• 제목/요약/키워드: 3-arm type

검색결과 257건 처리시간 0.024초

런닝형 브래지어의 비교분석 (Comparative analysis of running-type brassieres on the market)

  • 박도윤;정혜순;나미향
    • 복식문화연구
    • /
    • 제20권5호
    • /
    • pp.621-634
    • /
    • 2012
  • With comparative analysis of running-type brassieres on the market about suitability for middle-aged women, this study is to provide basic data of running-type brassieres' pattern which is highly suitable. In the pursuit of this purpose, this study carried out wearing experiment targeting 3 middle-aged women with normal body shape which is 85B of chest circumference. The result is as follows. The significant difference was recognized in the breast. The products were rated in order of C>A>B>D, E, F, G>H by the observers, and C>B>D>A>F>E=G>H by the subjects. The significant difference was recognized in the armhole area. The products were ranked in the order of C, D>B, G, E>A, F, H by the observes and D, C>B>G>F>A>H by the subjects. The significant difference was also recognized in 6 categories(14~19) for the torso. According to the overall average values, the products were rated in the order of B, C, D>A, D, F, G by the observers and B=D>C>H>F>G>A>E by the subjects. The overall evaluation exhibited the significant difference. The products were ranked in the order of D>C>E>B>H>A>G>F by both observers and subjects. Therefore it was confirmed that the product D was appropriate in general. To conclude of comparative analysis about 8 kinds of running-type brassieres on the market, the average values of the product C and D in all categories had high marks for each category. The product C was comfortable and capable of covering the breast well, however, a gap was formed in outside-up part. The product D, made from lacy fabric, was very comfortable and well-fitted but there was inconsistency between the mold-cup and the breast shape.

자동차 조립공정에서 공기압력식 진동공구의 국소진동평가 (Assessment of Vibration Produced by Pneumatic Hand Tools Used in Automobile Assembly)

  • 김선술;백남원
    • 한국산업보건학회지
    • /
    • 제6권1호
    • /
    • pp.1-16
    • /
    • 1996
  • This study was conducted at an automobile assembly line located in Kyonggi-do, Korea from January 16 to February 28, 1995. The purposes of this study were to assess worker exposures to hand-arm vibration and the performance of gloves for reduction of vibration. The exposure to vibration was measured using to the ISO 5349(1986) method. Vibration acceleration and frequency spectra for each tool were determined on-line replicating actual working conditions and analyzed together with exposure time for evaluating individual worker exposure. Eight pneumatic hand tools, 60 workers exposured to hand-arm vibration, and three pairs of gloves were involved in this study. Results are summarized as follows. 1. Dominant frequencies of vibration for all tools(n=8) measured in this study ranged from 250 Hz to 800 Hz. 2. There was no significant correleration between dominant frequencies and free running speed (p>0.05). 3. Total predicted exposure times of using impact, hammer type did not exceed 40 minutes, but metal finish task, using grinder and sander exceeded 40 minutes. Total exposure time affected significantly the frequency-weighted, 4 hr equivalent acceleration. 4. Predicted prevalence and observed exposure period data were compared in workers(n=60), according to ISO 5349. In this results, 23(50.0 %) and 24(48.07 %) persons exceeded the mean latency periods for vibration-induced white finger(VWF) at 10 % (n=46) and 50 % (n=52) standards, respectively. On the basis of ISO equation, mean latent periods for VWF were 3.23, 4.72 years at 10 %, 50 % standards, respectively. 5. Reduction of vibration by gloves was evaluated. Since impact pneumatic tools produced low frequency vibrations, conventional gloves did not provide any protection. Gloves A and C amplify somewhat the signal at frequency below 400 Hz; the attenuation increases progressively by frequency to reach 18 dB ($7.94{\times}10^{-6}m/s^2$) at 1,000 Hz, slightly worsening Glove B did not provide any protection and made the situation slightly worse. However, since they make the hands warm, the occurrence of vibration-induced white fingers may be reduced.

  • PDF

개방형 로봇 플랫폼 기반 미세수술로봇의 안전성 및 성능평가에 관한 연구 (A Study on Safety and Performance Evaluation of Micro - surgical Robots Based on Open Robot Platform)

  • 박준현;호예지;이덕희;최재순
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권5호
    • /
    • pp.206-214
    • /
    • 2019
  • Surgical methods and associated precision systems have been developed, but surgical procedures that require precise location and fine manipulation of the lesion remain a limitation. The combination of precision robot manipulation technology and 3D medical image navigation technology overcomes the limitations of minimally invasive surgery (MIS) and enables a more stable and successful operation. Surgical robots are surgical robots such as da Vince, and surgical robots using industrial robotic arms. There are various developments and researches of medical robots. In recent medical robot development, a new type of surgical robot based on an industrial robot arm capable of easily replacing the end effector according to the user's needs is being actively developed at home and abroad. Therefore, in this study, we developed safety and performance evaluation guideline for micro - surgical robots based on open robot platform using general purpose robot arm to help quality control of the medical device.

