • 2016
  • The Sagittarius-Carina spiral arm in the Galaxy contains several massive young open clusters. We present a deep optical photometric study on the massive young open clusters in the Sagittarius-Carina arm, Westerlund 2 and the young open clusters in the ${\eta}$ Carina nebula. Westerlund 2 is a less studied starburst-type cluster in the Galaxy. An abnormal reddening law for the intracluster medium of the young starburst-type cluster Westerlund 2 is determined to be $R_{V,cl}=4.14{\pm}0.08$. The distance modulus is determined from zero-age main-sequence fitting to the reddening-corrected color-magnitude diagrams of the early-type members to be $V_0-M_V=13.9{\pm}0.14mag$. The pre-main sequence (PMS) members of Westerlund 2 are selected by identifying the optical counterparts of X-ray emission sources from the Chandra X-ray observation and mid-infrared emission sources from the Spitzer/IRAC (the Infrared Array Camera) observation. The initial mass function (IMF) shows a slightly flat slope of ${\Gamma}=-1.1{\pm}0.1$ down to $5M_{\odot}$. The age of Westerlund 2 is estimated to be. 1.5 Myr from the main-sequence turn-on luminosity and the age distribution of PMS stars. The ${\eta}$ Carina nebula is the best laboratory for the investigation of the Galactic massive stars and low-mass star formation under the influence of numerous massive stars. We have performed deep wide-field CCD photometry of stars in the ${\eta}$ Carina nebula to determine the reddening law, distance, and the IMF of the clusters in the nebula. We present VRI and $H{\alpha}$ photometry of 130,571 stars from the images obtained with the 4m telescope at Cerro Tololo Inter-American Observatory (CTIO). RV,cl in the η Carina nebula gradually decreases from the southern part (~4.5, around Trumpler 14 and Trumpler 16) to the northern part around Trumpler 15 (~3.5). Distance to the young open clusters in the ${\eta}$ Carina nebula is partly revised based on the zero-age main-sequence fitting to the reddening-corrected color-magnitude diagrams (CMDs) and the (semi-) reddening-independent CMDs. We select the PMS members and candidates by identifying the optical counterparts of X-ray sources from the Chandra Carina Complex Survey and mid-infrared excess emission stars from the Spitzer Vela-Carina survey. From the evolutionary stage of massive stars and PMS stars, we obtain that the northern young open cluster Trumpler 15 is distinctively older than the southern young open clusters, Trumpler 14 (${\leq}2.5 Myr$) and Trumpler 16 (2.5-3.5 Myr). The slopes of the IMF of Trumpler 14, Trumpler 15, and Trumpler 16 are determined to be $-1.2{\pm}0.1$, $-1.5{\pm}0.3$, and $-1.1{\pm}0.1$, respectively. Based on the RV,cl of several young open clusters determined in this work and the previous studies of our group, We suggest that higher RV,cl values are commonly found for very young open clusters with the age of < 4 Myr. We also confirm the correlation between the slope of the IMF and the surface mass density of massive stars.

  • PDF

Preparation of Controlled Release Spheronized Beads by a Simple Extrusion and Modified Spheronization Process

  • Lee, Si-Beum;Kim, Min-Soo;Jun, Seoung-Wook;Park, Jeong-Sook;Hwang, Sung-Joo
    • Archives of Pharmacal Research
    • /
    • v.28 no.5
    • /
    • pp.619-625
    • /
    • 2005
  • Beads loaded with the water-soluble drug, phenylpropanolamine HCl (PPA), were prepared using an extruder and double arm counter-rotating roller modified from a traditional pill machine. The mean diameter of the cylindrical rod-like extrudate from the ram extruder was 3 mm; that of the uncoated bead after cutting and spheronization by the modified double arm counter-rotating roller was 3.26~3.28 mm. Although the surface of the beads was moderately rough and irregular, some exhibited hump-shaped protrusions, the sphericity was acceptable (roundness 1.15) and adequate for the subsequent coating process. An increase in mean diameter of the coated beads and improvements in friability and sphericity were observed in proportion to the amount of coating material applied (ethylcellulose or Eudragit?? RS 100). It was also found that the release rate of PPA from the coated beads could be controlled by the amount and type of coating materials applied or with the incorporation of Eudragit ?? RS 100 into the core matrix. Further modifications to the double arm counter-rotating roller, including adjustment of the rotation speed and distance between the rollers, would yield smaller uncoated beads with improved roundness and surface roughness. In conclusion , the present method could be potentially applied to prepare controlled release drug delivery beads or pellet dosage forms.

