• 제목/요약/키워드: 3-Dimensional Resolution

검색결과 540건 처리시간 0.025초

One-dimensionally Ordered Array of Co and Fe Nanoclusters on Carburized-W(110) via Template Assisted Self-Assembly

  • Kim, Ji-Hyun;Yang, Serlun;Kim, Jae-Sung;Lukashev, Pavel;Rojas, Geoffrey;Enders, Axel;Sessi, Violetta;Honolka, Jan
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.135-136
    • /
    • 2012
  • Carbon atoms near the surface of W(110) induce reconstructions such as $R(15{\times}12)$ -C/W(110) which consists of two characteristic parts, one square shaped and bright protrusion and two smaller ones. In the atomic resolution STM image, the bigger protrusion shows the periodicities of clean W(110), indicating that it is almost carbon poor region. The smaller protrusion contains hexagonal carbide surface layer of ${\alpha}$-W2C on W(110). Employing this carburized W(110) as templates, we grow Co and Fe clusters of less than ten atoms. Due to the selectivity of bonding sites, growth of larger cluster is highly unfavorable for Co and the size of clusters is very uniform. Since Co atoms prefer to sit on the bigger protrusion rather than smaller one, Co cluster can be arranged one-dimensionally in $R(15{\times}12)$-C/W(110) with quite uniform size distribution. However, Fe clusters sit on both sites without favored site, but still with uniform size distribution. On the other hand, Fe clusters can be grown with quasi one-dimensional order in $R(15{\times}3)$-C/W(110), which consists of only smaller protrusions. We investigate the magnetic properties of the ordered nano-sized clusters. Experiments using XMCD reveals little magnetic moment of Co cluster on $R(15{\times}12)$-C/W(110). This observation is consistent with the predictions of our first principles calculations that small Co clusters can be nonmagnetic or antiferromagnetic with low mean magnetic moment per atom.

  • PDF

Determination of global ice loads on the ship using the measured full-scale motion data

  • Lee, Jae-Man;Lee, Chun-Ju;Kim, Young-Shik;Choi, Gul-Gi;Lew, Jae-Moon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제8권4호
    • /
    • pp.301-311
    • /
    • 2016
  • This paper describes the whole procedures to determine ice-induced global loads on the ship using measured full-scale data in accordance with the method proposed by the Canadian Hydraulics Centre of the National Research Council of Canada. Ship motions of 6 degrees of freedom (dof) are found by processing the commercial sensor signals named Motion Pak II under the assumption of rigid body motion. Linear accelerations as well as angular rates were measured by Motion Pak II data. To eliminate the noise of the measured data and the staircase signals due to the resolution of the sensor, a band pass filter that passes frequencies between 0.001 and 0.6 Hz and cubic spline interpolation resampling had been applied. 6 dof motions were computed by the integrating and/or differentiating the filtered signals. Added mass and damping force of the ship had been computed by the 3-dimensional panel method under the assumption of zero frequency. Once the coefficients of hydrodynamic and hydrostatic data as well as all the 6 dof motion data had been obtained, global ice loads can be computed by solving the fully coupled 6 dof equations of motion. Full-scale data were acquired while the ARAON rammed old ice floes in the high Arctic. Estimated ice impact forces for two representative events showed 7e15 MN when ship operated in heavy ice conditions.

Analysis of Coast Topography by RTK GPS and Echo Sounder

  • Lee, Jea-One;Kim, Jin-Soo
    • Korean Journal of Geomatics
    • /
    • 제2권1호
    • /
    • pp.57-64
    • /
    • 2002
  • Measuring the depth of water is very important in ensuring the protection and safety of seaside. There are many difficulties in making the contour bathymetric map, and contour line due to the limitation of continuous measurement of water depth and collimation with the conventional measuring and positioning methods. But the real-time kinematic GPS (RTK GPS) positioning using a carrier phase enables us to decide a precise position without breaking a signal even under the condition of a moving environment. It is also possible to obtain an accurate depth of water in real time with a fathometer through the measuring of time delay between sending and receiving epochs. This research aims at investigation of accuracy potential of RTK GPS in combination with Echo Sounder(E/S) for the coastal mapping. Apart from this purpose, the accuracy of ambiguity resolution with the OTF(On the Fly) method was tested with respect to the initialization time. The result shows that the accuracy is better than 1cm with 5-minute initialization in the distance of 10km baseline. The seaside topography was measured by the RTK GPS only, on the other hand the seafloor topography was surveyed in combination of RTK GPS and E/S. Comparing to the volume of seaside measured by RTK GPS and digital topographical map, the difference of only 2 % was achieved. This indicates that the coastal mapping with RTK GPS is successfully conducted. In addition it is also demonstrated that the 3-dimensional perspective model resulted from the undersea topography measured by RTK GPS and E/S is very close to that from the digital map. Through this study, it was verified that RTK GPS is to be very useful method in the analysis of coastal morphology owing to its capability of getting the precise DTM for the using of harbor reclamation, dredging, and the estimation of soil movement in a river.