Comparison Study for Body Composition and Physical Function Fitness to the According of Exercise Type in Elderly Women

  • Lee, Jin-wook
    • 한국컴퓨터정보학회논문지
    • /
    • 제26권4호
    • /
    • pp.133-142
    • /
    • 2021
  • 본 연구의 목적은 여성노인을 대상으로 모던댄스, 아쿠아로빅, 복합운동 프로그램을 실시한 후 신체조성과 신체기능체력에 대한 변화 비교하여 여성노인에게 가장 적합한 운동이 무엇인지를 살펴보고자 실시되었다. 연구의 대상자는 J도에 거주하는 노인여성 47명을 대상으로 MDG(n=13) AEG(n=11), CEG(n=11), CG(n=12)을 무작위로 집단을 모집하여 12주간 주3회 1시간씩 운동을 실시하였다. 이 연구의 결과 통제그룹에 비해 grip strength, chair stand, arm curl, 2 minute step, 244cm up and go에서 유의한 차이를 보였으며, Back scratch는 MDG와 CEG에서만 운동 후 유의하게 감소하였으나 Chair sit and reach에서는 변화가 보이지 않았다. 본 연구결과 운동그룹 중 모던댄스(MDG)가 운동 후 가장 많은 신체기능체력이 향상된 것으로 나타났으며, 노인들에게 유연성과 관절의 가동성을 증진 시킬 수 있는 추가적인 운동프로그램이 필요하다. 또한 자신의 흥미에 맞는 운동을 자발적으로 참여하여 지속성 있게 하는 것이 중요할 것으로 생각된다.

휘어짐센서와 관성센서를 이용한 손가락을 포함한 상지 운동 검출 (Upper Limb Motion Detection Including Fingers Using Flex Sensors and Inertial Sensors)

  • 김연준;유재하;김동연;김수찬
    • 융합신호처리학회논문지
    • /
    • 제21권3호
    • /
    • pp.101-106
    • /
    • 2020
  • 가상현실의 활용도는 게임뿐만 아니라 재활 치료와 같은 의료에서도 높아지고 있다. 편리성으로 인하여 비디오를 활용한 비접촉 방식과 핸드 헬드 타입의 마우스 등을 사용하여 상지 움직임을 감지한다. 본 논문에서는 접힌 정도에 따라 저항값이 변화되는 휘어짐센서와 공간에서의 방향 정보를 얻을 수 있는 관성센서를 사용하여 손가락 움직임과 함께 상지 동작도 획득할 수 있는 장갑을 구현하였다. 구현된 장갑에서 얻은 신호로 오픈 소스 플랫폼인 Processing을 사용하여 손가락 움직임을 포함한 상지 동작을 실시간으로 표현하였다. 각 손가락 움직임의 감도는 0.5deg, 상지 동작 감도는 0.6deg였다.

어깨관절 질환에 대한 관절가동술 유형의 연구 동향 : 주제범위 문헌고찰 (Research Trend of Joint Mobilization Type on Shoulder : A scoping review)

  • 이정우;이남기
    • 대한통합의학회지
    • /
    • 제11권3호
    • /
    • pp.171-183
    • /
    • 2023
  • Purpose : This study sought to investigate research trends regarding joint mobilization type among patients with shoulder joint diseases. Methods : A scoping review was conducted according to the five steps outlined by Arskey and O'Malley and PRISMA-ScR. We searched six domestic databases (ScienceOn, DBpia, Riss, Kmbase, Kiss, KCI) and three international databases (CINAHL, Pubmed, Cochrane central) between 2013 and June 2023. The keyword terms used were 'joint mobilization', 'Kaltenborn', 'Maitland', 'Mulligan', and 'shoulder joint'. Results : There were a total of 44 studies that investigated the topic, and these were divided into quantitative analysis and topic analysis. In terms of publication year, the number of studies within the last five years has increased more than compared to the previous five years, with most of them being randomized clinical trials. In shoulder joint diseases, it was found that the majority of joint movement studies focused on adhesive joint cystitis and shoulder collision syndrome. The Mulligan concept was the most commonly studied type of joint motion. The dependent variables used included pain, joint function (disability), and muscle function. The visual analog scale was the most commonly used for the pain variable, followed by the numeric rating scale. For joint function and disability variables, range of motion was the most commonly used, followed by shoulder pain and disability index, and disabilities of the arm, shoulder, and hand. For muscle function, variables such as muscle tone, strength, and activity were used. Conclusion : We believe that findings of this scoping review can serve as valuable mapping data for joint mobilization research on shoulder joint diseases. Further studies including systematic reviews and meta-analyses based on these results are recommended.