Eddy current brake type dynamometer (와류제동형동력계)

  • 성찬용
    • 전기의세계
    • /
    • v.17 no.3
    • /
    • pp.62-63
    • /
    • 1968
  • 전동기의 특성측정법은 여러가지가 있으나 소형전동기의 부하시험을 하고저 할때는 보통 Prony Brake가 사용되고 있다. 이 Prony Brake를 사용하신 분은 누구든지 경험하듯이 냉각수의 공급이 곤란하며 산수가 되어 시험장소에 물바다가 되며 Balance가 되더라도 Arm의 진동으로 저울의 눈금을 읽기가 곤란하여 정확한 특성산출에 지장을 초래하고 있다. 금반 폐공장에서 상기의 곤란한 점을 제거하고 간편하고 효율좋은 실부하시험기를 제작 사용하여 다대한 성과를 올리고 있기에 그 구조와 사용방법을 소개하고저 한다.

  • PDF

Clinical Study of Atopic Dermatitis ; the Classification of Oriental Medical Clinical type and Treatment (아토피 피부염 환자에 대한 임상적 연구; 한의학적인 임상유형분류 및 치료)

  • 윤화정;고우신
    • The Journal of Korean Medicine
    • /
    • v.22 no.2
    • /
    • pp.10-21
    • /
    • 2001
  • Objectives : Atopic dermatitis(AD) assume an remarkable clinical aspect and it s diagnosis almost depends on clinical symptoms. Therefore, we aimed to study the clinical diagnostic standard of AD for more accurate treatment. We repert as follows; Methods : For 6 months from March to August in 2000 we selected fifty outpatients who were prognosis of AD in the department of dermatology, Oriental medical hospitol, Dong-eui University. Results and Conclusions : 1. We classified of the grade, the condition of AD patient was slight and severe, by the sum of total by the clinical index of AD (diagnostic features). 2. By consulting previous oriental medical theories, we divided symptom-complex of AD into two type ; one was damp-heat type and the other was deficiency of blood- wind-dryness type. 3. Male to female ratio was 17 : 33 and the third stage, more than half of the patients were adolescents. 4. According to the results of symptom-complex of AD patients, on the first examination damp-heat type was more than deficiency of blood-wind-dryness type and in progressing treatment, the condition has been change to deficiency of blood-wind-dryness type. 5. In the lesions of AD, arm and knee were most serious skin lesions and in symptoms of AD, pruritus was most complained, and in progressing treatment, erosion and erythema were greatly improved. 6. When we measured the levels of serum Total IgE, that of thirty eight patientswere higher than that of normal, but elevation of serum IgE levels was not correlated with the severity of AD.

  • PDF

A Comparison of Body Types Between Korean and Mongolian Women within the 18 to 24 Age Group(Part I) (18~24세 한국과 몽골여성 체형비교(제1보))

  • Kwon, Soon-Jung;Hong, Jung-Min
    • Fashion & Textile Research Journal
    • /
    • v.6 no.5
    • /
    • pp.625-633
    • /
    • 2004
  • A comparison between the body types of Korean and Mongolian women was made and analyzed to provide a foundation for securing the Mongolian fashion market. 404 adults within the 18 to 24 age group were studied. From the results of comparing 27 items of direct anthropometric measurements, 15 items were shown to have significant differences. Mongolian women were larger in values for 13 items than were Korean women except two items, which are back waist length and arm length. From the results of comparing 25 items of index values, 19 items were shown to have significant differences. The comparison of the anatomical proportions showed that the lower half of Mongolian women's bodies were longer and their shoulder and hips were wider than those of Korean women. Based on these direct anthropometric measurements and index values, Korean and Mongolian women were categorized into 4 Types; Type 1 is average body type with tall height and longer lower half of the body. Type 2 is slimmer body type with average height. Type 3 is average body type with shorter height. Lastly, type 4 is obese body type with average height.