  • PDF

Evolution of spatial light modulator for high-definition digital holography

  • Choi, Ji Hun;Pi, Jae-Eun;Hwang, Chi-Young;Yang, Jong-Heon;Kim, Yong-Hae;Kim, Gi Heon;Kim, Hee-Ok;Choi, Kyunghee;Kim, Jinwoong;Hwang, Chi-Sun
    • ETRI Journal
    • /
    • 제41권1호
    • /
    • pp.23-31
    • /
    • 2019
  • Since the late 20th century, there has been rapid development in the display industry. Only 30 years ago, we used big cathode ray tube displays with poor resolution, but now most people use televisions or smartphones with very high-quality displays. People now want images that are more realistic, beyond the two-dimensional images that exist on the flat screen, and digital holography-one of the next-generation displaysis expected to meet that need. The most important parameter that determines the performance of a digital hologram is the pixel pitch. The smaller the pixel pitch, the higher the level of hologram implementation possible. In this study, we fabricated the world-smallest $3-{\mu}m$-pixel-pitch holographic backplane based on the spatial light modulator technology. This panel could display images with a viewing angle of more than $10^{\circ}$. Furthermore, a comparative study was conducted on the fabrication processes and the corresponding holographic results from the large to the small pixel-pitch panels.

C-arm CT의 필수 성능평가 기준 마련을 위한 연구 (A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography)

  • 김은혜;박혜민;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권2호
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.

Micro-computed tomography in preventive and restorative dental research: A review

  • Ghavami-Lahiji, Mehrsima;Davalloo, Reza Tayefeh;Tajziehchi, Gelareh;Shams, Paria
    • Imaging Science in Dentistry
    • /
    • 제51권4호
    • /
    • pp.341-350
    • /
    • 2021
  • Purpose: The use of micro-computed tomography (micro-CT) scans in biomedical and dental research is growing rapidly. This study aimed to explore the scientific literature on approaches and applications of micro-CT in restorative dentistry. Materials and Methods: An electronic search of publications from January 2009 to March 2021 was conducted using ScienceDirect, PubMed, and Google Scholar. The search included only English-language articles. Therefore, only studies that addressed recent advances and the potential uses of micro-CT in restorative and preventive dentistry were selected. Results: Micro-CT is a tool that enables 3-dimensional imaging on a small scale with very high resolution. In this method, there is no need for sample preparation or slicing. Therefore, it is possible to examine the internal structure of tissue and the internal adaptation of materials to surfaces without destroying them. Due to these advantages, micro-CT has been recommended as a standard imaging tool in dental research for many applications such as tissue engineering, endodontics, restorative dentistry, and research on the mineral density of hard tissues and bone growth. However, the high costs of micro-CT, the time necessary for scanning and reconstruction, computer expertise requirements, and the enormous volume of information are drawbacks. Conclusion: The potential of micro-CT as an emerging, accurate, non-destructive approach is clear, and the valuable research findings reported in the literature provide an impetus for researchers to perform future studies focusing on employing this method in dental research.

Optimization of image reconstruction method for dual-particle time-encode imager through adaptive response correction

  • Dong Zhao;Wenbao Jia;Daqian Hei;Can Cheng;Wei Cheng;Xuwen Liang;Ji Li
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1587-1592
    • /
    • 2023
  • Time-encoded imagers (TEI) are important class of instruments to search for potential radioactive sources to prevent illicit transportation and trafficking of nuclear materials and other radioactive sources. The energy of the radiation cannot be known in advance due to the type and shielding of source is unknown in practice. However, the response function of the time-encoded imagers is related to the energy of neutrons or gamma-rays. An improved image reconstruction method based on MLEM was proposed to correct for the energy induced response difference. In this method, the count vector versus time was first smoothed. Then, the preset response function was adaptively corrected according to the measured counts. Finally, the smoothed count vector and corrected response were used in MLEM to reconstruct the source distribution. A one-dimensional dual-particle time-encode imager was developed and used to verify the improved method through imaging an Am-Be neutron source. The improvement of this method was demonstrated by the image reconstruction results. For gamma-ray and neutron images, the angular resolution improved by 17.2% and 7.0%; the contrast-to-noise ratio improved by 58.7% and 14.9%; the signal-to-noise ratio improved by 36.3% and 11.7%, respectively.

MRI Findings in Trigeminal Neuralgia without Neurovascular Compression: Implications of Petrous Ridge and Trigeminal Nerve Angles