3-DCS를 이용한 자동차 공기 분배장치의 도아 구동 기구의 공차 적합성 분석에 대한 연구 (Study of Tolerance Suitability of Door Operation Mechanism on Mobile Air Handing Unit Using 3-DCS Analysis)

  • 김종수;이대웅
    • 한국자동차공학회논문집
    • /
    • 제24권5호
    • /
    • pp.527-537
    • /
    • 2016
  • Recent automakers are trying to be more precise with the dimension check and moving parts to guarantee high quality and satisfy customer requirements. The aim of this paper is to investigate the design tolerance suitability of door operating mechanism linked arms, lever, and cam-shaft in a mobile air handling unit. These parts are complicated because doors, arms, lever and cam-shaft are connected nonlinearly in 3D. The current tolerance analysis method poses problems in design analysis because the moving doors are reasonably suitable for the AHU function. The 3-DCS analysis method provided useful results not only in establishing the inspection criteria for the quality control of products but also in enabling economical production. As a result, the vent door had $1.62^{\circ}{\sim}1.72^{\circ}$ and the defrost door had $0.84^{\circ}{\sim}0.9^{\circ}$ for the directly connected arms operating-type. For the lever connected arm operating-type, the foot door had $2.0^{\circ}{\sim}2.24^{\circ}$ tolerance, while the tolerance values satisfied the air flow volume distribution rate criteria in the AHU. Finally, the results have confirmed the design's tolerance suitability by using 3-DCS analysis at the early design stages. Reliability can be achieved by analyzing accumulated tolerance during the sub-parts assembly process and the moving mechanism linked especially by arms, lever, and cam-shaft.

광원의 종류에 따른 광역동 치료시의 Streptococcus mutans에 대한 항균 효과 (Antimicrobial Effect on Streptococcus mutans in Photodynamic Therapy using Different Light Source)

  • 김재용;박호원;이주현;서현우;이시영
    • 대한소아치과학회지
    • /
    • 제45권1호
    • /
    • pp.82-89
    • /
    • 2018
  • 본 연구의 목적은 치면세균막 착색제인 erythrosine을 광감각제로 사용하여 S. mutans에 광역동 치료를 시행하였을 때, 동일한 에너지량을 조사시 광원의 종류에 따른 항균능의 차이를 비교해보고자 함이다. S. mutans를 각각 planktonic 상태와 biofilm 상태로 형성한 후 $40{\mu}M$로 희석한 erythrosine을 3분간 처리한 다음 광원의 종류로 Halogen, LED, Plasma arc를 사용하였고 각각 30초, 15초, 9.5초의 광조사를 시행하였다. 실험 종료 후 각 실험군의 CFU를 측정하여 각 조건에 따른 광역동 치료 효과를 비교하였다. 각 실험군의 CFU는 통계적으로 유의한 차이가 없었다. 동일 에너지량을 조사시 광역동 치료의 효과는 광원의 종류와 관계없이 동일하다고 할 수 있으며, 이는 다양한 광 조사 기기를 가진 임상현장에서도 유용한 결과라 할 수 있다.

매개변수를 이용한 $Labview^{(R)}$ 기반의 3축 SCARA로봇의 이종모션 제어 알고리즘 (Hybrid Motion Blending Algorithm of 3-Axis SCARA Robot based on $Labview^{(R)}$ using Parametric Interpolation)

  • 정원지;주지훈;이기상
    • 한국공작기계학회논문집
    • /
    • 제18권2호
    • /
    • pp.154-161
    • /
    • 2009
  • In order to implement continuous-path motion on a robot, it is necessary to blend one joint motion to another joint motion near a via point in a trapezoidal form of joint velocity. First, the velocity superposition using parametric interpolation is proposed. Hybrid motion blending is defined as the blending of different two type's motions such as blending of joint motion with linear motion, in the neighborhood of a via point. Second, hybrid motion blending algorithm is proposed based on velocity superposition using parametric interpolation. By using a 3-axis SCARA (Selective Compliance Assembly Robot Arm) robot with $LabVIEW^{(R)}$ $controller^{(1)}$, the velocity superposition algorithm using parametric interpolation is shown to result in less vibration, compared with PTP(Point- To-Point) motion and Kim's algorithm. Moreover, the hybrid motion $algorithm^{(2)}$ is implemented on the robot using $LabVIEW^{(R)(1)}$ programming, which is confirmed by showing the end-effector path of joint-linear hybrid motion.

혈액투석중인 만성신부전환자의 영양상태에 관한 연구 (Nutritional Assessment of the Hemodialysis Patients)

  • 김성미
    • Journal of Nutrition and Health
    • /
    • 제33권2호
    • /
    • pp.179-185
    • /
    • 2000
  • This study investigated the nutritional status of 33 hemodialysis patients. Their weight, height, triceps and mid-arm circumference were measured and their dietary intake and blood profiles evaluated. The subjects were 57.1$\pm$11.9 years old. The energy intakes of men and women were 61% and 68% of RDA, respectively. The men and women's intake of protein was 0.93g/IBWkg/d and 0.99g/IBWkg/d, respectively. According to the distribution of BMI, 22.2% of the men and 73.3% of the women were underweight. A total of 5.6% of the men were overweight, versus none of the women. The serum albumin levels of the men and women were 3.56 and 3.52g/dl, respectively. The serum cholesterol levels of the men and women were 134.1 and 148.5mg/dl, respectively. The subjects were divided into three groups according to the level of albumin, and their intakes of nutrients were compared with one another. The group with high levels of albumin did not show higher energy and protein intake than the other groups but the serum total protein level was significantly higher. When the nutritional status of the patients was evaluated by weight and serum albumin level, 6.0% of them showed kwashiorkor-type malnutrition and 75.8% of them showed mild malnutrition.