A STUDY OF THE TENSILE LOAD OF SEVERAL CLASPS ACCORDING TO VARIOUS UNDERCUT AREA (수종의 클래스프의 언더커트에 따른 인장력에 관한 연구)

  • Kim, Boong-Hwan;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.3
    • /
    • pp.470-485
    • /
    • 1997
  • A fundamental principle in clasp selection for a specific abutment is the reduction of the transmission of excessive forces to the abutment tooth. Those forces include tilting, tipping, and stress on the abutment tooth. The flexibility of a clasp was believed to directly affect the reduction of such forces. Opinions have been expressed concerning the proper type of clasp to be used to prevent stress on periodontium. In order to evaluate and compare the various designs of a clasp system, it is necessary to measure these forces. This study compared the average measurements of forces required to dislodge three kinds of circumferential clasps having different amount of undercuts : the first with a round retentive arm, the second with a half round retentive arm, the third with a wrought wire retentive arm under tensile load. Three commonly used undercuts( 0.01, 0.02, 0.03 inch) were created on nine cast crowns, premolars and molars. The test was run six times for a same clasp. The means of tensile load required to dislodge each of the different clasps were compared statistically using the ANOVA test and multiple range test (Duncan test). The results were as follows. 1. The amount of tensile load of the wrought wire clasp was significantly different from the cast round or half round clasp (p<0.05). 2. The more amount of the undercut, the more tensile load was needed to dislodge the clasps. There were significant differences among them (p<0.05). 3. The molar showed higher tensile load than the premolar, and there was significant difference (p<0.05). 4. The means of tensile load according to clasp types showed significant differences at the molar between wrought wire clasp and cast clasp (p<0.05), but did not at the premolar.

  • PDF

Arthroscopic-assisted Reduction and Percutaneous Screw Fixation for Glenoid Fracture with Scapular Extension

  • Kim, Se Jin;Lee, Sung Hyun;Jung, Dae Woong;Kim, Jeong Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.3
    • /
    • pp.147-152
    • /
    • 2017
  • Background: To evaluate the clinical and functional outcomes of arthroscopic-assisted reduction and percutaneous screw fixation for glenoid fractures with scapular extension, and investigate the radiologic and clinical benefits from the results. Methods: We evaluated patients treated with arthroscopic-assisted reduction and percutaneous screw fixation for glenoid fractures with scapular extension from November 2008 to September 2015. Fractures with displacement exceeding one-fourth of the anterior-articular surface or more than one-third of the posterior-articular surface in radiographic images were treated by surgery. Clinical assessment was conducted based on range of motion, Rowe score, and Constant score of injured arm and uninjured arm at last follow-up. Results: Fifteen patients with Ideberg classification grade III, IV, and V glenoid fracture who underwent arthroscopic-assisted reduction using percutaneous screw fixation were retrospectively enrolled. There were no differences in clinical outcomes at final follow-up compared to uninjured arm. Bone union was seen in all cases within five months, and the average time to bone union was 15.2 weeks. Ankylosis in one case was observed as a postoperative complication, but the symptoms improved in response to physical therapy for six months. There was no failure of fixation and neurovascular complication. Conclusions: We identified acceptable results upon radiological and clinical assessment for the arthroscopic-assisted reduction and percutaneous fixation. For this reason, we believe the method is favorable for the treatment of Ideberg type III, IV, and V glenoid fractures. Restoration of the articular surface is considered to be more important than reduction of fractures reduction of the scapula body.