  • Hai Zhong;Wenshuang Zhang;Shicheng Sun;Yifan Bie
    • Korean Journal of Radiology
    • /
    • 제23권8호
    • /
    • pp.821-827
    • /
    • 2022
  • Objective: To determine the anatomical characteristics of the petrous ridge and trigeminal nerve in trigeminal neuralgia (TN) without neurovascular compression (NVC). Materials and Methods: From May 2017 to March 2021, 66 patients (49 female and 17 male; mean age ± standard deviation [SD], 56.8 ± 13.3 years) with TN without NVC and 57 controls (46 female and 11 male; 52.0 ± 15.6 years) were enrolled. The angle of the petrous ridge (APR) and angle of the trigeminal nerve (ATN) were measured using magnetic resonance imaging with a high-resolution three-dimensional T2 sequence. Data on the symptomatic side were compared with those on the asymptomatic side in patients and with the mean measurements of the bilateral sides in controls. Receiver operating characteristic (ROC) analysis was conducted to evaluate the performance of APR and ATN in distinguishing TN patients from controls. Results: In TN patients without NVC, the mean ± standard deviation (SD) of APR on the symptomatic side (98.40° ± 19.75°) was significantly smaller than that of the asymptomatic side (105.59° ± 22.45°, p = 0.019) and controls (108.44° ± 15.98°, p = 0.003). The mean ATN ± SD on the symptomatic side (144.41° ± 8.92°) was significantly smaller than that of the asymptomatic side (149.67° ± 8.09°, p = 0.003) and controls (150.45° ± 8.48°, p = 0.001). The area under the ROC curve for distinguishing TN patients from controls was 0.673 (95% confidence interval [CI]: 0.579-0.758) for APR and 0.700 (CI: 0.607-0.782) for ATN. The sensitivity and specificity using the diagnostic cutoff yielding the highest Youden index were 81.8% (54/66) and 49.1% (28/57), respectively, for APR (with a cutoff score of 94.30°) and 65.2% (43/66) and 66.7% (38/57), respectively, for ATN (cutoff score, 148.25°). Conclusion: In patients with TN without NVC, APR and ATN were smaller than those in controls, which may explain the potential cause of TN and provide additional information for diagnosis.

대형 고분에서의 3차원 전기비저항 탐사 (3-D Resistivity Imaing of a Large Scale Tumulus)

  • 오현덕;이명종;김정호;신종우
    • 지구물리와물리탐사
    • /
    • 제14권4호
    • /
    • pp.316-323
    • /
    • 2011
  • 대형 고분의 발굴 조사를 위한 전기비저항 탐사법의 적용 가능성을 시험하기 위하여, 나주 복암리 3호분에 대하여 3차원 전기비저항 탐사를 수행하였다. 높은 해상도의 지하구조 영상을 얻기 위해서는 고분의 정확한 지형 구조 및 전극 위치에 대한 정보 획득이 필수적이다. 이에 따라 문화재 발굴 조사에서 사용하는 방법인 실을 이용한 구획설정법을 응용하여 전극을 설치하였다. 탐사 자료는, 전극 간격은 2 m, 측선 간격은 1 m로 하여 얻었으며, 각 탐사 측선은 상대적으로 1 m 엇갈리게 배열함으로써 전체적으로 고분에 대하여 1 m ${\times}$ 1m 크기의 격자망으로 구성하였다. 탐사 자료에 대하여 3차원 전기비저항 영상화를 수행하고 이를 기존의 발굴 조사 결과와 대비하였으며, 이로부터 확인된 매장 유구 분포와 전기비저항 영상이 매우 잘 일치함을 확인하였다. 이 연구를 통하여 대형 고분에서 매장 유구를 조사할 때 3차원 전기비저항 영상화 기술이 매우 유용함을 밝혔다.

Proteome analysis of human stomach tissue: Separation of soluble Proteins by two-dimensional Polyacrylamide gel electrophoresis and identification by mass spectrometry

  • Ha, Geun-Hyoung;Lee, Seung-Uook;Kang, Deok-Gyeong;Ha, Na-Young;Kim, Soon-Hee;Kim, Ji-Na;Bae, Jong-Min;Kim, Jae-Won;Lee, Chang-Won
    • 한국생명과학회:학술대회논문집
    • /
    • 한국생명과학회 2002년도 제38회 학술심포지움
    • /
    • pp.20-47
    • /
    • 2002
  • Two-dimensional gel electrophoresis (2-DE) maps for human stomach tissue proteins have been prepared by displaying the protein components of the tissue by 2-DE and identifying them using mass spectrometry. This will enable us to present an overview of the proteins expressed In human stomach tissues and lays the basis for subsequent comparative proteome analysis studies with gastric diseases such as gastric cancer. In this study, 2-DE maps of soluble fraction proteins were prepared on two gel images with partially overlapping pH ranges of 4-7 and 6-9. On the gels covering pH 4-7 and pH 6-9, about 900 and 600 protein spots were detected on silver staining, respectively. For protein identification, proteins spots on micropreparative gels stained by colloidal Coomassie Brilliant Blue G-250 were excised, digested in-gel with trypsln, and analyzed by peptide mass fingerprinting with delayed extraction-matrix assisted laser dosorption/ionization-mass spectrometry (DE-MALDI-MS). In all, 243 protein spots (168 spots in acidic map and 75 spots in basic map) corresponding to 136 different proteins were identified. Besides these principal maps, maps of lower resolution, i.e. overview maps (displayed on pH 3-10 gels) for total homogenate and soluble fraction, are also presented with some identifications mapped on them. Based on the 2-DE maps presented in this study, a 2-DE database for human stomach tissue proteome has been constructed and available at http://proteome.gsnu.ac.kr/DB/2DPAGE/Stomach/. The 2-DE maps and the database resulting from this study will serve important resources for subsequent proteomic studies for analyzing the normal protein variability in healthy tissues and specific protein variations in diseased tissues.

  • PDF